Other Ei Electronics Smoke Alarm manuals

Ei Electronics aico Ei146e User manual

Ei Electronics

Ei Electronics aico Ei146e User manual

Ei Electronics Ei 151TLR Ionisation User manual

Ei Electronics

Ei Electronics Ei 151TLR Ionisation User manual

Ei Electronics Ei 105C Optical Manual

Ei Electronics

Ei Electronics Ei 105C Optical Manual

Ei Electronics Ei100TY User manual

Ei Electronics

Ei Electronics Ei100TY User manual

Ei Electronics Ei 100R Ionisation User manual

Ei Electronics

Ei Electronics Ei 100R Ionisation User manual

Ei Electronics Ei 156TLR Optical User manual

Ei Electronics

Ei Electronics Ei 156TLR Optical User manual

Ei Electronics Ei160e Series User manual

Ei Electronics

Ei Electronics Ei160e Series User manual

Ei Electronics EI 100C Interconnect User manual

Ei Electronics

Ei Electronics EI 100C Interconnect User manual

Ei Electronics Ei161RC Ionisation User manual

Ei Electronics

Ei Electronics Ei161RC Ionisation User manual

Ei Electronics Ei605MTYRF User manual

Ei Electronics

Ei Electronics Ei605MTYRF User manual

Ei Electronics Ei141EK User manual

Ei Electronics

Ei Electronics Ei141EK User manual

Ei Electronics Ei 405C Manual

Ei Electronics

Ei Electronics Ei 405C Manual

Ei Electronics RadioLINK Ei 405TY Manual

Ei Electronics

Ei Electronics RadioLINK Ei 405TY Manual

Ei Electronics Ei154TL User manual

Ei Electronics

Ei Electronics Ei154TL User manual

Ei Electronics EIB140RC Series User manual

Ei Electronics

Ei Electronics EIB140RC Series User manual

Ei Electronics Ei3100RF? Ei3500RF Manual

Ei Electronics

Ei Electronics Ei3100RF? Ei3500RF Manual

Ei Electronics Ei3024 User manual

Ei Electronics

Ei Electronics Ei3024 User manual

Ei Electronics Ei603 Series User manual

Ei Electronics

Ei Electronics Ei603 Series User manual

Ei Electronics Ei603CRF User manual

Ei Electronics

Ei Electronics Ei603CRF User manual

Ei Electronics Ei100R User manual

Ei Electronics

Ei Electronics Ei100R User manual

Ei Electronics EI 170 Manual

Ei Electronics

Ei Electronics EI 170 Manual

Ei Electronics EI 100B Standard Manual

Ei Electronics

Ei Electronics EI 100B Standard Manual

Ei Electronics Ei 3105TYCH Optical User manual

Ei Electronics

Ei Electronics Ei 3105TYCH Optical User manual

Ei Electronics Ei 181 Ionisation User manual

Ei Electronics

Ei Electronics Ei 181 Ionisation User manual

Popular Smoke Alarm manuals by other brands

Dyna-Glo DGY784BDP installation instructions

Dyna-Glo

Dyna-Glo DGY784BDP installation instructions

NOXE LUMENS Installation and user guide

NOXE

NOXE LUMENS Installation and user guide

Develco SMAZB-141 installation manual

Develco

Develco SMAZB-141 installation manual

Kidde PI2010CA user guide

Kidde

Kidde PI2010CA user guide

Honeywell 5800COMBO Installation and setup guide

Honeywell

Honeywell 5800COMBO Installation and setup guide

Gentex 7109CS installation instructions

Gentex

Gentex 7109CS installation instructions

FireAngel Thermoptek ST-622 user manual

FireAngel

FireAngel Thermoptek ST-622 user manual

teko Astra-42A user guide

teko

teko Astra-42A user guide

ELRO FS8110 instruction manual

ELRO

ELRO FS8110 instruction manual

Heiman SMOKI NS-626PHS user manual

Heiman

Heiman SMOKI NS-626PHS user manual

Siemens PE-11C installation instructions

Siemens

Siemens PE-11C installation instructions

Resolution Products RE612 CryptiX quick start guide

Resolution Products

Resolution Products RE612 CryptiX quick start guide

First Alert PC900V user manual

First Alert

First Alert PC900V user manual

Eminent EM6590 E-Domotica user manual

Eminent

Eminent EM6590 E-Domotica user manual

Carrier Kidde Quell Q301 user manual

Carrier

Carrier Kidde Quell Q301 user manual

Family Gard FG225 user manual

Family Gard

Family Gard FG225 user manual

Regin SDD-S65 instruction manual

Regin

Regin SDD-S65 instruction manual

LST ÜMS-55000-841 Specification sheet

LST

LST ÜMS-55000-841 Specification sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Model Ei166R Optical
•Remote control capability
•Easi-Fit base
•Tamper proof rechargeable lithium battery back up
•High performance optical chamber with integral
insect screen
•Test/Hush button
•Advanced suppression and calibration technology
•Interconnectable to other Ei mains powered alarms
•Built in auto self test feature
•Low power cell warning
•Kitemarked to BS5446-1:2000
•5 year guarantee
Product Description
The Ei166R is an Optical Smoke Alarm that runs on
230V AC mains power, and has built in tamper proof
rechargeable lithium cells that act as a battery back up in
the event of mains failure. These rechargeable lithium
cells are designed to have a ten year life and outlast the
life of the smoke alarm itself, whilst providing up to six
months of smoke alarm operation without mains power.
The Ei166R is supplied with the Easi-Fit base that allows
very quick and simple installation of the smoke alarm,
combined with simple detector head removal and
replacement. The Easi-Fit base automatically connects
both mains power and battery as the detector head
slides on to the Easi-Fit base.
The Ei166R allows the detector to be controlled remotely
by either a “Test/Hush” Switch (Ei152), a “Locate” Switch
(Ei159) or a Manual Call Point (MCP400). If the Ei166R
is also interconnected to other Ei mains powered alarms
then the whole system can be controlled remotely.
The Ei166R has other advanced features such as
integral insect screens to reduce the chances of false
alarms, as well as the ability to interconnect up to twelve
alarms.
The Ei166R has built in circuitry to aid suppression of
voltage transients and RF interference to further reduce
the chances of false alarms under such conditions.
Operation
•The green indicator will illuminate to show mains
power is present
•The red indicator will flash every 40 seconds to
show that the detector has performed an automatic
self test
•The red indicator will flash rapidly to show an alarm
condition for the smoke detector
•The “Test/Hush” button will either silence false
alarms or perform a unit self test
•In “Test” mode the alarm will perform a self test and
sound the horn
•In “Hush” mode the alarm enters a ten minute period
of reduced sensitivity to overcome false alarm
conditions, and will then automatically reset itself
•When interconnected to other Ei mains powered
alarms, an alarm on one detector will trigger all other
interconnected alarms within one second (only the
triggered alarm will flash a red indicator)
•The smoke detector will emit a beep and flash the
red light every 40 seconds to indicate that the
battery back up is depleted and needs recharging
•
MAINS POWERED 230V~
Rechargeable Battery Back-Up
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053
Email. [email protected]
www.eielectronics.com
Model Ei166R Optical
Installation & Placement
Wiring for Interconnected Alarms
Be very careful about correctly wiring the alarms as mixing Live and Neutral
will blow/damage interconnected alarms.
Alarms should be placed in accordance with the general guidelines shown in
the diagram above. These recommendations are based on the problem of
areas of “dead air” close to corners of rooms and apexes of ceilings, which
could result in the prevention of smoke reaching the smoke detector
Please consult instruction booklet for specific installation details
Important Precaution:
Do not install the actual smoke/heat alarm
itself in new or renovated buildings until all
work is completed (including floor
coverings) and the building has been fully
cleaned. The wiring can be installed when
appropriate. (Excessive dust and debris
from building work can contaminate the
smoke chamber and cause problems, and
it will also invalidate the guarantee). If it
must be installed, cover it completely,
particularly around the edges, with a dust
cover (eg. a plastic bag), until all cleaning
is finished.. Connect wires to the unit as in
wiring diagram. All wiring must comply
with local codes.
Technical Specification
Sensor Optical, uses light scatter from
smoke
Sensitivity: Complies with BS 5446 Part 1:
2000
Source: Contains no radioactive material
Airspeed: Essentially immune to the effect
of airspeed.
Button Test: Simulates the effect of smoke and
checks chamber, electronics and
horn.
Ambient Light: Chamber housing design and
compensation overcomes
problems with stray light.
Automatic Self-Test: Smoke Chamber is tested every 40
Sec. and unit beeps (without LED
flash) if it is degraded.
Insect Screen: Prevents insects or debris entering
chamber (1.00mm mesh size)
Supply Voltage: 240V AC
Battery back up: Rechargeable lithium cells
Specifications are subject to change
Power-On Indicator: Continuous green LED
Alarm: Electronic Piezoelectric horn
Alarm Sound Output: 85dB (minimum) at 3m
Alarm Status: Red LED flashes every second on
unit sensing fire
Temperature Range: 0 to 40°C
Humidity Range: 15% to 95% Relative Humidity
Remote Control: Ei152, Ei159 or MCP400
Interconnect: Up to 12 interconnected
EI140/141/143/144/145/146/161/1
64/166 smoke or heat alarms,
along with an EI128 relay base
Fixing: Easi-Fit mounting base
Plastic material: UL94VO flame retardant
Dimensions: 152mm diameter x 50mm depth
Weight: 385g
Warranty: 5 year (limited) warranty
Approvals: Kitemarked to BS5446-1:2000, CE
Approved
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053
Email. [email protected]