Ei Electronics Ei166R User manual

Model Ei166R Optical
•Remote control capability
•Easi-Fit base
•Tamper proof rechargeable lithium battery back up
•High performance optical chamber with integral
insect screen
•Test/Hush button
•Advanced suppression and calibration technology
•Interconnectable to other Ei mains powered alarms
•Built in auto self test feature
•Low power cell warning
•Kitemarked to BS5446-1:2000
•5 year guarantee
Product Description
The Ei166R is an Optical Smoke Alarm that runs on
230V AC mains power, and has built in tamper proof
rechargeable lithium cells that act as a battery back up in
the event of mains failure. These rechargeable lithium
cells are designed to have a ten year life and outlast the
life of the smoke alarm itself, whilst providing up to six
months of smoke alarm operation without mains power.
The Ei166R is supplied with the Easi-Fit base that allows
very quick and simple installation of the smoke alarm,
combined with simple detector head removal and
replacement. The Easi-Fit base automatically connects
both mains power and battery as the detector head
slides on to the Easi-Fit base.
The Ei166R allows the detector to be controlled remotely
by either a “Test/Hush” Switch (Ei152), a “Locate” Switch
(Ei159) or a Manual Call Point (MCP400). If the Ei166R
is also interconnected to other Ei mains powered alarms
then the whole system can be controlled remotely.
The Ei166R has other advanced features such as
integral insect screens to reduce the chances of false
alarms, as well as the ability to interconnect up to twelve
alarms.
The Ei166R has built in circuitry to aid suppression of
voltage transients and RF interference to further reduce
the chances of false alarms under such conditions.
Operation
•The green indicator will illuminate to show mains
power is present
•The red indicator will flash every 40 seconds to
show that the detector has performed an automatic
self test
•The red indicator will flash rapidly to show an alarm
condition for the smoke detector
•The “Test/Hush” button will either silence false
alarms or perform a unit self test
•In “Test” mode the alarm will perform a self test and
sound the horn
•In “Hush” mode the alarm enters a ten minute period
of reduced sensitivity to overcome false alarm
conditions, and will then automatically reset itself
•When interconnected to other Ei mains powered
alarms, an alarm on one detector will trigger all other
interconnected alarms within one second (only the
triggered alarm will flash a red indicator)
•The smoke detector will emit a beep and flash the
red light every 40 seconds to indicate that the
battery back up is depleted and needs recharging
•
MAINS POWERED 230V~
Rechargeable Battery Back-Up
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053
Email. [email protected]
www.eielectronics.com
Model Ei166R Optical
Installation & Placement
Wiring for Interconnected Alarms
Be very careful about correctly wiring the alarms as mixing Live and Neutral
will blow/damage interconnected alarms.
Alarms should be placed in accordance with the general guidelines shown in
the diagram above. These recommendations are based on the problem of
areas of “dead air” close to corners of rooms and apexes of ceilings, which
could result in the prevention of smoke reaching the smoke detector
Please consult instruction booklet for specific installation details
Important Precaution:
Do not install the actual smoke/heat alarm
itself in new or renovated buildings until all
work is completed (including floor
coverings) and the building has been fully
cleaned. The wiring can be installed when
appropriate. (Excessive dust and debris
from building work can contaminate the
smoke chamber and cause problems, and
it will also invalidate the guarantee). If it
must be installed, cover it completely,
particularly around the edges, with a dust
cover (eg. a plastic bag), until all cleaning
is finished.. Connect wires to the unit as in
wiring diagram. All wiring must comply
with local codes.
Technical Specification
Sensor Optical, uses light scatter from
smoke
Sensitivity: Complies with BS 5446 Part 1:
2000
Source: Contains no radioactive material
Airspeed: Essentially immune to the effect
of airspeed.
Button Test: Simulates the effect of smoke and
checks chamber, electronics and
horn.
Ambient Light: Chamber housing design and
compensation overcomes
problems with stray light.
Automatic Self-Test: Smoke Chamber is tested every 40
Sec. and unit beeps (without LED
flash) if it is degraded.
Insect Screen: Prevents insects or debris entering
chamber (1.00mm mesh size)
Supply Voltage: 240V AC
Battery back up: Rechargeable lithium cells
Specifications are subject to change
Power-On Indicator: Continuous green LED
Alarm: Electronic Piezoelectric horn
Alarm Sound Output: 85dB (minimum) at 3m
Alarm Status: Red LED flashes every second on
unit sensing fire
Temperature Range: 0 to 40°C
Humidity Range: 15% to 95% Relative Humidity
Remote Control: Ei152, Ei159 or MCP400
Interconnect: Up to 12 interconnected
EI140/141/143/144/145/146/161/1
64/166 smoke or heat alarms,
along with an EI128 relay base
Fixing: Easi-Fit mounting base
Plastic material: UL94VO flame retardant
Dimensions: 152mm diameter x 50mm depth
Weight: 385g
Warranty: 5 year (limited) warranty
Approvals: Kitemarked to BS5446-1:2000, CE
Approved
Shannon Free Zone, Shannon, Co. Clare, Ireland.
Ph.+353 61 471277 Fx.+353 61 471053
Email. [email protected]
www.eielectronics.com

Other Ei Electronics Smoke Alarm manuals

Ei Electronics Ei2110 User manual

Ei Electronics

Ei Electronics Ei2110 User manual

Ei Electronics Ei146 Optical User manual

Ei Electronics

Ei Electronics Ei146 Optical User manual

Ei Electronics EiA600 Series User manual

Ei Electronics

Ei Electronics EiA600 Series User manual

Ei Electronics Ei 169 Manual

Ei Electronics

Ei Electronics Ei 169 Manual

Ei Electronics EI 100L Emergency Light User manual

Ei Electronics

Ei Electronics EI 100L Emergency Light User manual

Ei Electronics RadioLINK Ei170RF User manual

Ei Electronics

Ei Electronics RadioLINK Ei170RF User manual

Ei Electronics Easichange Series User manual

Ei Electronics

Ei Electronics Easichange Series User manual

Ei Electronics Ei605 Series User manual

Ei Electronics

Ei Electronics Ei605 Series User manual

Ei Electronics Ei 181 Ionisation User manual

Ei Electronics

Ei Electronics Ei 181 Ionisation User manual

Ei Electronics EI129 User manual

Ei Electronics

Ei Electronics EI129 User manual

Ei Electronics Ei154TL User manual

Ei Electronics

Ei Electronics Ei154TL User manual

Ei Electronics Ei 176 Optical User manual

Ei Electronics

Ei Electronics Ei 176 Optical User manual

Ei Electronics BROOKS EIB160e Series User manual

Ei Electronics

Ei Electronics BROOKS EIB160e Series User manual

Ei Electronics Ei 100TYC Ionisation User manual

Ei Electronics

Ei Electronics Ei 100TYC Ionisation User manual

Ei Electronics Ei141 Ionisation User manual

Ei Electronics

Ei Electronics Ei141 Ionisation User manual

Ei Electronics EI 100S Silencer User manual

Ei Electronics

Ei Electronics EI 100S Silencer User manual

Ei Electronics Ei100TY User manual

Ei Electronics

Ei Electronics Ei100TY User manual

Ei Electronics Ei 151TLR Ionisation User manual

Ei Electronics

Ei Electronics Ei 151TLR Ionisation User manual

Ei Electronics Ei160 Manual

Ei Electronics

Ei Electronics Ei160 Manual

Ei Electronics Ei Ei168RC User manual

Ei Electronics

Ei Electronics Ei Ei168RC User manual

Ei Electronics Ei 405C Manual

Ei Electronics

Ei Electronics Ei 405C Manual

Ei Electronics Ei128R User manual

Ei Electronics

Ei Electronics Ei128R User manual

Ei Electronics Ei161RC Ionisation User manual

Ei Electronics

Ei Electronics Ei161RC Ionisation User manual

Ei Electronics EiA207 Series User manual

Ei Electronics

Ei Electronics EiA207 Series User manual

Popular Smoke Alarm manuals by other brands

ELRO K170501528 user manual

ELRO

ELRO K170501528 user manual

System Sensor 1151 Installation and maintenance instructions

System Sensor

System Sensor 1151 Installation and maintenance instructions

olympia electronics BSR-6055/A/MAR quick start guide

olympia electronics

olympia electronics BSR-6055/A/MAR quick start guide

First Alert SA710 user manual

First Alert

First Alert SA710 user manual

GEZE GC 172 Supplementary sheet

GEZE

GEZE GC 172 Supplementary sheet

gsc evolution 104300001 instruction manual

gsc evolution

gsc evolution 104300001 instruction manual

Red Smoke Alarms R9 installation instructions

Red Smoke Alarms

Red Smoke Alarms R9 installation instructions

Gentec-E PH100-Si user manual

Gentec-E

Gentec-E PH100-Si user manual

System Sensor B402B Installation and maintenance instructions

System Sensor

System Sensor B402B Installation and maintenance instructions

Var-Tec FDR-16 AR Series Installation Wiring Diagram

Var-Tec

Var-Tec FDR-16 AR Series Installation Wiring Diagram

Gira 0869 00/04 Instructions for installation

Gira

Gira 0869 00/04 Instructions for installation

Kidde 914 user guide

Kidde

Kidde 914 user guide

Bosch D7050 installation instructions

Bosch

Bosch D7050 installation instructions

jablotron JA-60SR quick start guide

jablotron

jablotron JA-60SR quick start guide

INIM Electronics V200 quick start guide

INIM Electronics

INIM Electronics V200 quick start guide

Xtralis ICAM IFT Commissioning Guide

Xtralis

Xtralis ICAM IFT Commissioning Guide

BRK electronic 83RN quick start guide

BRK electronic

BRK electronic 83RN quick start guide

DSC WS4916 Series User manual and installation instructions

DSC

DSC WS4916 Series User manual and installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.