manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. EIGER
  6. •
  7. Laboratory Equipment
  8. •
  9. EIGER EG-UV03 User manual

EIGER EG-UV03 User manual

EG-UV03
Please read these instructions carefully and retain for future reference.
INSTRUCTION MANUAL
ULTRAVIOLET DISINFECTION SERIES
ULTRAVIOLET DISINFECTION LAMP
• Material: ABS & Metal
• Remote Distance: 15 M (Wireless)
• Base Type: 2G11
• Lamp Life: > 8000 Hours
• Peak Ultraviolet Wavelength of Ultraviolet Radiation: 253.7 nm
• Radiation Intensity: 36 W ≥ 118 μw / cm²
• Product Dimensions: 120 x 120 x 475 mm
• Product Weight: 625 g
• Packaging Dimensions: 160 x 150 x 490 mm
• Tube Material: Quartz Glass
• Voltage: 220 V
• Power: 36 W
• Sterilization Rate: 99.9%*
• Colour of the Shell Casing: Black
*Refer to Table 1 for guidelines on use.
1 x 36 W Ultraviolet Sterilization Lamp
1 x Remote Control
1 x Instruction Manual
• 36 W High Quality Quartz Lamp
• 8000 Hour Lamp Life Span
• 15 / 30 / 60 Minute Timer Function
• Remote Control
TABLE 1. GUIDELINES FOR STERILIZATION TIMES
Room Size (m2)Sterilization Time
(Min.)
10 15
15 30
20 30
25 60
30 60
35 60
40 60
PRINCIPLE OF ULTRAVIOLET C (UV-C) STERILIZATION
The principle of UVC sterilization and disinfection is that ultraviolet light with a wavelength
of 200 ~ 280 nm can destroy the molecular structure of DNA (deoxyribonucleic acid) or
RNA (ribonucleic acid) of microbial cells, thereby changing the biological activity of DNA,
resulting in DNA inactivation, resulting in death of growing cells and (or) regenerative cell
death, to achieve the effect of sterilization and disinfection.
1. Ensure that the power is switched off. Place the
lamp tube in the pre-installation position, pull
the clip towards the lamp tube and clip into place.
2. Then insert the lamp tube by pressing it down
into the lamp base until it is secure.
3. To remove the lamp tube, reverse this process.
23
INSTALLING AND REMOVING THE LAMP TUBE
6
WARRANTY
This Eiger Ultraviolet Disinfection Lamp comes with a standard 12-month limited
warranty against manufacturing defects and faults. Should your product be
unboxed with any faulty parts, poor finishing or visible damage, or fail to perform
due to a manufacturing defect or poor workmanship, please return it with your
proof of purchase (till slip or invoice) to the store of purchase for an exchange, or
repair, depending on the store’s returns policy.
This warranty commences from the date of purchase.
Kindly retain your proof of purchase as well as the packaging for your
warranty period.
NOTE:
The Warranty does not apply to a product that:
a. Has failed due to excessive wear and tear beyond what is considered to
be reasonable.
b. Has been misused or neglected.
c. Has been damaged accidentally or by Force Majeure including fire and flooding.
d. Has been used or operated contrary to operating or maintenance instructions
outlined in this manual.
The Store of Purchase / Seller cannot accept any returned products that have not
been returned in accordance with this warranty or which do not follow their own
Returns Policy. Please refer to the Store of Purchase / Sellers Returns Policy
for details.
Should you require any further assistance or have any questions on your warranty,
please contact the store of purchase.
4
1. Plug the power cord into the appropriate wall socket or adaptor to activate
standby mode.
2. Use the remote controller to set the timer to 15 / 30 / 60 minutes. Use table 1 as
a guide to select the optimal timer setting for the room to be disinfected. Default
mode on the remote control is 15 minutes.
3. Indicator lights:
a. Red light (default) = 15 minutes
b. Green light = 30 minutes
c. White light = 60 minutes
4. Sound Prompt: Once the timer has been activated, the lamp will emit a ringing
sound for 30 seconds, giving the user time to exit the room before switching on.
DO NOT remain in the room while the sterilization lamp is in operation.
Ensure that all children, adults and animals are out of the room for the duration
of sterilization.
5. Once the timer has run down, the UV lamp and indicator lights will switch off and
the device returns to standby mode.
INSTRUCTIONS FOR USE
1. Ultraviolet rays are harmful and can cause damage to the eyes and skin of humans
and animals. The room being sterilized should be clear of all humans and animals
while the device is in operation. Open windows and ventilate room for more than
10 - 20 minutes after sterilization.
2. The surface of the ultraviolet lamp tube should be kept clean during the use of this
product. Check to see if there is dust or oil on the surface of the lamp, and wipe it
clean with a damp cloth before use to avoid compromising the sterilization effect.
3. When using ultraviolet disinfection lamps to sterilize, it is best to close doors
and windows, close curtains, open quilts, books, etc. to achieve the best
sterilization effect.
4. If clothes, towels and other items are sterilized at close range, the sterilization time
should not exceed 15 minutes (see table 1).
5. Cover any delicate artworks or paintings with cloth or paper before using the UV
sterilizer to avoid damage.
6. If you are accidentally burned by a disinfection lamp it is recommended that you seek
medical attention.
SAFETY PRECAUTIONS
5
ENVIRONMENTALLY FRIENDLY DISPOSAL
IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN
ACCORDANCE WITH THE EUROPEAN DIRECTIVE ON WASTE ELECTRICAL AND
ELECTRONIC EQUIPMENT.
At the end of its working life, the product must not be disposed of as urban
waste. It must be taken to a special local authority differentiated waste
collection center or a dealer providing this service. Disposing of a household
appliance separately avoids possible negative consequences for the
environment and health deriving from inappropriate disposal and enables
the constituent materials to be recovered to obtain significant savings in
energy and resources. As a reminder of the need to dispose of household
appliances separately, the product is marked with a crossed-out
wheeled dustbin.
• Never dispose of used electronics with ordinary solid wastes, since they contain toxic
substances.
• Always dispose of used electronics in accordance with the prevailing community
regulations that apply to the disposal of electronics. If there are no local regulations
concerning electronics disposal, please dispose of the device in a waste bin for
electronic devices
DISCLAIMER
All product and company names are trademarks™ or registered®trademarks
of their respective holders. Use of them does not imply any affiliation with or
endorsement by them.

Popular Laboratory Equipment manuals by other brands

SH Scientific SH-AC-60M manual

SH Scientific

SH Scientific SH-AC-60M manual

velda UV-C UNIT User instructions

velda

velda UV-C UNIT User instructions

IKA ULTRA-TURRAX T50 basic operating instructions

IKA

IKA ULTRA-TURRAX T50 basic operating instructions

Omega Mag-Bind FFPE RNA 96 product manual

Omega

Omega Mag-Bind FFPE RNA 96 product manual

SKC Quick Take 30 operating instructions

SKC

SKC Quick Take 30 operating instructions

Blue-Ray Biotech BluePette user manual

Blue-Ray Biotech

Blue-Ray Biotech BluePette user manual

Scilogex SCI20-S user manual

Scilogex

Scilogex SCI20-S user manual

Labomed SL 20i user manual

Labomed

Labomed SL 20i user manual

Hanna Instruments Groline HI981412 instruction manual

Hanna Instruments

Hanna Instruments Groline HI981412 instruction manual

Witeg Wisd WOV Series operating manual

Witeg

Witeg Wisd WOV Series operating manual

RND RND 560-00156 user manual

RND

RND RND 560-00156 user manual

Flinn Scientific AP8503 owner's manual

Flinn Scientific

Flinn Scientific AP8503 owner's manual

Philips AVENT SVF271/42 Instruction leaflet

Philips

Philips AVENT SVF271/42 Instruction leaflet

NuAire NuWind NU-C200V Service manual

NuAire

NuAire NuWind NU-C200V Service manual

Verfilco Transferpette-12 operating manual

Verfilco

Verfilco Transferpette-12 operating manual

KD Scientific KDS LEGATO 100 user manual

KD Scientific

KD Scientific KDS LEGATO 100 user manual

Newport 500B Series user manual

Newport

Newport 500B Series user manual

Bibby Sterilin Stuart SB2 Instructions for use

Bibby Sterilin

Bibby Sterilin Stuart SB2 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.