Features
- GSM transmiter
- Supports up to 10 remote controls, 99 wireless accessories and 50 RFID tags
- Can store up to 5 phone numbers, 5 SMS numbers.
a Central Monitoring System)
- Arm / disarm the system by SMS, phone call, or App (on iOS or Android)
- Can be disarmed by RFID tag
- Built-in siren (110dB)
- Call function from the panel
- SMS alerts for power failure, power recovery and low battery
- Audio surveillance of the site from distance
- 2 x 800mAh lithium batteries included (8h battery life in standby mode)
Speci ications
Product name
ST-SK1
SKU
ST-SK1
Control panel power supply
Input: AC 110-240V / 50-60 Hz
Output: DC 12V / 800 A
GSM working frequency
850 / 900 / 1800 / 1900 mHz
Radio-frequency
433.92MHz (±75KHz)
Transmission distance
80m in open space
Standby current
80ma
Alarm current
300mA
Backup batteries
Lithium Baeries: 3.7V / 800 mAh x 2 (BL-5B)
(8h baery life in standby mode)
Internal siren
95dB
Housing material
ABS plasc
Operating conditions
Temperature: -10°C~55°C
Humidity: ≤ 80% (non-condensing)
Control panel dimensions (L x W x H)
188 x 125 x 25 mm
Boxcontent
SS1 Control Panel x1
Moton Detectors x1
Door / Window Contacts x1
Remote Controls x2
RFID Tags x2
AC Adaptor x1
Documentaon x1
Boxcontent
Call
Clear
RFID Reader
Home Mode
LCD Display
Disarm
Record
Arm
SOS
ControlPanelLayout(Back)
Power On/O
Adapter interface
24h Zone
Electronic lock
Wired siren
GND
SPK
LOCK
Z1
+12V
GND
Monitoring MIC
Speaker
Power Supply Interface
Tamper Switch
Power Switch
Telephone Interface
Battery
Compartment
SIM Card Slot

54
QuickStart-upGuide
ConnectyourSystem
UsingtheGSMtransmier(SIMcard)
Open the baery compartment at the back of the control panel and insert a SIM card in the
control panel.
Important
Before using the SS1 in GSM mode, you need to purchase a SIM card that works on the GSM
network with 850 / 900 / 1800 / 1900 MHz frequency. We recommend you to subscribe to a
plan with unlimited texts and one hour of voice. For more informaon, please contact your local
reseller.
Important
Make sure the SIM card does not require any PIN code. For more informaon, please contact
your local reseller.
TurningyourSystemon
1.
Plug the AC adaptor to an AC socket.
2.
Plug the output connector of the AC adaptor into the
adaptor interface in the baery compartment at the back
of the control panel.
3. Turn the power switch to "ON" (in the
battery compartment at the back of the control panel).
MounttheControlPanel
Fix the wall-mounng bracket on the wall with screws. Wedge the panel on the bracket, make sure
they t well.
BasicOperations
ArmtheSystem
Press the Arm button " " on the control panel. The control panel beeps once: the system is
armed. The LCD display indicates "Armed" and the Arm icon on the control panel is lit.
Note
If the Entry / Exit Delay is acvated, all zones except the 24h zone will be armed aer the delay set
(refer to the instrucons on page 10 of this manual “Entry / Exit Delay”).
DisarmtheSystem
Type your user code and press the Disarm button " " on the control panel. The control
panel beeps twice: the system is disarmed.
HomeMode
Press the Home buon " " on the control panel. The control panel beeps once: the system is armed
in Home Mode.
All the sensors assigned to the Normal zone are armed. The sensors assigned to the Home zone
are disarmed.
EmergencyMode
Hold the “#SOS” button for 3 seconds. The alarm is triggered immediately and the siren rings out.
At the same time, the control panel dials the stored phone numbers.

6
SpeedDial
Press the Call button “ ” on the control panel for 3 seconds: the panel auto-dials the first
stored phone number. Press the Call button “ ” to end the call.
Hands-freePhoneCallfromthePanel
ThroughGSM
Press the Call button“ ” on the control panel,type the phone number you wish to call and press
the Call button “ ”again.
Record/PlayaVoiceMemo
Long press the Record Voice Memo buon to record a 10-second voice message. The Play Voice Memo Buon
blinks when a message has been recorded. Push the center of the RFID reader in the control panel to listen to the
voice memo. The LED indicator turns o when the voice memo is being played. Touch it again to replay the memo.
HardReset
Turn the control panel on. Press the tamper switch at the back of the control panel 5 mes
wirthin 5 seconds aer having turned it on.
Sengs will be restored to default values. Stored phone numbers and connected accessories
will be cleared.
7
Setupfromthecontrolpanel
The SS1 must be set up before using for the rst me. During the setup of the system, the control
panel can be powered either by the AC power adapter or by the backup baeries.
Defaultcodes
- Admin code (necessary to set up your system): 123456
- User code (necessary to disarm your system or stop the alarm): 1234
- Duress code: 0000 (enables you to trigger a duress alarm)
- Open door code: 8888 (enables you to open an electronic door lock plugged to your
control panel and disarm your system or stop the alarm)
The control panel of your alarm system features an LCD display that enables you to navigate
through the menu of the control panel and set up your alarm system.
To enter the setng menu, In disarm status, then ( + Enter)on the control panel.
In the table on the next page, each column represents a menu or a sub menu. Each menu or
submenu will be displayed on one of the two lines of the LCD display. On the LCD display, the
current menu, submenu, or seng is shown on the line at the boom, while the previous menu
or submenu is shown on the line at the top.
Navigate and select the setting you wish to modify with the keys “ ”or “ ”, and enter
each menu or sub menu by pressing “Enter”.
How to use the keyboard
“*“ = delete
“ ” = move forward
“ ” = move backward
“Enter” = select / confirm
“Esc” = back / previous step in the menu / cancel
The tables on the next pages summarize all the sengs that can be accessed and modied on
the control panel.

98
Main Menu Sub Menu 1 Sub Menu 2 Sub Menu 3 Comments
Phone numbers
Phone[1~5] is:
-
Select the phone or SMS number you want to edit, type in the phone number and confirm with the key "Enter".
Use the key *" " to clear.
5 phone numbers and 5 SMS numbers can be stored in the control panel.
SMSNum[1~5]Is:
Accessories Remote&Keypad
Add a new 01/10 30
The LCD screen displays “01/10” (at the left), which indicates the number of the remote control you are about to
connect (01 is the current remote control, 10 is the total number of remote controls you can connect), and
"30" (at the right), which indicates the time remaining to connect the remote control. Press any key on the
keypad or remote control, you hear one beep: the connection is successful.
Once the remote control has been added, the countdown starts over from 30 so that you can register another
remote control in control panel (up to 10 remote control can be registered in the control panel). Press Esc to exit.
Delete All 1=YES 0=NO
Delete a Remote Input 01-10: Enter the number of the Remote Control you wish to delete and press "Enter".
Accessories RFIDTag
Add a new 01/50 30
The LCD screen displays “01/50” (at the left), which indicates the number of the RFID tag you are about to
connect (01 is the current RFID tag, 50 is the total number of tags you can connect), and "30" (at the right), which
indicates the time remaining to connect the RFID tag. Swipe the RFID tag in front of the RFID reader, you hear
one beep: the connection is successful.
Once the RFID tag has been added, the countdown starts over from 30 so that you can register another RFID tag in
control panel (up to 50 tags can be registered in the control panel). Press Esc to exit.
Delete all 1=YES 0=NO
Delete a Tag Input 01-50: Enter the number of the RFID tag you wish to delete and press "Enter".
Accessories Wireless
Sensors
Add a new
Home Zone
Delay Zone
Normal Zine
24-H Zone
Select the sensor type you wish your sensor to be assigned to (Normal Sensor, 24 Hour Sensor, Delay Sensor,
or Home Sensor), press “Enter” to confirm. For more information on zone setup, please refer to page 14 of
this manual.
The LCD screen displays “01/99” (at the left), which indicates the number of the sensor you are about to connect
(01 is the current sensor, 99 is the total number of sensors you can connect), and "30" (at the right), which
indicates the time remaining to connect the sensor. Trigger the sensor, you hear one beep: the connection is
successful.
Once the sensor has been added, the countdown starts over from 30 so that you can register another sensor in
control panel (up to 99 sensors can be registered in the control panel). In such case, the sensor will be added to
the same zone. Press Esc to exit.
Delete all? 1=YES 0=NO
Delete a Sensor Input 01-99: Enter the number of the sensor you wish to delete and press "Enter".
Accessories TestMode -
Trigger the sensors you have previously connected to the control panel. You hear 1 beep, the LCD screen displays
the signals that have been respectively sent by each sensor triggered. Make sure all the sensors you have
triggered are mentioned on the LCD screen. Press “Esc” to exit the test mode.
This mode enables you to test if the sensors have been connected successfully to the control panel.

1110
Main Menu Sub Menu 1 Sub Menu 2 Sub Menu 3 Comments Note
System Seng DateandTime YYYY-MM-DD TIME
System Seng DateFormat
System Seng EntryExitDelay
Entry Delay 000-300 This funcon can be used if you do not want to bring a remote con-
trol or RFID tag with you. When the system is armed, you hear one
beep every second to remind you to leave. The beep rhythm speeds
up during the last 10 seconds. If an intruder is detected, the alarm
will be delayed accordingly.
Time is calculated in seconds. The Entry and Exit Delay can be set
from 0 to 300 seconds.
The entry and exit delays only work
for sensors connected as Delay Zone
accessories (see "Wireless" on page 8).
The EntryDelay gives you me to disarm
the system on the control panel without
triggering an alarm.
The ExitDelay gives you me to arm the
system on the control panel and leave your
home without triggering an alarm.
Exit Delay 000-300
System Seng AutoArm/Disarm
Auto Arm Time <00:00>
You can set up the system to arm and disarm automacally at a
dened me every day.
Seng Auto Arm and Auto Disarm to
the exact same me will deacvate the
funcon.
Auto Disarm Time <00:00>
ON or OFF?
System Seng ControlbyPhone ON or OFF? -
You can acvate or deacvate the control of your system by phone
call. Acvang the control by phone call enables you to arm and
disarm the system and monitor your home by phone call.
See instrucons on page 14 for more
informaon on the control of the system
by phone call.
System Seng GSMFailAlarm ON or OFF? Nocaon of SIM/ GSM signal problem. Deacvate this funcon if you want to
use the alarm system in PSTN mode only.
System Seng Keypadtones ON or OFF? - Acvate or deacvate the sound when typing on the keyboard of the
control panel.
System Seng Accesscode
Admin Code 123456 Your admin code enables you to enter the setup menu.
It is recommended to change all codes
before using your system for the rst
me and to keep your codes secret
User Code 1234
Your user code enables you to disarm the system on the control
panel. The user code is the access code requested when you call the
control panel.
Duress Code 1111
In case of emergency, when you are requested to disarm the system
by force, it is recommended to disarm your system with your Duress
Code. The panel will silently dial the stored phone numbers.
Open Door Code 8888 You can open electronic doors using this code. The door must be
wired to the [LOCK] interface on the back of the control panel.

1312
Main Menu Sub Menu 1 Sub Menu 2 Sub Menu 3 Comments Note
System Sengs RingTimes <1-9>: 5 -
Enter the value (from 1 to 9) and confirm with "Enter".
This funcon enables you to determine the number of mes the control
panel will ring before taking your call (for control by phone call).
System Sengs SirenAlertTime <1-9Min>: 3
Enter the value (from 1 to 9) and confirm with "Enter".
This funcon enables you to determine for how long the siren rings out
in case of alarm.
System Sengs BacklightTime <0-120s>: 30 - Enter the value (from 0 to 120) and confirm with "Enter".
Default seng is 30 seconds.
System Sengs SirenSetup
Wired Siren
Siren Switch
ON/OFF
Enable / Disable the siren.
Default seng: On Wired siren refers to a siren connected
to the control panel by wire.
Arm/Disarm Tone
ON/OFF
Arm / Disarm silently.
Default seng: On
Built-in Siren
Siren Switch
ON/OFF
Enable / Disable the siren.
Default seng: On Built-in siren refers to the siren featured
in the control panel.
Arm/Disarm Tone
ON/OFF
Arm / Disarm silently.
Default seng: On
Wireless Siren
Siren Switch
ON/OFF
Enable / Disable the siren.
Default seng: On Wireless siren refers to a siren connect-
ed to the control panel by radio-fre-
quency.
Arm/Disarm Tone
ON/OFF
Arm / Disarm silently.
Default seng: On
System Sengs
UserID On / O -When Disarm Upload is on, the system will upload the history of
arm/disarm events to the to the CMS.
DisarmUpload On / O -
System Sengs CallRecycle <1-9>: 3
When the alarm is triggered, the control panel dials the numbers
you have stored. If you do not disarm the system, the control panel
will call you again (up to 9 mes). The “Call Recycle” funcon en-
ables you to dene the number of mes the control panel aempts
to call you. Default seng: 3 mes.
System Sengs Language - - Select the language you wish to choose and confirm with "Enter". Languages available may vary depending
on the version of your product.
System Sengs Reset 1=YES 0=NO -All system sengs will be restored to default seng.
Stored phone numbers and connected accessories will be cleared.
System Sengs About About Jun 4 2014 -
History -- - Choose the event log you need to track, press “Enter”. The control panel keeps in record the
latest 150 event logs.

1514
Zonesetupofaccessories
Every detector can be assigned to 4 dierent categories of zones: Home Zone, Delay Zone, Normal
Zone and 24-H Zone. To assign a detector to a zone, follow the instrucons on page 8 of this
manual (the zone will be assigned at the me of connecon of the accessory).
Normalzone
When the system is armed, if a sensor is triggered, the siren rings out. When the system is disarmed,
sensors do not trigger an alarm.
24hzone
Regardless the system is armed or disarmed, sensors assigned to the 24h zone can trigger an alarm.
Delayzone
If you want to set up the entry and exit delay funcons, corresponding sensors must be assigned to
the Delay zone. Once the delay me has been set up, the sensors will not trigger the alarm during
the delay set. Refer to the instrucons “Entry and Exit Delay” on page 10 of this manual.
Homezone
When the system is armed in Home Mode, the sensors assigned to the Home zone do not trigger an
alarm.
Controlbyphonecall
Method 1
When an alarm has been triggered, the control panel dials the stored phone numbers. When you
pick up the phone, follow the voice instrucons to control t he p anel from distance (refer to the
instrucons in the table below).
Method 2
1. Dial the telephone number of your control panel (either the number of the SIM card in your
control panel or the number of the landline to which your panel is connected). Aer geng through,
the voice instrucons will guide you to enter your access code.
2. Enter your user code, followed by ”#”.
3. A voice gives you the opons you can select.
4. Select the operaons to control the panel (see instrucons in the table below).
Note
The call will end automacally if you do not send any command within 30 seconds.
Tableofcommandsforcontrolbyphonecall
Command Function Comment
Press “1“ Arms the system
Press “0“
-Disarms the system and turns the
siren o
-Stops monitoring without hanging up
- Stops the phone call funcon without
hanging up
Press “3“ Phone call with control panel
Press "*"
- Starts audio monitoring mode (not
limited in me)
- Stops the built-in siren and the wire-
less siren (if connected to the control
panel)
-
Press “6“ Turns all sirens o -
Press “9“
- Turns the built-in siren on (whether
the siren ringing sengs is ON or
OFF)
- Turns the wireless siren on (if con-
nected to the control panel)
-
Press “#“
- Turns all sirens o
- Exits control by phone call
- Stops call recycles
-
Note
In GSM mode, the audio monitoring is not limited in me.

1716
SetupbySMS
IMPORANT:BEFORE USINGFOR THEFIRST TIME
Insert a SIM card in the control panel before starng SMS operaons.
Make sure the SIM card does not require any PIN code.
SAVE A SMS NUMBER IN THE CONTROL PANEL (using the control panel).
Only stored numbers can control and congure the system.
Each SMS operaon dened in this user manual will be illustrated as follows:
You send:
SMS Command
The control panel replies:
Control panel’s reply
.
The system is in English by default. To change the system language, refer to the instrucons
on page 22 of this manual.
Important
When replying to the control panel by SMS, make sure no space follows punctuaon marks like "."
or ":". For examples, to store SMS numbers, your SMS must be formaed as follows:
SMS numbers:
1.067890033
2.067890022
3.067890011
4.067890000
5.
No space aer "1."
Disarmthe System
Send:
System disarmed.
ArmtheSystem
Send:
System armed.
HomeMode
Send:
System in home mode.
SettingsEnquiry
Send:
System:Disarmed
AC power:on
Note
The values indicated hereinabove will change
aer having set up the system.
0
1
2
00

1918
StorePhoneNumbers
Send:
5
Phone numbers:
1.
2.
3.
4.
5.
Copy, paste, then edit
(case sensive):
Phone numbers:
1. 067890033
2. 067890022
3. 067890011
4. 067890000
5.
Ok
StorePhoneNumbersforSMS Notifications
Send:
SMS numbers:
1.
2.
3.
4.
5.
Copy, paste, then edit
(case sensive):
Ok
Note
The rst SMS number will receive SMS
nocaons when the system is disarmed by
RFID tag. To start receiving these nocaons,
you must rename the RFID tags. Up to 4 RFID tags
can be renamed. Other tags will be aributed a
number based on the order of registraon to
the control panel. Refer to the instrucons on
page 8 to learn how to register an RFID tag
in the control panel.
RenameZones
Send "91~99". For example for zone 1,
send:
91
Zones names:
1.
Copy, paste, then edit
(case sensive):
Zones names:
1.Entrance door sensor
Ok
Note
Zones 1 to 9 can be renamed. The name of
the zone cannot consist of more than 30
Latn characters. Zones 10 to 99 cannot be
renamed.
SMSAlertforAccessoryLowBattery
(available for two-way acessories such as Motion
Detectors)
For accessories assigned to zones that have
been renamed, an SMS will be sent
under the format “Zone name + low
battery”.
Bedroom PIR low baery
For accessories assigned to zones that have
not been renamed, an SMS will be sent
under the format “Zone number + low
battery”.
Zone 10 low baery.
SMSAlertforAccessoryTamper
Alarm
(available for two-way acessories such as Motion
Detectors)
For accessories assigned to zones that have
been renamed, an SMS will be sent
under the format “Zone name + tamper
alarm”.
Bedroom PIR tamper alarm.
For accessories assigned to zones that have
not been renamed, an SMS will be
sent under the format “Zone number +
tamper alarm”.
Zone 10 tamper alarm.
6
2. 067890022
3. 067890011
4. 067890000
5.
SMS numbers:
1. 067890033

2120
RenameRFIDTag
Send:
Rename RFID tag names:
1.
2.
3.
4.
Copy, paste, then edit
(case sensive):
Rename RFID tag names:
1. Tom
2. Nurse
3. Nancy
4. David
Ok
Note
The rst SMS number will receive SMS
nocaons when the system is disarmed
by RFID tag. To start receiving these
nocaons, you must rename the RFID
tags. Up to 4 RFID tags can be renamed.
Other tags will be aributed a number based
on the order of registraon to the control
panel. Refer to the instrucons on page 8
to learn how to register an RFID tag in the
control panel.
EntryandExitDelayTime
Send:
Entry delay me(0-300sec):0
Exit delay me(0-300sec):0
Copy, paste, then edit
(case sensive):
Ok
Note
This funcon can be used if you do not want to bring
a remote control or a RFID tag with you.
When you arm the system, the system will be
armed aer the delay set. When you disarm the
system, the system will be disarmed aer the
delay set.
When arming the system, you hear one beep
every second to remind you to leave. The beep
rhythm speeds up during the last 10 seconds.
If an intruder is detected, the alarm will be
delayed accordingly.
SirenVolumeandRingingTime
Send:
Siren volume(0=Mute,1=High):1
Siren ringing me(1-9min):3
Copy, paste, then edit
(case sensive):
Ok
DisarmPassword
Send:
Disarm password (4 digits):
1234
Copy, paste, then edit
(case sensive):
Disarm password (4 digits):
4321
Ok
131210 11
Entry delay me(0-300sec):10
Exit delay me(0-300sec):20
Siren volume(0=Mute,1=High):0
Siren ringing me(1-9min):5

2322
ChangeSystemLanguage
Send the code corresponding to the
language you want to set. For example,
for English, send “0001”.
0001
Ok
Refer to the table below for the full list of
languages:
0001 English
0002 French
0003 German
0004 Italian
Languages available may vary depending on
the version of your product.
RestoreSystemtoFactorySettingsbySMS
Send:
Ok
The sengs will be restored to default values.
Stored phone numbers and connected
accessories will not be deleted.
Note
Only stored numbers can send the SMS to
restore factory sengs.
Accessories
WirelessRemoteControl
Home Mode
Arm
SOS
Disarm
LED indicator
Armthesystem
Press the Arm button " " to arm the alarm
system. The LED indicator lights up (the
control panel beeps once). The system is
armed.
If an intruder is detected, the siren rings out.
(The siren turns o aer 5 minutes as per
default sengs.) In the meanme, the system
dials the stored phone numbers automacally.
Disarmthesystem
Press the Disarm button " " to disarm the
alarm system. The LED indicator turns off (the
control panel beeps twice). The system is
disarmed.
HomeMode
Press the Home Mode buon " " on the
remote control. The system state LED is on.
All the sensors in regular zones are armed
except those in the Home Mode zone.
The sensors in the Home Mode zone are
disarmed so that users can move inside their
home.
0000

2524
MuteMode
Press the Home Mode buon " " and
then the Arm " " or Disarm " " buon
immediately aer. Doing so, the control
panel does not beep when you arm or disarm
your system.
EmergencyMode
Regardless the status of the system, the
alarm is triggered when the SOS button "SOS"
is pressed on the remote control.
At the same time, the control panel sends a
notification by SMS ("RC-01 SOS", 01 being
the remote control's number) and dials the
pre-stored phone numbers.
Registerinthecontrolpanel
Refer to the instructions in the table on page 8 of this manual "Remote & Keypad".
Specicaons
Power supply
DC 3V (CR2025 buon baery x1)
Static current
≤10 uA
Operating current
≤7 mA
Transmission distance
≤ 80 m (in open area)
Radio-frequency:
433MHz (±75KHz)
Housing material
ABS plasc
Operating conditions
Temperature: -10°C ~ +55°C
Relave Humidity: ≤80%
(non-condensing)
Dimensions
57 x 31 x 11 mm
WirelessMotionDetector
Design
3
1
2
1. LED indicator
2. Detecon window
3. Bracket
LEDindicaons
Blinksconnuously: self-tesng
Blinksonce: an intruder is detected
Blinks twice: self-tesng is complete;
entering working mode.
Blinks once every 3 seconds: under-
voltage indicaon, the baeries must be
replaced. (You will be informed by SMS
when the baeries are low if the moon
detector is registered in the control panel.)
PCBLayout
Alarm zone
setup
Tamper
switch*
Infrared
sensor**
AA 1.5V LR6
Antenna
LED working
indicator
* Tamper switch
When the alarm system is armed, the tamper switch will trigger the alarm if the case is opened.
**Infrared sensor
Detects the infrared rays released by human body moon. Do not touch the surface. Keep the surface
clean.

2726
Usage
Open the case and remove the baery acvaon
strip. Self-tesng will start for 30 seconds.
When the sensor is in operaon, if it is triggered
more than twice within 3 minutes, it will switch
to standby mode to save power. If no movement
is detected within the next 3 minutes, the sensor
goes back to working mode.
Connect Button
Registerinthecontrolpanel
Navigate through the menu of the control panel and reach "ADD A NEW" (Wireless Sensor).
Press the Connect button at the back of the motion sensor or trigger the sensor (by moving in
front of it) to register the detector in the control panel.
Installaon
Avoid mounng the detector close to windows, air condioner, heater, refrigerator, oven,
sunshine and places where the temperature changes fast or where the air stream ows
frequently.
If two detectors are installed in the same detecon scope, adjust the locaon to avoid interferences
and false alarms.
Fix the bracket on the wall with
screws and aach the detector to the
bracket. Adjust the bracket to change
the detecon distance and angle. It is
recommended to mount the detector
2.2 m from the ground.
Top
Boom
Ground
2.2 m
The detector is more sensive to cross
movements than vercal movements.
Side view
Top view
Tesng
A. Aer the installaon, turn the detector on. Aer one minute of self-tesng, press the test
buon, walk in the scope of detecon and watch the LED indicator to make sure the detector
is working.
B. The LED indicator blinks once when body movement is detected.
C. Adjust the detector angle to achieve the best detecon performance.
Specicaons
Power supply
DC 3V (AA 1.5V LR6 Baeries x 2)
Static current
≤ 30uA
Alarm current
≤ 15 mA
Detection scope
8m / 110°
Transmission distance
≤ 80m (in open area)
Radio-frequency
433 MHz (±75 KHz)
Housing material
ABS plasc
Operating conditions
Temparature: -10°C~55°C
Relave humidity: ≤ 80% (non-condensing)
Detector dimensions (L x W x H)
107 x 53 x 32 mm
Bracket dimensions (L x W x H)
52 x 30 x 26.5 mm
DeteconScope
110°
Top view
0m 2m 4m 6m 8m
2m
0m
Side view

2928
WirelessDoor/WindowContact
Features
This Door / Window Contact can be installed on doors, windows, and any other objects that
open and close. The sensor sends a signal to the control panel when the magnet is separated
from the transmier.
Thanks to the tamper switch, any aempt to remove the cover of the Door / Window Contact
will trigger the alarm.
Design
Magnet
Transmitter
LED indicator
PCB Layout
LED working indicator
Zone setting
A23 12V battery
Tamper switch
LEDindicaons
Blinksonce: the door or window is open and the transmier sends a signal to the control panel.
Blinksquickly: Low power indicaon, the baeries must be replaced.
Registerinthecontrolpanel
Navigate through the menu of the control panel and reach "ADD A NEW" (Wireless Sensor).
Then separate the magnet from the transmitter to register the detector in the control panel.
To check if the registraon is complete, arm the system and separate the magnet from the
transmier again by opening the door or window on which it is installed. If the siren rings out,
the registraon is successful.
Installaon
- Open the case and remove the baery acvaon strip.
-Mount the sensor on the door and the magnet on the
door frame.
-Make sure the magnet is placed above the transmier.
-Mount the magnet max. 1 cm away from the transmier
and secure the transmier and magnet with double-sided
tape or screws.
-Avoid mounng the sensor in areas with a large amount of
metal or electrical wiring such as a furnace or ulity room.
Specicaons
Power supply
DC 12V (A23 12V Baery x 1)
Static current
≤ 30 uA
Alarm current
≤ 15 mA
Transmitting distance
≤80 m (in open area)
Radio-frequency
433 MHz (±75 KHz)
Housing material
ABS plasc
Operating conditions
Temparature: -10°C~55°C
Relave humidity: ≤ 80% (non-condensing)
Transmitter dimensions (LxWxH)
60 x 45 x 18 mm
Magnet dimensions (LxWxH)
45 x 19 x 17.5 mm

3130
RFIDTag
Features
The RFID tag enables you to disarm your system or unlock electronic door locks.
Registerinthecontrolpanel
Refer to the instructions in the table page 8 of this manual (“RFID TAG”).
Specicaons
Dimensions
45 x 30 x 7 mm
Troubleshootingandmaintenance
FAQ
Issue Cause of malfunction Solution
No response following
interacon with the
control panel
The control panel is switched o Open the baery compartment and
turn the power on
Electricity grid failure Contact your electricity provider
Backup baeries are empty Plug the AC adapter to an AC socket
Accessories cannot
connect to the control
panel
The control panel is not in
Connecon mode
Make sure the control panel is in
Connexion mode
Accessories have not been
triggered for connecon
Make sure the accessory is triggered so
to send a signal to the control panel
When aempng the
connecon, the control panel
beeps twice
The accessory has already been
connected
Make sure you do not trigger any
other accessory when connecng one
accessory to the control panel (e.g. do
not stay in the detecon scope of a
moon detector if it is not the one you
want to connect)
No response from the
control panel following
commands from the
remote control
The remote control has not been
connected to the control panel
Follow the instrucons in this manual
to connect the remote control to the
panel
Remote control is too far from
the control panel
Transmission distance of the remote
control: 80 m (in open area)
A signal repeater can be installed to
increase the transmission distance
RFID tag fails to disarm
the system
RFID tag has not been connected
to the control panel
Follow the instrucons in this manual
to connect the RFID tag to the control
panel
Impossible to access
sengs from the control
panel
You are not in the setup menu of
the LCD display
Enter your admin code followed
by “Enter“ to enter the setup
menu

3332
Precautions
For a safer use of the product and to opmize the lifespan of the product, we recommend you
to follow the precauons below:
- The wireless accessories must be connected to the control panel.
- Low power voltage may affect transmission distance.
- Do not press the SOS key on the remote control if it is unnecessary to avoid
disturbing neighborhood.
- Check the system regularly to make sure the system works properly.
- The control panel is neither waterproof nor moisture-proof, install it in a shady,
cool and dry place.
- The case of the control panel is made of ABS plastic. Keep away from bright light for
a longer lifespan.
- The control panel is not explosion-proof. Keep away from fire and flames.
- Install the control panel away from objects such as heater, air conditioner,
microwave oven etc. that generate heat or electromagnetic fields.
- Dispose of the batteries according to local regulations.
- Dismantling of this product must be done by professional personnel only.
Standards
This product bears the selecve sorng symbol for waste electrical and electronic equipment
(WEEE). This means that this product must be handled pursuant to European Direcve
2002/96/EC in order to be recycled or dismantled to minimize its impact on the environment.
For further informaon, please contact your local or regional authories.
Electronic products not included in the selecve sorng process are potenally dangerous for the
environment and human health due to the presence of hazardous substances.
In compliance with European laws. This product is in compliance with the essenal requirements
and other relevant provisions of Direcve 1999/5/EC.
This product was designed and manufactured in compliance with Direcve 2002/95/EC of the
European Parliament and of the Council on the restricon of use of certain hazardous substances
in electrical and electronic equipment (RoHS Direcve - RoHS) and is deemed to comply with
the maximum concentraon values set by the European Technical Adaptaon Commiee (TAC).
Manufactured in China.
ST-SK1-C-UM-EN20141120-1.0-W

ELBRO AG, Gewerbestrasse 4,
CH-8162 Steinmaur,
Switzerland
www.elbro.com
Other ELBRO Security System manuals
Popular Security System manuals by other brands

DMP Electronics
DMP Electronics 265HINT installation guide

Energeeks
Energeeks EG-AW004PROMO Quick installation guide

INIM
INIM snartliving user manual

Politec
Politec MANA MW INSTALLATION AND MOUNTING MANUAL

Honeywell
Honeywell LYNX Touch Security System user guide

Honeywell
Honeywell XC70 Operating and installation instructions

Gemini
Gemini 953 Installation and use manual

GIZMO ENGINEERING
GIZMO ENGINEERING IS-AB manual

Teletek electronics
Teletek electronics SF 120 installation manual

ADEMCO
ADEMCO Counterforce CFV15P Programming guide

X10
X10 PK9000 Set up and operating instructions

Fike
Fike TWINFLEX 313-0021 Installation and maintenance instructions