Eldat Easywave RTS40 User manual

Models
A
O
I
RTS40E5001B01
AUTOMATIC
A
O
I
RTS40E5001B02 ON/OFF/AUTO
Technical Details
Frequency: 868.30 MHz
Radiated power: 0.89 mW
Modulation: FSK
Coding: Easywave A/B
EasywavePlus
POTA
Power supply: 1x 3V battery, CR2032
Temperature: -20 °C to +60 °C
Range: free-eld: approx.150 m
buildings: approx.30 m
Brightness range: 1 lx to 150 lx
After-run time: 5 s to 131 min
Inspection density: approx. 16 m²
Dimensions (w/l/h):
cover: 55 / 55 / 12 mm
plate: 71 / 71 / 1.5 mm
Weight: 30 g
Scope of Delivery
Transmission module, batteries CR2032, cover,
mounting plate, adhesive pad, operating instruc-
tions
Motion Detector RTS40
EN
Intended Use
Only use the device as a motion detector and only
for operating Easywave radio receivers.
The manufacturer shall not be liable for any
damage caused by improper or non-intended
use.
Safety Advice
Before using the Radio Wall Switch,
carefully read through the operating in-
structions!
Also note the operating instructions for the
receiver(s)!
Do not make any unauthorised alterations or
modications to the RadioWall Switch!
Have faulty Radio Wall Switches checked by
the manufacturer!
Keep the batteries out of the reach of children!
Function
The RTS40 is a battery-operated wireless moti-
on detector for indoor use. Movement is detected
and information sent via an Easywave message,
and the connected Easywave radio receivers
are operated in line with their selected operating
mode. Motion detection can optionally also be
brightness-dependent.
There are two device options available:
AUTOMATIC operation (RTS40E5001B01)
The motion detector automatically reacts as per
the programmed values.
ON/OFF/AUTO operation (RTS40E5001B02)
The function of the motion detector can be ope-
rated as permanently ON (button I), permanently
OFF (button O) or on automatic operation (A
button).
After-run time
The motion detector sends an ON data telegram
(A) when it detects a movement and an OFF data
telegram (B) after the adjustable after-run time
has elapsed. The after-run time can be set to a
period ranging from 5 seconds to 131 minutes.
For this purpose, set the number of seconds (in
steps of 5) via the “SEC x5“ setting and the desi-
red number of minutes via the “MIN“ setting. As
an option, the after-run time set in this way can
be multiplied by a factor of 1 to 11 via the time
multiplier “x“.
The after-run time can be re-triggered. If another
movement is detected during the after-run time,
the after-run time starts again from the beginning.
In doing so, the light sensor is not evaluated.
Light sensor
The motion detector has a switchable light sensor.
As soon as the light sensor is activated, detected
movements only trigger a switching command if
the measured brightness is below the adjustable
brightness threshold.
The brightness threshold can be set in 12 steps,
ranging from 1lx to 150lx.
When re-triggering the after-run time, the light
sensor is generally not evaluated, as the switched
light source usually has an inuence on the value
measured.
Trigger function
The trigger function is used to control automatic
staircase lighting systems or the TIMER function
of Easywave receivers.
To select the trigger function, set the multiplier x to
0(see “Programming“ on page 3). In this mode,
the motion detector sends a data telegram (A) to
the receiver every time motion is detected. To-
gether with the corresponding Easywave recei-
vers, this data telegram can be used to re-trigger
the TIMER function or e.g. an automatic staircase
lighting system.
In this mode, the set after-run time species the
minimum interval between two transmission pro-
cesses. If the after-run time is set to 2 minutes
and 30 seconds, e.g. the motion detector trans-
mits a signal a maximum of every 2.5 minutes as
long as motion is detected. If no motion is detec-
ted after the after-run time has elapsed, no data
telegram is transmitted. The transmission interval
can be a minimum of 5 seconds and a maximum
of 11:55 minutes.
The light sensor can be used normally in this
mode. To deactivate the trigger function, set the
multiplier to a value > 0 (1-11).

START-UP
PROGRAMMING
Figure 2
A Cover
B1Transmission module front
B2Transmission module back
PTx Learning button (POTA)
C Battery CR2032
D Cover frame
(Not in the delivery scope)
E Mounting plate
F Catches
G Easywave radio receiver
A
A
O
I
G
A
O
I
B1
D
E
F
0 2CR2 3
+
B2
C
PTx
P
PTx
TX
x
SET
W F
MIN
SEC x5
11
10
9
8
7
6
5
4
3
2
1
0
P
PTx
TX
x
SET
W F
MIN
SEC x5
11
10
9
8
7
6
5
4
3
2
1
0
B1
B2
General information (Figure 1)
The motion detector is equipped with a PIR sen-
sor and suitable for ceiling and wall installation.
The sensor reacts to changing heat radiation. The
motion detector should therefore not be installed
near heat sources, air currents or objects that
move.
The distance between the installed object and
light sources should be at least 0.5 m.
No heat radiation is detected through barriers
(walls, glass panes, etc.).
Make sure there is no interference with the wire-
less connection. Do not mount the device in a dis-
tribution box, in metal casings, in direct proximity
to large metal objects, on the oor or close to it.
The motion sensor is ready for operation 10 se-
conds after the battery is inserted.
Mounting (Figure 2)
1. Screw or stick the mounting plate (E) to the
installation site.
2. Insert the enclosed battery (C) in the transmit-
ter module (B).
The positive pole has to be visible!
3. Programe the transmission code in the
receivers (G). For this, set the receive to
learn mode. Please read the operating
instructions supplied with the receivers.
Now press the Wbutton (Easywave code A)
or F(Easywave code B) on the transmitting
module (B). Set the required time and bright-
ness settings or use the factory settings (see
“Settings”)
4. Place the cover frame (D) on the mounting
plate (E), latch the transmitting module (B)
onto the snap arm (F) and clip the cover (A)
onto the transmitter module (B).
Figure 1
Start the programming mode by pressing the pro-
gramming button P. The programming button is
located under the cover on the motion detector
(see gure 2). The current after-run time is paused
and the settings for the motion detector can be
changed.
Select the function to be set with the F button and
then the desired value with the W button.
To save the settings made (see the table on pg.
3), exit the programming mode using the SET
button.
The after-run time is restarted with the current
settings.
The programming stops after 30 seconds have
elapsed without pressing the button or by pressing
the programming button P again.
This discards all the settings made and the previ-
ous after-run time applies again.
Each time you exit the programming mode, the
motion detector ignores all motions for ve se-
conds and only becomes active again after this
switching delay. In this way, the detection range
for the motion detector can be exited after pro-
gramming without triggering it.
The RTS40 is preset ex-factory as follows:
- Light sensor deactivated.
- After-run time of seven minutes.
~
4.0 m
~
4.0 m
~
3.0 m
~
3.0 m
~ 4.0 m
~
4.0 m
ceiling mounting wall mounting

Function Operation
[press the button]
LED view Comment
Set after-run time in seconds SEC x5 Set follow-up time in 5-second steps (max. 55 s)
1. P Button LED W+F light up in
accordance with the default
settings
30 seconds after after-run time the nal time you
activate the button, there is automatic break-o
select the
function
2. F Button until the LED SEC x5 lights
set the
value
3. W Button LEDs W0 to W11 lights
in accordance with your
selection
in steps of 5 seconds
(W0 = 0 s, W1 = 5 s, W2 = 10 s ... W11 = 55 s)
If 0 minutes are set, the smallest possible after-
run time of 5 seconds applies to the W0 setting.
4. SET Button Selection saved
Set after-run time in minutes MIN Set follow-up times in minutes from 1 min to 11 min
1. P Button LEDs W+F light up in
accordance with the default
settings
30 secondsafter after-run times the nal time you
activate the button, there is automatic break-o
select the
function
2. F Button until the LED MIN lights
set the
value
3. W Button LEDs W0 to W11 lights
in accordance with your
selection
in steps of 1 minute
(W0=0 min, W1=1 min, W2=2 min ... W11=11 min)
4. SET Button Selection saved
Set the time multiplier X The progammed after-run time (minutes + seconds)
x factor required (1 to 11)
max. time: 11 x (55 s+11 min) = 131 min (2 h+11 min)
1. P Button LEDs W+F light up in
accordance with the default
settings
30 seconds after the nal time you activate the but-
ton, there is automatic break-o
select the
function
2. F Button until the LED Xlight
set the
value
3. W Button LEDs W1 to W11 lights
in accordance with your
selection
set time x factor required
(W1 = x1, W2 = x2 ... W11= x 11)
(W0 = Trigger function, see page 1)
4. SET Button selection saved
Activate/deactivate light sensor If the light sensor is switched o, the motion detector
operates independently of the selected brightness
value.
1. P Button LEDs W+F light up in
accordance with the default
settings
30 seconds after the nal time you activate the but-
ton, there is automatic break-o
select the
function
2. F Button until the LED lights
3. WButton LED W4 lights: Sensor ON
LED W4 o: Sensor OFF
4. SET Button Selection saved
Setting the brightness threshold Set the brightness value below which the motion
detector should operate.
1. P Button LEDs W+F light up in
accordance with the default
settings
30 seconds after the nal time you activate the but-
ton, there is automatic break-o
select the
function
2. F Button until the LED lights LED W, blinking, shows the currently measured
brightness
set the
value
3. W Button LEDs W0 to W11 lights
in accordance with your
selection
W0 to W11 = 1 lx to 150 lx
4. SET Button Selection saved
PROGRAMMING
Internal control buttons
P
PTx
Tx
x
SET
SET
WF
FW
MIN
SEC x5
11
10
9
8
7
6
5
4
3
2
1
0
ABB
PProgramming button
WButton W: set the values or
transmission code A
LED W: show selected value
FButton F: select the function or
transmission code B
LED F: show selected function
SET Save the chosen settings
The Tx LED lights up red during a
transmission process when a button is
pressed.
External control buttons (only RTS40E5001B02)
ABB
AOI
Button ISwitch load ON
(transmission code A)
The motion detector is deactivated
Button OSwitch load OFF
(transmission code B)
The motion detector is deactivated
Button AAutomatic operation
The motion detector is activated
(switching delay 5 seconds)
(transmission code B)
Any number of settings can be changed
at the same time and then saved with the
SET button.

Disposal
Waste electrical products should not be
disposed of with household waste!
Dispose of the waste product via a coll-
ection point for electronic scrap or
via your specialist dealer.
Put the packaging material into the
recycling bins for cardboard, paper
and plastics.
Warranty
We will remedy defects on the device based on
material or production errors or exchange the de-
vice within the statutory warranty period.
Any unauthorised tampering with, or modications
to, the product shall render this warranty null and
void.
Conformity
ELDAT EaS GmbH hereby declares that the ra-
dio equipment type RTS40 is in compliance with
Directive 2014/53/EU. The full text of the EU de-
claration of conformity is available at the following
internet address: www.eldat.de
Customer Service
If the device does not work properly despite pro-
per handling or in case of damage, please contact
the manufacturer or your retailer.
ELDAT EaS GmbH
Schmiedestraße 2
15745 Wildau
Germany
Phone: + 49 (0) 33 75 / 90 37-310
Fax: + 49 (0) 33 75 / 90 37-90
Internet: www.eldat.de
Email: [email protected]
UM500350_0723 EN
POTA learning button
The POTA learning button PTx is located on the
back of the device.
With the remote learning function POTA (Pro-
gramming Over The Air), it is possible to program-
me a receiver that is already installed and can no
longer be accessed, if it supports this function. All
that is needed is a POTA-capable transmitter that
is already taught-in. Only the Wand F(or I& O)
buttons can be used for the POTA functions!
A detailed POTA programming manual is available
on our website:
https://www.eldat.de/pota_en.pdf
or you can request support from our customer
service.
Battery check
The transmitter has a battery check function,
which checks the capacity of the battery during
the transmission process.
After completing the transmission process, an un-
dervoltage data telegram is automatically sent if
the battery is runs out. In addition, the light around
the sensor ashes red for approx. 3 seconds in
this case.
When this happens, change the battery for the
motion detector immediately to ensure full func-
tionality.
The undervoltage data telegram can be evalua-
ted using suitable Easywave receivers. For more
information, please refer to the operating instruc-
tions for the respective receiver.
Trouble shooting
If the controller does not react to the motion de-
tector:
- Replace the battery.
- Check that the wireless connection at the
installation site is not impaired between the
transmitter and the receiver.
- If necessary, re-programme the transmission
code into the receiver.
- Other wireless devices using the same fre-
quency and working in direct proximity may
interfere with the device.
- With the RTS40E5001B02, ensure that the
automatic mode is active. If necessary, press
the Abutton to switch to automatic mode.
GENERAL INFORMATION
Other Eldat Security Sensor manuals