Elecro Engineering Thermecro Solar Installation instructions

Thermecro Solar
Digital Controller
Installation & Operating Manual

ENGLISH
www.elecro.co.uk

ENGLISH
1
www.elecro.co.uk
Important Notes
Congratulations on purchasing the Thermecro pool & spa heating system,
the latest in advanced solar technology, manufactured in England to the
highest standards.
To ensure your new product will give years of trouble free service please
carefully read the following instructions.
Incorrect installation will aect your warranty. Do not discard this
manual, please retain for future reference.
Important safety information
• Consult a qualied electrician
• Always isolate the unit from mains electricity and turn o the water
supply before carrying out maintenance
• Always disconnect all pool appliances from the mains electricity supply
before servicing
• The unit must not be submerged in water
• Young children should always be supervised near water
• Not to be used by persons with reduced physical, sensory or mental
capabilites or lack of experience and knowledge, unless they have been
given supervision or instruction.
Specication
Model: SR-DC
Rating: 220V~250V 50/60Hz
This unit is CE approved.

www.elecro.co.uk
Weather Protection
The digital controller must be installed within a dry weather proof enclosure
or building.
Mounting
Hole centres for mounting:
Wiring Connection Details
This equipment must be installed
in accordance with the country/regional
requirements and regulations. This
equipment must be installed by a qualied
electrician who will provide a certicate
of conformity upon completion of the work.
2
ENGLISH
www.elecro.co.uk

3
www.elecro.co.uk
ENGLISH
Remove the four xing screws and cover to access the cable terminal
block for connection of the cables. The cables should be inserted through
the cable glands and connected to the terminal block, tighten the cable
glands after the connections have been made.
Wiring Diagram
NOTE- The pump output is a signal only
to override the existing time clock and/
or contactor currently controlling the
pump. DO NOT connect the ltration
pump directly to terminals 3 and 4 as this
will overload the controller and cause it
to fail.

www.elecro.co.uk
Overview
Overview
Language Setting
The factory default setting for the language is English.
To change to another language, press the / buttons until the
desired language appears, press OK to select and save.
DIGITAL DISPLAY
BUTTONS LED INDICATOR
4
ENGLISH

5
www.elecro.co.uk
To select a mode press the / buttons until the desired mode is
displayed then press the OK button to select that mode.
Set Water Temperature
Use the / buttons to select the desired swimming pool tempera-
ture. Then press OK to conrm and save.
NOTE - We suggest you set the required temperature on your traditional
heater (electric, gas, heat pump) to 1°C or 2°C below the ‘Set Water Temp’
selected. This will ensure your system will operate as eciently as possible.
Set Up Modes
The Digital controller displays the solar water temperature and the pool
water temperature. There are four modes for the set-up of your solar
system i.e:
• SET WATER TEMPERATURE
• ON DIFFERENTIAL TEMPERATURE
• OFF DIFFERENTIAL TEMPERATURE
• FILL SYSTEM
ENGLISH

www.elecro.co.uk
On Dierential Temperature
This mode is user adjustable between 2°C and 60°C, the factory default is 10°C.
‘On Dierential’is the temperature dierence between your Thermecro solar
array and swimming pool water. When the‘On Dierential’value is reached, the
electronic stainless steel valve opens to allow the heated water back to your
swimming pool. The‘On Dierential’value can be changed to optimise the heat-
ing process according to the prevailing climatic and other inuencing conditions,
however, under most circumstances when ‘On Dierential’ is set to a value be-
tween 10 - 12ºC this will provide the best all round seasonal heating performance
in most climates.
To set the‘On Dierential Temperature’press the / buttons until this mode
appears on the display and O.K. to select. Press the / buttons to set the
required temperature and then press the O.K. button to save that value in the
memory.
6
ENGLISH
O Dierential Temperature
This mode is user adjustable between 1°C and 49°C the factory default is 2°C.
‘O Dierential’ is also the temperature dierence between your Thermecro solar
array and swimming pool water. When the‘O Dierential’ value is reached, the
electronic stainless steel valve closes, allowing the solar array to begin the
heating process again.

7
www.elecro.co.uk
Fill System
Upon completion of the installation of the Thermecro solar array and pool
interface valve, it is necessary to initially ll the array.
To ll the solar array press the / buttons until ‘Fill System’mode
appears on the display press O.K. this turns the ltration pump and the
electronic valve‘On’ (see diagram 1 and 2).
When the array is fully purged of air (i.e. no bubbles are being returned to
the pool), press the O.K. button again to select‘Stop Fill’ this switches the
electronic valve and ltration pump o (see diagram 3).
1
ENGLISH
2 3

Operation
The Thermecro digital controller is designed for use with the Themecro pool
interface valve to facilitate the harvesting of heat from the solar array in the
most ecient way possible.
The solar array water temperature and pool water temperature are
measured continuously.
When the solar array temperature is greater than the‘set water temperature’
+ the‘on dierential temperature’the controller will open the stainless steel
valve to allow the heated water into the pool.
Example:
Set Water temperature = 28°C
On Dierential = 10°C
The valve will be opened when 38°C is detected in the array.
The valve will remain open, delivering heated water to the pool until the‘Set
Water Temperature’is achieved or the temperature within the solar array has
fallen to the‘O Dierential’value
Example:
Set Water Temperature = 28°C
O Dierential = 2°C
The valve will close when 30⁰C is detected in the array.
www.elecro.co.uk
8
ENGLISH

9
RoHS Compliance Statement
Elecro Engineering Limited certify that our Thermecro Solar Digital
Controller complies in accordance with RoHS Directive 2011/65/EU on the
restriction of hazardous substances.
Waste of Electrical / Electronic Equipment
This product complies with EU directive 2012/19/EU
Do Not dispose of this product as unsorted municipal waste.
This symbol on the product or on it’s packaging indicates that this product
should not be treated as household waste. Instead it should be handed
over to the applicable collection point for the recycling of electrical and
electronic equipment.
By ensuring this product is disposed of correctly you will
help prevent potential negative consequences for the
environment and human health, which could otherwise be
caused by inappropriate waste handling of this product.
The recycling of materials will help to conserve natural
resources.
For more information please contact your local Civic oce,
your household waste disposal service or the retailer
where you purchased the product.
Guarantee
Your digital controller is guaranteed for 3 years from the date of purchase
against faulty workmanship and materials.
The manufacturer will replace or repair, at it’s discretion, any faulty units or
components returned to the company for inspection.
Proof of purchase may be required. The manufacturer will not be liable in
cases of incorrect installation of the product, inappropriate use, or neglect.
www.elecro.co.uk
ENGLISH

11 Gunnels Wood Park |Stevenage |Hertfordshire |SG1 2BH |United Kingdom
t: +44 (0) 1438 749 474 |f: +44 (0) 1438 361 329 |e: sales@elecro.co.uk
www.elecro.co.uk
© Copyright 2017 Z-INS-SR-DC
This manual suits for next models
1
Table of contents
Other Elecro Engineering Controllers manuals
Popular Controllers manuals by other brands

Monacor
Monacor CU-3MINI instructions

Rain Bird
Rain Bird ESP-4 Installation, programming, & user manual

Tescom
Tescom 26-1700 Series Instructions for use

Lambario
Lambario LY30-01130 user manual

DeLUX
DeLUX MOISTURE Link G2 MSF Operation manual

Siemens