Oct. 18, 1991
TYPE 99A-DF
INSTALLATION & OPERATIONS MANUAL
MANUAL #115
Attachments A-4381 & A-4220
INSTALLATION
1. Disconnect power to any circuit(s) which you will be wiring to, or you may come in contact with.
2. Install the electrical enclosure to the wall by drilling through the 4 marked holes in the back.
3. Wire the input power, clock circuit and optional illumination circuit to the terminal strip, per attached Drawing A-4381,
following your local and national electric codes.
4. Set the tower & system clocks to 12:00 noon.
5. Energize the clock system.
NOTE: The clock control will be set to the proper local time and the system clock counter
set to 12:00 noon by the factory. If not follow set:TIME & set:HANDS below.
6. LED display should read the correct time & date; if not, see how to set:TIME below.
7. Tower and system clocks should be advancing or stopped, or reading the correct time; if not, see how to set:HANDS below.
OPERATION
Unlock the control by pressing "*" & "1" at the same time. The display will then read "-unlock-" momentarily. After you have
finished using the control, lock it by pressing "*" & "1" again, the display will then read "locked" momentarily.
Page through functions by pressing "*" key. Access funtion by pressing"#".
FUNCTION
set:TIME Enter the current time in the form HH:MM using the keypad, use "#" to alternate between "AM" and "PM",
press "*" when done.
Note: when "*" is pressed, the clock second counter is reset to zero, i.e. 11:59:00.
set:DATE Enter the current date in the form MM/DD/YY. Then select the day using the "#" to scroll through the display,
press "*" when done.
Note: it is important the day of the week is set properly for the daylight/standard
time feature to work properly.
set:MODE Allows you to select if you wish seconds to be displayed on the LED display. Use the "#" to alternate between
show min & show sec. Press "*" when complete.
set:EVENT Allows programmable "ON" & "OFF" times of the optional illumination circuit. Enter the time you desire the
illumination to turn on, and the time you wish the illumination to turn off, following the steps for set:TIME
above. NOTE: This feature may be disabled or enabled, press "#" to alternate and "*" when complete.
man:EVENT Allow manual control of the event circuit. Press "#" to alternate between "event on" & "event off", press "*"
when complete.
adv:CLK Allows manual advancing of the tower clocks. When selected advances the tower clocks, press "*" when complete.
Note: The internal tower clock counter is not updated when this feature is selected.
Therefore set:HANDS must be always be done afterwards.
stop:CLK Allows manual stop of the tower clocks. When selected stops the tower clocks, press "*" when complete (be sure
to set:HANDS afterwards -see note above).
set:HANDS Allows you to enter the current position of the clock hands on the tower clock. When this function is selected by
pressing "#", the tower clocks will stop. Enter the time using the keypad. If you make a mistake you must re-
enter the time.
If you encounter any problems installing or programming this master clock please contact us;
Electric Time Company, Inc.
45 West Street
Medfield, MA 02052
Telephone 508/359-4396
FAX 508/359-4482
Configuration Settings (0 = no jumper, 1 = jumper in)
Jumper 1: (U16 pin 1 to pin 16) Selects dual frequency
Jumper 2: (U16 pin 2 to pin 15) Selects DST disabled
Jumper 3: ( etc.) Selects internal timekeeping (NOTE: this is a future option)
Jumper 4: Use 12:00am sync pulse
Minimum of 3/4 long
Jumper 5: Selects split phase drive logic (NOTE: Jumper 1 must not be installed for
correct 10x speed reset)
Jumper 6: Select 50 Hertz Input
Note: when Jumper 4 is in Jumper 2 should also be in.
Jumper 7: Display Blanksafter 20 Seconds
Jumper 8: Minute Impulse Through Stepper Board
Secondary Jumpers (Labeled on board)
Jumper 1 Changes Illumination Circuit
Pins 7 and 8 from lighting
circuit to hourly/12 hourly
correction circuit
NOTE OUTPUT IS 115VOLTS
AND EVENT CIRCUIT MUST
BE DISABLED
Jumper 2 Illumination relay becomes output for
minute impulse system.
Shipping Weight is 18" x 18" x 9" (45.72cm x 45.72cm x 22.86cm) and weight is 13 (5.9kg) lbs.
Note: when Jumper 2 is in Jumper 8 should also be in.
Power Consumption:
Assuming no external loads and (4) RCM-C1 Motors
Normal =15 watts
Reset =27 watts
e:\M115
Revision History
Revision A. May 1, 1991 Added Jumper 5
Revision B. May 12, 1993 Added hourly/12hour jumper
Revision C. February 21, 1994 Added Power Comsumption
Revision D. March 18, 1995 Added Jumpers
Revison E. August 22, 1995 Corrected Step 5

Other Electric Time Controllers manuals

Electric Time 99B-MI User manual

Electric Time

Electric Time 99B-MI User manual

Electric Time TBX User manual

Electric Time

Electric Time TBX User manual

Popular Controllers manuals by other brands

GE C30 instruction manual

GE

GE C30 instruction manual

Novus N2000 instruction manual

Novus

Novus N2000 instruction manual

Sit 610 AC3 quick start guide

Sit

Sit 610 AC3 quick start guide

Siemens Synco 200 Commissioning Guide

Siemens

Siemens Synco 200 Commissioning Guide

SIIG USB SoundWave 7.1 Pro Quick installation guide

SIIG

SIIG USB SoundWave 7.1 Pro Quick installation guide

Emerson ECD-002 instruction sheet

Emerson

Emerson ECD-002 instruction sheet

Honeywell T775U 2000 Series installation instructions

Honeywell

Honeywell T775U 2000 Series installation instructions

Lite-Puter EDX-B02D user manual

Lite-Puter

Lite-Puter EDX-B02D user manual

Sentry AutoVREL Installation, operation and maintenance manual

Sentry

Sentry AutoVREL Installation, operation and maintenance manual

E.NEXT e.control.v04m user manual

E.NEXT

E.NEXT e.control.v04m user manual

IAI ROBO Cylinder RCP2 Series quick start guide

IAI

IAI ROBO Cylinder RCP2 Series quick start guide

Carlisle Binks 85-441 Service manual

Carlisle

Carlisle Binks 85-441 Service manual

Curtiss-Wright EXLAR GTX Series Installation & service instructions

Curtiss-Wright

Curtiss-Wright EXLAR GTX Series Installation & service instructions

CKD EBS-M Series instruction manual

CKD

CKD EBS-M Series instruction manual

Circuitron TC-1 quick start guide

Circuitron

Circuitron TC-1 quick start guide

SUPMEA Turbidity/TSS/MLSS user manual

SUPMEA

SUPMEA Turbidity/TSS/MLSS user manual

Sonnet TEMPO SATA E2P quick start guide

Sonnet

Sonnet TEMPO SATA E2P quick start guide

Siemens GEB-1E Series Mounting instructions

Siemens

Siemens GEB-1E Series Mounting instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.