Electric Time TBX User manual

M209B
04-23-04 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com
TBX
Thermometer / Barometer System
USER’S MANUAL
616TA

QUICK START GUIDE ..........................................................................
WIRING DIAGRAMS..............................................................................
INTRODUCTION ...................................................................................
SPECIFICATIONS .................................................................................
TERMINAL COMPARTMENT LAYOUT.................................................
FEATURES..............................................................................................
OPERATION...........................................................................................
DEVICE ADDRESSES............................................................................
TROUBLESHOOTING............................................................................
CALIBRATION PROCEDURE................................................................
SERVICE.................................................................................................
M209B
Pg.2of12
TABLE OF CONTENTS
3
6
6
7
8
8
9
10
11
12
A-5661
04-23-04 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

QUICK START GUIDE
1) DISCONNECT 115VAC POWER CIRCUIT BEFORE
MAKING ANY WIRING CONNECTIONS
2) INSTALL ALL THERMOMETER OR BAROMETER
DIALS
3) INSTALL TBX CONTROLLER IN ACCESSIBLE
LOCATION (#10 SCREWS RECOMMENDED)
5) CONNECT TEMPERATURE SENSOR TO TBX
CONTROLLER
IF POINTERS WERE PROVIDED SEPARATELY, DO NOT
INSTALL THEM YET
IF POINTERS ARE ALREADY INSTALLED, JUST GO ON
TO STEP (3) BELOW
½”NPT FITTING WITH NUT PROVIDED FOR MOUNTING
50’ CABLE PROVIDED WITH SENSOR ASSEMBLY
CLASS II SIGNAL CABLE - FOLLOW LOCAL CODES
OBSERVE POLARITY AS SPECIFIED
LOCATE SENSOR IN OPEN AIR
DO NOT LOCATE IN DIRECT SUNLIGHT OR NEAR
HEATING OR COOLING EQUIPMENT
!
!
!
!
!
!
!
!
4) MOUNT TEMPERATURE SENSOR ASSEMBLY
(THERMOMETERS ONLY)
M209B
Pg.3of12
TEMP. SENSOR
FROM TEMP. SENSOR
SHIELD
S+-
04-23-04 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

QUICK START GUIDE
6) CONNECT TBX CONTROLLER TO DIALS
(24VDC - 16AWG RECOMMENDED)
CONNECT DEDICATED 115VAC BRANCH CIRCUIT
TO TBX CONTROLLER
!
!
!
!
CONNECT SHIELD TO CONTROLLER ONLY
CONNECT MULTIPLE DIALS IN PARALLEL
IF YOUR THERMOMETER DIALS WERE PROVIDED
WITH POINTERS ALREADY INSTALLED, SKIP TO STEP
(12)
WAIT AT LEAST 60 SECONDS BEFORE PROCEEDING
TO STEP 9
7)
8) TURN ON 115VAC POWER
9) INSIDE TBX CONTROLLER, PRESS “HOME”
BUTTON ONCE
10) IF POINTER WAS PROVIDED SEPARATELY,
INSTALL POINTER ONTO DIAL POINTING TO
LOWEST READING ON DIAL (-20 F SHOWN)~
115VAC/60Hz/1A
L
N
G
POWER IN
115 VAC DEDICATED
BRANCH CIRCUIT
M209B
Pg.4of12
HOME
WAIT
AB
S
MOVEMENT
TO CIRCUIT BOARD
ON MOVEMENT
SHIELD
+-
04-23-04 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

HOME
M209B
Pg.5of12
QUICK START GUIDE
11) INSIDE TBX CONTROLLER, PRESS “HOME”
BUTTON ONE MORE TIME
12) THERMOMETER WILL AUTOMATICALLY RESET
ITSELF TO CORRECT TEMPERATURE
04-23-04 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

INTRODUCTION
The TBX Thermometer / Barometer System is comprised of a microprocessor
based controller and a step-motor driven movement that provide accurate,
completely automatic indication of Temperature or Barometric Pressure.
Completely automatic operation - No user intervention required
Maintenance free
Automatically resets after power failures to ensure correct readings
For indoor or outdoor use - Protected to Ip67
!
!
!
!
M209B
Pg.6of12
SPECIFICATIONS
Power Requirements
Accuracy
Inputs
Outputs
Communication
24VAC/50-60 Hz/1.67A (Plug-in Wall Transformer Provided)
+/- 1.5 F
Temperature Sensor
Thermometer / Barometer Control Signal
RS-232
~
!
!
!
!
!
!
!
!
!
!
3 Position Screw Terminal Connection
2 Terminals = Sensor Signal
1 Terminal = Shield Wire
Barometer Sensor
Factory installed directly onto PC Board
5 Position Screw Terminal Connection
2 Terminals = 24VDC
2 Terminals = RS-485 Communication
1 Terminal = Shield Wire
**Controls up to (2) Thermometers or Barometers total
Factory programming and setup (DB9 Connector)
RS-485
Auxiliary communication port (3 Position Screw Terminal)
04-23-04 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

TEMPERATURE
SENSOR INPUT
MOVEMENT CONTROL
SIGNALS
POWER INPUT
(24VAC PLUG-IN
WALL TRANSORMER
PROVIDED)
Terminal Compartment Layout
M209B
Pg.7of12
04-23-04 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

M209B
Pg.8of12
FEATURES
1)
POWER: Illuminates to Indicate Input Power is OK
HEART BEAT: Blinks to indicate processor is functioning properly
TEMP SENS: Indicates Temperature Sensor is connected
BARO SENS: Indicates Barometer Sensor is installed on PC Board
1 - 16: Indicate RS-485 Device Address of connected movements
(See Table 1 - Pg. 9)
2)
Press once to send movement to its home index position
Press again to resume normal operation
Typically used to send movement to “home” position before installing pointer
3)
Press once to send movement to its full-scale reading
Press again to resume normal operation
Typically used to verify that movement is operating normally
LED’s
“HOME” Button
“FULL SCALE” Button
!
!
!
!
!
!
!
!
!
!
!
OPERATION
The TBX Controller is setup and calibrated at the factory to provide years of
maintenance-free, accurate temperature / barometric pressure indication. After
installing a Thermometer or Barometer per the setup instructions provided, the unit
operates as follows:
TBX reads Temperature Sensor or Barometric Pressure Sensor
TBX converts reading to a known angular pointer position on display dial
TBX sends command signal (via RS-485) to movement to drive pointer to correct
position
TBX repeats this process continually to constantly update pointer position as
required
After power outage, TBX will command movement to reindex (go to “HOME”
position) and then bring pointer back to correct position to ensure accuracy of
display
!
!
!
!
!
04-23-04 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

M209B
Pg.9of12
DEVICE ADDRESSES
Any Thermometer / Barometer movement that is connected to the TBX
Controller will have a unique address such that the TBX Controller can send different
commands (via RS-485) to specific movements depending upon their address. In
this way, one TBX Controller can control a Thermometer and Barometer
simultaneously (or two Thermometers with different temperature scales, etc.). The
status LED’s inside the TBX indicate what addresses are being used by movements
that are connected to the controller. Not only does this indicate that a movement is
connected (helpul when troubleshooting) but it also tells what type of movement is
connected. Using the following table it is possible to determine what type of
movement is connected to the control based upon its address.
Table 1
Address Type of Movement
1 Customizable
2 Customizable
3 Customizable
4 Customizable
5 HMI Thermometer
6 HMI Thermometer
7 B28 Thermometer
8 B28 Thermometer
9 HMI Barometer
A HMI Barometer
BB28Barometer
CB28Barometer
D C1 Thermometer
0 C1 Thermometer
04-23-04 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

M209B
Pg.10 of 12
TROUBLESHOOTING
“MY THERMOMETER / BAROMETER IS NOT CORRECT”
!Pointer still moves, but readings shown are not correct
1) Send the Pointer to “HOME” position
Inside TBX Controller, press “HOME” button once
Look at dial: Pointer should point to lowest reading on dial and stop (ex. -20 F)
If Pointer is NOT pointing to lowest reading on dial, it must be adjusted manually
Remove pointer from movement shaft and follow instructions in “Quick Start
Guide” for proper setup of Thermometer / Barometer systems
If Pointer IS pointing to lowest reading on dial, see “Calibration Procedure” on
Page 11 to calibrate the thermometer
!
!
!
!
!
~
“MY THERMOMETER / BAROMETER DOESN’T MOVE”
1) Check AC Power Input
Inside TBX Controller, is POWER LED illuminated?
If not, have an electrician check circuit breakers or building electrical supply
2) Check Temperature Sensor (for Thermometer Systems only)
Inside TBX Controller, is Temperature Sensor connected?
If not, reconnect sensor and hit “HOME” button once to re-index the thermometer
WAIT 60 Seconds, then hit “HOME” button again to resume operation
Is Pointer showing correct temperature?
If not, contact Electric Time Company for service
3) Is movement(s) connected to TBX Controller?
Inside TBX Controller, are any address LED’s illuminated (numbers 1-16)?
If not, check all wiring connections to movement
If all wiring connections are OK, contact Electric Time Company for service
!
!
!
!
!
!
!
!
!
!
04-23-04 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

M209B
Pg. 11 of 12
TROUBLESHOOTING
CALIBRATION PROCEDURE
If the thermometer or barometer is operating, but does not indicate the correct reading,
the following calibration procedure can be used to set the thermometer/barometer to the
correct reading
CAUTION: The following calibration procedure requires opening the TBX Controller
while it is powered. Although the supply voltage to the controller is typically only
24VAC or 24VDC, this procedure should only be performed by a qualified technician
or electrician.
With the thermometer operating normally, remove the cover to the TBX Controller
Housing
At the top edge of the circuit board near the middle of the board is a vertical row of
2-pin headers (identified as JP4 on the circuit board) and labeled THERM, BARO,
CLEAR, & PARK
There is a small black jumper located in the PARK position
Move this jumper to the THERM or BARO position to enter calibration mode for
either a Thermometer or Barometer respectively
With the jumper in place, locate the adjustment potentiometer (identified as R39
on the circuit board) and labeled ADJUST
Using a small screw driver, slowly turn the ADJUST potentiometer
The pointer on the Thermometer / Barometer dial will move as the potentiometer
is turned
Turn the potentiometer until the pointer indicates the correct temperature or
barometeric pressure as required
When the pointer indicates the correct reading on the dial, remove the jumper
from the calibration position and return it to the PARK position for storage
!
!
!
!
!
!
!
!
!
04-23-04 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

SERVICE
For assistance in troubleshooting problems with your TBX Controller, or to request
service, contact the Electric Time Company Service Department at the address shown
below:
Electric Time Company, inc.
Service Department
45 West Street
Medfield, MA 02052 USA
Ph: (508) 359-4396
Fax: (508) 359-4482
Email: [email protected]
M209B
Pg. 12 of 12
REVISION HISTORY
12-11-03 Revision A - Manual for new TBX System
04-23-04 Revision B - Changed enclosure for easier wiring
- added “Time movements” to addresses 1-4
- Changed movement addresses.
04-23-04 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

1
1
2
2
A A
B B
TREATMENT
FINISH
APPROVALS
DRAWN
DATE
TITLE
SIZE
SHEET 1
SCALE: REV.
ENGINEER
medfield, macompany, inc
UNLESS OTHERWISE SPECIFIED:
ALL DIMENSIONS IN INCHES
DWG. NO.
TOLERACES ON DECIMAL DIMENSIONS:
.X `.031 .XX `.01 .XXX `.005
DO NOT SCALE DRAWING
MATERIAL WIRING DIAGRAM
AA-5661
CTRL-TBX
THA
THA
7-13-2004
NONE
NONE
NONE
NONE
M:\INVENTOR\DRAWINGS\A-5661.idw
ENCL-TBX
MOVEMENT WIRING
(4) WIRE + SHIELD
(16AWG RECOMMENDED)
(A) - WHITE
(B) - GREEN
(+) - RED
(-) - BLACK
TEMPERATURE SENSOR WIRING
(2) WIRE + SHIELD
(50' PROVIDED; 300' MAX)
(+) - RED
(-) - BLACK
24VAC 50/60-HZ 1.67A
(PLUG-IN TRANSFORMER
PROVIDED)
NOTES:
- TEMPERATURE SENSOR TO BE
MOUNTED IN OPEN AIR, OUT OF
DIRECT SUNLIGHT, AND AWAY
FROM HEATING AND COOLING
EQUIPMENT
- ADDITIONAL THERMOMETERS
OR BAROMETERS TO BE WIRED IN
PARALLEL
1/2" NPT

Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com
Table of contents
Other Electric Time Controllers manuals