Mon Jun 01, 2009
12:00:00 PM DST
97 West Street
Medfield, MA 02052
U.S.A. (508) 359-4396
www.electrictime.com
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

QUICK START GUIDE ..........................................................................
INTRODUCTION ...................................................................................
SPECIFICATIONS .................................................................................
TERMINAL COMPARTMENT LAYOUT.................................................
MOUNTING ...........................................................................................
BEFORE MAKING CONNECTIONS ! ...................................................
CONNECTING “MI CLOCKS”...............................................................
CONNECTING “MI-SS CLOCKS”.........................................................
CONNECTING “RP CLOCKS”..............................................................
CONNECTING “GPS”...........................................................................
CONNECTING “HR” Output ................................................................
CONNECTING “MULTI-DROP” & “AUX”.............................................
CONNECTING POWER.........................................................................
USER INTERFACE ...............................................................................
BASIC DISPLAYS .................................................................................
OPERATION ..........................................................................................
BASIC SETUP FUNCTIONS..................................................................
TECH MODE ..........................................................................................
TROUBLESHOOTING............................................................................
SERVICE ................................................................................................
DST CHANGE ........................................................................................
WIRING DIAGRAMS..............................................................................
M274
Pg. 2 of 20
TABLE OF CONTENTS
3
4
4
5
6
6
6
7
7
7
8
8
8
9
10
10
11
12
15
18
18
19
A-7960
A-7960-1
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

QUICK START GUIDE
1) DISCONNECT 115VAC POWER CIRCUIT BEFORE
MAKING ANY WIRING CONNECTIONS
2) INSTALL ALL CLOCKS WITH CLOCK HANDS
POINTING AT 12:00
3) INSTALL 99B-MI CLOCK CONTROLLER
(#10 SCREWS RECOMMENDED)
4) CONNECT 99B-MI CLOCK CONTROLLER TO
CLOCKS (24VAC - 16AWG RECOMMENDED)
!
4 OUTPUTS PROVIDED LABELED “MI CLOCK” 1-4
!
“HOME RUN” WIRING REQUIRED FROM EACH
CLOCK TO 99B-MI OUTPUTS “MI CLOCK” 1-4
!
SHIELDED CABLE RECOMMENDED
5) CONNECT DEDICATED 115VAC BRANCH CIRCUIT
TO 99B-MI CLOCK CONTROLLER
6) TURN ON 115VAC POWER
7) CLOCKS WILL AUTOMATICALLY RESET TO
CORRECT TIME
115VAC/60Hz/1A
L
N
G
POWER IN
115 VAC DEDICATED
BRANCH CIRCUIT
M274
Pg. 3 of 20
L1 L2 C
G
MI CLOCK 1
TO CIRCUIT BOARD
ON CLOCK
SHIELD
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

INTRODUCTION
The 99B-MI Clock Controller is a microprocessor based master clock that
provides completely automatic control of Electric Time minute impulse clocks.
!Provides “Minute Impulse” (MI) Control
(Clock hands index from one minute to the next)
!Automatically resets clocks after power failures (Resets at 6X speed)
!Automatically resets clocks for Daylight Saving Time (if required)
!Customizable Daylight Saving Time
!Precision Quartz Time Base
!Optional GPS interface for ultimate time keeping accuracy
!10 Year Battery Backup for time base
!For indoor or outdoor use - Protected to IP65
!ETL listed to UL 863
M274
Pg. 4 of 20
SPECIFICATIONS
Input Power 115VAC/50 or 60Hz/1A or 230VAC/50 or 60Hz/0.5A (Factory Preset)
Timebase Drift +/- 4 min / year (standard), NONE (GPS)
Clock Outputs 24VAC Minute Impulse
!
Controls up to (4) Minute Impulse (MI) Clocks
24VDC Reverse Polarity
!
Controls up to (20) Reverse Polarity (RP) Clocks
24VAC Sweep Second line (continuous power)
!
Controls up to (2) MI Clocks with Sweep Second Hands
**For multiple clock arrays, contact Electric Time to verify maximum
electrical loads on 99B-MI
Event Outputs 24VAC Hour Strike (configurable pulse output)
Communication RS-232 port, RS-485 port
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

9.95 [253 mm] 4.53 [115 mm]
7.83 [199 mm]
7.03 [179 mm]
7.78 [198 mm]
WIRING TERMINAL
COMPARTMENT
CLEAR HINGED
COVER
Ø0.21 [Ø5.2 mm]
M274
Pg. 5 of 20
DIMENSIONS IN INCHES [MILLIMETERS]
WARNING: DISCONNECT POWER BEFORE SERVICING OR CHANGING FUSE
USE COPPER CONDUCTORS ONLY CAUTION: REPLACE FUSES WITH SAME TYPE SHOWN
PGM L1 L2 C
G
MI CLOCK 3
115VAC/60Hz/1A
L
N
G
POWER IN
GPS
C
HRSS
RP CLOCKS
24VDC / 1A
+-
RS-232
AUX
GND
TX RX
12V
RS-485
MULTI - DROP
GND
BA
12V
L1 L2 C
G
MI CLOCK 4
L1 L2 C
G
MI CLOCK 1
L1 L2 C
G
MI CLOCK 2
24VAC / 60 Hz / 2A TOTAL FUSE
1A/250 VAC
FUSE
2.5A/120 VAC
POWER
FACTORY
PROGRAMMING PORT
OPTIONAL
GPS INTERFACE
RS-485
CONNECTION
REVERSE POLARITY
CLOCK OUTPUT
SWEEP SECOND
& HOUR STRIKE
OUTPUTS
ELECTRIC TIME
MI CLOCK
OUTPUTS
POWER INPUT
(230 VAC OPTIONAL)
RS-232
CONNECTION
24VAC TRANSFORMER
POWER INDICATOR
SECONDARY
FUSE PRIMARY
FUSE
Terminal Compartment Layout
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

M274
Pg. 6 of 20
MOUNTING
Mount the 99B-MI in an accessible location using suitable
hardware per installation (#10 Screws recommended)
BEFORE MAKING CONNECTIONS !
Shut off power to all circuits before making any electrical
connections. DO NOT connect 115VAC mains power to 99B-MI
until all other wiring connections have been made
All clocks should be installed / mounted with all clock hands
pointing at 12:00. Clocks will automatically reset to correct time
when power is applied to 99B-MI
For ease of installation, all 99B-MI Inputs & Outputs are shown
on the wiring label on the inside of the terminal compartment
cover. (See Pg. 5)
CONNECTING “MI CLOCKS”
(Minute Impulse - 24VAC)
For multiple clocks, “Home Run” wiring is required
between each clock and one of the “MI CLOCK” outputs
on 99B-MI
L1 L2 C
G
MI CLOCK 1
TO CIRCUIT BOARD
ON CLOCK
SHIELD
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

CONNECTING “MI-SS CLOCKS”
(Minute Impulse, Sweep Second - 24VAC)
For multiple clocks, “Home Run” wiring is required between each
clock and one of the “MI CLOCK” outputs on 99B-MI
Connect “SS” & “C” terminals to the “LINE” and
“NEUTRAL” terminals respectively of the smaller
circuit board on the clock
M274
Pg. 7 of 20
C
HRSS
LN
SMALLER CIRCUIT
BOARD
CONNECTING “RP CLOCKS”
(Reverse Polarity - 24VDC)
Multiple clocks to be wired in parallel
Ensure that polarity is the same for all clocks
(i.e. wires connect to same side of connector on all clocks)
TO CONNECTOR ON
CLOCK
RP CLOCKS
24VDC / 1A
+-
CONNECTING “GPS”
Connect GPS Receiver to “GPS” terminals, matching wire
colors to colors shown on wiring diagram on inside cover of
terminal compartment
TO GPS RECEIVER
GPS
L1 L2 C
G
MI CLOCK 1
TO CIRCUIT BOARD
ON CLOCK
SHIELD
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

M274
Pg. 8 of 20
CONNECTING “HR” OUTPUT
Connect “HR” & “C” terminals to LINE & NEUTRAL
terminals respectively of external device
(See Manual M274-C for explanation of “HR” Output
function)
TO EXTERNAL
DEVICE OR RELAY
C
HRSS
CONNECTING “MULTI-DROP” & “AUX”
For custom installations only. Contact Electric Time for information.
POWER CONNECTION
Connect , and terminals to 115 VACGround Neutral Line
dedicated branch circuit
115VAC DEDICATED
BRANCH CIRCUIT
115VAC/60Hz/1A
L
N
G
POWER IN
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

M274
Pg. 9 of 20
USER INTERFACE
1) LCD Display
2) ENTER
!
Hold for (5) seconds to access menus
!
Use to activate menus and make selections
3) CANCEL
!
Use to cancel active menu selections
!
Hold for (5) seconds to exit all menus
4) ArrowsUP / DOWN
!
Use to scroll through menus and menu selections
5) LED’s
!
L1 / L2: Indicate which MI output line is active
!
HR: Indicates status of HR output
!
GPS: Indicates status of GPS
>
OFF: GPS not connected
>
Flashing: GPS found but not locked
>
ON: GPS locked
!
ON: Blinks to indicate 99B-MI is on and processor is running
HOLD ENTER
KEY TO BEGIN
CANCEL
HR
I01DN
Mon Jun 01, 2009
12:00:00 PM DST
97 West Street
Medfield, MA 02052
U.S.A. (508) 359-4396
www.electrictime.com
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

M274
Pg. 10 of 20
“Running” Display
!
!
Displays current Date and Time
Displays “DST” during periods of the year when
Daylight Saving Time is being observed (will not
be displayed in locations not observing Daylight
Saving Time)
“Correcting Clock” Display
!
Appears when clock is resetting
!
Alternates with Running Screen every 6 seconds
!
Displays current location of clock hands
!
Note: If clock hands are fast by 2 hours or less,
hands will not move during reset mode
BASIC DISPLAYS
OPERATION
The 99B-MI Clock Controller is designed for fully automatic operation. However, should user
intervention be required, review the following instructions for proper operation of the 99B-MI.
Accessing Menus
!
Hold ENTER key for (5) seconds
Making Menu Selections
!
Use UP / DOWN arrows to scroll through menus
!
Press ENTER key once to activate menu choices
!
Use UP / DOWN arrows to scroll through menu choices
!
Press ENTER key to select menu choice
!
Hold CANCEL key for (5) seconds to exit menus and return to “Running” Screen
Mon Jun 01, 2009
12:00:00 PM DST
Correcting Clock
Hands At: 11:20
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

M274
Pg. 11 of 20
BASIC SETUP FUNCTIONS
“Set Time:”
!
Allows user to set time shown on LCD display
!
Displays “GPS” if GPS is being used
!
NOTE: User cannot set time when GPS is locked
(GPS always maintains correct time)
“Set Date:”
!
Allows user to set Date
“Enter Hand Pos:”
If clock hands are not indicating correct time, user must tell 99B-MI where
hands are pointing so controller can reset hands to correct position.
!
Enter position of clock hands
!
Clock hands will not move while this menu is displayed
!
This menu will not “time out” or shut off, so user has time to go outside
building to view clock if necessary
!
When done, hold “CANCEL” key for 5 seconds to exit menus and allow
99B-MI to reset clocks to correct time
“Chimes”
!
Allows user to configure Chimes and Hour Strike
outputs
!
See Manual M274-C (99BMI Chime System)
“Time Mode:”
!
12 Hr: Sets LCD display to standard 12 Hour clock
!
24 Hr: Sets LCD display to “Military Time” 24 Hr clock
Time Mode:
12 Hr
Set Time:
12:00:00 PM
Set Date:
2009-Jun-01
Enter Hand Pos:
11:20
Chimes:
Enabled
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

M274
Pg. 12 of 20
“Exit User Mode?”
!
: Does nothing, stays on “Exit User Mode?”NO
Menu
!
YES: Exits menus and returns to “Running
Screen”
!
Enter Tech Mode: Allows user to access special
technician menus
BASIC SETUP FUNCTIONS (continued)
Exit User Mode?
NO
TECH MODE
Press ENTER Key
To Read Log
“Event Log:”
!
Displays record of events, power ups, etc.
!
The (10) most recent events are displayed
!
Events are logged in the format: # MMDDYY HHMM EE,
where # is the number of the event (0-9), MMDDYY
HHMM is the date and time the event occurred, and EE
is the event code
!
Event Codes:
>
01: Power Up Sequence
>
02: GPS-Clock Synchronization
>
03: Brownout Sequence
“L1/L2 Drive Opt:”
!
For custom projects only, contact Electric Time Co
for details
!
Set to by default. Clocks will notMinute Impulse
operate properly if changed!!
L1/L2 Drive Opt:
Minute Impulse
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

M274
Pg. 13 of 20
“Daylight Saving Mode”
!
Table: 99B-MI will update time for Daylight Saving
time changes.
!
: Time changes will take place on set month,Rule
week and day (DST start adjusts local time
forward, DST End adjust local time backwards).
!
Disabled: 99B-MI will NOT update time for
Daylight Saving time changes.
Daylight Saving
Mode: Table
TECH MODE (Continued)
“Set DST Offset:”
!
Allows customization of the Daylight Saving time
offset. (Note: this only changes offset amount, not
forwards or backwards
Set DST Offset:
60 Minutes
United States UTC offsets:
>
AST -04:00 Atlantic Standard Time
>
EST -05:00 Eastern Standard Time
>
CST -06:00 Central Standard Time
>
MST -07:00 Mountain Standard Time
>
PST -08:00 Pacific Standard Time
>
AHST -10:00 Alaska-Hawaii Standard Time
Set UTC Offset:
-05:00
RP Hand Pos:
11:40
“Set UTC Offset:”
!
Allows user to set their local time offset from
Greenwich Mean Time
!
GPS NOTE: UTC offset must be set correctly for
GPS to maintain correct time
“RP Hand Pos:”
!
Allows user to correct ONLY the RP clock
movement hand position
!
NOTE: Only pertains to RP (reverse polarity)
Clock movements. Use “Set Hands” in user mode
for all other clock types
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

M274
Pg. 14 of 20
“Advance Hands?”
!
: Does nothing, stays on “Advance Hands?”NO
Menu
!
: Advances clock hands indefinitely untilYES
stopped manually
!
: Advances clock hands to 12:00 and stopsTo 12:00
Note: Pressing the Enter key again allows
the target time to be changed.
“Leave Tech Mode?”
!
: Does nothing, stays on “Leave Tech Mode?” MenuNO
!
: Exits menus and returns to “Running Screen”Exit All
!
: Enters User Mode menusEnter User Mode
Advance Hands?
NO
Leave Tech Mode?
NO
TECH MODE (Continued)
“DST End” (Only visible when RULE is selected)
!
Week: Sets the time change to end on the 1st,
2nd, 3rd, 4th or Last week of the month
!
: Sets the day the time changes. All timeDay
changes take place at 2am.
!
Month: Sets the month the time change will end
DST End:
Last Sun OCT
“Fiber Optic Use:”
!
For custom projects only
!
Contact Electric Time for information
Fiber Optic Use:
Disabled
“DST Start” (Only visible when RULE is selected)
!
Week: Sets the time change to start on the 1st,
2nd, 3rd, 4th or Last week of the month
!
: Sets the day the time changes. All timeDay
changes take place at 2am.
!
Month: Sets the month the time change will start
DST Start:
Last Sun APR
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

M274
Pg. 15 of 20
TROUBLESHOOTING
“MY CLOCKS ARE NOT ON TIME”
!
Clock hands are still operating, but are not indicating correct time
1) Is the time shown on the 99B-MI correct?
YES: Goto Step 3
NO: Goto Step 2
2) Correct the time shown on the 99B-MI
!Hold the “ENTER” key for 5 seconds to access menus
!Use Down arrow to scroll through menus until “Set Time:” menu is visible
!Hit “ENTER” key once to access “Set Time:” menu
!Use Up or Down arrows to adjust Hours
!Hit “ENTER” key to move to minutes
!Use Up or Down arrows to adjust Minutes
!Hit “ENTER” key to move to seconds
!Hit “ENTER” key to “00” seconds and accept changes that were just made
!Hold “CANCEL” key for 5 seconds to exit menus and allow clocks to self-correct
3) Tell 99B-MI where clock hands are to allow it to correct the clockactually pointing
You will enter the time the clock hands are reading into the controller. The controller
will then move the hands to the correct time.
!Hold the “ENTER” key for 5 seconds to access User Mode
!Use Down arrow to scroll through menus until “Enter Hand Pos:” menu is visible
!When “Enter Hand Pos:” menu is being displayed, clock hands will NOT move
!STOP HERE AND READ THE TIME ON THE CLOCK
!Hit “ENTER” key once to access “Enter Hand Pos:” menu
!Use Up or Down arrows to set Hours to whatever hour clock hands indicate
!Hit “ENTER” key to move to minutes
!Use Up or Down arrows to set Minutes to whatever minute clock hands indicate
!Hit “ENTER” key to accept changes to hand position
!Hold “CANCEL” key for 5 seconds to exit menus and allow clocks to self-correct
!The display will alternate between “Correcting Clock Hands at:” and the actual
time and date information
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

M274
Pg. 16 of 20
TROUBLESHOOTING
Under certain conditions, when the 99B-MI is automatically correcting the clock hands
(i.e. “Reset Mode”), the hands may not move for up to 2 hours. This is NORMAL. To
determine if there is a actually a problem with your 99B-MI or your clocks, see below.
CAUTION: ONLY A QUALIFIED ELECTRICIAN SHOULD PERFORM ANY
TROUBLESHOOTING RELATED TO ELECTRICAL WIRING
1) Is the 99BMI live?
!If the LCD Display is working and the green “ON” LED is blinking, the 99BMI is live
YES: Goto Step 2
NO: Check 115VAC input power and both fuses in wiring compartment
2) Is the green LED marked “ON” in the 99BMI Front Panel blinking?
YES: Goto Step 3
NO: Contact Electric Time Company Service Department
3) Is the 99B-MI providing power to the clocks?
!Open the wiring compartment cover (unscrew the two hold-down screws)
!Is the 2.5A secondary fuse blown?
YES: Replace fuse. See “My Clocks are not on time” Pg. 15 to reset clocks as
required
NO: Goto Step 5
“MY CLOCKS ARE NOT MOVING”
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

M274
Pg. 17 of 20
TROUBLESHOOTING
4) Is the 99B-MI in “Reset Mode”?
!When in “Reset Mode” the 99B-MI display will alternate every few seconds
between the “Running” display (See Pg. 10) and the “Correcting Clock” display
(See Pg. 10)
Is the 99B-MI alternating between the “Running” and “Correcting Clock” displays?
YES: Goto Step 6
NO: Goto Step 7
5) Does the 99B-MI know where the clock hands are?
!The “Correcting Clock” display will show where the 99B-MI thinks that the clock
hands are currently located (example: “Hands At: 12:00”)
Does the “Correcting Clock, Hands At:” display match the current hand position?
YES: Hands will begin moving at correct time within the next 2 hours
NO: See “My clocks are not on time” Pg. 15, Step 3
6) Check wiring
!Verify all wiring is OK from 99B-MI to each clock Note: this is one of the most
common errors when installing the clock controller, be sure to check the wiring at
the clock movement and clock control.
Is wiring OK?
YES: Possible failure of motor or circuit board on clock (CMI PC Board)
Contact Electric Time Company Service Department
NO: Fix wiring, repeat troubleshooting as required
“MY CLOCKS ARE NOT MOVING”
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

SERVICE
For assistance in troubleshooting problems with your 99B-MI Clock Controller, or to
request service, contact the Electric Time Company Service Department at the
address shown below:
Electric Time Company, inc.
Service Department
97 West Street
Medfield, MA 02052 USA
Ph: (508) 359-4396
Fax: (508) 359-4482
Email: [email protected]
M274
Pg. 18 of 20
DST Change (North America only)
Beginning in the Spring of 2007, the Energy Policy Act of 2005 changed the starting
and ending dates of Daylight Saving Time for the United States. As of January 1st
2006 all controls shipped from Electric Time Co. have the updated Daylight Saving
Time for 2007 and beyond.
In the event the US Government reverts to the 2005 Schedule or a different DST
schedule the 99B-MI clock controller is capable of being reprogrammed with a new
DST rule through the user interface. For more details on changing the DST rule
please see page 13.
REVISION HISTORY
03-21-03 First Release
07-25-05 Revised
09-14-06 DST table/rule added
06-01-09 “L1/L2 Opt” & “RP Hand Position” added
07-01-15 Wiring Diagram A-7960-1 replaced with A-14425
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com

MI OUTPUTS
(24VAC / 2A MAX)
115VAC / 60Hz
CLOCK
CONTROLLER
(1A MAX)
L1 (BLK)
L2 (RED)
*G (SHIELD)
C(WHT)
99B-MI
"CMI" BOARD
(1 PER CLOCK)
"CMI" BOARD
(1 PER CLOCK)
TO
ADDITIONAL
CLOCKS
LINE (BLK)
NEUTRAL (WHT)
GROUND (G)
*Shield Connects
ONLY at 99B-MI
CLASS II (24VAC)
16 AWG WIRE
RECOMMENDED
SYSTEM CLOCKS : "MI" OPERATION
LOCAL
DISCONNECT
{BY OTHERS}
CLOCK ILLUMINATION
115VAC / 60Hz
LINE (BLK)
NEUTRAL (WHT)
GROUND (G)
PHOTOCELL
OR
LIGHTING CONTROL
{BY OTHERS}
L1 (BLK)
L2 (RED)
*G (SHIELD)
C(WHT)
L1 (BLK)
L2 (RED)
*G (SHIELD)
C(WHT)
CONTROL WIRING
ILLUMINATION WIRING
(IF APPLICABLE)
"HOME RUNS" REQUIRED
ALL "MI" CLOCKS
CONTROL SPECIFICATIONS
1) CONTROLS UP TO (4) "MI" CLOCKS
2) MAX CONTROL WIRE RUN 350'
3) "HOME RUNS" REQUIRED FROM EACH CLOCK
4) DEDICATED 115VAC BRANCH CIRCUIT MUST
BE PROVIDED FOR 99B-MI CONTROLLER
5) CONNNECTIONS FOR 1/2" CONDUIT PROVIDED
06-01-2009 Electric Time Company, inc. Medfield, MA 02052 USA
Ph: (508) 359-4396 Fax: (508) 359-4482
www.electrictime.com
Table of contents
Other Electric Time Controllers manuals