19ENGLISH
5. Presenceofreextinguisher.If
anyhotworkistobeconductedon
the refrigeration equipment or any
associatedparts,appropriatere
extinguishingequipmentshallbe
availabletohand.Haveadrypowder
orCO2reextinguisheradjacentto
the charging area.
6. No ignition sources. No person carrying
out work in relation to a refrigeration
system which involves exposing
any pipe work that contains or has
containedammablerefrigerantshall
use any sources of ignition in such a
manner that it may lead to the risk of
reorexplosion.Allpossibleignition
sources, including cigarette smoking,
shouldbekeptsucientlyfaraway
from the site of installation, repairing,
removing and disposal, during which
ammablerefrigerantcanpossibly
bereleasedtothesurrounding
space. Prior to work taking place, the
areaaroundtheequipmentistobe
surveyed to make sure that there are
noammablehazardsorignitionrisks.
“NoSmoking”signsshallbedisplayed.
7. Ventilated area. Ensure that the area
is in the open or that it is adequately
ventilatedbeforebreakinginto
the system or conducting any hot
work. A degree of ventilation shall
continue during the period that the
work is carried out. The ventilation
should safely disperse any released
refrigerantandpreferablyexpelit
externally into the atmosphere.
8. Checks to the refrigeration equipment.
Where electrical components are
beingchanged,theyshallbet
for the purpose and to the correct
specication.Atalltimesthe
manufacturer’s maintenance and
serviceguidelinesshallbefollowed.
Ifindoubtconsultthemanufacturer’s
technical department for assistance.
Thefollowingchecksshallbeapplied
toinstallationsusingammable
refrigerants:
– The charge size is in accordance
with the room size within which
the refrigerant containing parts
are installed;
– The ventilation machinery and
outlets are operating adequately
andarenotobstructed;
– If an indirect refrigerating circuit is
beingused,thesecondarycircuit
shallbecheckedforthepresence
of refrigerant;
– Marking to the equipment continues
tobevisibleandlegible.Markings
andsignsthatareillegibleshallbe
corrected;
– Refrigeration pipe or components
are installed in a position where
theyareunlikelytobeexposedto
anysubstancewhichmaycorrode
refrigerant containing components,
unless the components are
constructed of materials which
areinherentlyresistanttobeing
corrodedoraresuitablyprotected
againstbeingsocorroded.
9. Checks to electrical devices. Repair
and maintenance to electrical
components shall include initial safety
checks and component inspection
procedures. If a fault exists that could
compromise safety, then no electrical
supplyshallbeconnectedtothecircuit
until it is satisfactorily dealt with. If the
faultcannotbecorrectedimmediately
butitisnecessarytocontinue
operation, an adequate temporary
solutionshallbeused.Thisshallbe
reported to the owner of the equipment
so all parties are advised.
Initialsafetychecksshallinclude:
• Thatcapacitorsaredischarged:this
shallbedoneinasafemannertoavoid
possibilityofsparking;
• That there no live electrical
components and wiring are exposed
while charging, recovering or purging
the system;
• That there is continuity of earth
bonding.
Repairs to sealed components
1. During repairs to sealed components,
allelectricalsuppliesshallbe
disconnected from the equipment
beingworkeduponpriortoanyremoval
ofsealedcovers,etc.Ifitisabsolutely
necessary to have an electrical supply
to equipment during servicing, then
a permanently operating form of leak
detectionshallbelocatedatthemost
critical point to warn of a potentially
hazardous situation.