6. Fault diagnosis/ What to do if ...?
6.1 Alarmmanagement(Faultcodes)
6.2 Demo Mode input electronic Avantgarde
6.2.1 Activating/deactivating Version a
Disconnect appliance approx. 10 sec from the supply mains. After the renewed connection „time of
day“ is lit, the display indicates „12.00“ . Now actuate the „selection“ key, afterwards activate the
demo mode by pressing together with the „selection“ and „minus“ key simultaneously within 2 sec.
For deactivating the demo mode please proceed in the same order.
The active demo Mode is confirmed by the time symbol in the display. When activating the Demo
Mode, please make a mental note of the positions of the „Selection“ and „Minus“ keys as these
have to be pressed once more in order to deactivate the Demo Mode but it is possible that these
arte not visible, depending on the date of manufacture and software version.
Display Description of fault Fault repair
F0 Internal error replace power electronics
F1 door cannot be locked Test door locking system
F2 door cannot be unlocked Test door locking system and unlocking thermostat
f11
F3 software error Execute network reset by disconnecting the
appliance from the electricity supply and restarting
F94 Temperature sensor alarm - resulting in F4 Test temperature sensor, replace if necessary
F4 Temperature sensor without contact or short circuit Test temperature sensor, replace if necessary
F5 Clotted heating element relay contacts on the
power electronics Replace power electronics
F95 Temperature alarm at power electronics - resulting
in F6 Test built-in situation of the ventilation channel and
the function of the cooling fan
F96 Temperature alarm at power electronics - resulting
in F6 Test built-in situation of the ventilation channel and
the function of the cooling fan
F6 Power electronics temperature too high Test built-in situation of the ventilation channel and
the function of the cooling fan
F7 Faulty electrical connection (only in appliances
with Prisma power electronics) Correctly connect the appliance and re-start
F8 No connection between power electronics and
input electronics Check connection line - replace electronic systems if
necessary
F9 Micro processor resets itself independently (=
Reset) Execute network reset by disconnecting the
appliance from the electricity supply and restarting
F10 Triac on power electronics defect Activate Main Button, select an operation modus
with hot air, wait for cooling ventilation start, replace
power electronics again in the event of an error report
following approximately 20 seconds
F11 Meat skewer sensor without contact or short-
circuited Check meat thermometer, also check bushing and
wiring if necessary; if all this OK replace power
electronics
F91 Temperature sensor alarm for steam generator -
resulting in F12 Test temperature sensor, replace if necessary
F12 Temperature sensor of steam generator without
contact or short-circuited Test temperature sensor, replace if necessary
F13 Internal electronics error Replace power electronics
F14 software error Replace input electronics
F15 Internal electronics error Replace input electronics
F16 Combined alarm Pyrolytic cleaning/cooking zone Replace input electronics
Alarmmanagement Powerboards Prisma, OVC1000 und OVC2000