Technical Specification
Safety and environmental conditions
CE marking
LV directive 2006/95/EC
RoHS directive 2011/65/EU
WEEE directive 2012/19/EU
Standard EN-IEC 61439-2:2011
EN-IEC 60269-3:2013
This product is designed to be safe under the following
conditions:
Specification
Environmental conditions
Operating temperature:
Relative humidity:
Protection degree:
Installation class:
Pollution degree:
-5°C - +55°C
5% - 85%, non condensing
IP23
1 (protective earth)
2
Application conditions
Umax:
Frequency:
Imax:
Imax to armature:
Fuse:
Strain relief:
Maximum wire cross section
and torque:
Diameter ø
Height
230/400V
50Hz
50A (mantle terminals)
6A
5L5001: DII (E27), max 6A
5L5301: D01 (E14), max 6A
Yes, maximum two ground cables
18mm and 1 light pole cord
Terminal 1, 2, 3, 4, 5: 2x 10mm2
or 3x 6mm2, 2-4Nm
Terminal 5, 6, 7, 8: 4mm2, 1-2Nm
74mm
265mm
Storage
Temperature:
Relative humidity:
-20°C - +70°C
5% - 85%, non condensing
Approval KEMA-keur
Specification per type
5L5001 5L5001-6A 5L5103
Fuse included 6A 6A
Neutral
Disconnector Yes
Weight 450gr 520gr 540gr
Please be aware, product liability, fulfilment to requirements and
warranty are all expired when modifications on the product are made.
ELEQ reserves the right to carry out modifications on its products, in
order to improve them, without prior notice.
Safety instruction
All activities for installation, commissioning and maintenance of
this connection box must be performed by qualified personnel
that has the knowledge of applicable safety precautions. This
guide assumes that the reader of this document has sufficient
electro-technical knowledge to understand the content of this
document.
General
The LS-74 is a connection box for public lighting and intended
to be used in lighting poles. The connection box should be
mounted in a weather protected and dry location. In the
connection box the incoming (ground) cable can be connected.
If desired, looped circuits wiring to the next lighting pole is
possible. The cable of the armature should be connected on
the outgoing terminals.
Fuses protect the installation against overload and short-
circuiting.
Explanation of symbols
This product is designed according to the
EN-IEC 61439-2:2011 standards and meets the
requirements of the Low Voltage Directive 2006/95/EC.
Read the installation guide before mounting the
product. Unprofessional work activities on electrical
installations may result in a threat of danger to the life
and health of human beings and livestock!
RoHS Directive 2011/65/EU
ELEQ states that it uses qualified components in its
products only from manufacturers which meet the
requirements of the European Directive for the
"Restriction of use of certain Hazardous Substances
WEEE Directive 2012/19/EU
This equipment should not be disposed as unsorted
municipal waste. Contact a qualified recycler for
disposal.
LS-74 Connection Box for
Public Lighting
Installation Guide
LS-74 5L5001
5L5001-6A
5L5103
Read this installation guide before installing the product
5L5103
83715 / EN1512
Technical Specification
Safety and environmental conditions
CE marking
LV directive 2006/95/EC
RoHS directive 2011/65/EU
WEEE directive 2012/19/EU
Standard
EN-IEC 61439-2:2011
EN-IEC 60269-3:2013
This product is designed to be safe under the following
conditions:
Specification
Environmental conditions
Operating temperature:
Relative humidity:
Protection degree:
Installation class:
Pollution degree:
-5°C - +55°C
5% - 85%, non condensing
IP23
1 (protective earth)
2
Application conditions
Umax:
Frequency:
Imax:
Imax to armature:
Fuse:
Strain relief:
Maximum wire cross section
and torque:
Diameter ø
Height
230/400V
50Hz
50A (mantle terminals)
6A
5L5001: DII (E27), max 6A
5L5301: D01 (E14), max 6A
Yes, maximum two ground cables
18mm and 1 light pole cord
Terminal 1, 2, 3, 4, 5: 2x 10mm2
or 3x 6mm2, 2-4Nm
Terminal 5, 6, 7, 8: 4mm2, 1-2Nm
74mm
265mm
Storage
Temperature:
Relative humidity:
-20°C - +70°C
5% - 85%, non condensing
Approval
KEMA-keur
Specification per type
5L5001
5L5001-6A
5L5103
Fuse included
6A
6A
Neutral
Disconnector
Yes
Weight
450gr
520gr
540gr
Please be aware, product liability, fulfilment to requirements and
warranty are all expired when modifications on the product are made.
ELEQ reserves the right to carry out modifications on its products, in
order to improve them, without prior notice.
Safety instruction
All activities for installation, commissioning and maintenance of
this connection box must be performed by qualified personnel
that has the knowledge of applicable safety precautions. This
guide assumes that the reader of this document has sufficient
electro-technical knowledge to understand the content of this
document.
General
The LS-74 is a connection box for public lighting and intended
to be used in lighting poles. The connection box should be
mounted in a weather protected and dry location. In the
connection box the incoming (ground) cable can be connected.
If desired, looped circuits wiring to the next lighting pole is
possible. The cable of the armature should be connected on
the outgoing terminals.
Fuses protect the installation against overload and short-
circuiting.
Explanation of symbols
This product is designed according to the
EN-IEC 61439-2:2011 standards and meets the
requirements of the Low Voltage Directive 2006/95/EC.
Read the installation guide before mounting the
product. Unprofessional work activities on electrical
installations may result in a threat of danger to the life
and health of human beings and livestock!
RoHS Directive 2011/65/EU
ELEQ states that it uses qualified components in its
products only from manufacturers which meet the
requirements of the European Directive for the
"Restriction of use of certain Hazardous Substances
WEEE Directive 2012/19/EU
This equipment should not be disposed as unsorted
municipal waste. Contact a qualified recycler for
disposal.
LS-74 Connection Box for
Public Lighting
Installation Guide
LS-74 5L5001
5L5001-6A
5L5103
Read this installation guide before installing the product
5L5103
83715 / EN1512
Technical Specification
Safety and environmental conditions
CE marking
LV directive 2006/95/EC
RoHS directive 2011/65/EU
WEEE directive 2012/19/EU
Standard
EN-IEC 61439-2:2011
EN-IEC 60269-3:2013
This product is designed to be safe under the following
conditions:
Specification
Environmental conditions
Operating temperature:
Relative humidity:
Protection degree:
Installation class:
Pollution degree:
-5°C - +55°C
5% - 85%, non condensing
IP23
1 (protective earth)
2
Application conditions
Umax:
Frequency:
Imax:
Imax to armature:
Fuse:
Strain relief:
Maximum wire cross section
and torque:
Diameter ø
Height
230/400V
50Hz
50A (mantle terminals)
6A
5L5001: DII (E27), max 6A
5L5301: D01 (E14), max 6A
Yes, maximum two ground cables
18mm and 1 light pole cord
Terminal 1, 2, 3, 4, 5: 2x 10mm2
or 3x 6mm2, 2-4Nm
Terminal 5, 6, 7, 8: 4mm2, 1-2Nm
74mm
265mm
Storage
Temperature:
Relative humidity:
-20°C - +70°C
5% - 85%, non condensing
Approval
KEMA-keur
Specification per type
5L5001
5L5001-6A
5L5103
Fuse included
6A
6A
Neutral
Disconnector
Yes
Weight
450gr
520gr
540gr
Please be aware, product liability, fulfilment to requirements and
warranty are all expired when modifications on the product are made.
ELEQ reserves the right to carry out modifications on its products, in
order to improve them, without prior notice.
Safety instruction
All activities for installation, commissioning and maintenance of
this connection box must be performed by qualified personnel
that has the knowledge of applicable safety precautions. This
guide assumes that the reader of this document has sufficient
electro-technical knowledge to understand the content of this
document.
General
The LS-74 is a connection box for public lighting and intended
to be used in lighting poles. The connection box should be
mounted in a weather protected and dry location. In the
connection box the incoming (ground) cable can be connected.
If desired, looped circuits wiring to the next lighting pole is
possible. The cable of the armature should be connected on
the outgoing terminals.
Fuses protect the installation against overload and short-
circuiting.
Explanation of symbols
This product is designed according to the
EN-IEC 61439-2:2011 standards and meets the
requirements of the Low Voltage Directive 2006/95/EC.
Read the installation guide before mounting the
product. Unprofessional work activities on electrical
installations may result in a threat of danger to the life
and health of human beings and livestock!
RoHS Directive 2011/65/EU
ELEQ states that it uses qualified components in its
products only from manufacturers which meet the
requirements of the European Directive for the
"Restriction of use of certain Hazardous Substances
WEEE Directive 2012/19/EU
This equipment should not be disposed as unsorted
municipal waste. Contact a qualified recycler for
disposal.
LS-74 Connection Box for
Public Lighting
Installation Guide
LS-74 5L5001
5L5001-6A
5L5103
Read this installation guide before installing the product
5L5103
83715 / EN1603
ELEQ b.v.
Tukseweg 130, 8331 LH Steenwijk, The Netherlands
+31 (0) 521 533 333 [email protected] www.eleq.com
ELEQ b.v.
Tukseweg 130, 8331 LH Steenwijk, The Netherlands
+31 (0) 521 533 333 [email protected] www.eleq.com
Always avoid working on live parts of an installation.
Functional Description
The terminal boxes of the LS-74 series all are intended to be
fitted with one DII or D01 fuse. Het fuse capacity is limited to
max 6A.
Assembly
1. Ensure a safe working area during assembly, maintenance
and inspection of the connection box. Disconnect the power
of the main circuit and make sure it cannot be enabled
unintentionally.
2. Remove the transparent cover, mounted fuse and the
intermediate cover.
3. Mount the connection box with the upper and lower
connection in the lighting pole.
4. Connect the incoming and (if present) outgoing ground
cable to terminals 1 through 5.
5. Mount the outgoing cables to the armature.
6. Tightly mount strain relief block.
7. Check if the connections are mounted properly and firmly.
8. Install the fuse(s). Fuse type: DII (E27) for 5L5001 or D01
(E14) for 5L5301. Max 6A.
9. Mount the transparent cover and screw tightly.
Incoming Outgoing
1 = PE - Protective earth 6 = Neutral
2 = Neutral 7 = fused phase L3
3 = phase L1 8 = PE - Protective earth
4 = phase L2
5 = phase L3
If required, incoming terminals 1 through 5 can be looped to the
next lighting pole.
Wiring Diagram
Maintenance and inspection
The connection box should be situated on a dry and clean
location.
The connection box should be mounted firmly.
The connections should be mounted firmly.
Attention
Always avoid working on live parts of an installation.
Disassembly instruction
1. Disconnect the power of the main circuit and make sure it
can not be enabled unintentionally.
2. Unmount the transparent cover.
3. Remove the fuses.
4. Remove the strain relief block.
5. Disconnect the ground cables.
6. Disconnect the connection box from the lighting pole.
Recycling
When the product has reached ‘end of life’, it must be recycled.
Do not dispose this product as unsorted municipal waste.
Contact a qualified recycler for disposal.
5L5001
5L5103
Always avoid working on live parts of an installation.
Functional Description
The terminal boxes of the LS-74 series all are intended to be
fitted with one DII or D01 fuse. Het fuse capacity is limited to
max 6A.
Assembly
1. Ensure a safe working area during assembly, maintenance
and inspection of the connection box. Disconnect the power
of the main circuit and make sure it cannot be enabled
unintentionally.
2. Remove the transparent cover, mounted fuse and the
intermediate cover.
3. Mount the connection box with the upper and lower
connection in the lighting pole.
4. Connect the incoming and (if present) outgoing ground
cable to terminals 1 through 5.
5. Mount the outgoing cables to the armature.
6. Tightly mount strain relief block.
7. Check if the connections are mounted properly and firmly.
8. Install the fuse(s). Fuse type: DII (E27) for 5L5001 or D01
(E14) for 5L5301. Max 6A.
9. Mount the transparent cover and screw tightly.
Incoming Outgoing
1 = PE - Protective earth 6 = Neutral
2 = Neutral 7 = fused phase L3
3 = phase L1 8 = PE - Protective earth
4 = phase L2
5 = phase L3
If required, incoming terminals 1 through 5 can be looped to the
next lighting pole.
Wiring Diagram
Maintenance and inspection
The connection box should be situated on a dry and clean
location.
The connection box should be mounted firmly.
The connections should be mounted firmly.
Attention
Always avoid working on live parts of an installation.
Disassembly instruction
1. Disconnect the power of the main circuit and make sure it
can not be enabled unintentionally.
2. Unmount the transparent cover.
3. Remove the fuses.
4. Remove the strain relief block.
5. Disconnect the ground cables.
6. Disconnect the connection box from the lighting pole.
Recycling
When the product has reached ‘end of life’, it must be recycled.
Do not dispose this product as unsorted municipal waste.
Contact a qualified recycler for disposal.
5L5001 5L5103
Always avoid working on live parts of an installation.
Functional Description
The terminal boxes of the LS-74 series all are intended to be
fitted with one DII or D01 fuse. Het fuse capacity is limited to
max 6A.
Assembly
1. Ensure a safe working area during assembly, maintenance
and inspection of the connection box. Disconnect the power
of the main circuit and make sure it cannot be enabled
unintentionally.
2. Remove the transparent cover, mounted fuse and the
intermediate cover.
3. Mount the connection box with the upper and lower
connection in the lighting pole.
4. Connect the incoming and (if present) outgoing ground
cable to terminals 1 through 5.
5. Mount the outgoing cables to the armature.
6. Tightly mount strain relief block.
7. Check if the connections are mounted properly and firmly.
8. Install the fuse(s). Fuse type: DII (E27) for 5L5001 or D01
(E14) for 5L5301. Max 6A.
9. Mount the transparent cover and screw tightly.
Incoming Outgoing
1 = PE - Protective earth 6 = Neutral
2 = Neutral 7 = fused phase L3
3 = phase L1 8 = PE - Protective earth
4 = phase L2
5 = phase L3
If required, incoming terminals 1 through 5 can be looped to the
next lighting pole.
Wiring Diagram
Maintenance and inspection
The connection box should be situated on a dry and clean
location.
The connection box should be mounted firmly.
The connections should be mounted firmly.
Attention
Always avoid working on live parts of an installation.
Disassembly instruction
1. Disconnect the power of the main circuit and make sure it
can not be enabled unintentionally.
2. Unmount the transparent cover.
3. Remove the fuses.
4. Remove the strain relief block.
5. Disconnect the ground cables.
6. Disconnect the connection box from the lighting pole.
Recycling
When the product has reached ‘end of life’, it must be recycled.
Do not dispose this product as unsorted municipal waste.
Contact a qualified recycler for disposal.
5L5001
5L5103

Popular Touch Terminal manuals by other brands

Chase Verifone VX Quick reference guide

Chase

Chase Verifone VX Quick reference guide

Motorola DCT1800 installation manual

Motorola

Motorola DCT1800 installation manual

ANZ Mobile PLUS operating guide

ANZ

ANZ Mobile PLUS operating guide

NCR RealPOS 40 user guide

NCR

NCR RealPOS 40 user guide

Denso BHT-1261QWB-CE Operator's guide

Denso

Denso BHT-1261QWB-CE Operator's guide

Carel pGDx quick start guide

Carel

Carel pGDx quick start guide

Denso BHT-604Q user manual

Denso

Denso BHT-604Q user manual

McCue CartStop FlexCore Post 3 installation instructions

McCue

McCue CartStop FlexCore Post 3 installation instructions

Wincor Nixdorf BEETLE /?-II technical information

Wincor Nixdorf

Wincor Nixdorf BEETLE /?-II technical information

bankSA EFTPOS 1i user guide

bankSA

bankSA EFTPOS 1i user guide

Carel PAD user manual

Carel

Carel PAD user manual

CEP HT63 E user manual

CEP

CEP HT63 E user manual

Furuno VHF DSC Terminal DSC-8V/8VP Operator's manual

Furuno

Furuno VHF DSC Terminal DSC-8V/8VP Operator's manual

dejavoo C5 user manual

dejavoo

dejavoo C5 user manual

Rockwell Automation SMC-Flex user manual

Rockwell Automation

Rockwell Automation SMC-Flex user manual

MINTRONIX MP5000i series user guide

MINTRONIX

MINTRONIX MP5000i series user guide

POSIFLEX RT-2015E user manual

POSIFLEX

POSIFLEX RT-2015E user manual

Emerson FB3000 Field installation guide

Emerson

Emerson FB3000 Field installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.