Elesa DD52R-E-RF User manual

Wireless spindle
positioning system

All rights reserved in accordance with the law. Always mention the source when reproducing our drawings and photos.
2
Efficient Machine Set-Up
The system allows to save time during the format
alignment process.
•
Once the set-up profile has been called up by PLC,
UC-RF control unit transmits the target position to
each DD52R-E-RF position indicator.
•
The current / target position is displayed on LCD
display of DD52R-E-RF indicator.
•
The operator manually sets the position of the
spindles following the arrow displayed on LCD display
(clockwise/anti-clockwise rotation).
•
Once all the spindles are correctly set, UC-RF control
unit communicates to PLC of the machine that the
set-up has been completed.
The wireless system, consisting of UC-RF control unit and up to 36 electronic position indicators DD52R-E-RF,
is designed for an efficient manual spindle positioning.
DD52R-E-RF position indicators (Elesa Patent) are networked to UC-RF control unit via radio frequency (RF),
so that connecting cables are not required for an easy and quick installation.
Current and target positions are transmitted via RF, from and to the control unit, facilitating machine set-up.
Easy installation
Up to 36 position indicators can be networked
(via radio frequency) to the control unit.
No cables required to connect the position indicators to
the control unit.
Safety
The system prevents the machine from starting up until
the machine set-up is completed, avoiding production
issues.
Wireless spindle
positioning system
Target positions
Current positions
Up to 36
PLC

All rights reserved in accordance with the law. Always mention the source when reproducing our drawings and photos.
3

Models all rights reserved in accordance with the law. Always mention the source when reproducing our drawings and photos.
4
DD52R-E-RF
Electronic position indicators
Data transmission by radio frequency
BASE AND CASE
High-resistance polyamide based (PA) technopolymer.
Black base.
Case in the following colours:
- C2: RAL 2004 orange, glossy finish.
- C3: RAL 7035 grey, glossy finish.
Available on request in RAL 7021 grey-black colour (C1).
Cover with perfectly sealed gasket and AISI 304 stainless steel UNI 6955
type self-tapping screws with six-lobe socket TORX®T06 (registered
trademark by TEXTRON INC.).
The ultrasonic welding between the base and the case prevents separation
and avoids dust and liquid penetration.
BOSS
AISI 304 stainless steel with Ø 20 mm H7 reamed hole, fitting to shaft
by means of AISI 304 stainless steel grub screw, hexagon socket and
cup end UNI 5929-85, included in the supply.
WINDOW
Transparent polyamide based (PA-T) technopolymer, moulded over
the case and with a perfect seal. Resistant to solvents, oils, greases
and other chemical agents (avoid contact with alcohol during cleaning
operations).
DISPLAY
- 6-digit LCD of 12,0 mm height and special characters.
The visualization parameters can be set and modified by the operator
by means of appropriate keys:
- values displayed in mm, inches or degrees
- display of mode for use (absolute or incremental mode)
- reading orientation (right or reverse).
KEYBOARD
Polyester membrane. Resistant to solvents, alcohol, acids, alkalis.
INTERNAL GASKET
O-ring front sealing in NBR synthetic rubber, between the case and
the boss.
Brass bushing with double O-ring sealing in NBR synthetic rubber
inside the rear cavity of the base (DD52R-E-SST-IP67).
REAR GASKET
Foam polyethylene, supplied.
STANDARD EXECUTIONS
- DD52R-E-RF-SST-IP65: completely sealed indicator with IP 65
protection class, see EN 60529 table.
- DD52R-E-RF-SST-IP67: completely sealed indicator with IP 67
protection class, see EN 60529 table obtained by means of a brass
bushing with double seal ring inside the rear cavity of the base.
ASSEMBLY INSTRUCTIONS
1. Drill a Ø 6 mm by 10 mm hole in the body of the machine with a 30
mm centre distance from the spindle to fit the rear referring pin.
2. Fit the indicator onto the spindle and make sure that the referring
pin fit the hole.
3. Clamp the boss to the spindle by tightening the grub screw with
hexagon socket and cup end, according to UNI 5929-85.
STAINLESS
STEEL
INOX
RoHS PA PA-T
+50°
0°IP65 IP67
Code Description d
H7
CE.99091 BSA52-E-12 12
CE.99093 BSA52-E-14 14
CE.99094 BSA52-E-15 15
CE.99095 BSA52-E-16 16
CE.99099 BSA52-E-20 20
- BSA52-E: die-cast zinc alloy bases for spindle locking, epoxy resin
coating, black colour, matte finish. GN 302 adjustable handle with
die-cast zinc alloy lever body and AISI 304 stainless steel clamping
element. A Ø 6.1 mm hole to fit the referring pin of the indicator.
Handle positioned either on the right or on the left. Fitting to the
machine by means of two M4 cylindrical-head screws (not included
in the supply).
INOX
RB52-SST
Code Description d
H7
CE.97941 RB52-12-SST-304 12
CE.97951 RB52-14-SST-304 14
CE.97956 RB52-15-SST-304 15
CE.97961 RB52-16-SST-304 16
ACCESSORIES ON REQUEST (TO BE ORDERED SEPARATELY)
- RB52-SST: AISI 304 stainless steel reduction sleeves.

Models all rights reserved in accordance with the law. Always mention the source when reproducing our drawings and photos.
2|3
5
DD52R-E-RF Electronic position indicators
Up to 36
indicators
DD52R-E-R
F
Current position
Target position
UC-RF
Fig.2
PLC
FEATURES AND APPLICATIONS
DD52R-E-RF position indicators, with battery power supply, can be
used on passing through shafts in any position to provide the reading
of the absolute or incremental positioning of a machine component.
- The 6-digit display of 12,0 mm height ensures excellent readability
even from a distance and from different viewing angles.
The window in transparent technopolymer protects the LCD display
against accidental shocks.
- The high protection degree, IP 65 or IP67, makes the indicator suitable
for applications that require frequent washing, even with intense
water jets.
- In the operating mode, by using the 4 function keys, it is possible
to select the incremental or the absolute mode, the unit of measure
(mm, inches or degrees), reset the absolute counter or load a preset
source value and the preset offset value.
- In the programming mode, through the 4 function keys, it is possible
to program the reading after one revolution of the shaft, the direction
of rotation, the display orientation, the resolution (number of decimal
digits displayed), the source value and the offset value, the max.
speed of rotation and set the functions of the keys for the different
options available.
- The internal battery ensures long battery life (over 3 years). A special
symbol appears on the display when it is necessary to replace the
battery. The replacement can be performed easily by removing the
front cover (Fig.1), without disassembly of the indicator from the
control shaft and without the loss of configuration parameters.
QUICK POSITIONING SYSTEM
DD52R-E-RF indicators (Elesa Patent) are networked to the control unit
UC-RF via radio frequency (RF), constituting a wireless system for rapid
positioning of the machine parts (fig.2).
This system is particularly suitable for applications that require frequent
format changes, facilitating the correct adjustment of the target/current
position of the machine parts, also representing a safety system. In
fact, even if a single DD52R-E-RF indicator is not placed in the target
position, PLC doen't allow the beginning of the machine production
cycle, thus avoiding production issues.
The installation of the system is quick and easy as it does not require
the use of connecting cables between the control unit and the indicators.
Further technical information available in "Operating instructions".
Mechanical and electrical characteristics
Tension feed Lithium battery CR2477 3.0 V
Battery life 3 years
Display 6-digit LCD of 12 mm height and
special characters
Reading scale -199999; 999999
Number of decimal digits programmable
(1)
Unit of measure
mm. inches, degrees
programmable
programmable
(1)
Rotation max. speed 300/600/1000 r.p.m
(2)
programmable
(1)
Precision 10.000 impulses / revolution
Protection class IP65 or IP67
Working temperature 0 to 50 °C
Storing temperature -20 to +60 °C
Relative humidity Max. 95% at 25°C without
condensation
Interference protection IEC 61326-1
(1) See the operating instructions.
(2) Default: 600 r.p.m.
Higher rotation speed to 600 r.p.m. can be maintained for short
periods of time.
The value of the max. speed affects the battery life.

Models all rights reserved in accordance with the law. Always mention the source when reproducing our drawings and photos.
3|3
6
DD52R-E-RF Electronic position indicators
DD52R-E-RF-SST-IP65 DD52R-E-RF-SST-IP67
INOX
Code Description
CE.99202 DD52R-E-RF-SST-IP65-C2 129
CE.99201 DD52R-E-RF-SST-IP65-C3 129
CE.99212 DD52R-E-RF-SST-IP67-C2 141
CE.99211 DD52R-E-RF-SST-IP67-C3 141

Models all rights reserved in accordance with the law. Always mention the source when reproducing our drawings and photos.
7
UC-RF
Control unit for DD52R-E-RF
PLC connection, data transmission via radio frequency
RoHS PC ABS
+50°
0°
MATERIAL
ABS reinforced polycarbonate, self-extinguishing.
STANDARD EXECUTIONS
- UC-RF RS232: control unit with RS232 serial interface.
- UC-RF RS485: control unit with RS485 serial interface.
- UC-RF ETHERNET/IP: control unit with Ethernet/IP serial interface.
- UC-RF MODBUS TCP: control unit with Modbus TCP serial interface.
UC-RF control unit can manage up to 36 position indicators. DD52R-E-RF
(see page 4).
Compatible for mounting on DIN RAIL. Two leds (green and red) for
correct diagnostics.
FEATURES AND APPLICATIONS
UC-RF control unit, connected directly to PLC, receives the target
positions and sends them to DD52R-E-RF electronic position indicators,
receiving their current position (Fig.1).
This system is particularly suitable for applications that require frequent
format changes, facilitating the correct adjustment of the target/current
position of the machine parts, also representing a safety system.
In fact, even if a single DD52R-E-RF indicator is not placed in the target
position, PLC doesn't allow the beginning of the machine production
cycle, thus avoiding production issues.
SPECIAL EXECUTION ON REQUEST
Control unit with Profibus serial interface.
Target position
Current position
Up to 36
indicators
DD52R-E-R
F
Fig.1
PLC
Code Description
CE.99221 UC-RF RS232
CE.99223 UC-RF RS485
CE.99225 UC-RF ETHERNET/IP
CE.99229 UC-RF MODBUS TCP
Power supply
24V
A
ntenna
Status LED

ELESA. More and more...
ELESA S.p.A.
Via Pompei, 29
20900 Monza (MB) Italy
phone +39 039 2811.1
fax +39 039 836351
ZDEPDD-RF-ENG18
Printed in Italy
© Copyright ELESA 2018
Other manuals for DD52R-E-RF
3
This manual suits for next models
4
Table of contents
Popular Microphone System manuals by other brands

thomann
thomann The T.Bone TWS One Guitar user manual

LightSpeed Technologies
LightSpeed Technologies 800iX user manual

Audio enhancement
Audio enhancement CAE-20W instruction manual

SC&T
SC&T Active Series user manual

Tekon
Tekon PLUS TWPH-1UT installation guide

Williams Sound
Williams Sound Liberator One Instruction and user's manual