Elettro C.F. PLASMA 36 User manual

01/11/16
ELETTRO CF s.r.l.
1
PLASMA 36 COMPRESSOR
INVERTER
POWER SOURCE art. 481
SERVICE MANUAL

01/11/16
ELETTRO CF s.r.l.
2
CONTENTS
1 – GENERAL INFORMATION .........................................................................................................................3
1.1 – Introduction...........................................................................................................................................3
1.2 – General assistance ................................................................................................................................3
1.3 – Safety information. ...............................................................................................................................3
1.4 – Electromagnetic compatibility..............................................................................................................3
2 – SYSTEM DESCRIPTION..............................................................................................................................4
2.1 – Introduction...........................................................................................................................................4
2.2 – Technical specifications........................................................................................................................4
2.3 – Description power source item 481.......................................................................................................4
3 - MAINTENANCE ............................................................................................................................................5
3.1 – Periodic inspection, cleaning ...............................................................................................................5
3.2 – Operations sequence (pict. 3.2.1)..........................................................................................................5
3.2.1 – Power source commands and signals...............................................................................................5
3.2.2 – Power source operation....................................................................................................................6
3.3 - Troubleshooting.....................................................................................................................................7
3.3.1 – Power source does not start, LED A off ..........................................................................................7
3.3.2 – Power source powered, LED A lit , fan (9) stopped........................................................................8
3.3.3 - Power source powered, the signals do not indicate correct values...................................................8
3.3.4 – Start button produces no effect. .......................................................................................................9
3.3.5 –No gas flows from the torch..............................................................................................................9
3.3.6 – Gas flows from the torch, the pilot arc does not light....................................................................10
3.3.7 – Transfer arc does not take place or is too weak for cutting ...........................................................10
4 – LIST OF SPARE PARTS..............................................................................................................................11
4.1 - Power source item 481.........................................................................................................................11
4.2 - Components table ................................................................................................................................11
4.3 - Spare parts list......................................................................................................................................11
5 – ELECTRICAL DIAGRAMS........................................................................................................................12
5.1 – Power board ........................................................................................................................................12

01/11/16
ELETTRO CF s.r.l.
3
1
- GENERAL INFORMATION
1.1 - Introduction.
The purpose of this manual is to train personnel assigned to carry out maintenance on
the power source art. 481 for plasma cuttingsystems.
1.2 - General service policy.
It is the responsibility of the customer and/or operator to use the equipment appropriately,
in accordance with the instructions in the Instruction Manual, as well as to maintain the
equipment and related accessories in good working condition, in compliance with the
instructions provided in the Service Manual.
Any internal inspection or repairs must be carried out by qualified personnel who are
responsible for any intervention on theequipment.
It is forbidden to attempt to repair damaged electronic boards or modules; replace them
with original ELETTRO CF s.r.l. spareparts.
1.3 - Safety information.
The safety notes provided in this manual are an integral part of those given in the
Instruction Manual. Therefore, before working on the machine, please read the paragraph on
safety instructions in the aforementionedmanual.
Always disconnect the power cord from the mains, and wait for the internal capacitors
to discharge (1 minute) before accessing the interior of theequipment.
Some internal parts, such as terminals and swirl rings, may be connected to mains or
otherwise hazardous potentials. It is therefore forbidden to work with the safety guards
removed from the machine unless strictly necessary. In this case, take special precautions
such as wearing insulating gloves and footwear, and working in a perfectly dry environment
with dryclothing.
1.4 - Electromagnetic compatibility.
Please read and observe the instructions provided in the paragraph “Electromagnetic
compatibility” of the InstructionManual.

01/11/16
ELETTRO CF s.r.l.
4
2
- SYSTEM DESCRIPTION
2.1 - Introduction.
The PLASMA 26 COMPRESSOR INVERTER is a plasma arc system for cutting
electrically conductive materials.
It consists of an electronic power source (item 481) and a series of accessories which allow
its adaptation to several kinds of uses.
The power source is controlled by microprocessor boards, which manage the cutting
system’s operational functions and the operator interface.
2.2 - Technical specifications.
To verify the technical specifications, see the machine plate and Instruction Manual.
2.3 - Description of power source item 481.
Item 481 is a controlled current inverter power source, consisting of a single-phase rectifier
bridge, a PFC module and an IGBT DC/DC converter.
Referring to the wiring diagram, you can identify the main blocks that make the power
source.
The main switch (24) powers the fan (9) and the power board (8) that contains the filter to
reduce conducted interference reflected in the mains, the pre-charge circuit and the PFC
circuit.
The pre-charge resistance limits the amount of current absorbed from the mains, only
during the starting of the machine.
When the group of electrolytic capacitors reaches a certain voltage threshold, the pre-
charge relay short-circuits the pre-charge resistance and only the green LED A remains lit on
the front panel.
The power board (8) is the real cutting current generator, which converts the alternating
voltage at switch (24) input into continuous voltage adjusted according to cutting
requirements.
The adjustment of the cutting current is made by the power board (8) and depends on
signals and parameters set by the power board itself.
The signalling LEDs and the potentiometer for setting working parameters are positioned
in the power board (8).

01/11/16
ELETTRO CF s.r.l.
5
3
- MAINTENANCE
WARNINGS
ANY INTERNAL INSPECTIONS OR REPAIRS MUST BE CARRIED OUT BY
QUALIFIED PERSONNEL.
BEFORE BEGINNING MAINTENANCE OPERATIONS, UNPLUG THE POWER
SOURCE FROM THE MAINS AND WAIT FOR THE INTERNAL CAPACITORS TO
DISCHARGE(1 MINUTE).
3.1 - Periodic inspection, cleaning.
Periodically open the power source grids and check inside the aeration tunnel.
Remove any dirt or dust to ensure smooth air flow, and thus adequate cooling of the
internal parts of the power source.
Check the condition of the output terminals, output and power supply cables of the
power source; replace if damaged.
Check the condition of the internal power connections and connectors on the electronic
boards; if you find “loose” connections, tighten or replace theconnectors.
3.2 - Operating sequence (pict. 3.2.1).
The following sequence represents correct functioning of the machine. It may be used
as a guiding procedure fortroubleshooting.
It must be carried out after each repair without anyerrors.
3.2.1 - Power source commands and signals.

01/11/16
ELETTRO CF s.r.l.
6
3.2.2 - Power source operation.
NOTE
Operations marked with this symbol refer to operatoractions.
The operations marked with this symbol refer to machine responses that must occur
following an operator action.
System shut off and unplugged from themains.
Connect the cable of the positive pole of the power source to theworkpiece.
Connectthepowersourcetothemains.
Close the switch (H) on the power source.
System powered, led (A) lit, fan running.
On front panel, leds (C) and (D) off; led (B) lit for the first 5 seconds
(analysis phase), then off
Correct? NO (see 3.3.1, 3.3.2, 3.3.3).
YES
DURING THE FOLLOWING TESTS, DO NOT POINT THE TORCH AT PEOPLEOR
PARTS OF THE BODY, BUT ALWAYS TOWARDS AN OPEN SPACE OR THE
WORKPIECE.
Press thetorchstartbutton and hold it down.
Gas flows from the torch and the pilot arc starts for the maximum pilot arc
time (2 sec.). The gas continues to flow for approximately another 100 sec.
after the start button is released (post-gas time).
Correct? NO (see 3.3.4, 3.3.5, 3.3.6).
YES
With pilot arc lit, place the torch close to the workpiece.
Begin cutting.
Correct? NO (see 3.3.7).
YES
Releasethetorchstartbutton.
The arc shuts off immediately. The gas continues to flow for the post-gas time
(approximately 100 seconds after the start button is released) to cool thetorch.
Correct? NO (see 3.3.5).
YES
REGULAR OPERATION.

01/11/16
ELETTRO CF s.r.l.
7
3.3 - Troubleshooting.
WARNINGS
ANY INTERNAL INSPECTION OR REPAIR MUST BE PERFORMED BY QUALIFIED
PERSONNEL.
BEFORE REMOVING THE PROTECTION COVERS AND ACCESSING INTERNAL PARTS,
DISCONNECT THE MACHINE FROM THE MAINS AND AND WAIT FOR THE INTERNAL
CAPACITORS TO DISCHARGE (1 MINUTE).
NOTE
Items in boldface describe problems that may occur on the machine(symptoms).
Steps marked with this symbol refer to situations for which the operator must determine the
causes (causes).
Operations preceded by this symbol refer to actions the operator must perform in order to
solve the problems (solutions).
3.3.1 - The power source does not start, led (A) off.
MAINS SUITABILITY TEST.
No voltage at the power source input, because the mains surge protector istripped.
NO
Correct?
YES
Eliminate any short-circuits in the connections between the power cable, switch
(24) and power board (8).
Mains not suited to power the power source (ex.: insufficient installed power).
MAINS CONNECTION TEST.
Input terminals J2 – J3 on power board (8) = 230 Vac approx., with switch (24) closed.
YES
Correct?
NO
Check power cable and plug and replace if necessary.
Check the switch (24) and replace if defective.
Check the mains voltage conditions.
Check the integrity of the rectifier bridge DS1 on power board (8).
POWER BOARD PRE-CHARGE TEST (8).
Power board (8), pre-charge relay K1 closes when the machine is switched-on.
YES
Correct?
NO
Check working conditions of relay K1
Check working conditions of pre-charge resistance PT1
Replace the power board (8)
Replace the power board (8).

01/11/16
ELETTRO CF s.r.l.
8
3.3.2 - Power source powered, led (A) lit, fan (9) stopped.
FAN (9) TEST.
Fan (9) fast-on terminals = 230 Vac, approximately, after closing switch (24).
NO
Correct?
YES
Make sure that there are no mechanical impediments blocking the fan (9).
Replace the fan (9).
Check the wiring between fan (9) and connector J2 and J3 on power board(8).
Check the presence of 230V approx. on switch (24).
Check the switch (24) and replace if defective.
3.3.3 – Power source powered, the signals do not indicate correct values.
LED (D) steady lit, insufficient air.
-Carry out the compressor test, see par. 3.3.5.
LED (C) steady lit, thermal protection.
-Check the working conditions of thermostat and replace if defective.
-Replace the power board (8).
LED (B) steady lit, power source blocked.
This indicator indicates that the power source is in an analysis phase, in the first 5 seconds
after closing the switch (24), or, thereafter, is blocked due to a hazardous condition. Check
the value of supply voltage.
If previous steps have not solved the problem, replace the power board (8).

01/11/16
ELETTRO CF s.r.l.
9
3.3.4 – Pressing start button produces no effect.
START COMMAND TEST.
Press the torch button and check the electrical continuity between torch button contacts on terminals
1-2 of connector J16 on power board (8).
YES
Correct?
NO
Check wiring between terminals 1 – 2 of J16 and the torch (16).
Check that the nozzle protection is properly mounted on the torch and in good
working conditions. If defective or showing signs of wear, replace.
Check the torch button. If defective, replace it.
Replace the power board (8).
Replace the power board (8).
3.3.5 – No air flows from the torch.
COMPRESSOR (10) TEST.
Compressor terminals (10) = 230 Vac approx. with the torch button pressed and for the post-gas
time.
YES
Correct?
NO
Check the wiring between the compressor (10) and J4 of power board (8).
Replace the power board (8).
Replace the compressor (10).

01/11/16
ELETTRO CF s.r.l.
10
3.3.6 –Gas flows from the torch, but the pilot arc does not light.
Pressing the torch button, the pilot arc lights
YES
Correct?
NO
Check the conditions of torch consumables. If showing signs of wear, replace.
Check wiring between terminals 3 of J16 and torch (16).
Check the working conditions of pilot arc relay K2 on the power board (8).
Replace power board (8).
Regular operation
3.3.7 – Transfer arc does not take place or is too weak for cutting.
TRANSFER ARC SWITCHING TEST
Make sure that with the torch close to the workpiece and the pilot arc lit, the reed relay contact L3
on power board (8) closes.
NO
Correct?
YES
Check the working conditions of relay K3 on power board (8).
Make sure that the earth cable (27) is connected to the workpiece.
Check the wiring between the earth cable (27) and the connector J17 on power
board (8).
Check the wiring between the torch (16) and the connector J18 on power board
(8).
Replace the power board (8).
Replace the power board (8)

01/11/16
ELETTRO CF s.r.l.
11
4
- COMPONENTS LIST
4.1 - Power source art. 481
4.2 - Table of components
4.3 - List of spare parts.
Essential spare parts.
Ref. Description Qty.
8powe
r
b
oard 1
Recommended spare parts.
Ref. Description Qty.
09 fan 1
24 switch 1

01/11/16
ELETTRO CF s.r.l.
12
5
– ELECTRICAL DIAGRAMS
5.1 – Power board (8)
5.1.1 - Topographical drawing.
5.1.2 - Connector table.
J2
–
J3 230 Vac supply voltage input.
J4
1 - 2
230 Vac output for compressor (10).
J6
1
–
2
compressor (10) thermal signal input.
J16
1
–
2
“start” signal input from torch (16) button
J16
3
output for torch (16) nozzle
J
17 output for earth cable (27)
J18 output for torch (16) electrode

01/11/16
Art./Item 481
Ricambi - Spare parts - Ersatzteile – Pièces de rechange - Piezas de repuesto – Peças

01/11/16
La richiesta di pezzi di ricambio deve indicare sempre: l' art. e la data d'acquisto della macchina, la posizione e la quantità dei pezzi di ricambio.
In case spare parts are required please always indicate: item ref. no. and purchase date of the machine, spare part position no. and quantity.
In der Ersatzteilanfrage müssen immer Art. und Einkaufsdatum des Apparat, Ersatzteil-Nr. und Menge angegeben werden.
En cas de demande de pièces de rechange, toujours indiquer: l'article et la date d'achat de la machine, la position et la quantité des pièces.
Los pedidos de piezas de repuesto deben indicar siempre: el numero de articulo y la fecha de adquisición del aparato, la posición y la cantidad de las
piezas.
O pedido de peças deve indicar sempre o modelo da máquina em causa e a data de aquisição da mesma, a posição e a quantidade de peças
pedidas.
POS. DESCRIZIONE DESCRIPTION STÜCKLISTE DESIGNATION DENOMINACIÓN DESCRIÇÃO
1 SUPPORTO MANICO HANDLE HOLDER GRIFF HALTER SUPPORT MANCHE SOPORTE MANIJA SUPORTE PEGA
2 MANICO HANDLE GRIFF MANCHE MANGO PEGA
3 FASCIONE HOUSING GEHÄUSE CARROSSERIE CARCASA INVÓLUCRO
4 FONDO BOTTOM BODENBLECH FOND FONDO BASE
5 PIANO INTERMEDIO INTERMEDIATE
PANEL ZWISCHENWANDFLÄCHE PANNEAU
INTERMEDIAIRE PANEL INTERMEDIO PAINEL INTERMÉDIO
6 SUPPORTO
COMPRESSORE COMPRESSOR
HOLDER KOMPRESSORTRÄGER SUPPORT
COMPRESSEUR SOPORTE
COMPRESOR SUPORTE
COMPRESSOR
7 CORNICE FRAME RAHMEN CADRE MARCO CAIXILHO
8 CIRCUITO POTENZA POWER CIRCUIT LEISTUNGS-PLATINE CIRCUIT PUISSANCE CIRCUITO POTENCIA CIRCUITO POTÊNCIA
9 VENTILATORE FAN VENTILATOR VENTILATEUR VENTILADOR VENTAROLA
10 COMPRESSORE COMPRESSOR KOMPRESSOR COMPRESSEUR COMPRESOR COMPRESSOR
11 DISTANZIALE SPACER DISTANZSTÜCK ENTRETOISE DISTÁNCIALE ESPAÇADOR
12 PIEDINO SUPPORT HALTERUNG SUPPORT SOPORTE SUPORTE
13 BLOCCA CAVO CABLE GLAND KABELVERSCHRAUBUNG PRESSE-ETOUPE PRENSA CABLE PRENSA CABO
14 DISTANZIALE SPACER DISTANZSTÜCK ENTRETOISE DISTÁNCIALE ESPAÇADOR
15 SUPPORTO
ANTIVIBRANTE SHOCK ABSORBER ANTIVIBRATIONSPUFFER TAMPON ANTI-
VIBRATIONS APOYO
ANTIVIBRACIÓN APOIO ANTI-
VIBRAÇÃO
16 TORCIA COMPLETA COMPLETE TORCH BRENNER TORCHE COMPLETE
ANTORCHA
COMPLETA TOCHA COMPLETA
17 ELETTRODO ELECTRODE ELEKTRODE ELECTRODE ELECTRODO ELÉCTRODO
18 DIFFUSORE
ISOLANTE INSULATING
DIFFUSOR ISOLIERENDER DIFFUSOR DIFFUSEUR ISOLANT DIFUSOR AISLANTE DIFUSOR ISOLADOR
19 UGELLO NOZZLE DÜSE BUSE TOBERA INJECTOR
20 PORTAUGELLO NOZZLE HOLDER DÜSENHALTER PORTE-BUSE PORTA - INYECTOR PORTA INJECTOR
21 TUBO TEFLON TEFLON TUBE PTFE-SCHLAUCH TUYAU EN PTFE PTFE TUBERÍA TUBO DE PTFE
22 PASSACAVO STRAIN RELIEF ZUGENTLASTUNG PASSE CABLE PASA CABLE PASSA CABO
23 PORTA-LED LED HOLDER LED-HALTER SUPPORT LED SOPORTE LED SUPORTE LED
24 INTERRUTTORE SWITCH SCHALTER INTERRUPTEUR INTERRUPTOR INTERRUPTOR
25 CAVO RETE MAINS INPUT
CABLE NETZ-
ANSCHLUSSLEITUNG CABLE - RESEAU CABLE RED CABO DE
ALIMENTAÇÃO
26 PROTEZIONE PROTECTION SCHUTZ PROTECTION PROTECCIÓN PROTECÇÃO
27 CAVO MASSA EARTH CABLE MASSEKABEL CABLE DE TERRE CABLE MASA CABO MASSA
28 RACCORDO CONNECTOR VERBINDUNGSSTÜCK RACCORD EMPALME LIGAÇÃO
29 PASSACAVO STRAIN RELIEF ZUGENTLASTUNG PASSE CABLE PASA CABLE PASSA CABO
30 BLOCCA CAVO CABLE GLAND KABELVERSCHRAUBUNG PRESSE-ETOUPE PRENSA CABLE PRENSA CABO
31 RACCORDO JOINT VERBINDUNGSSTÜCK RACCORD EMPALME LIGAÇÃO
45 IMPUGNATURA HANDLE GRIFF POIGNEE EMPUÑADURA PUNHO
46 TESTINA HEAD SCHNEIDKOPF TÊTE CABEZA CABECINHA
47 MANOPOLA KNOB DREHKNOPF BOUTON MANOPLA BOTÃO

01/11/16

01/11/16
Codifica colori Wiring diagram
Farben-Codierung Codification Codificación Codificação cores
elektrische couleurs schéma colores cableado conjunto eléctrico
cablaggio elettrico colour code Schaltplan électrique eléctrico de cabos
ANero Black Schwarz Noir Negro Negro
BRosso Red Rot Rouge Rojo Vermelho
CGrigio Grey Grau Gris Gris Cinzento
DBianco White Weiss Blanc Blanco Branco
EVerde Green Gruen Vert Verde Verde
FViola Purple Violett Violet Violeta Violeta
GGiallo Yellow Gelb Jaune Amarillo Amarelo
HBlu Blue Blau Bleu Azul Azul
KMarrone Brown Braun Marron Marron Castanho
JArancione Orange Orange Orange Nardnja Alaranjado
IRosa Pink Rosa Rose Rosa Rosa
LRosa-nero Pink-black Rosa-schwarz Rose-noir Rosa-negro Rosa-negro
MGrigio-viola Grey-purple Grau-violett Gris-violet Gris-violeta Cinzento-violeta
NBianco-viola White-purple Weiss-violett Blanc-violet Blanco-violeta Branco-violeta
OBianco-nero White-black Weiss-schwarz Blanc-noir Blanco-negro Branco-negro
PGrigio-blu Grey-blue Grau-blau Gris-bleu Gris-azul Cinzento-azul
QBianco-rosso White-red Weiss-rot Blanc-rouge Blanco-rojo Branco-vermelho
RGrigio-rosso Grey-red Grau-rot Gris-rouge Gris-rojo Cinzento-vermelho
SBianco-blu White-blue Weiss-blau Blanc-bleu Blanco-azul Branco-azul
TNero-blu Black-blue Schwarz-blau Noir-bleu Negro-azul Negro-azul
UGiallo-verde Yellow-green Gelb-gruen Jaune-vert Amarillo-verde Amarelo-verde
Other manuals for PLASMA 36
1
This manual suits for next models
1
Table of contents
Popular Inverter manuals by other brands

SMA
SMA Sunny Island SI3300 Installation & operating instructions

Toshiba
Toshiba TOSVERT VF-S15 series Communication Function Manual

Sincro
Sincro SK315 Series Use and maintenance manual

Sime
Sime PLANO 272 Installation & servicing instructions

Redilight
Redilight Spectra installation instructions

Samlexpower
Samlexpower PST-15S-12A owner's manual