Elikon 2Easy EVD2-CC4C User manual

Please read this manual carefully before using the product you
purchase, and keep it well for future use.We reserve the right to
modify the specication in this manual at any time without notice.
2-Wire System
Power In-Use
Camera Interface
Model: EVD2-CC4C
CAM(1~4)
CAM1 CAM2
CAM3 CAM4
User Manual
ikon
EVD2-CC
4
C

DIP
RS485
CAM3
CAM4
BUS(IN)
BUS(OUT)
123456
ON
CAM2
CAM1
123456
ON
2-Wire System
Power In-Use
Camera Interface
Model: EVD2-CC4C
CAM(1~4)
CAM1 CAM2
CAM3 CAM4
INDICATORS BUTTONS
-1-
1.About EVD2-CC4C Unit
Description:
The camera interface EVD2-CC4C is a controller function device designed
for Elikon system to control camera. In addition, EVD2-CC4C can be
configured as camera converter working mode to fit before used distribuide
camera accessory of the project. For details, see later section 5.
2. Terminal Description
RS485:Reserved.
CAM1~2:Connect to
regular analog CCTV(the following called TYPE A Camera)
.
CAM3~4:Connect to
2 wire camera(the following called TYPE B Camera ); If
you want to connect CCTV to this port, it must be connected camera converter,
then the port can work usually(The camera converter is used to transform the 2
wire camera to analogue camera,for details, see camera converter manual).
BUS(IN):Connect to the bus line, no polarity.
BUS(OUT):Connect to the bus line, no polarity.
BUTTONS:Press CAM1~CAM4 button, it can control the corresponding
video output.
ikon EVD2-CC
4
C

-2-
1 2 3 4 5 6
ON
1 2 34 5 6
ON
1 2 345 6
ON
1 2 3 4 56
ON
Bit
DIP1~DIP2
set to the first EVD2-CC4C.
DIP3
DIP4
DIP5
DIP6
Bit State Description
1 2 3 4 56
ON
TYPE A Camera used. When EVD2-CC4C connected TYPE A Camera, it
should be set to ON.
TYPE B Camera used. When EVD2-CC4C connected TYPE B Camera, it
should be set to ON.
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
1 2 3 4 5 6
ON
set to the second EVD2-CC4C.
set to the third EVD2-CC4C.
set to the fourth EVD2-CC4C.
When all EVD2-CC4C of the system are configured to connect the two
cameras(two TYPE A Cameras or two TYPE B Cameras ), it should be set to ON
When all EVD2-CC4C of the system are configured to connect the four
cameras(two TYPE A Cameras and two TYPE B Cameras ), it should be set to
OFF.
When the system connected programer, and programer connected two
cameras(the two cameras of the device is valid),it should be set to ON;
When the system don’t connected programer(or connected programer, but
programer don’t connected camera), it should be set to OFF.
INDICATORS:
1.Power: Working indicator, always on when the EVD2-CC4C work normally.
2.In-Use:Video output indicator, always on when the EVD2-CC4C output the video.
3.CAM(1~4):Video output indicator.
In-Use CAM(1~4) Description
CAM1 video output
CAM2 video output
CAM3 video output
CAM4 video output
*NOTE:
:It shows that the indicator ON;
:It shows that the indicator OFF.
DIP:DIP switches.
ikon EVD2-CC
4
C

-3-
3. Unit Mounting
Din rail
Din rail
Mounting Buckle
Step1: Mount the din rail to
the wall with screws ;
Step2: Pull down the
mounting buckle,then hang
the unit on din rail.
ikon EVD2-CC
4
C

-4-
RF CARD
BUS(IM) BUS(DS)
EVD2-624
AC~
BUS(IN) BUS(OUT)
EVD2-CC4C
1 2 3 4 5 6
ON
1# CCTV
2# CCTV
DT-CCU
Camera
BUS
GND VIDEO
BUS BUS 2-WIRESYSTEM
GND
VEDIO
DT-CCU
Camera
BUS
GND VIDEO
BUS BUS 2-WIRESYSTEM
GND
VEDIO
3# CCTV
4# CCTV
4. Wiring Diagram
4.1 Single door station and single EVD2-CC4C applications:
ikon EVD2-CC
4
C

-5-
4.2 Multi door station and two EVD2-CC4C (connected two
TYPE A
Cameras
) applications:
RF CARD
BUS(IM) BUS(DS)
EVD2-CC4C
AC~
BUS(IN) BUS(OUT)
EVD2-CC4C
1 2 3 4 5 6
ON
EVD2-OD4C
A B C D
RF CARD
(Device Address:1) (Device Address:0)
BUS(IN) BUS(OUT)
1 2 3 4 5 6
ON
a b
3# CCTV
4# CCTV
1# CCTV
2# CCTV
ikon EVD2-CC
4
C
EVD2-CC4C

-6-
4.3 Multi door station and two EVD2-CC4C (connected two
TYPE B
Cameras
)applications:
RF CARD
BUS(IM) BUS(DS)
EVD2-624
AC~
EVD2-OD4C
A B C D
RF CARD
(Device Address:1) (Device Address:0)
BUS(IN) BUS(OUT)
EVD2-CC4C
1 2 3 4 5 6
ON
BUS(IN) BUS(OUT)
1 2 3 4 5 6
ON
a b
CONVERTER
Camera
BUS
GND VIDEO
BUS BUS 2-WIRE SYSTEM
GND
VEDIO
CONVERTER
Camera
BUS
GND VIDEO
BUS BUS 2-WIRE SYSTEM
GND
VEDIO
1# CCTV
2# CCTV
CONVERTER
Camera
BUS
GND VIDEO
BUS BUS 2-WIRE SYSTEM
GND
VEDIO
CONVERTER
Camera
BUS
GND VIDEO
BUS BUS 2-WIRE SYSTEM
GND
VEDIO
3# CCTV
4# CCTV
NOTE: The system can connect programer(programer connected two
TYPE B
Cameras
), but at this time, the DIP6 of EVD2-CC4C must be set to ON.
ikon EVD2-CC
4
C
EVD2-CC4C

In the program state, press and
hold "CAM1" button for 3 seconds
to switch the working mode. Then
it will return to standby
Working mode indicator:CAM(1~4)
(ash once)
-8-
2).Working mode configuration, the camera switching time setting, and
monitoring time setting.
In the standby, press and hold
"CAM4" button for 3 seconds, it will
enter the state of program.
indicator:IN-USE
(ash)
[SCU mode] [DCU mode]:
[DCU mode] [SCU mode]: (ash twice)
In the program state, press
and hold "CAM2" button for 3
seconds, it will enter the state of
camera switching time setting.
(1)the left light of indicator CAM (1 ~ 4)
starts ashing (ash once per second);
(2)Flash once to increase 3 seconds;
(3)Press any button to conrm the
setting and return to standby.
Note:
1. The maximum can be set to
99 seconds, to 99 seconds, then
automatically save and return to standby.
2. 6 seconds by default.
In the program state, press
and hold "CAM3" button for 3
seconds, it will enter the state of
monitoring time setting.
(1)the right light of indicator CAM (1 ~ 4)
starts ashing (ash once per second);
(2)Flash once to increase 15 seconds;
(3)Press any button to conrm the
setting and return to standby.
Note:
1. The maximum can be set to 900
seconds, to 900 seconds, then
automatically save and return to standby.
2. 600 seconds by default.
Note:In program state, if there isn’t any operation within 10s, or press any button, it will
return to standby.
ikon EVD2-CC
4
C

6. Specification
•Power Supply : DC24V;
•Working Temperature: -150C~+550C;
•Wiring: 2 wire,non-polarity;
•Dimension: 90(H)×72(W)×60(D)mm.
The design and specifications can be changed without notice to the user. Right to interpret
and copyright of this manual are preserved.
ikon EVD2-CC
4
C
Table of contents
Popular Control Unit manuals by other brands

mikroElektronika
mikroElektronika Click Boards IR distance click manual

AERMEC
AERMEC VCZ41 installation manual

Puls
Puls DIMENSION UC10 Series instruction manual

suprema
suprema Secure I/O 2 installation guide

SWT
SWT TECH-EE Series troubleshooting guide

UTC Fire and Security
UTC Fire and Security interlogix VAR14120 Installation & operation instructions