GEM eSyLite 629 User manual

GEMÜ 629 eSyLite
Motorized diaphragm valve
Operating instructions
EN
further information
webcode: GW-629

All rights including copyrights or industrial property rights are expressly reserved.
Keep the document for future reference.
© GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG
29.06.2021
www.gemu-group.com2 / 41GEMÜ 629 eSyLite

Contents
1 General information ............................................. 4
1.1 Information .................................................... 4
1.2 Symbols used ................................................ 4
1.3 Definition of terms ........................................ 4
1.4 Warning notes ............................................... 4
2 Safety information ............................................... 5
3 Product description ............................................. 5
3.1 Construction .................................................. 5
3.2 Description ..................................................... 6
3.3 Function ......................................................... 6
3.4 Product label ................................................. 6
4 GEMÜ CONEXO .................................................... 6
5 Correct use .......................................................... 6
6 Order data ........................................................... 7
6.1 Order codes ................................................... 7
6.2 Order example ............................................... 10
7 Technical data ..................................................... 11
7.1 Medium .......................................................... 11
7.2 Temperature .................................................. 11
7.3 Pressure ......................................................... 11
7.4 Product compliance ...................................... 13
7.5 Mechanical data ............................................ 13
7.6 Duty cycle and service life ............................ 15
8 Dimensions .......................................................... 16
8.1 Actuator dimensions without position indic-
ator ................................................................. 16
8.2 Actuator dimensions with GEMÜ 1215 posi-
tion indicator .................................................. 17
8.3 Body dimensions ........................................... 18
9 Manufacturer's information .................................. 29
9.1 Delivery .......................................................... 29
9.2 Transport ....................................................... 29
9.3 Storage ........................................................... 29
10 Installation in piping ............................................ 29
10.1 Preparing for installation .............................. 29
10.2 Installation position ....................................... 30
10.3 Installation with clamp connections ............ 30
10.4 Installation with butt weld spigots ............... 30
10.5 Installation with threaded sockets ............... 30
10.6 Installation with threaded spigots ................ 30
10.7 Installation with flanged connection ............ 31
11 Electrical connection ........................................... 32
12 Operation ............................................................. 33
12.1 Manual override ............................................. 33
14 Inspection and maintenance ................................ 35
14.1 Spare parts .................................................... 35
14.2 Removing the actuator .................................. 35
14.3 Removing the diaphragm .............................. 35
14.4 Mounting the compressor ............................ 36
14.5 Mounting the diaphragm .............................. 36
14.6 Mounting the actuator .................................. 37
15 Removal from piping ............................................ 37
16 Disposal .............................................................. 37
17 Returns ................................................................ 37
18 Declaration of Incorporation according to
2006/42/EC (Machinery Directive) ....................... 38
19 Declaration of conformity according to 2014/68/
EU (Pressure Equipment Directive) ...................... 39
20 Declaration of conformity according to 2014/30/
EU (EMC Directive) ............................................... 40
GEMÜ 629 eSyLitewww.gemu-group.com 3 / 41

www.gemu-group.com4 / 41GEMÜ 629 eSyLite
1 General information
1 General information
1.1 Information
•The descriptions and instructions apply to the standard ver-
sions. For special versions not described in this document
the basic information contained herein applies in combina-
tion with any additional special documentation.
•Correct installation, operation, maintenance and repair work
ensure faultless operation of the product.
•Should there be any doubts or misunderstandings, the Ger-
man version is the authoritative document.
•Contact us at the address on the last page for staff training
information.
1.2 Symbols used
The following symbols are used in this document:
Symbol Meaning
Tasks to be performed
Response(s) to tasks
– Lists
1.3 Definition of terms
Working medium
The medium that flows through the GEMÜ product.
Diaphragm size
Uniform seat size of GEMÜ diaphragm valves for different
nominal sizes.
1.4 Warning notes
Wherever possible, warning notes are organised according to
the following scheme:
SIGNAL WORD
Type and source of the danger
Possible
symbol for the
specific
danger
Possible consequences of non-observance.
Measures for avoiding danger.
Warning notes are always marked with a signal word and
sometimes also with a symbol for the specific danger.
The following signal words and danger levels are used:
DANGER
Imminent danger!
▶Non-observance can cause death or
severe injury.
WARNING
Potentially dangerous situation!
▶Non-observance can cause death or
severe injury.
CAUTION
Potentially dangerous situation!
▶Non-observance can cause moderate
to light injury.
NOTICE
Potentially dangerous situation!
▶Non-observance can cause damage to
property.
The following symbols for the specific dangers can be used
within a warning note:
Symbol Meaning
Danger of explosion
Corrosive chemicals!
Hot plant components!
Damage to the product

www.gemu-group.com 5 / 41 GEMÜ 629 eSyLite
2 Safety information
The safety information in this document refers only to an indi-
vidual product. Potentially dangerous conditions can arise in
combination with other plant components, which need to be
considered on the basis of a risk analysis. The operator is re-
sponsible for the production of the risk analysis and for com-
pliance with the resulting precautionary measures and re-
gional safety regulations.
The document contains fundamental safety information that
must be observed during commissioning, operation and main-
tenance. Non-compliance with these instructions may cause:
•Personal hazard due to electrical, mechanical and chemical
effects.
•Hazard to nearby equipment.
•Failure of important functions.
•Hazard to the environment due to the leakage of dangerous
materials.
The safety information does not take into account:
•Unexpected incidents and events, which may occur during
installation, operation and maintenance.
•Local safety regulations which must be adhered to by the
operator and by any additional installation personnel.
Prior to commissioning:
1. Transport and store the product correctly.
2. Do not paint the bolts and plastic parts of the product.
3. Carry out installation and commissioning using trained
personnel.
4. Provide adequate training for installation and operating
personnel.
5. Ensure that the contents of the document have been fully
understood by the responsible personnel.
6. Define the areas of responsibility.
7. Observe the safety data sheets.
8. Observe the safety regulations for the media used.
During operation:
9. Keep this document available at the place of use.
10. Observe the safety information.
11. Operate the product in accordance with this document.
12. Operate the product in accordance with the specifications.
13. Maintain the product correctly.
14. Do not carry out any maintenance work and repairs not de-
scribed in this document without consulting the manufac-
turer first.
In cases of uncertainty:
15. Consult the nearest GEMÜ sales office.
3 Product description
3.1 Construction
1
2
3
5
4
6
7
8
9
Item Name Materials
1 Optical position in-
dicator
PA 12
2 Manual override
3 Motorized actu-
ator
Reinforced polyamide
4 CONEXO actuator
RFID chip
5 Diaphragm CR, EPDM, FKM, NBR, PTFE/EPDM
6 CONEXO dia-
phragm RFID chip
7 CONEXO body
RFID chip
8 Valve body EN-GJL-250 (GG 25)
EN-GJS-400-18-LT (GGG 40.3), PFA
lined
EN-GJS-400-18-LT (GGG 40.3), PP
lined
EN-GJS-400-18-LT (GGG 40.3),
hard rubber lined
1.4408, investment casting
1.4408, PFA lined
1.4435 (F316L), forged body
1.4435 (BN2), forged body, Δ Fe <
0.5 %
1.4435, investment casting
1.4539, forged body
9 Electrical connec-
tion
3 Product description

www.gemu-group.com6 / 41GEMÜ 629 eSyLite
4 GEMÜ CONEXO
3.2 Description
The GEMÜ 629 eSyLite 2/2-way diaphragm valve is motorized.
It is available as an OPEN/CLOSE version. An integral optical
position indicator is standard. The self-locking actuator holds
its position in a stable manner in the event of power supply
failure.
3.3 Function
The product controls or regulates (depending on version) a
flowing medium by being closed or opened by a motorized ac-
tuator.
The product has an optical position indicator as standard. The
optical position indicator indicates the OPEN and CLOSED po-
sitions.
3.4 Product label
The product label is located on the actuator. Product label
data (example):
Design in accordance with order data
Device-specific data
Year of manufacture
Item number Traceability number Consecutive number
- XXXXXXXX|YYYY
The month of manufacture is encoded in the traceability num-
ber and can be obtained from GEMÜ. The product was manu-
factured in Germany.
The operating pressure stated on the product label applies to
a media temperature of 20 °C. The product can be used up to
the maximum stated media temperature. You can find the
pressure/temperature correlation in the technical data.
4 GEMÜ CONEXO
The interaction of valve components that are equipped with
RFID chips and an associated IT infrastructure actively in-
crease process reliability.
Thanks to serialization, every valve and every relevant valve
component such as the body, actuator or diaphragm, and
even automation components, can be clearly traced and read
using the CONEXO pen RFID reader. The CONEXO app, which
can be installed on mobile devices, not only facilitates and im-
proves the "installation qualification" process, but also makes
the maintenance process much more transparent and easier
to document. The app actively guides the maintenance techni-
cian through the maintenance schedule and directly provides
him with all the information assigned to the valve, such as
test reports, testing documentation and maintenance histor-
ies. The CONEXO portal acts as a central element, helping to
collect, manage and process all data.
For further information on GEMÜ CONEXO please visit:
www.gemu-group.com/conexo
5 Correct use
DANGER
Danger of explosion
▶Risk of death or severe injury.
●Do not use the product in potentially
explosive zones.
WARNING
Improper use of the product
▶Risk of severe injury or death.
▶Manufacturer liability and guarantee will be void.
●Only use the product in accordance with the operating
conditions specified in the contract documentation and in
this document.
The product is designed for installation in piping systems and
for controlling a working medium.
The product is not intended for use in potentially explosive
areas.
●Use the product in accordance with the technical data.

6 Order data
The order data provide an overview of standard configurations.
Please check the availability before ordering. Other configurations available on request.
Order codes
1 Type Code
Diaphragm valve, motorized,
stainless steel diaphragm valve
629
2 DN Code
DN 4 4
DN 6 6
DN 8 8
DN 10 10
DN 12 12
DN 15 15
DN 20 20
DN 25 25
DN 32 32
DN 40 40
3 Body configuration Code
Tank bottom valve body B
Body configuration code B: Dimensions and
designs on request
2/2-way body D
T body T
Body configuration code T: For dimensions, see T
Valves brochure
4 Connection type Code
Spigot
Spigot DIN 0
Spigot EN 10357 series B,
formerly DIN 11850 series 1
16
Spigot EN 10357 series A (formerly DIN 11850
series 2)/DIN 11866 series A
17
Spigot DIN 11850 series 3 18
Spigot JIS-G 3447 35
Spigot JIS-G 3459 schedule 10s 36
Spigot SMS 3008 37
Spigot BS 4825, part 1 55
Spigot ASME BPE / DIN 11866 series C 59
Spigot ISO 1127/EN 10357 series C/DIN 11866
series B
60
Spigot ANSI/ASME B36.19M schedule 10s 63
Spigot ANSI/ASME B36.19M schedule 5s 64
Spigot ANSI/ASME B36.19M schedule 40s 65
Threaded connection
Threaded socket DIN ISO 228 1
Threaded socket NPT 31
4 Continuation of Connection type Code
Threaded spigot DIN 11851 6
Cone spigot and union nut DIN 11851 6K
Flange
Flange EN 1092, PN 16, form B,
face-to-face dimension FTF EN 558 series 1, ISO
5752, basic series 1,
length only for body configuration D
8
Flange ANSI Class 150 RF,
face-to-face dimension FTF MSS SP-88,
length only for body configuration D
38
Flange ANSI Class 125/150 RF,
face-to-face dimension FTF EN 558 series 1, ISO
5752, basic series 1,
length only for body configuration D
39
Clamp
Clamp ASME BPE,
face-to-face dimension FTF ASME BPE,
length only for body configuration D
80
Clamp DIN 32676 series B,
face-to-face dimension FTF EN 558 series 7,
length only for body configuration D
82
Clamp ASME BPE,
face-to-face dimension FTF EN 558 series 7,
length only for body configuration D
88
Clamp DIN 32676 series A,
face-to-face dimension FTF acc. to EN 558 series
7,
length only for body configuration D
8A
Clamp ISO 2852/SMS 3017,
face-to-face dimension FTF EN 558 series 7,
length only for body configuration D
8E
Clamp DIN 32676 series C,
face-to-face dimension FTF ASME BPE,
length only for body configuration D
8P
Clamp DIN 32676 series C,
face-to-face dimension FTF EN 558 series 7,
length only for body configuration D
8T
5 Valve body material Code
Cast iron material
EN-GJL-250 (GG 25) 8
SG iron material
EN-GJS-400-18-LT (GGG 40.3),
PFA lined
17
EN-GJS-400-18-LT (GGG 40.3),
PP lined
18
EN-GJS-400-18-LT (GGG 40.3),
hard rubber lined
83
6 Order data
www.gemu-group.com 7 / 41 GEMÜ 629 eSyLite

5 Continuation of Valve body material Code
Investment casting material
1.4408, investment casting 37
1.4408, PFA lined 39
1.4435, investment casting C3
Forged material
1.4435 (F316L), forged body 40
1.4435 (BN2), forged body, Δ Fe < 0.5 % 42
1.4539, forged body F4
6 Diaphragm material Code
NBR 2
EPDM 3A
FKM 4
FKM 4A
CR 8
EPDM 13
EPDM 17
EPDM 19
EPDM 29
EPDM 36
PTFE/EPDM one-piece 54
PTFE/EPDM two-piece 5M
7 Voltage/Frequency Code
24 V DC C1
8 Control module Code
Open/Close control (economy) A0
Open/Close control (economy),
with emergency power supply module (NC)
A1
Open/Close control (economy),
with emergency power supply module (NO)
A2
Open/Close control, mounted position indicator
GEMU 1215
Z0
Open/Close control, mounted position indicator
GEMU 1215,
emergency power supply module (NC)
Z1
Open/Close control, mounted position indicator
GEMU 1215,
emergency power supply module (NO)
Z2
9 Surface Code
Ra ≤ 6.3 μm (250 μin.) for media wetted surfaces,
mechanically polished internal
1500
Ra ≤ 0.8 µm (30 µin.) for media wetted surfaces,
in accordance with DIN 11866 H3,
mechanically polished internal
1502
Ra ≤ 0.8 µm (30 µin.) for media wetted surfaces,
in accordance with DIN 11866 HE3,
electropolished internal/external
1503
Ra ≤ 0.6 μm (25 μin.) for media wetted surfaces,
mechanically polished internal
1507
9 Continuation of Surface Code
Ra ≤ 0.6 µm (25 µin.) for media wetted surfaces,
electropolished internal/external
1508
Ra ≤ 0.4 µm (15 µin.) for media wetted surfaces,
in accordance with DIN 11866 H4,
mechanically polished internal
1536
Ra ≤ 0.4 µm (15 µin.) for media wetted surfaces,
in accordance with DIN 11866 HE4,
electropolished internal/external
1537
Ra ≤ 0.25 μm (10 µin.) for media wetted surfaces
*),
in accordance with DIN 11866 HE5,
electropolished internal/external,
*) for inner pipe diameters < 6 mm, in the spigot Ra
≤ 0.38 μm
1516
Ra ≤ 0.25 μm (10 µin.) for media wetted surfaces
*),
in accordance with DIN 11866 H5,
mechanically polished internal,
*) for inner pipe diameters < 6 mm, in the spigot Ra
≤ 0.38 μm
1527
Ra max. 0.51 µm (20 µin.) for media wetted sur-
faces,
in accordance with ASME BPE SF1,
mechanically polished internal
SF1
Ra max. 0.64 µm (25 µin.) for media wetted sur-
faces,
in accordance with ASME BPE SF2,
mechanically polished internal
SF2
Ra max. 0.76 µm (30 µin.) for media wetted sur-
faces,
in accordance with ASME BPE SF3,
mechanically polished internal
SF3
Ra max. 0.38 µm (15 µin.) for media wetted sur-
faces,
in accordance with ASME BPE SF4,
electropolished internal/external
SF4
Ra max. 0.51 µm (20 µin.) for media wetted sur-
faces,
in accordance with ASME BPE SF5,
electropolished internal/external
SF5
Ra max. 0.64 µm (25 µin.) for media wetted sur-
faces,
in accordance with ASME BPE SF6,
electropolished internal/external
SF6
10 Actuator version Code
Actuator size 1
diaphragm size 8
with distance piece
B1
Actuator size 1
diaphragm size 10
1C
Actuator size 1
diaphragm size 25
1F
Actuator size 3
diaphragm size 40
3H
6 Order data
www.gemu-group.com8 / 41GEMÜ 629 eSyLite

11 CONEXO Code
Without
Integrated RFID chip for electronic identification
and traceability
C
6 Order data
www.gemu-group.com 9 / 41 GEMÜ 629 eSyLite

Order example
Ordering option Code Description
1 Type 629 Diaphragm valve, motorized,
stainless steel diaphragm valve
2 DN 40 DN 40
3 Body configuration D 2/2-way body
4 Connection type 60 Spigot ISO 1127/EN 10357 series C/DIN 11866 series B
5 Valve body material 40 1.4435 (F316L), forged body
6 Diaphragm material 5M PTFE/EPDM two-piece
7 Voltage/Frequency C1 24 V DC
8 Control module A0 Open/Close control (economy)
9 Surface 1503 Ra ≤ 0.8 µm (30 µin.) for media wetted surfaces,
in accordance with DIN 11866 HE3,
electropolished internal/external
10 Actuator version 3H Actuator size 3
diaphragm size 40
11 CONEXO Without
6 Order data
www.gemu-group.com10 / 41GEMÜ 629 eSyLite

7 Technical data
7.1 Medium
Working medium: Corrosive, inert, gaseous and liquid media which have no negative impact on the physical and
chemical properties of the body and diaphragm material.
The valve will seal in both flow directions up to full operating pressure (gauge pressure).
7.2 Temperature
Media temperature: -10 — 80 °C
Ambient temperature: -10 — 50 °C
If the emergency power module is used (control module code A1, A2), the maximum ambient tem-
perature is reduced to 40 °C.
Storage temperature: 0 — 40 °C
7.3 Pressure
Operating pressure: 0 — 6 bar
Pressure rating: PN 16
Leakage rate: Leakage rate A to P11/P12 EN 12266-1
Kv values: MG DN Connection type code
0 16 17 18 37 59 60 1 31
8 4 0.5--------
6- - 1.1 - - - 1.2 - -
8- - 1.3 - - 0.6 2.2 - -
10 - 2.1 2.1 2.1 - 1.3 - - -
15 -----2.0---
10 10 - 2.4 2.4 2.4 - 2.2 3.3 - -
12 -------3.2-
15 3.3 3.8 3.8 3.8 - 2.2 4.0 3.4 -
20 -----3.8---
25 15 4.1 4.7 4.7 4.7 - - 7.4 6.5 6.5
20 6.3 7.0 7.0 7.0 - 4.4 13.2 10.0 10.0
25 13.9 15.0 15.0 15.0 12.6 12.2 16.2 14.0 14.0
40 32 25.3 27.0 27.0 27.0 26.2 - 30.0 26.0 26.0
40 29.3 30.9 30.9 30.9 30.2 29.5 32.8 33.0 33.0
MG = diaphragm size, Kv values in m³/h
Kv values determined in accordance with DIN EN 60534 standard, inlet pressure 5 bar, Δp 1 bar, stainless steel
valve body and soft elastomer diaphragm. The Kv values for other product configurations (e.g. other diaphragm
or body materials) may differ. In general, all diaphragms are subject to the influences of pressure, temperature,
the process and their tightening torques. Therefore the Kv values may exceed the tolerance limits of the stand-
ard.
The Kv value curve (Kv value dependent on valve stroke) can vary depending on the diaphragm material and dur-
ation of use.
GEMÜ 629 eSyLitewww.gemu-group.com 11 / 41
7 Technical data

Kv values: MG DN GG 25 PFA / PP Hard rubber
25 15 7.0 5.0 6.0
20 14.0 9.0 11.0
25 20.0 13.0 15.0
40 32 36.0 23.0 29.0
40 40.0 26.0 32.0
MG = diaphragm size, Kv values in m³/h
Kv values determined in accordance with EN 60534, inlet pressure 5 bar, Δp 1 bar, with connection flange EN
1092 length EN 558 series 1 and soft elastomer diaphragm. The Kv values for other product configurations (e.g.
other diaphragm or body materials) may differ. In general, all diaphragms are subject to the influences of pres-
sure, temperature, the process and their tightening torques. Therefore the Kv values may exceed the tolerance
limits of the standard.
The Kv value curve (Kv value dependent on valve stroke) can vary depending on the diaphragm material and dur-
ation of use.
www.gemu-group.com12 / 41GEMÜ 629 eSyLite
7 Technical data

7.4 Product compliance
Pressure Equipment Dir-
ective:
2014/68/EU
Machinery Directive: 2006/42/EC
EMC Directive: 2014/30/EU
Technical standards used:
Interference emission: DIN EN 61800-3
Interference resistance: DIN EN 61326-1 (industrial processes)
DIN EN 61800-3
Food: Regulation (EC) No. 1935/2004*
Regulation (EC) No. 10/2011*
FDA*
USP* Class VI
* depending on version and/or operating parameters
7.5 Mechanical data
Protection class: IP 65 acc. to EN 60529
Actuating speed: Max. 3 mm/s
Flow direction: Optional
Installation position: Optional
Observe the angle of rotation to achieve an installation for optimized draining
Weight: Actuator
Actuator version B1 1.0 kg
Actuator version 1C 0.8 kg
Actuator version 1F 0.94 kg
Actuator version 3H 1.4 kg
GEMÜ 629 eSyLitewww.gemu-group.com 13 / 41
7 Technical data

Weight: Body
Connection types code 0, 16, 17,
18, 35, 36,
37, 55, 59,
60, 63, 64,
65
1 31 6, 6K 8, 38, 39,
51, 56
80, 82, 88,
8A , 8E, 8P,
8T
Valve body Spigot Threaded
socket
Threaded
socket
Threaded
spigot
Flange Clamp
MG DN
8 4 0.09 - - - - -
60.09 - - - - -
80.09 - - - - 0.15
10 0.09 - - 0.21 - 0.18
15 0.09 - - - - 0.18
10 10 0.30 - - 0.33 - 0.30
12 ------
15 0.30 - - 0.35 - 0.43
20 0.30 - - - - 0.43
25 15 0.62 0.50 0.32 0.71 1.85 0.75
20 0.58 0.60 0.34 0.78 2.35 0.71
25 0.55 0.90 0.39 0.79 2.85 0.63
40 32 1.45 1.20 0.88 1.66 4.90 1.62
40 1.32 1.80 0.93 1.62 5.65 1.50
MG = diaphragm size, weight in kg
www.gemu-group.com14 / 41GEMÜ 629 eSyLite
7 Technical data

7.6 Duty cycle and service life
Service life: Class A acc. to EN 15714-2
Minimum 100,000 switching cycles at room temperature and permissible duty cycle.
Duty cycle: max. 30% duty
7.7 Electrical data
Supply voltage: 24 V DC
Tolerance ± 10 %
Operating time: Diaphragm size 8: 1.8 s
MG 10: 2.5 s
MG 25: 4.0 s
MG 40: 4.5 s
Close tight current / rated
current:
Diaphragm size 8: 0.5 A
MG 10: 0.5 A
MG 25: 1.3 A
MG 40: 2.3 A
Starting current / max-
imum current:
Diaphragm size 8: approx. 2.4 A
MG 10: approx. 2.4 A
MG 25: approx. 2.4 A
MG 40: approx. 4.5 A
Standby current con-
sumption:
approx. 10 mA
7.7.1 Digital input signals
Input voltage: max. 30 V DC
High level: ≥ 18 V DC
Low level: ≤ 5 V DC
7.7.2 Emergency power supply module
Charging current: MG 8, MG 10, MG 25: max. 0.16 A
MG 40: 0.32 A
Charging time: approx. 13 min
Service life: Guide value at 25 °C ambient temperature, approx. 3 years
GEMÜ 629 eSyLitewww.gemu-group.com 15 / 41
7 Technical data

8 Dimensions
8.1 Actuator dimensions without position indicator
B1
B3
B2
A
CT*
A1
B
MG A A1 B B1 B2 B3
8211.0 82.0 59.5 134.5 115.0 82.0
10 192.0 63.0 59.5 134.5 115.0 82.0
25 204.0 75.0 59.5 134.5 115.0 82.0
40 228.0 91.0 80.0 167.0 147.5 94.5
Dimensions in mm
MG = diaphragm size
* CT = A + H1 (see body dimensions)
www.gemu-group.com16 / 41GEMÜ 629 eSyLite
8 Dimensions

8.2 Actuator dimensions with GEMÜ 1215 position indicator
A
BZ2
AZ1
AZ2
BZ1
MG A AZ1 AZ2 BZ1 BZ2
8 256.0 72.0 61.0 30.0 40.0
10 237.0 72.0 61.0 30.0 40.0
25 249.0 72.0 61.0 30.0 40.0
40 273.0 72.0 61.0 30.0 40.0
Dimensions in mm
MG = diaphragm size
GEMÜ 629 eSyLitewww.gemu-group.com 17 / 41
8 Dimensions

8.3 Body dimensions
8.3.1 Spigot DIN/EN ISO (code 0, 16, 17, 18, 60)
L
c
ød
s
H1
Connection type spigot DIN/EN/ISO (code 0, 16, 17, 18, 60) 1), forged material (code 40, 42, F4) 2)
MG DN NPS c (min) ød H1 L s
Connection type Connection type
0 16 17 18 60 0 16 17 18 60
8 4 - 20.0 6.0 - - - - 8.5 72.0 1.0 - - - -
6 - 20.0 - - 8.0 - 10.2 8.5 72.0 - - 1.0 - 1.6
8 1/4" 20.0 - - 10.0 - 13.5 8.5 72.0 - - 1.0 - 1.6
10 3/8" 20.0 - 12.0 13.0 14.0 - 8.5 72.0 - 1.0 1.5 2.0 -
10 10 3/8" 25.0 - 12.0 13.0 14.0 17.2 12.5 108.0 - 1.0 1.5 2.0 1.6
15 1/2" 25.0 18.0 18.0 19.0 20.0 21.3 12.5 108.0 1.5 1.0 1.5 2.0 1.6
25 15 1/2" 25.0 18.0 18.0 19.0 20.0 21.3 19.0 120.0 1.5 1.0 1.5 2.0 1.6
20 3/4" 25.0 22.0 22.0 23.0 24.0 26.9 19.0 120.0 1.5 1.0 1.5 2.0 1.6
25 1" 25.0 28.0 28.0 29.0 30.0 33.7 19.0 120.0 1.5 1.0 1.5 2.0 2.0
40 32 1¼" 25.0 34.0 34.0 35.0 36.0 42.4 26.0 153.0 1.5 1.0 1.5 2.0 2.0
40 1½" 25.0 40.0 40.0 41.0 42.0 48.3 26.0 153.0 1.5 1.0 1.5 2.0 2.0
Dimensions in mm
MG = diaphragm size
1) Connection type
Code 0: Spigot DIN
Code 16: Spigot EN 10357 series B, formerly DIN 11850 series 1
Code 17: Spigot EN 10357 series A (formerly DIN 11850 series 2)/DIN 11866 series A
Code 18: Spigot DIN 11850 series 3
Code 60: Spigot ISO 1127/EN 10357 series C/DIN 11866 series B
2) Valve body material
Code 40: 1.4435 (F316L), forged body
Code 42: 1.4435 (BN2), forged body, Δ Fe < 0.5 %
Code F4: 1.4539, forged body
www.gemu-group.com18 / 41GEMÜ 629 eSyLite
8 Dimensions

L
c
ød
s
H1
Connection type spigot DIN/EN/ISO (code 0, 17, 60) 1), investment casting material (code C3) 2)
MG DN NPS c (min) ød H1 L s
Connection type Connection type
0 17 60 0 17 60
8 4 - 20.0 6.0 - - 8.5 72.0 1.0 - -
6 - 20.0 - 8.0 - 8.5 72.0 - 1.0 -
8 1/4" 20.0 - 10.0 13.5 8.5 72.0 - 1.0 1.6
10 3/8" 20.0 - 13.0 - 8.5 72.0 - 1.5 -
10 10 3/8" 25.0 - 13.0 17.2 12.5 108.0 - 1.5 1.6
15 1/2" 25.0 - 19.0 21.3 12.5 108.0 - 1.5 1.6
25 15 1/2" 25.0 - 19.0 21.3 13.0 120.0 - 1.5 1.6
20 3/4" 25.0 - 23.0 26.9 16.0 120.0 - 1.5 1.6
25 1" 25.0 - 29.0 33.7 19.0 120.0 - 1.5 2.0
40 32 1¼" 25.0 - 35.0 42.4 24.0 153.0 - 1.5 2.0
40 1½" 25.0 - 41.0 48.3 26.0 153.0 - 1.5 2.0
Dimensions in mm
MG = diaphragm size
1) Connection type
Code 0: Spigot DIN
Code 17: Spigot EN 10357 series A (formerly DIN 11850 series 2)/DIN 11866 series A
Code 60: Spigot ISO 1127/EN 10357 series C/DIN 11866 series B
2) Valve body material
Code C3: 1.4435, investment casting
GEMÜ 629 eSyLitewww.gemu-group.com 19 / 41
8 Dimensions

8.3.2 Spigot ASME/BS (code 55, 59, 63, 65)
L
c
ød
s
H1
Connection type spigot ASME/BS (code 55, 59, 63, 64, 65) 1), forged material (code 40, 42, F4) 2)
MG DN NPS c (min) ød H1 L s
Connection type Connection type
55 59 63 64 65 55 59 63 64 65
8 6 - 20.0 - - 10.3 - 10.3 8.5 72.0 - - 1.24 - 1.73
8 1/4" 20.0 6.35 6.35 13.7 - 13.7 8.5 72.0 1.2 0.89 1.65 - 2.24
10 3/8" 20.0 9.53 9.53 - - - 8.5 72.0 1.2 0.89 - - -
15 1/2" 20.0 12.70 12.70 - - - 8.5 72.0 1.2 1.65 - - -
10 10 3/8" 25.0 9.53 9.53 17.1 - 17.1 12.5 108.0 1.2 0.89 1.65 - 2.31
15 1/2" 25.0 12.70 12.70 21.3 21.3 21.3 12.5 108.0 1.2 1.65 2.11 1.65 2.77
20 3/4" 25.0 19.05 19.05 - - - 12.5 108.0 1.2 1.65 - - -
25 15 1/2" 25.0 - - 21.3 21.3 21.3 19.0 120.0 - - 2.11 1.65 2.77
20 3/4" 25.0 19.05 19.05 26.7 26.7 26.7 19.0 120.0 1.2 1.65 2.11 1.65 2.87
25 1" 25.0 - 25.40 33.4 33.4 33.4 19.0 120.0 - 1.65 2.77 1.65 3.38
40 32 1¼" 25.0 - - 42.2 42.2 42.2 26.0 153.0 - - 2.77 1.65 3.56
40 1½" 25.0 - 38.10 48.3 48.3 48.3 26.0 153.0 - 1.65 2.77 1.65 3.68
Connection type spigot ASME BPE (code 59) 1), investment casting material (code C3) 2)
MG DN NPS c (min) ød H1 L s
8 8 1/4" 20.0 6.35 8.5 72.0 0.89
10 3/8" 20.0 9.53 8.5 72.0 0.89
15 1/2" 20.0 12.70 8.5 72.0 1.65
10 20 3/4" 25.0 19.05 12.5 108.0 1.65
25 20 3/4" 25.0 19.05 16.0 120.0 1.65
25 1" 25.0 25.40 19.0 120.0 1.65
40 32 1¼" 25.0 - - 153.0 -
40 1½" 25.0 38.10 26.0 153.0 1.65
Dimensions in mm
MG = diaphragm size
1) Connection type
Code 55: Spigot BS 4825, part 1
Code 59: Spigot ASME BPE / DIN 11866 series C
Code 63: Spigot ANSI/ASME B36.19M schedule 10s
Code 64: Spigot ANSI/ASME B36.19M schedule 5s
Code 65: Spigot ANSI/ASME B36.19M schedule 40s
2) Valve body material
Code 40: 1.4435 (F316L), forged body
Code 42: 1.4435 (BN2), forged body, Δ Fe < 0.5 %
Code C3: 1.4435, investment casting
Code F4: 1.4539, forged body
www.gemu-group.com20 / 41GEMÜ 629 eSyLite
8 Dimensions
Other manuals for eSyLite 629
1
This manual suits for next models
1
Table of contents
Other GEM Control Unit manuals
Popular Control Unit manuals by other brands

ACS
ACS ACM1281U-C7 Reference manual

schmersal
schmersal SRB 211LT/CC operating instructions

Total Control
Total Control QPI-PSL-201 installation guide

Pfeiffer Vacuum
Pfeiffer Vacuum RME 005 A operating instructions

RICOMAN
RICOMAN Gemini installation instructions

Conductrix Wampfler
Conductrix Wampfler 0832 installation instructions