ELIMOS RiTa EasyGo User manual

ELIMOS S.r.l.
Sede legale: via Galvani, 5c - 34133 Trieste - Italy
Sede operativa: AREA Science Park - Padriciano 99 - 34149 Trieste - Italy
Tel/Fax: +39-040 375 5356 - E-mail: info@elimos.it - Http: www.elimos.it
P.IVA - C.F. - R.I. Trieste: 01098690322 - Cap.soc.: Euro 50.000,00 i.v.
R
Ri
iT
Ta
a
L
LI
IC
CE
EN
NS
SE
E
P
PL
LA
AT
TE
E
R
RE
EA
AD
DE
ER
R
QUICK INSTALLATION GUIDE
Date 21 Jun 2013
Version 1.1
File RiTa EasyGo - Quick Installation Guide V 1.0 - ENG

QUICK INSTALLATION GUIDE
RiTa EasyGo–LPR System
Technical Documentation –All Rights Reserved
2
PRODUCTS IMPORTANT INFORMATION
CE Compliances
The manufacturer hereby declares that the RiTa System HW components are compliant with CE Directive
specifies in EMC 89/336/EEC.
The products are compliant with following regulations:
- Emission: EN55022, EN55024
- Immunity: EN61000-4-4, -3, -4, -5, -8, -11
Products modification
All products must be installed and used in accordance with the instructions supplied with present
documentation.
All products does not have user replaceable parts.
Any changes or replacement of parts made to the products will void the warranty.
Correct disposal of the products
(Electric and Electronic garbage)
(Apply in EU Countries and other countries with separate collection systems)
This marking shown on the product or its literature, indicates that this product must not be
disposed of with other household waste at the end of its life.
To prevent possible harm to the environment or human health from uncontrolled waste
disposal, the user is encouraged to separate this from other types of wastes and recycle it
responsibly to promote the sustainable reuse of material resources
Household users should contact either the retailer where they purchased this product, or
their local government office, for details on separate collection and recycling for this type
of product.
Business users should contact their supplier and check the terms and conditions of the purchase contract.
This product should not be mixed with other commercial wastes for disposal.
Note: Technical specifications and information are subject to change without prior notice

QUICK INSTALLATION GUIDE
RiTa EasyGo–LPR System
Technical Documentation –All Rights Reserved
3
Summary
1Hardware Overview –EasyGo Control Unit........................................................................................ 4
1.1 LPR Camera –EpCAM.......................................................................................................................................... 6
1.1.1 Install the EpCAM camera .......................................................................................................................... 7
1.1.2 Power Specifications.................................................................................................................................... 7
1.1.3 Environmental conditions.............................................................................................................................. 7
1.1.4 EpCAM connection cables........................................................................................................................... 8
1.1.5 Power and I/O connections........................................................................................................................ 8
1.1.6 I/O connections ............................................................................................................................................. 8
2Camera positioning ............................................................................................................................. 9
3Cabling EasyGo 1 lane system.......................................................................................................... 10
4Default IP Addressing........................................................................................................................ 11

QUICK INSTALLATION GUIDE
RiTa EasyGo–LPR System
Technical Documentation –All Rights Reserved
4
1Hardware Overview –EasyGo Control Unit
Front View
1. Ventilator: The ventilator on the enclosure is used for
air convection and to prevent the equipment from
overheating. Do not cover the ventilator.
2. Card Reader Drive
3. Power Button/ LED: Press the power button to turn the
system on and off. The power LED glows when the
system is turned on and goes off when the system is
shut down.
4. USB 2.0 Port: The USB (Universal Serial Bus) port is for
attaching USB devices such as keyboard, mouse, or
other USB-compatible devices.
5. Headphone Jack: This is a connector for headphones.
6. Microphone Jack: This is a connector for microphones.
7. WLAN LED
8. HDD LED: It flashes when the system is accessing data
on the HDD and remains off when no disk activity is
detected.
9. Stand: Use this stand to position your system on a flat
and stable surface. Another way to position your
system without stand is to lay your system horizontally on the surface with the Power Button faces up to
the top.
Rear View
1. Card Reader Drive
2. Power Button/ LED: Press the power button to turn the
system on and off . The power LED glows when the
system is turned on and goes off when the system is
shut down.
3. Ventilator: The ventilator on the enclosure is used for
air convection and to prevent the equipment from
overheating. Do not cover the ventilator.
4. VGA-Out Port: The DB15-pin female connector is
provided for monitor.
5. HDMI-Out Port: HDMI supports all TV format, including
standard, enhanced or high-definition video, plus
multi-channel digital audio on a single cable.
6. USB 2.0 Port: The USB (Universal Serial Bus) port is for
attaching USB devices such as keyboard, mouse, or
other USB-compatible devices.
7. RJ-45 LAN Jack: The standard RJ-45 LAN jack is
provided for connection to the Local Area Network
(LAN). You can connect a network cable to it.
8. Speaker Jack: This is a connector for speakers.
9. Optical S/PDIF-Out Jack
10. Power Jack: The AC/DC adapter converts AC power to DC power for this jack. Power supplied through
this jack supplies power to your personal computer. To prevent damage to the PC, always use the
supplied power adapter.
11. Stand: Use this stand to position your system on a flat and stable surface. Another way to position your
system without stand is to lay your system horizontally on the surface with the Power Button faces up to
the top.

QUICK INSTALLATION GUIDE
RiTa EasyGo–LPR System
Technical Documentation –All Rights Reserved
5
RJ45 LAN Jack
LED
Color
LED State
Condition
Right
Yellow
Off
LAN link is not established
On (steady state)
LAN link is established
On (brighter & pulsing)
The computer is communicating with another computer on the LAN
Left
Green
Off
10 Mbit/sec data rate is selected
On
100 Mbit/sec data rate is selected
Orange
On
1000 Mbit/sec data rate is selected
Main Features:
•Powerful OCR Engine for all European Country plates and complete all-in-one RiTa SW suite in EasyGo
version.
•High performance and low power (less than 40W)
•One lane access control system with “on-fly” plate reading (no HW trigger needed)
•High speed reading rate (up to 4 read/sec.)
•Windows 7 Embedded™Operating System
•Simplified installation: plug-and-play –no configuration needed, motorized barrier command directly
from camera
•Camera with synchronized IR illuminator: h24 365/365 functioning
Specifications
Power Supply
40 watt AC/DC adapter with active PFC
Input: 100-240V~, 50-60Hz, 1.2A –Output: 19V 2.1A
Dimensions
186 mm (W) x 222 mm (H) x 76 mm (D) (with stand)
150 mm (W) x 191 mm (H) x 36 mm (D) (without stand)
Certifications
CE approval

QUICK INSTALLATION GUIDE
RiTa EasyGo–LPR System
Technical Documentation –All Rights Reserved
6
1.1 LPR Camera –EpCAM
Sunshield
Green status LED
Wall bracket
Infrared LEDs
Camera optics
Infrared LEDs
Camera with bracket
Bracket
Red status LED
Light sensor
Camera front

QUICK INSTALLATION GUIDE
RiTa EasyGo–LPR System
Technical Documentation –All Rights Reserved
7
1.1.1 Install the EpCAM camera
The bracket can be adjusted in two different points.
Firstly, the bracket allows rotating the ball joint in a 35 degree spatial angle in any direction. Secondly, by
rotating the foot of the bracket, this angle can be extended with additional 20° according to the figure.
Steps of rotating the foot
1. Remove the four screws (a) located at
the back of the foot. (Use size 4 Allen
key).
2. Rotate the foot (b) by 180 degrees.
3. Place the screws back into the holes
and screw them back on.
NOTE: Do not over tighten the screws.
Attention: Use appropriate screws for
installation according to the
mountable surface.
Damage to the product caused
during installation may void
the warranty.
1.1.2 Power Specifications
The camera may be powered at 12VDC.
Please consider voltage drop on long cable lengths.
Input voltage: 12VDC [nominal] (min.10V –max 15V) reverse polarity protected
Power: 10W
Current: 1A (max 2,5A transients occur for a few µsec) –Over-current protection by fuse
Note:Connect the camera to the TCP/IP network before power on.
1.1.3 Environmental conditions
Maintain always clean the camera.
During cleaning operations please avoid the formation of scratches or other damages on the lens.
Do not use camera without the sunshield.
The minimal startup temperature of the camera is –20°C.
(a)
(a)
(a)
(a)
(b)

QUICK INSTALLATION GUIDE
RiTa EasyGo–LPR System
Technical Documentation –All Rights Reserved
8
1.1.4 EpCAM connection cables
The camera is equipped with two cables. The first cable is responsible for the power, trigger and serial
connections while the second cable is for communication via TCP/IP.
Attention: For cabling, use quality, outdoor-certified cables.
Improper or wrong cabling cause warranty to void.
The camera is not waterproof!
Protect the cables from the water to prevent damage to the camera!
Failure to comply with these rules may result in a failure of the camera and this could
be irreparably damaged.
1.1.5 Power and I/O connections
Description Color
1. DC in –Black
2. DC in + Red
3. Opto in + Brown
4. Opto out –Red
5. Opto out + Grey
6. Opto in –Orange
7. Serial TX White
8. Serial RX Green
9. NC (no connect) Yellow
10. Serial GND Blue
Attention: Take care to avoid accidental contact between the wires in the wiring. This cause
permanent damage to the product and void the warranty.
Use smooth circular cables only, 6-8mm in diameter.
The RJ45 connector for network connection is not waterproof!
Seal the unused cable endings (end sleeves) before connecting to power in order to
avoid damages due to short circuit!
1.1.6 I/O connections
Schematics for triggering and I/O connections:
Output: Open collector (max 12VDC / 10mA)
Input: min. 5V –max. 12V
Pulse width: min. 10ms

QUICK INSTALLATION GUIDE
RiTa EasyGo–LPR System
Technical Documentation –All Rights Reserved
9
2Camera positioning
The powerful ANPR engine of RiTa Systems can read the plates from images taken in various conditions.
However if you want to achieve the best recognition rate with short recognition times, you have to calculate
the position of the camera accurately.
The best position is if the angle between the camera axis and the direction of the vehicle movement is
minimal (see below).
The distance between the camera and plate is also important. If the camera is too far from the plate, the
characters may not be large enough for recognizing them. In this case, zoom-in until you reach the proper size.
If the distance is too short it may happen that a part of the plate is over the camera’s field of view (when the
vehicle is near to the side of the lane or the plate is not at the middle of the vehicle).
Following picture shows the suggested layout for the installation of RiTa EasyGo system:
From the point of ANPR/LPR the most important is the size of the
characters on the image. For Latin characters it is recommended to
have at least 16 pixel average character height, for Arabic or other
special characters it is recommended to have 20 pixel height (due to
they are more calligraphic than the Latin characters).
The too large characters are also not suitable for ANPR, therefore
try to avoid settings where the character size is greater than 50
pixels in height. A line width of a character on the image should be
at least 2-3 pixels.

QUICK INSTALLATION GUIDE
RiTa EasyGo–LPR System
Technical Documentation –All Rights Reserved
10
3Cabling EasyGo 1 lane system
Ethernet network
EasyGo ONE Lane RiTa System
EpCAM or FreeCAM
Optional Overview
Surveillance Camera
EasyGo 1 Lane
Control Unit
Remote Operator Console
(Optional - up to 1)
Optional I/O module
To motorized barrier
To motorized
barrier
1 Lane Control Unit
connection details
POWER
IP NETWORK
KEYBOARD
MOUSE
MONITOR HD1080
Local Operator
Console

QUICK INSTALLATION GUIDE
RiTa EasyGo–LPR System
Technical Documentation –All Rights Reserved
11
4Default IP Addressing
The installation default IP addressing is configured as follows:
Device
IP Address
Notes
Control Unit
192.168.125.100
LAN Port 1
LPR Camera 1
192.168.125.101
Surveillance Camera 1
192.168.125.111
Optional
I/O module (EpCore)
192.168.125.120
Optional
Notes:

QUICK INSTALLATION GUIDE
RiTa EasyGo–LPR System
Technical Documentation –All Rights Reserved
12
Notes:
ELIMOS S.r.l.
AREA Science Park –Padriciano 99
34149 Trieste
Tel/Fax: +39 040 3755356
Sales Office
Tel/ Fax: +39 0523 498236
E-mail: [email protected]
http://www.elimos.it
Table of contents
Popular Control Unit manuals by other brands

Vantage Hearth
Vantage Hearth LVOS-0-10-PWM-1 Installation

DEEP SEA ELECTRONICS
DEEP SEA ELECTRONICS 6110 How to perform

P.A.
P.A. VRP200 Technical manual

Atlantic
Atlantic PRIMOCOSY HR BP Fitting instructions

GEA
GEA Aseptomag AV Translation from the Original Operating Manual

Fluke
Fluke DSP-PM11B instruction sheet