manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Elitech
  6. •
  7. Touch Panel
  8. •
  9. Elitech TI-40 User manual

Elitech TI-40 User manual

Overview
The temperature indicator is mainly used in the fields of pharmaceuticals, vaccine,
blood, food, flowers and plants, laboratories, etc. especially for the places that
require using temperature indicator of high waterproof grade in cold chain storage
and transportation.
About the indicator
Parameter conguration
1
2
3
4
Double-faced adhensive
tape on the back
LCD screen
Start & stop botton
Bar coade & serial No.
1) Before delivery, the indicator’s parameters are configured.
Just press START button to start it for use.
2) Default configuration:
Operation instruction
1. Press (START) botton for about five seconds, " " will be on, The indicator
successfully starting.
2. If there is start delay, short press the button, " " will flash 30 seconds to off;
if no start delay, then " " will be on for 30 seconds to off.
3. When the LCD temperature indicator is on, if the current status is start delay,
you can not stop the indicator by stop (STOP) buttun. After start delay time,
press the STOP button for about 5 seconds, the " " icon on the LCD screen
will be off, " " lights up, it means that the LCD temperature indicator has
stopped.when the LCD temperature indicator is stopped, it will not be possible
to turn on the indicator by pressing the start (START) button.
4. short press the button to view the LCD temperature indicator's information, such as
the maximum & minimum temperature, average teprature, alarm information, etc.
Working instruction
1. Not started state: the triangle in LCD screen is not displayed, see Figure 1
2.Start delay status: the triangle in LCD screen flashes for 30 seconds and goes off, see Fig. 2
Fig 1 LCD indicator not started
Fig 2 LCD indicator start delay
Start delay: 10min
Log interval: 5min
Temp H2 (high): 45℃
Alarm type: cum (cumulative)
Alarm delay: 60min
Temp H1 (high): 30℃
Alarm type: cum (cumulative)
Alarm delay: 10h
Temp L1 (low): -0.5℃
Alarm type: sin (single)
Alarm delay: 60min
Temp L2 (low): -5℃
Alarm type: sin (single)
Alarm delay: 60min
1
2
3
4
Technical parameters
Temperature measuring range : -30℃ ~ 70℃
Storage range : -25℃ ~ 60℃
Temperature accuracy : -20℃~+ 40℃±0.5℃, other±1℃
Sensor : Internal NTC
Log interval : 5minutes (default)
Start delay : 1min~12hr,default setting (one min as step unit)
Power suply : internal CR2450 lithium battery
Bettery life : 2 yr at 25℃ with log interval 5 min
Protection grade : IP67
Dimensions : 77mm*46mm*12 mm(L*W*H)
Weight : about 40g
Start : press the botton for over 5 seconds
Stop : press the botton for over 5 seconds
It is recommended to store at room temperature before the temperature label is not activated.
In order to ensure the waterproof level of the indicator, please do not steep the indicator in alcohol
or oleic acid and other corrosive liquids for long time.
User Manual TI-40 LCD Temperature Indicator
3. Working status (no alarm): the triangle in LCD screen stays on for 30 seconds and goes off
4. Working status (alarm): LCD screen shows the wrong number and the corresponding
temperature segment, the screen will be off after 30 seconds.
Fig 3 LCD indicator Working status (no alarm)
Fig 4 LCD indicator working status (alarm)
YY:MM:DD HH:MM:SS
LCD display interfaceStatus interface
Max, Min, Average
System time
Temperature range configuration
H2 Alarm threshold 45.0 degree, alarm type single (Sin), alarm delay 1 hour.
H1 Alarm threshold 30.0 degree, alarm type cumulative (cum), alarm delay 10 hours.
HH:MM:SS
YY:MM:DD
L2 Alarm threshold -0.5 degree, alarm type Single (Sin), alarm delay 1 hour.
L1 Alarm threshold -0.5 degree, alarm type Single (Sin), alarm delay 1 hour.
Start time: 10 hours 9 minutes.
Temperature range alarm cumulative time
H2 temperature range alarm cumulative time 1 hour and 8 minutes Initial
alarm time
H2 initial alrm time 12 Jan., 2017, 19:35:08
Serial No. Stop status (no alarm)
The last five number of serial No. 00018
User Manual TI-40 LCD Temperature Indicator
V2.0
Elitech Technology, lnc.
www.elitechlog.com
1551 McCarthy Blvd, Suite 112
Milpitas, CA 95035 USA

Popular Touch Panel manuals by other brands

Protech Systems SP-6555 Quick reference guide

Protech Systems

Protech Systems SP-6555 Quick reference guide

Protech Systems PPC-1208F Quick reference guide

Protech Systems

Protech Systems PPC-1208F Quick reference guide

Aplex ViTAM-6 Series user manual

Aplex

Aplex ViTAM-6 Series user manual

Acnodes PANEL PC 1000 installation guide

Acnodes

Acnodes PANEL PC 1000 installation guide

Qomo Journey 13 user manual

Qomo

Qomo Journey 13 user manual

Axis 2N Indoor Touch 2.0 user guide

Axis

Axis 2N Indoor Touch 2.0 user guide

Winmate W05TA3S-PCT3AC quick start guide

Winmate

Winmate W05TA3S-PCT3AC quick start guide

Topaz TPZ-TS-32 Hardware user manual

Topaz

Topaz TPZ-TS-32 Hardware user manual

turbofan MOFFAT BLUE SEAL 30D Series Installation and operation manual

turbofan

turbofan MOFFAT BLUE SEAL 30D Series Installation and operation manual

DoorBird Divus manual

DoorBird

DoorBird Divus manual

Kingdy DP-2L Series user manual

Kingdy

Kingdy DP-2L Series user manual

Toshiba RBC-TBPTs installation manual

Toshiba

Toshiba RBC-TBPTs installation manual

Joy-it RB-LCD7.2 manual

Joy-it

Joy-it RB-LCD7.2 manual

Dover TWG GC MicroGuard 586 Operation Setup Maintenance

Dover

Dover TWG GC MicroGuard 586 Operation Setup Maintenance

syslogic TFT/HB PU8 Series User documentation

syslogic

syslogic TFT/HB PU8 Series User documentation

BeiJer H-T40m Series Installation and operation manual

BeiJer

BeiJer H-T40m Series Installation and operation manual

Onyx ONYX-122 manual

Onyx

Onyx ONYX-122 manual

Q-NEX CPL10 user manual

Q-NEX

Q-NEX CPL10 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.