Elmes Electronic CB32G User manual

- 1 -
Wireless Alarm Control Panel CB32G
(ver. 1.40, 09.2018)
Installation and operation manual
INTRODUCTION.....................................................................................................2
KEYPAD USE AND ARMING METHODS.............................................................3
ARMING &DISARMING OF ALARM SYSTEM. 4
1. Arming & disarming alarm from CB32G panel keypad. 4
2. Operating CB32G control panel using a remote (hand transmitter). 4
3. Arming & disarming using a mobile phone. 5
4. Arming the system bypassing selected alarm zones. 5
CB32G SELECTED FUNCTIONS DESCRIPTION................................................5
WIRELESS DETECTOR STATE MONITOR 5
SABOTAGE PROTECTION OF EXTERNAL DEVICES 5
OPERATION WITH WIRED ALARM DETECTORS 5
OPERATION WITH REMOTE CONTROL TRANSMITTER (REMOTE) 6
OPERATION WITH EXTERNAL WIRELESS SIREN 6
GSM MODULE FEATURES 6
CB32G PANEL CONFIGURATION AND FIRMWARE UPGRADE USING PC 7
MAIN MENU ............................................................................................................7
ALARMS MEMORY 7
FAILURES 7
SYSTEM STATUS 7
SERVICE SETTINGS (S.S.) 7
1. Event Memory 8
2. Password Change 8
3. Alarm Zones 8
4. Outputs settings 10
5. System users - adding, editing and removing a user 11
6. System times 13
7. Alarm notification by GSM module 13
8. Auxiliary functions settings. 15
9. Signalling modes of system arming. 17
SETTINGS RESET.................................................................................................17
RESETTING PASSWORD OF USER NUMBER 1. 17
CB32G RESTORE TO FACTORY SETTINGS (DEFAULT SETTINGS). 18
DESIGNING WIRELESS ALARM SYSTEM.......................................................18
POWERING CB32G CONTROLPANEL 19
ALARM SYSTEM WITH ELMES CB32G CONTROL PANEL 19
SPECIFICATION ...................................................................................................22
MANUFACTURER’S LIMITED WARRANTY....................................................23
FREQUENTLY ASKED QUESTIONS..................................................................24

- 2 -
INTRODUCTION
Elmes Electronic CB32G is a programmable, wireless alarm control panel with integrated mo-
bile phone module, designed for use in anti-robbery, intrusion detection and access control in-
stallations. It operates with any Elmes Electronic made wireless detectors, RP501 transmitter-
receiver set, remote control transmitters and two wired detectors. Its three 1A current rated
fused alarm signalling outputs are designed for connecting external signalling devices such as
sirens, bells strobes and automatic alarm notification devices. The panel features a real-time
clock, non-editable memory log of last 256 events and may be programmed to be remotely
armed and disarmed by SMS and CLIP as well as send SMS alarm, status, failure and event
notifications. Backlit LCD panel displays appropriate status information while numeric keypad
allows convenient programming of the control panel. In the event of AC power failure, dedi-
cated software procedures initiate low energy consumption mode allowing over 24-hour panel
autonomy operation with two internal 600-850mAh Li-ION rechargeable batteries (type 14500
–AA size). The panel supports up to 16 system users and enables monitoring of up to 32
wireless and two parametric wired detectors identified as alarm zones. Each user and alarm
zone can have any user defined 16 characters name.
The CB32G control panel may be connected to and powered from any wired alarm system
with its alarm outputs connected to wired control panel.
General features of CB32G control panel:
-integrated mobile phone GSM module for arming, disarming and event notification,
- 32 wireless and two wired parametric alarm zones with user defined names,
- identification of 16 users including 4 administrators with defining their names,
- arming and disarming of the panel by keypad password (3 to 6 digits), by the use of remote
control transmitter, or by SMS and CLIP.
- range of alarm zone types for specialized operating purposes,
- functional modes of partial arming of the control panel (day, night modes),
- panic and robbery alarm function (call for help) activated by a remote,
- memory of the last 256 events, such as arming, disarming, alarms and power failures,
- acoustic signalling (beeps) of entry in a “chime type” zone,
- entry delay activated either by remote control, entering delayed zone or mobile phone,
- programmable “entry” and “exit” delay times in the range from 0 to 99 seconds,
- wireless detector and external wireless siren presence monitoring,
- three wired alarm outputs rated max. 1A with fused overload protection, programmable tim-
ing (0-999s), and user defined signalling mode (e.g. alarm, power failure, sys. arming),
- tamper sabotage protection for external signalling device wired to OUT1,
- radio jamming sabotage protection notification in zone 30,
- parametric (1 kOhm) input for TAMPER sabotage protection of external devices,
- RF signal and interference level monitor in operated radio band,
- 92dB internal acoustic siren built-in under the keypad,
- AC powering by external AC/DC unregulated power pack with 10-20VDC/1200mA output,
- over 24 hours autonomy operation on AC power failure with two 3,7V Li-ION rechargeable
batteries type 14500 and 600-850mAh capacity each,
- easy configuration programming and firmware upgrade with the use of personal computer.
FIRST USE OF CB32G CONTROL PANEL
If the control panel integral GSM module will be used, then an active SIM card will be needed.
The card should have SMS memory and address book cleared with voice mail box set off. The
SIM card may have PIN code protection set on or off. If the PIN code is on then it should have
the PIN set to 1234. This can be done using any other mobile phone. The use of SIM card

- 3 -
with other than 1234 PIN code in the CB32G control panel may cause the card to be
blocked!
In addition, two 3,7V Li-ION RECHARGABLE batteries (type 14500, AA size) with minimal
capacity of 600 mAh and AC/DC power supply pack with 10...20VDC - 1200mA (1.2A) output
should be prepared. The control panel may also be powered using external buffered power
supply (UPS) which will provide longer autonomy operation of the panel on AC power failure.
In that case, the use of internal Li-ION batteries is not required.
The following steps should be followed at first setting on the control panel:
- Remove back side of the panel cabinet.
- If GSM module is to be used, insert prepared SIM card to card socket, observing that
the cut corner of the card is in the left upper corner of the socket. The SIM card may al-
so be inserted anytime providing control panel power supply is set off.
- Connect power pack wires (plain without plug) to the control panel power supply con-
nectors observing marked polarity.
- If needed, insert the Li-ION batteries to the CB32G battery compartments carefully ob-
serving polarity marked inside.
WARNING! Correct battery polarity must be absolutely observed when inserting Li-ION batter-
ies. Incorrect battery placement may cause panel damage.
- Plug in AC/DC power pack to mains outlet socket. The control panel will initialize readi-
ness to operate displaying software version and initial time and date.
- Go to menu “Service Settings” (factory password: 0000) of the Main Menu and set up
required options to configure designed alarm system.
NOTE! The GSM module operation is factory set to OFF. To set its operation ON go to option
7.8 of the Service Settings and change the option.
Connecting to GSM network will be indicated by fast flashing blue LED. Slow flashing with 2-3
seconds intervals indicates that the module is logged to the network. In menu “System Users”
of “Service Settings” user/s phone number/s can be input and operating mode with control
panel defined. Remaining module settings can be made in option 7 and 9 of Service Settings.
ADVICE! First operation and initial settings of CB32G control panel should be made on any
workshop place prior to its firm installation. Final place of the panel installation should be care-
fully selected to allow its central positioning with regard to installed wireless detectors and to
allow optimal GSM network reception. Wireless detector’s operating range can be checked in
section 3.5 while GSM network reception in section Status of the Service Settings menu.
KEYPAD USE AND ARMING METHODS
Daily handling of the alarm system with the CB32G control panel involves arming and disarm-
ing of the system and checking possibly indicated alarm states. The control panel is operated
with the use of keypad buttons described below:
1,3,5,7,8,9,0 - - numeric only buttons,
2▲,◄4, 6►, 8▼ - - numeric and menu selection cursor buttons,
C - - cancel and menu exit button,
OK - - selection acceptance & confirmation button.
Current status of the system –date/time, arming mode of the control panel are displayed on
the LCD while failure, alarm and arming information are indicated by two LEDs:

- 4 -
"ALARM” –lights on (red) at alarm detection and flashes indicating system failure. Alarm sig-
nalling is cancelled after entering the main menu or re-arming the system. Fail-
ure signalling is cancelled after eliminating its cause.
“ARMED” –lights on (green) when the system is armed, flashes when exit delay time is
counted down.
The causes of alarms or system failures can be viewed upon entering main menu by holding
down OK button and next selecting Alarm Memory or Failure Check submenu.
ARMING & DISARMING OF ALARM SYSTEM.
Arming and disarming of alarm system with CB32G panel may be done from the control panel
keypad, by remote control transmitter (later referred to as a “remote”), by mobile phone SMS
or CLIP. Disarming alarm stops alarming and silences alarm sirens.
1. Arming & disarming alarm from CB32G panel keypad.
There are two possible methods of arming and disarming using the keypad depending on the
system ”day/night” operation mode selection, see Service Settings (S.S. for short) pt. 8.6:
1. Day/night mode is not selected “N” - see 8.6. By entering user’s password followed by OK
the system will arm if in disarmed state or disarm if in armed state.
2. Day/night mode is selected “Y” – see 8.6. By entering user’s password followed by OK the
system allows a choice of one of four supervision modes selected with “1”,”2”,”3”,“4” keypad
buttons, as described further:
“1 - disarm” - disarming the alarm –“disarmed” status appears on display. “active 24h” an-
ti-tamper zones remain armed.
“2 - arm” - arming the alarm. On end of the exit delay (signalled acoustically and optical-
ly with displayed time countdown on the LCD panel), all alarm zones, except
for permanently disabled, are armed. “Armed” status appears on display.
“3 - day” - partial arming of the alarm in day supervision mode. The zones earlier de-
fined as “day armed” and the “active 24h” zones are armed (as in 3.1). The
“day mode” message appears on display.
“4 - night” - partial arming the alarm in the night supervision mode. At the end of exit de-
lay (signalled acoustically and optically) all alarm zones are armed (*), except
for earlier defined as „night disabled” (as in 3.1.). The “night armed” message
appears on display.
2. Operating CB32G control panel using a remote (hand transmitter).
The CB32G panel can operate with Elmes Electronic made remotes in two ways (see pt. 5.7):
2.1 Remote arms and disarms the system.
Control panel may be armed/disarmed with the use of one, two or four button remote. With
the use of one button remote alarm system can be armed and disarmed alternately. With
two buttons remote, the second button may also arm the system in night mode. Four but-
tons remote features buttons for all optional modes of system arming (see pt. 5.7).
No matter which remote model, the use of standard system arming button triggers loud
sound signal (*) and the countdown of exit delay time starts. The system arms on the de-
lay passage. The use of system disarm button triggers two loud sound signals (*) and the
system disarms. If, while in the armed state, intruder alarm occurred then five loud sound
signals will be produced (*).
Arming system in night mode is similar to standard arming (exit delay is also used) with
the difference that sound signals on built-in siren are quieter and are not produced on
OUT1 nor WSS, while day arming is different, it is instant and no exit delay is used.

- 5 -
2.2 Remote activates entry zone delay only.
In this mode pressed remote button activates entry delay function in zone type “remote
delayed” for predefined delay time, signalled by two loud beeps (*). Now, system should
be disarmed by entering valid password from the keypad. Violation of “remote delayed”
zone while in entry delay countdown without system disarming will set up intruder alarm
after passage of the delay.
(*) Loud signal beeps can also be obtained on an external siren wired to OUT1 (see 9.4), then
beeps from internal siren are at low volume. Loud beeps are also available on wireless Elmes
Electronic WSS siren (see S.S. 9.5).
3. Arming & disarming using a mobile phone.
The GSM32G control panel may be remotely armed and disarmed by SMS command or CLIP
call from any entitled mobile phone number listed in the panel memory.
4. Arming the system bypassing selected alarm zones.
If, in the course of arming the system from control panel keypad, remote or mobile phone
SMS or CLIP, one of the zones detects intrusion, the response of the system depends on
whether the zone was earlier defined as “bypass” type (see item 3.1.g) and will be as follows:
-if the zone is defined as “bypass” type (Y) –the system generates 3 beeps and, if arm-
ing using keypad or remote transmitter only, prompts whether to arm the system without
arming the intruded zone. Acceptance with the use panel OK button or remote button
arms the system bypassing that zone. The use of any other button or no response (>8s)
cancels arming procedure. Arming using mobile phone will arm the system and in return
SMS will be received informing of the bypassed zone.
-if the zone is not defined as “bypass” type (N) –the control panel produces 3 beeps and
displays message “Violated zones” with zone name and system will not arm. In that
case, the cause of the zone violation should be cleared off and a new arming should be
made. While arming by mobile phone, the system will respond by sending SMS with in-
formation on violated zones.
See also S.S. pt. 9 –“System arming signalling modes”
CB32G SELECTED FUNCTIONS DESCRIPTION
Wireless detector state monitor
Elmes Electronic CB32G control panel allows testing the operation of all wireless detectors in-
stalled in alarm zones by simultaneous display of their on/off status. To activate/deactivate
this function button “1” on the keypad must be pressed and hold down until two 16 points lines
scale appear/disappear on the LCD panel. The displayed points represent all 32 wireless de-
tectors that can operate with the CB32G control panel. Any detector activated in the system
produces “*” mark to be momentarily displayed on the LCD at point position corresponding to
alarm zone number to which the detector was learned. Tamper switch activation in the detec-
tor produces mark “S” to be displayed in the corresponding zone point on the scale.
Sabotage protection of external devices
Connecting TAMPER switches of external devices (e.g. outdoor siren) as shown on the dia-
gram of Fig.2 enables anti-sabotage protection of these devices. Cutting off or shorting of the
tamper wire generates sabotage alarm in zone 32 of the control panel. If the TAMP terminal is
not used, it must be shorted to the GND terminal with 1kOhm resistor (supplied). The TAMP
input terminal may be used to connect any parametric wired alarm detector to the CB32G con-
trol panel.
Operation with wired alarm detectors
Two parametric zones of the CB32G control panel allow connection of any wired alarm detec-
tors with NC (normally closed) output terminals. Input EXT of the panel connects wired detec-

- 6 -
tor to alarm zone 31 while input TAMP may be used to connect wired detector to alarm zone
32. Detectors’outputs wiring should be parametric configured using resistors (supplied) with
one end wired to the GND terminal, as shown on fig. 1 of the manual. Wired detectors are
recognized by the panel the same way as wireless detectors. Alarms are detected in the zone
type selected by installer while sabotage protection is supervised as 24h type zone, perma-
nently armed. Parametric resistors should be terminal connected inside wired detector’s hous-
ing. Wired detectors must be powered by external AC/DC power pack. To ensure detector’s
proper operation at AC power failure, power pack with integral battery backup should used
(buffered power pack).
IMPORTANT: Zones 31 and 32 of CB32G panel are factory set “disabled”. When wired detec-
tors are installed, the zones should be enabled –see S.S. 3.4.
Operation with remote control transmitter (remote)
The use of Elmes made remote to operate with Elmes CB32G control panel allows remote
arming/disarming of alarm system as well as enables entry delay time for disarming from pan-
el’s keypad. Also, panic alarm may be triggered using a remote. Detailed description of re-
mote functions can be found in pt. 2 of Arming & Disarming of Alarm System section. Learning
a remote to CB32G panel is made according to S.S. 5.3. Additionally, in “System users...”
menu pt. 5.7, a selection must be made as to whether the remote arms/disarms the system or
sets on entry delay only. Also, in 8.7 –a selection whether panic alarm is required or not, and
in 9.4 and 9.5 define how the control panel should signal the use of a remote.
Operation with external wireless siren
The Elmes CB32G wireless panel can operate with dedicated external wireless sound and
strobe siren Elmes WSS that features integral transceiver module allowing periodical siren
presence test. The siren is powered by external mains power pack (delivered with the siren)
that recharges internal, not serviceable, sealed battery being siren’s main source of power
supply. The following steps are required to set Elmes WSS wireless siren operates with the
CB32G control panel:
1. Learn the siren to alarm zone line 29 of the CB32G panel by selecting detector learning
mode (see 3.3) and activating the siren to transmit alarm signals in one of the three ways,
as below:
a. Connecting siren’s battery while mains power supply is off.
b. Connecting or disconnecting mains power while battery is connected.
c. Activating siren’s housing top cover sabotage switch.
2. Set required alarming time at OUT1 of the panel that equals to alarming time of the wire-
less siren (4.3).
3. Set required interval (1 to 99 minutes –20 minutes as standard) between which wireless
siren presence is checked (described in S.S. 6.4) and enable radio link testing (pt. 8.2).
4. Choose the way alarm system signals that radio link between wireless siren and the control
panel is in fault. If the system is expected to set on loud alarm along with failure indication,
the function in pt. 8.10 should be set to ON. If only failure indication is required then the
function should be OFF.
5. If control panel is armed/disarmed by a remote, its use may be sound signalled by exter-
nal siren, if the option is on (see pt. 9.4 and 9.5).
NOTICE! To avoid loud TAMPER alarm during maintenance service or installation when si-
ren’s housing is to be opened, temporarily disable alarm zone line 29.
GSM module features
The following features are available when using CB32G panel : remote arming and disarming
of alarm system by SMS or CLIP call, requesting system status notification, remote disabling

- 7 -
of alarm zones, SMS notifications to up to 8 mobile phones on alarms, arming/disarming, AC
supply failure and return as well as system failures. Notifications include information of the
source of the event. In case of intruder alarm and sabotage alarm, control panel makes also a
CLIP call to registered phone numbers. It may also operate with any GSM mobile monitoring
system by responding to its test signals and sending cyclic SMS notes or making CLIP calls.
Starting from firmware ver.1.30 control panel outputs may be controlled by SMS.
CB32G panel configuration and firmware upgrade using PC
The CB32G control panel can be easily configured and firmware upgraded with the use of
Windows® based PC (Personal Computer). To connect the panel to PC a dedicated USB-RS
interface cable is needed (ordered separately). Also, installation of virtual COM port drivers at
the PC are necessary. The drivers as well as dedicated “CB32 Configurator” configuration
software are free for download from the panel manufacturer web site: www.elmes.pl .
Before any data is send to or received from the CB32G panel, the following installation steps
should be followed:
1. Select serial COM port that appears new in “CB32 Configurator” options after connecting
the USB-RS interface cable to PC.
2. By holding down button “2” of the panel’s keypad at power on, force the panel to set up
communication mode with PC. Displayed flashing “?” sign on panel’s LCD confirms the mode
has been entered.
MAIN MENU
To access the main menu of the CB32G panel press and hold down OK button for more than
two seconds. Navigate the menu using vertical and horizontal cursor keys. If the keypad is not
used for more than 90 seconds the menu exits and display of the current status of the control
panel on the LCD panel returns. Main Menu consists of four submenus:
Alarms Memory
In this menu details of the latest alarms are displayed: date, time and zone of the alarm(s)
source. The use of ▲▼ keys selects earlier or later events respectively, while the use of ◄►
buttons selects between alarm type and alarm source, e.g. “Intruder alarm” ↔ “kitchen”.
Failures
This menu is designed to view the causes of the failures signalled on the control panel by
flashing “ALARM” LED. Failures signalled on the control panel include:
▪Mains power supply failure.
▪Rechargeable battery absence or failure.
▪Communication errors with wireless detectors or siren.
▪Detector’s low battery.
▪Communication error with GSM module.
▲▼keys are used to scroll through failures.
The “ALARM” LED stops flashing when the cause of failure is cleared.
System Status
In this menu there are two submenus are available:
1. Displays level of received GSM signal by built-in module in graphic mode. Minimum of four
bar level is required for proper functioning. Lower lever requires change of panel placement.
2. Control panel firmware version is displayed.
Service Settings (S.S.)
Access to Service Settings menu is enabled only if the control panel is disarmed and upon en-
tering a valid password code confirmed by OK button. Factory setting of the password for the
user No.1 is „0000”. Exit from the menu and cancelling entries are made by the C button. Us-

- 8 -
ers Nos. 1-4 (administrators) have access to all functions whereas other users may access
functions 1-2 only. All editable service settings available in this menu are described further.
1. Event Memory
Service settings → Events memory
This menu allows viewing detailed information on last 256 events that occurred in the system
(alarms, failures, arming, disarming, errors, etc.). Event memory cannot be edited, and allows
only viewing the event details in the sequence of their occurring date and time. Buttons ▲▼
select an earlier or later event while ◄► buttons select between type of event and its source,
e.g. “Arming” ↔ “John”.
2. Password Change
Service settings → Password change
This menu allows changing user’s own password. Password of other users can be changed in
the “Users” menu (see pt. 5). After accessing this menu “Enter password” prompt appears.
Enter new password containing 3 to 6 digits, and then press OK. When the “Repeat pass-
word” prompt appears, enter the new password again and press OK. The new password re-
places old one. In case of entering an existing or incorrect password “Wrong password” mes-
sage appears.
3. Alarm Zones
This menu contains several submenus. Entering any submenu with ▲▼ buttons selects
zones while ◄► buttons select between zone number or zone name, e.g. “Zone no 1” ↔
“Kitchen”.
3.1. Assigning functions to alarm zones.
Service Settings → Alarm zones → Zone function
In this menu Elmes CB32G control panel allows assigning functions to alarm zones. Buttons
▲▼ select one of the functions described below while ◄► buttons allow setting the function
ON (Y) or OFF (N). The use of OK button accepts the selection while the use of C button can-
cels changes and exits the menu without saving changes.
a) “24h” - 24 hour zone, e.g. anti-sabotage zone (permanently armed),
b) “day armed” - zone armed in day supervision mode selection,
c) “night disabled” - zone disabled in night supervision mode,
d) “remote delayed” - zone with entry delay set on by remote control transmitter,
e) “delayed” - standard entry zone with delayed alarming,
f) “chime” - zone with door chime beep feature on zone violation,
g) “bypass” - zone that can be left disarmed if violated on system arming.
h) “silent alarm” - zone violation sets on silent panic alarm (no siren sounds) and
panel’s outputs type “silent alarm” will set on. If the zone is re-
quired to be armed all the time, function “24h” must be on as well.
A standard zone has functions a)..c) set off in armed state mode, when the system is “armed”
or in “night armed” mode and disarmed when the system is “disarmed” or in “day armed"
mode. IMPORTANT: Zones can have assigned more than one function, but some functions
exclude others. In that case, only one selection is valid, e.g.:
-if zone is “active 24h” then functions such as “day armed”, “night delayed”, “delayed”, and
“bypass” have no meaning;
-if zone is delayed, it should not be disabled by remote.

- 9 -
Examples of assigning functions to alarm zones:
Entry zone can be “remote delayed”, i.e. after using remote button entry delay countdown
is started. Security violation in the zone during the countdown will not generate the alarm
immediately, but after the countdown is finished. That allows user sufficient time for safe
disarming the system.
Entry zone can also be a delayed zone, i.e. when the zone is violated, the entry delay
countdown starts and the system must be disarmed before the countdown is finished. If
system is not disarmed an audible alarming sets on.
The “chime type” zone which often is also a “delayed” or “remote delayed” zone, gener-
ates two beeps sound signal on every violation of the zone (e.g. notifying customer en-
trance to a store).
A basement zone can be “day armed” but it cannot be “active 24h” simultaneously.
A „bypass” zone type allows arming the alarm while intentionally leaving a window
opened protected by CTX detector (see “System Arming”).
3.2. Zone name.
Service settings →Alarm zones → Zone name
This menu allows alarm zones used in the system to have user defined up to 16-character
name, e.g.: kitchen, living room, office, Mark’s Room, etc. Uppercase and lowercase letters,
digits and the following characters are accepted: space, “-,./”.
Buttons ◄► select the successive letters of the name while the ▲▼ buttons browse charac-
ter table. Accept name with OK button. Use C button to exit the menu.
3.3. Learning wireless detectors to control panel.
Service settings → Alarm zones → Learning detectors
In this menu use the ▲▼ buttons to select zone number, and the ◄► buttons to toggle be-
tween displaying the zone number and zone name, e.g.: zone 1 ↔ kitchen. OK button accepts
all selections. If detector is already learned to selected zone, “OK-remove” prompt appears.
Pressing OK button deletes detector in the zone. If zone is vacant, the “OK-learn” will appear
on the LCD. Pressing OK button starts learning detector to the zone. In response to the
“Awaiting trans. 1” and “Awaiting trans. 2” prompts, two successive alarm transmissions must
be triggered from detector (*).Correct learning will be followed by “OK-correct” message. Er-
rors are signalled by 3 beeps and “Program error” message. The use of C button exits the
menu.
(*) For detailed information on how to learn any Elmes detector to Elmes CB32G control pan-
el please refer to instruction manual of the detector.
3.4. Zone disabling.
Service settings → Alarm zones → Zone disabling
Buttons ◄► disable and enable zone selected with ▲▼ buttons. Accept selection with OK
button. Exit the menu with C button.
3.5. Radio range test.
Service settings → Alarm zones → RF range test
To assess the level of radio reception of signals received from detectors, the most distant de-
tectors in particular, the CB32G panel is provided with “RF range test” function allowing the
received signal level to be displayed on 16-point bar graph scale of LCD.
After entering this menu all RF signals in the 433.92MHz radio band will be displayed in form
of bar graph. The detectors should be triggered to send alarm transmissions. The longer the
distance of the detector from the control panel, or the greater difficulty in radio waves propa-
gation, the lower the level of received signals and the length of the displayed bar graph. If the
number of displayed fields is lower than three it should be assumed that this connection does
not guarantee reliable alarming. The location of detectors or the control panel should be

- 10 -
changed in search for better connection quality. The “RF range test” function allows also as-
sessing levels of all local RF signals in the 433.92MHz band, also those that can interfere and
disturb operation of the wireless alarm system. The test should be carried out prior to perma-
nent installation of alarm devices or, in search for causes of short operation range. To find out
any interfering signals, the LCD bar graph 16-point scale readouts should be observed without
activation of own detectors. Frequent or continuous unknown RF signals received and sig-
nalled on the control panel display indicate close presence of other RF devices operating in
the same RF band. If level of these signals exceeds three fields displayed in the “RF range
test” function and their occurrence is frequent, acceptable signals from detectors may not be
received and the alarm system may fail to operate properly.
4. Outputs settings
This menu contains some submenus. Entering any of them select output number with ▲▼
buttons while OK button opens the submenu:
4.1. Output types.
Service Settings → Outputs → Output types
This menu allows allocation of wired outputs of the control panel. All three outputs of the panel
are OC type and connect to ground in active state. Output OUT1 is designed exclusively for
connecting external signalling device and can be sabotage protected (see S.S. pt. 8.3). In ad-
dition, this output can be configured to beep signal the use of a remote. The use of wired out-
puts OUT 2-3 could have the following allocation:
“alarming”- for connection of outdoor/external alarm signalling devices, e.g. ex-
ternal siren or/and strobe. Alarming time can be set within 1to 999 sec-
onds range separately for each output (see 4.3);
“AC power failure” - signalling AC power supply failure/cut off;
“arming” - signalling on system armed or night armed and inactive on system
disarmed or in day armed mode;
“failure” - signalling any failure state in system (also AC power failure);
“SMS controlled” - output controlled by SMS. Examples of SMS controlling panel output
named OUT2 are shown below:
„OUT2 T” - permanently sets output on;
„OUT2 N” - sets output off;
„OUT2” - sets output on for time specified in pt. 4.3;
„OUT2 15” - sets output on for 15 seconds;
„OUT2 10:30” - sets output on for 10 minutes and 30 seconds;
„OUT2 1:00:00” - sets output for 1 hour.
Output maximal set on time is 18 hours, 12 minutes and 15 seconds.
„silent alarm” - output will be set on, if zone type “silent alarm” has been violated
(pt. 3.1h), or silent panic alarm is activated (pt. 8.7).
Example: if “arm/disarm” signalling mode is selected at OUT 2 and the output connects LED,
bulb lamp, etc. to external power supply, it will stay lighted on for as long as the system is
armed offering additional signalling or warning option.
Output type of OUT 2 & 3 are defined by accessing the menu, selecting output number with
▲▼ buttons, accepting with OK, selecting output type with ▲▼ or ◄► buttons, accepting se-
lection and exit with OK button.

- 11 -
4.2. Output name.
Service Settings → Outputs → Output name
This menu allows every output to be described by any up to 16-character long name e.g.
“OVEN”, “Lamp”, etc. Upper and lower case letters, digits and “-,./” signs are accepted while
“space” sign is not allowed. “OUT2” should be used instead of “OUT 2”. Output’s names are
used only if controlled by SMS.
Outputs OUT 2 & 3 names are defined in the menu with ◄► buttons selecting character posi-
tion in the name and ▲▼ buttons selecting appropriate character. Such defined output name
is accepted with OK and menu exit with C button.
4.3. Outputs set on time.
Service Settings → Outputs → Output time
This menu is used to define individual set on time, ranging from 1 to 999 seconds, of
outputs type “alarm”, “silent alarm” and “SMS controlled”. Set on time defined for any other
output type is irrelevant. Set on time defined for output OUT1 also defines set on time for ex-
ternal wireless siren (Elmes Electronic WSS).
5. System users - adding, editing and removing a user
Service Settings → System Users
This menu contains several submenus. Entering any submenu with ▲▼ buttons selects sys-
tem user number while ◄► buttons select between user number or user name, e.g. “User no
1” ↔ “John Dutch”. Accept user selection with OK button and pass on to submenu:
5.1 Setting and edition of user password.
Service Settings → System Users → Password
Please follow detailed instructions in “Password Change” menu (S.S.1).
To delete user’s password press OK button when “Enter password” prompt appears. On next
prompt “OK-delete password” again press OK button. “Password deleted” message confirms
password is deleted.
5.2 User name change.
Service Settings → System Users → Name
Please follow detailed instructions as in “Zone name” menu (S.S. 3.2)
5.3 Remote learning and deleting.
Service Settings → System Users → Learning a remote
In this menu user’s remote is learned or deleted. Please follow detailed instructions in “Learn-
ing detectors” menu (S.S. 3.3).
5.4 Disabling of user.
Service Settings → System Users → Disabling user
Please follow detailed instructions as in “Zone disabling” menu (S.S. 3.4). After disabling a
user, its remote and password are inactive. In order to disable user’s control of CB32G panel
by SMS or CLIP, the functions should be set off in 5.6.9 and 5.6.10 of S.S.
5.5 Mobile phone number.
Service Settings → System Users → Phone number
This menu allows entering user’s mobile phone number. The number must be preceded by
national dialling code number, without the “+” sign. Example: 33xxxxxxxxx for France.

- 12 -
5.6 Mobile phone functions.
Service Settings → System Users → Phone functions
This menu allows selection (Y/N) of notifications, messages, commends and SMS/CLIP func-
tions required active in user’s GSM phone operating with CB32G control panel.
1) SMS on alarm - sending SMS on alarm set on;
2) SMS on arming - sending SMS on arming and disarming of system;
3) SMS on powering - sending SMS on mains power failure and return;
4) SMS on radio link off - sending SMS on radio link failure;
5) SMS on low battery - sending SMS on low battery;
6) SMS on other failures - sending SMS on other failures (e.g. accumulator failure);
7) Alarm CLIP - making alarm CLIP call;
8) Descriptive SMS <-> SMS with ID codes –selection of SMS content: event description
such as “Intruder Alarm” or the use of special codes (see pt. 7.9, 7.10, 7.11.7);
9) SMS accept - SMS commands (as below) acceptance received by CB32G.
ARM, DISARM, NIGHT and DAY- sets appropriate arming mode;
DISABLE zone_name - disables zone: zone_name;
ENABLE zone_name - enable zone: zone_name;
STATUS - in response control panel sends SMS on current
armed/disarmed status and failure events;
TIME HH:MM - sets time in control panel;
TEST - sets up instant test procedure and starts time count to next test under condition
that “Test every time interval” is selected in 7.11.2 and “Execute test” function is
selected in 5.6.12.
OUT2 - sample control command for output named OUT2. Detailed description of control-
ling outputs by SMS commands can be found in pt. 4.1.
10) CLIP arming - remotely CB32G panel arming and disarming by CLIP call. Panel is dis-
armed if call is rejected after one ring. If the call is rejected after three rings, the panel is
armed.
11) Call back - calling back function. If the control panel is called, it will call back. This and
next function may be used in operation with monitoring centre:
- if the function is set on, GSM monitoring centre calls to CB32G and the panel rejects the
call after 3-4 seconds,
- if the function is set off, the control panel calls back the monitoring centre after rejecting
incoming call.
12) Execute test - executing SMS or CLIP time interval test by CB32G panel. The function
may be used in operation with alarm system monitoring centre (pt. 7.6, 7.7, 7.11).
5.7 Remote type and mode of operation.
Service Settings → System Users → Remote type
This menu allows selection of remote’s operation modes. Description: 1CH-one channel re-
mote, 2CH-two channels remote, 4CH-four channels remote.
1CH: arm/disarm -any selected button alternatively arms and disarms control panel. Re-
maining buttons, of e.g. 4-channels remote, may be used for other remote control purpos-
es.
2CH: arm/disarm, night/disarm - button 1 (green) of 2-channels remote (*) arms and disarms
control panel alternatively while button 2 (red) arms in night mode and disarms the panel.
2CH: disarm, arm - button 1 (green) of 2-channels remote (*) disarms while button 2 (red)
night arms the panel.
This mode allows real time clock channel of Elmes STX remote to arm/disarm control
panel automatically, at predefined times.

- 13 -
2CH: disarm, night arm - button 1 (green) of 2-channels remote disarms while button 2 (red)
arms in night mode.
4CH: disarm, arm, night, day arm - button 1 (green) disarms system, button 2 (red) arms, but-
ton 3 (blue) night arms, button 4 (grey) day arms.
(*) In this mode a 4-channel remote can also be used. Button 1 is then meant as the first of 1-
2 or 3-4 buttons pairs.
Remote sets on delay - remote sets on entry delay in “remote delayed” zones (see pt. 3.1.d).
NOTE: Users 1..4 are system administrators with unlimited access to all service functions,
whereas other users have access to Service Settings functions 1 and 2 and are allowed to
change their password and review CB32G event memory only.
6. System times
6.1. System date/time setting.
Service Settings → Times → System date/time
This menu allows setting system date and time. The ▲▼ and ◄► buttons are used to select
current date and time and the use of the OK button accept the selection. Exit the menu with C
button.
6.2. Entry delay time (0..99s).
Service Settings → Times → Entry delay
This menu allows setting the alarm activation delay time (in seconds: 0 to 99) needed to enter
the premises and disarm alarm system from the CB32G keypad. Two digits on the right side
of the display show available entry delay time in seconds. The required time is set with the
use of cursor buttons and accepted with the OK button.
6.3. Exit delay time (0..99s)
Service Settings → Times → Exit delay
This menu allows setting time delay needed to exit premises (in seconds: 0-99) after alarm
system arming from the CB32G keypad. Two digits on the right side of the display show avail-
able exit delay time in seconds. The required delay time is set with the use of cursor buttons
and is accepted with the OK button.
6.4 Wireless siren check up interval (1..99 minutes).
Service Settings → Times → WSS siren check-up interval
This menu allows setting time interval between checking of Elmes WSS wireless siren pres-
ence (in minutes: 1 to 99) - as standard set to 10 minutes. The required interval time is select-
ed by the use of cursor buttons and accepted by OK button.
6.5 Control panel clock run adjustment.
Service Settings → Times → Clock adjustment
This menu allows adjustment of control panel clock fast/slow run within -99 to +99 steps
range. Decreasing steps slow the clock while increasing steps speed up clock. One adjust-
ment step equals 0,0864 second fast/slow run per day (24h).
7. Alarm notification by GSM module
This menu defines required settings for alarms and other notifications send by GSM module of
the CB32G panel.
7.1 SMS centre phone number.
Service Settings → GSM monitoring → SMS Centre number
This menu is used to enter the phone number of GSM operator’s SMS centre, preceded by
country code dialling without “+” mark in front. This is important if “Use entered SMS centre

- 14 -
no” selection is made in menu 7.11.6. If option “Use default SMS centre no” is selected, this
field can be left empty. Example: the following phone number should be entered for Plus GSM
operator in Poland: 48601000310
7.2 Number of alarm & arming SMS notifications daily limit (24h).
Service Settings → GSM monitoring → Alarm SMS daily limit
Feature allowing limitation of daily SMS notifications send by CB32G control panel on system
alarm, arming and disarming. Limit is factory set to 99 and resets daily at 12:00 hours.
7.3 System failure SMS notifications daily limit (24h).
Service Settings → GSM monitoring → Failure SMS daily limit
Feature allowing limitation of daily SMS notifications on system failures send by CB32G con-
trol panel and registered in event memory. Failures are divided into three categories. First
category includes “Mains power failure”, “Accumulator failure” and “System restart”, second
“Radio link failure” and third “Low battery” failure. SMS notification limit is factory set to 10 in
each category and resets daily at 12:00 hours. Change of factory limit (10) results in limit
change in all categories and CB32G event memory.
7.4 Calling duration.
Service Settings → GSM monitoring → Calling duration
This feature defines duration of CB32G alarm notification CLIP calling. It should be set to time
value allowing user to reject call before the time lapse if function “Alarm CLIP once” (S.S.
7.11.5) is set off. See also pt. 5 of FAQ section of manual.
7.5 SMS password.
Service Settings → GSM monitoring → SMS password
This menu is used to enter a maximum 6-character password that will precede SMS com-
mand text, if option “SMS with password” is selected in 7.11.3.
7.6 Test SMS.
Service Settings → GSM monitoring → Test SMS
This menu is used to enter Test SMS content send by GSM module when test function is set
on in 5.6.12 and “Test as SMS” option is selected in 7.11.1.
7.7 Test interval/Test time.
Service Settings → GSM monitoring → Interval/Test time
This menu is used to enter time interval (if option “Test interval” is selected in 7.11.2) or, test
time (if option “Test time” is selected in 7.11.2) when the CB32G control panel is expected to
perform SMS or CLIP test. Maximum value is 24h. This feature is valid only if “Execute test”
option is selected in 5.6.12.
7.8 Switching integral GSM module ON and OFF.
Service Settings → GSM monitoring → GSM ON/OFF
This menu is used to switch on/off control panel GSM module operation. Enter the menu with
OK and select GSM Module ON or OFF operation using ◄► buttons.
7.9 Definition of SMS notification ID codes.
Service Settings → GSM monitoring → SMS ID codes
This menu is used to enter two character ID codes send in SMS event notifications. Each
code contains two characters (ASCII codes in range 32 to 90 decimal), e.g. some symbols,
digits and uppercase English alphabet characters. To set the CB32G panel to send ID codes
instead of standard text notification, such as “Intruder alarm: kitchen”, option “SMS with ID
codes” must be selected in S.S.5.6.8.

- 15 -
7.10. Definition of monitoring station subscriber account number .
Service Settings → GSM monitoring → Subscriber account number
This menu is used to define subscriber code (max. 8 characters) used by monitoring station
operating in e.g. “Ademco Contact ID” to identify SMS notification sender (see pt. 7.11.7).
7.11. Auxiliary GSM notification settings.
Service Settings → GSM monitoring → Aux GSM settings
1) Test as CLIP <-> Test as SMS - interval test as CLIP call or SMS;
2) Execute test at time <-> Execute test after interval - test executed daily at predefined test
time, or test after predefined time interval;
3) SMS with password - if Y (yes), SMS send to CB32G must begin with password;
4) Letter case sensitive - N (no) as standard. If selected Y (yes), the control panel is SMS let-
ters case sensitive;
5) Alarm CLIP once - if this function is set off (N), control panel expects CLIP notification re-
jection. If the call (see pt. 7.4) is not rejected, the panel disconnects and repeats CLIP call
twice. If the function is set on (Y), CLIP calling is made once only, even the call was not re-
jected. It does not refer to a control CLIP that is made only once;
6) Use default SMS centre no <-> Use entered SMS centre no –selection of the first option
allows CB32G panel to use SMS centre number supplied with SIM card, while selection of
the second option causes CB32G to use centre number entered in 7.1.
7) Ademco Contact ID→ Subscriber + event code → Subscriber + event code + zone no
The settings is valid only, if “SMS with ID codes” is set on in pt. 5.6.8 and allows selection
of one of three SMS notification patterns send to monitoring station:
1) ”Ademco Contact ID” pattern. SMS notification has the following form:
CCCCQEEEGGZZZ
where “CCCC”stands for subscriber code set in pt. 7.10. Other elements are defined by
the user, e.g. three digits event number “EEE”. NOTE: if monitoring station requires digits
“18” to appear before “CCCC” then subscriber’s code should input as “18CCCC” in
pt.7.10.
2) ”Subscriber + event code” pattern. SMS notification has the following form:
CCCCEE
where CCCC stands for subscriber code set in pt. 7.10 and “EE” event code set in pt.7.9.
3) ”Subscriber + event code + zone no” pattern. SMS notification has the following form:
CCCCEEZZ
where CCCC is subscriber, “EE” event code and end “ZZ” is zone or user number.
8. Auxiliary functions settings.
This menu contains auxiliary functions and options for alarm system configuration available in
the CB32G control panel. Use ▲▼ to toggle between functions and ◄► buttons to change
setting. OK button saves selection. Exit menu any time with C button without saving selection.
8.1 Radio jamming protection.
Service Settings → Aux functions → Jamming protection
This function allows radio jamming anti-sabotage protection of wireless alarm system. If se-
lected (Y), it will activate sabotage alarm in zone 30 on all deliberate or incidental jamming in
used radio band.
8.2 Radio link test.
Service Settings → Aux functions → Radio link test
Setting this function to (Y) enables monitoring of the detector presence. Radio link transmis-
sions are sent at cyclic intervals from detectors (except for CTX3H) received by CB32G con-

- 16 -
trol panel. If, for any reason, radio link transmission from a detector is not received during 24
hours, “radio link failure”will be indicated by flashing “ALARM” LED in the panel.
8.3 Anti-sabotage protection test of output 1.
Service Settings → Aux functions → Out1 Test
OUT1 output, which is by default used for connecting an external signalling device, is provid-
ed with anti-sabotage (Tamper) protection against wires cutting off or shorting to ground. After
accessing this menu the user can turn this protection on or off. Damage, cutting off or shorting
wires connecting this output with external signalling device - is indicated by sabotage alarm in
zone 32.
8.4 Internal siren alarming.
Service Settings → Aux functions → Internal siren
This option allows setting on/off alarm signalling by control panel internal siren.
8.5 Signalling accumulator absence or failure.
Service Settings → Aux functions → Accu failure
This option allows setting on/off CB32G internal accumulator failure signalling, recommended
to be set to off (N) when rechargeable batteries are not used.
8.6 Activating selection of day & night arming modes.
Service Settings → Aux functions → Day/night mode
Activating the function (Y) will display additional menu on LCD allowing selection of supervi-
sion modes confirmed by password and the OK button. There are 4 modes available: 1 - dis-
armed, 2 - armed, 3 –day, 4 –night (see also: “Arming/disarming alarm system”). With the
function set off (N), the menu is not displayed and entire alarm system can be armed and dis-
armed from control panel keypad by password followed by OK. Partial night mode and day
mode arming would not be available to set on from keypad. However, night mode arming is
still possible if arming is made by the use of a remote (see details in 5.7).
8.7 Setting on panic alarm or call for help function.
Service Settings → Aux functions → Panic alarm off / Loud panic alarm / Silent panic alarm
This function allows activation of panic alarm for users equipped with remote control by longer
than two seconds pressing the remote’s button. Control panel starts alarming and registers
the event as panic alarm with name of the user that activated the alarm and sends appropriate
SMS notification. Loud panic alarm differs from silent panic alarm by setting on outputs type
“silent alarm” while alarm sirens remain off (see pt. 4.1).
Switching activated panic alarm OFF is done by entering a password from keypad or by the
use of a remote, if this option is set on for the remote (pt. 5.7).
8.8 Control panel beep on/off.
Service Settings → Aux functions → Keypad beep
This option allows setting on/off all control panel beep signals except for signalling an intruder
alarm that can be set off in 8.4.
8.9 Beeps on entry delay count on/off.
Service Settings → Aux functions → Entry delay countdown beep
This option allows setting on/off entry delay countdown beep signals in addition to countdown
display on control panel LCD.
8.10 Alarm on radio link with WSS siren failure.
Service Settings → Aux functions → WSS siren link alarm
Setting this function to yes (Y) allows loud alarm along with LED alarm notification on wireless
Elmes WSS siren radio link check-up test failure. As standard the function is set to no (N) and

- 17 -
the failure is signalled by flashing Alarm LED only. Failure check menu will display “Radio link
error” and name of zone 29 (if specified).
8.11 Limitation of alarms from one alarm zone.
Service Settings → Aux functions → Alarms limit to3
This function limits number of alarms in one zone to three and is factory set to on (Y). Alarms
count is reset on every arming or disarming of the system. When the limit is selected to off (N)
alarm sets on every time violation is detected in the alarm zone.
8.12 Selection of menu language: Polish/English.
Service Settings → Aux functions → Język polski / English language
This function allows selection of the panel’s menu language: English or Polish.
NOTE! Change of menu language can also be made with button “1” of the keypad held down
while connecting power supply to the panel.
8.13 Backlight modes of LCD panel and keypad.
Service Settings → Aux functions → Permanent backlight
Setting this function to yes (Y) selects permanent backlight of LCD panel and the keypad. As
standard the function is set to no (N), meaning the LCD panel and the keypad are backlit upon
any key on the keypad is pressed. Backlight sets off within 40 seconds of last key pressed.
9. Signalling modes of system arming.
Service Settings → Arming signalling
This menu allows selection of alarm system arming and disarming signalling modes. Use ▲▼
keys to toggle between functions and ◄► keys to change setting. OK button saves selection.
Exit menu any time with C button without saving selection.
9.1. Remote: pulses ↔ Remote: pulses + SMS if problem –selecting the first option sets on
sound pulses on sirens only. Selecting second option allows sound pulses on sirens and SMS
notification if any problem occurs (*).
9.2. SMS: SMS ↔ SMS: pulses + SMS if problem –selecting first option a return SMS is
send on SMS arming. Selecting second option sets on sound pulses only and SMS notifica-
tion is received only if problem occurs (*).
9.3. CLIP: SMS ↔ CLIP: pulses + SMS if problem –selecting first option a return SMS is
send on CLIP arming. Selecting second option sets on sound pulses only and SMS notifica-
tion is received only if problem occurs (*).
9.4. Loud internal pulses ↔ Pulses on OUT1+ quiet internal –selecting first option sets on
arming sound pulses on internal siren only. Selecting second option sets on pulses on exter-
nal siren connected to OUT1 along with quiet sound pulses signalled on internal siren.
9.5 Pulses on WSS -setting on/off arming sound pulses on wireless Elmes WSS siren.
(*) While system arming violation of a zone may occur. Depending on whether the zone is
“bypass” type (see 3.1.g), the system will arm and SMS notification will be send informing of
the bypassed zone/s or, if the zone is not “bypass” type, the system will not arm and SMS no-
tification will be send with information of violated zone/s.
SETTINGS RESET
Resetting password of user number 1.
If user no 1 is disabled or its password is lost and there is no way to enter Service Settings
menu of the control panel, it can be hardware enabled and have factory password “0000” re-
stored, in the following way:
1. Open the panel’s cabinet (sabotage alarm may occur), disconnect AC power and remove
batteries.
2. Short circuit two points R marked (in the upper right corner of the panel board).

- 18 -
3. Connect power supply or insert batteries and then disconnect shorted R points.
User no 1 is now enabled and its password is restored to “0000”, zones 31 and 32 are disa-
bled and anti-sabotage protection control of OUT1 set off. All other settings remain un-
changed.
CB32G restore to factory settings (default settings).
Factory (default) settings are restored according to procedure described below. The proce-
dure restores factory settings deleting all wireless devices in memory. Records in the event
memory are not deleted.
1. Open the panel’s cabinet (sabotage alarm may occur), disconnect AC power and remove
batteries.
2. Short circuit two points R marked (in the upper right corner of the panel board).
3. While holding down button 3 of the keypad connect power supply –display will show noti-
fication: “Factory settings”.
4. Release button 3 and wait until control panel restores normal operation.
5. Disconnect shorted R points.
DESIGNING WIRELESS ALARM SYSTEM
Designing and installation of alarm system with the Elmes Electronic CB32G control panel
should start with careful planning of detectors, control panel and outdoor siren placement. To
ensure satisfactory protection of secured premises a variety of detectors may be needed.
Elmes Electronic PTX wireless motion detector and CTX wireless magnet contact detectors
should be installed in each protected room with window. Additionally, GBX wireless glass
break detector could be installed for protection of windows breakage in premises and shops.
Depending on needs, one or two wired detectors can be connected to the panel. The panel
will also operate with RP501 four channel transmitter offering one to four wired detection in-
puts to be monitored remotely. Learning the RP501 transmitter to the CB32G control panel by
activation of input no 4 will learn all four transmitter’s inputs to four adjacent alarm zones of
the panel. Activating input four of the RP501 while learning the transmitter to zone 20 of the
panel will assign four RP501 inputs to alarm zones no 17, 18, 19 and 20. When installing de-
tectors and RP501 transmitter respective instruction manuals must be followed.
It is highly recommended that before permanent installation of detectors or control panel op-
erating range tests should be taken to confirm reliable communication of the devices with the
CB32G panel. The RF range test allows evaluation of operation range of wireless devices.
This function available in Service Settings menu (3.5) and may also be helpful in detecting
any interfering radio signals. If signals received by the control panel are weak, there may be a
need to relocate installation places of some detectors or the control panel. In the extreme
cases, it is recommended that Elmes Electronic TRX signal repeater to be used to ensure
proper performance of the alarm system.
Installation place of detectors is determined individually. Access to the control panel should
meet specific needs of protected premises but it is not recommended to place the panel next
to the door or in place easily accessible. Best suggested way of disarming the alarm system is
to activate entry delay from outside of the premises with the use of a remote. It allows safe
opening the entrance door, access control panel keypad to disarm the system with password.
The entry delay programmed by an installer or user should allow convenient access to the
control panel keypad.
The CB32G control panel may also be installed in place such as bedroom or study room, al-
lowing complete elimination of the entry/exit delay time. In that case, arming and disarming of
the alarm system from the outside of premises can be made with the use of a remote or mo-
bile phone. Arming and disarming will be audibly signalled by siren or visually by lamp con-
nected to an output configured to arming and disarming signalling.

- 19 -
The panel features also the option of arming alarm system in the night mode with selected
rooms excluded from supervision (e.g. bedrooms, upper floor), as well as the day mode in
which only the selected rooms (e.g. cellar, basement, garage) are supervised. Arming entire
alarm system, or in night/day modes is done with the use of the CB32G panel keypad. Arm-
ing entire system or arming in the night mode only is also possible with the use of remote. All
options and functions of alarm system designed with CB32G control panel are user selected
and set in the Service Settings menu of the panel.
POWERING CB32G CONTROL PANEL
To ensure proper operation the CB32G control panel requires external AC/DC power supply
with 10...20VDC and 1200mA minimum current output.
Initial powering of the panel starts with inserting two 3,7V Li-ION rechargeable batteries
(14500 type, AA size) observing indicated polarity and screwing in DC output wires of the
AC/DC power pack to +/- terminals of the panel. Plugging the pack to AC outlet backlights the
LCD panel and displays software version followed by initial date (day_month), time (hour: mi-
nute: seconds:).
IMPORTANT! Use AA size (14500 type) 3,7V LI-ION rechargeable batteries only with rec-
ommended capacity of minimum 600 mAh. The use of other than Li-ION batteries is not per-
mitted. Correct battery polarity must be observed when inserting Li-ION batteries. Incorrect
battery placement will cause panel damage and repair service will be required. The use of
batteries with lower capacity than recommended could not guarantee 24 hours of autonomy
operation on AC power failure.
CAUTION! Batteries contain dangerous and poisonous substances. Do not dispose of waste
batteries with household waste. Dispose waste batteries according to your local recommenda-
tions or, ask for disposal instructions your battery supplier.
When operating CB32G connected to wired alarm system with power supply backup does not
require Li-ION battery installation and the control panel may be powered by the wired alarm
13,6 VDC auxiliary supply line voltage dedicated to power detectors, sirens, etc.
The CB32G control panel can also be operated without internal Li-ION batteries installed.
However, in order to assure its proper operation under AC power failure condition a buffered
power supply (ups) should be used. The use of buffered power supply with integral back up
battery is best recommended power supply solution.
NOTICE! Manufacturer supplies control panel with zone 31 EXT and zone 32 TAMP disabled
and anti-sabotage control of output OUT1 set off allowing connection of external siren and
power supply to the CB32G panel without activating sabotage alarm. After completing system
connections, inserting the batteries and closing panel case, the anti-sabotage protection
should be enabled.
ALARM SYSTEM WITH ELMES CB32G CONTROL PANEL
Designed alarm system may be less or more complex depending on individual needs. Sim-
plest alarm may consist of only few detectors and the control panel with internal siren for au-
dible signalling, while complex alarm system would have a range of detectors in addition to in-
ternal and external signalling devices.
The diagram presented further shows an example of a complex alarm system with the use of
Elmes Electronic PTX50 wireless motion detectors, CTX3H and CTX4H magnet contact (with
open & close signalling function) detectors, GBX glass break detector, UBM100H remote con-
trol for activating entry delay and panic alarm, wired external siren and CB32G control panel.
The system should be power supplied from a dedicated buffered power pack (if external,
wired siren is installed) with integral battery backup. If only wireless devices are used in the
system, it is sufficient to use control power with AC/DC pack and Li-ION rechargeable batter-

- 20 -
ies. Other advisory examples of alarm configurations with CB32G wireless control panel are
shown on Fig.1 and Fig.2.
Wiring of external equipment such as sirens and AC/DC power supply line to the CB32G con-
trol panel terminals, should be made through large installation whole and a cable groove in
the bottom part of its cabinet. Suggested installation of the control panel is in vertical position,
e.g. on the wall at the height of approx. 1.20 to 1.40m, allowing convenient entering keypad
commands. The configuration procedure for an exemplary alarm system described further as-
sumes that the user will use a remote control to activate the entry delay. It is recommended to
make basic settings, learn detectors and carry out the first tests on workshop table before
permanent installation in the premises. Following, are some essential basic steps to be taken
at first wireless alarm system configuration setting:
Unpack the CB32G control panel, insert Li-ION batteries (if needed) carefully observing polari-
ty (+/-) marked inside the panel cabinet and connect AC/DC power supply pack. After the con-
trol panel initialisation follow steps, as below:
1. Enter Service Settings menu by pressing and holding down OK button (initial password:
0000), and input current date and time (6.1). Enter new password (5.1), the name of the
first user and learn remote control transmitter to the user.
2. Unpack wireless detectors: Elmes Electronic PTX (motion), CTX magnet contacts (open-
ing/closing) and GBX (glass break), install batteries and configure according to the in-
cluded manuals and requirements of the alarm system. Install wired siren or learn dedi-
cated WSS outdoor wireless siren to CB32G panel.
3. Learn detectors to alarm zones of the panel (3.3) and test their operation with the “Alarm
detector monitor” function by pressing and holding down button 1 of the keypad until 2 x
16 dots appear representing alarm 32 zones and detectors. For details see ....
4. Set the zone with the entry detector as a „remote delayed” zone (S.S. 3.1.d).
5. Set the entry delay time (6.2) according to individual requirements.
The above steps allow first workshop tests of the constructed alarm system. The CB32G pan-
el’s internal siren will audibly signal all alarms and arming/disarming commands. After initial
Table of contents
Other Elmes Electronic Control Panel manuals
Popular Control Panel manuals by other brands

Sealey
Sealey SAC3103B quick start guide

olympia electronics
olympia electronics BS-1632 manual

Fasel Elektronik
Fasel Elektronik FCU2000 Series installation instructions

Bentel Security
Bentel Security BW-ODT manual

Digital Monitoring Products
Digital Monitoring Products XR500 Series Programming guide

Assa Abloy
Assa Abloy 1385 manual