OPERATING MANUAL
ELPRO CONTROLS,
Ahmedabad, Gujarat, INDIA
www.elprocontrols.com
FEATURES
Superior MCU based technology
perates on principle of conductivity
Controls M T R based on overhead and underground tank level
perating Mode : Auto / Manual
Models : LLC-2 – For 1HP to 2HP motor without start capacitor
LLC-2S – For 1HP to 2HP motor with start capacitor
LLC- S – For 2HP to 3HP motor with start capacitor
INSTALLATI N GUIDE
Connect H, L, C Probes in overhead tank.
Connect UH, UL, C Probes in underground tank.
Connect at least 0.5 mm 3 core wire from H, L, C and UH, UL, C terminal to
appropriate probes provided along with the unit.
Connect 230V AC supply to input terminal (P & N).
Connect output (P & N) to control panel ELPR make / ther make.
Connect C1 & C2 to START button of control panel (for LLC-2S & LLC-3S model).
Short P1 & P2 on START button of control panel for AUT mode (for LLC-2S & LLC-3S
model).
Tight all terminal connection to avoid any loose connections problem.
Now switch on the supply.
AUT / MANUAL SWITCH FUNCTI N
AUTO – In AUT mode, Motor N/ FF as per overhead tank & underground tank water
level.
MANUAL – In MANUAL M DE, Motor N/ FF by START/ST P button of the LLC unit.
ABBREVIATI N
H – verhead Tank High Level
L – verhead Tank Low Level
UH – Underground Tank High Level
UL – Underground Tank Low Level
C – Common