Introduction
The SM700 series of cold water meters
are designed to conform to AWWA C700/
C713 specification. The meters are rated at
150psi (10 bar). The meter designation is
indicated on the display facia and the case.
Air or air/water mixtures will typically
have no damaging effect on the internal
components of the meter and air flow
through the meter will not be registered.
Handling and Storage
The meter should be handled with care and
must not be dropped or subjected to impact.
It is recommended the meter be stored
under controlled conditions, preferably at a
temperature between 15°F (–10°C) & 105°F
(+40°C) and kept away from direct sunlight.
The meter should remain boxed, with the
two plastic thread protection caps in place,
until the point of installation. Do not carry
the water meter by the attached cable.
Fitting should be undertaken by
a competent trained installer.
These instructions should be
read and understood before
commencing the installation.
Installation instructions
1. Remove the two plastic thread protection caps before
installation.
2. The meter must be installed with the arrow pointing
in the direction of the water flow.
3. Cut the pipework to the correct size (see Table 1 for
lay length). This is important to prevent tensile loading
across the meter when tightening.
4. Ensure that the pipework is aligned correctly prior to
installation of the meter. Do not use the meter as a
lever to align the pipework in any manner.
5. Ensure that the pipes are flushed and sealing faces
are free from debris and contamination.
6. Fit the meter to the service pipework in accordance
with standard installation practice.
7. Ensure that rubber or fibre sealing washers are fitted
between the pipe and water meter connections.
Where washers are supplied with the meter, these
must be used. Do not use P.T.F.E tape or sealing
paste to provide a water tight seal.
8. Locate the nuts on the pipework onto the meter
threads and screw on finger tight. Care should
be taken to prevent cross threading or stripping of
threads when making the connection.
9. Tighten the nut a further quarter to half a turn
using a wrench. Typical torque 11 ft-lbs min.
to 14.75 ft-lbs max. (15Nm min. to 20Nm max.).
Do not over tighten.
10. If the meter is connected do not solder or make any
solder joints within 8 inches of the meter. If soldering is
undertaken, aim torch away from meter at all times.
11. Ensure the pipework is securely fixed to avoid
vibration or bending across the meter.
12. The meter should be installed away from sources
of heat and out of direct sunlight.
13. The meter installation should be protected
from freezing.
14. The meter can be fitted to horizontal, vertical or
inclined pipework.
15. When water has been turned on check all joints
for signs of leakage.
16. It is recommended to thoroughly purge the entire
water system, including all valves and pumps, of
air prior to recording any reading as required by
the utility.
17. For connection to a remote reading system, see
the manufacturer's instructions and refer to table 2
of these instructions for wire color assignments
when required.
Note: Do not install the communications cable along or
within 6 inches of existing cable runs.
Reading the meter
The reading is displayed on the totalizer module of the
meter under a protective lid. The display digits before
the decimal point, surrounded by a black or both a
black and white border on the facia, represent whole
US gallons (gal.), cubic feet (ft3) or cubic meters (m3)
and the digits after the decimal point, surrounded by
a red border, represent fractions of a gallon, ft3or m3.
When water is flowing a flashing square icon appears
to the lower right of the display, but when the flow has
stopped this indicator will be extinguished.
To read the meter using a remote reading system,
refer to the manufacturer's instructions.
Maintenance requirements
The SM700 series of cold water meters typically
do not require routine maintenance. The water meter
is powered by a 3.6 volt battery. Low battery power
is indicated by the display digits flashing on and off,
at which stage the meter should be replaced. This
should be undertaken within three months.
The SM700 series of cold water meter features
a removable battery pack to allow for disposal
separately to the rest of the meter. For battery pack
removal instructions, please refer to the separate
instructions numbered D-1001-1.
Note: The batteries used in this meter are potentially
hazardous if damaged. Battery disposal should be
undertaken with consideration to any requirements
by law for the disposal of Lithium-thionyl
chloride batteries.
Health & Safety information
In installations where the pipework is part of an
electrical earthing circuit the inlet and outlet pipes
must be connected by a permanently bonded
electrical earth grounding strap.
Note: The battery carries a warning as follows:- Fire,
explosion and severe burn hazard. Do not crush,
recharge, disassemble, heat above 212°F (100°C) or
incinerate. Do not short-circuit.
Contact Information:
United States
Elster AMCO Water, LLC
10 SW 49th Avenue, Building 100
Ocala, FL 34474
T +1 800 874 0890
F +1 352 368 1950
[email protected].com
www.elsteramcowater.com
Due to our policy of continual improvement
we reserve the right to change the specification
without prior notice.
Certified to
NSF/ANSI 61
Note: Only products
bearing the NSF Mark
are certified.
The top of the meter should be clear of any
obstruction to allow for lifting the lid for reading
the meter. The meter should be installed away
from sources of heat & direct sunlight and
protected from freezing.
Figure 1
Figure 11
Figure 6
Table 1
Table 2
Figure 2
Figure 10
The meter can be fitted to horizontal, vertical or
inclined pipework.
Figure 12
Do not carry the water meter by the
attached cable.
Figure 5
Ensure that the pipes are flushed and sealing
faces are free from debris and contamination.
Fit meter between the pipe connections using
rubber or fiber sealing washers. Where
washers are supplied with the meter, these
must be used. Do not use PTFE tape or
sealing paste.
Figure 4
Remove the two thread protection caps. Install
with the arrow pointing in the direction of the
water flow. Cut the pipework to the correct
size. This is important to prevent tensile
loading across the meter when tightening
the flange nuts.
Figure 3
Ensure that the pipework is aligned correctly
prior to installation of the meter. Do not use
the meter as a lever to align the pipework
in any manner.
Figure 7
Securely fix the pipework to avoid vibration or
bending across the meter. When fitting the
pipe supports it is important that both sides of
the pipework are aligned to prevent bending
forces being applied across the meter.
Figure 8
If the meter is connected do not solder or make
any solder joints within 8 in (200 mm) of the
meter connections. If soldering is undertaken,
aim torch away from meter at all times.
Do not allow corrosive chemicals on or near
the meter (i.e. solder flux, aggressive cleaning
products etc.).
Figure 9
When water has been turned on check all
joints for signs of leakage or slight seeping at
the nut to meter interface. Connections must
be watertight. Purge the meter to remove all
air from the pipe and meter.
Locate the nuts on pipework onto the meter
threaded flanges. Screw on finger tight.
Note: care should be taken to prevent cross
threading. Tighten the nuts a further 1/4to 1/2
turn using a wrench, typical torque of 11 ft-lbs
min. to 14.75 ft-lbs max. (15 Nm min. to
20 Nm max.).
AWWA
Meter Size
Meter
Length
Straight Pipe
Connection
Thread
5/8” x 1/2” 7 1/2” 3/4”
5/8” x 3/4” 7 1/2” 1”
3/4” x 3/4" 7 1/2” 1”
3/4” x 3/4" 9” 1”
3/4" x 1” 9” 1 1/4”
1” 10 3/4” 1 1/4”
* Connection polarity unimportant
Any interconnection cables should be joined with a suitable connection to prevent moisure ingress.
Any unused cores of the wire should also be sealed.
Communications type Termination
Function Clock or Data
Request Data Ground
Meter interface cable Red wire Green wire Black wire
WallPad *Screw terminal 1 *Screw terminal 2 Not connected
PitPad Red wire Green wire Not connected
Note: Do not install the communications
cable along or within 6 in (150 mm) of existing
cable runs.
Where an in-line connector is used make sure that
the two mating components are pushed together
fully and locked (where applicable) to ensure correct
connection and seal from moisture. D-0085-10

Other Elster Measuring Instrument manuals

Elster BK-G Series User manual

Elster

Elster BK-G Series User manual

Elster 2 Series Guide

Elster

Elster 2 Series Guide

Elster BK-G1.6 User manual

Elster

Elster BK-G1.6 User manual

Elster 6 Series User manual

Elster

Elster 6 Series User manual

Elster gREX User manual

Elster

Elster gREX User manual

Elster EK260 Specification sheet

Elster

Elster EK260 Specification sheet

Elster F90S User manual

Elster

Elster F90S User manual

Elster gas-lab Q1 Guide

Elster

Elster gas-lab Q1 Guide

Elster F90S User manual

Elster

Elster F90S User manual

Elster A3 ALPHA User manual

Elster

Elster A3 ALPHA User manual

Elster ALPHA A1800 User manual

Elster

Elster ALPHA A1800 User manual

Elster A1100 Installation and operation manual

Elster

Elster A1100 Installation and operation manual

Elster A3 ALPHA User manual

Elster

Elster A3 ALPHA User manual

Elster BK-G1.6 User manual

Elster

Elster BK-G1.6 User manual

Elster F96Plus User manual

Elster

Elster F96Plus User manual

Elster BK-G Series Operation and maintenance manual

Elster

Elster BK-G Series Operation and maintenance manual

Elster Q.Sonic PLUS Instruction manual

Elster

Elster Q.Sonic PLUS Instruction manual

Elster EK280 User manual

Elster

Elster EK280 User manual

Elster A3 ALPHA User manual

Elster

Elster A3 ALPHA User manual

Elster A3 ALPHA User manual

Elster

Elster A3 ALPHA User manual

Elster TC210 Specification sheet

Elster

Elster TC210 Specification sheet

Elster F90M AMS User manual

Elster

Elster F90M AMS User manual

Elster EK280 Instructions for use

Elster

Elster EK280 Instructions for use

Elster themis plus Operating instructions

Elster

Elster themis plus Operating instructions

Popular Measuring Instrument manuals by other brands

Rotronic CF8-D/W-IN installation manual

Rotronic

Rotronic CF8-D/W-IN installation manual

Baumer CleverLevel PL20H/S operating instructions

Baumer

Baumer CleverLevel PL20H/S operating instructions

Pocket Radar HITTING INTO A NET OR CAGE quick start guide

Pocket Radar

Pocket Radar HITTING INTO A NET OR CAGE quick start guide

Solar-Log 2000 installation manual

Solar-Log

Solar-Log 2000 installation manual

IKONIX Associated Research Hypot III Operation and service manual

IKONIX

IKONIX Associated Research Hypot III Operation and service manual

TQ Environmental TQ8000 operating manual

TQ Environmental

TQ Environmental TQ8000 operating manual

Endress+Hauser Prosonic M FMU41 Brief operating instructions

Endress+Hauser

Endress+Hauser Prosonic M FMU41 Brief operating instructions

Anyload OCSD Series Operation manual

Anyload

Anyload OCSD Series Operation manual

SKF 15V-090-00102-200 quick start guide

SKF

SKF 15V-090-00102-200 quick start guide

Blizzard Pocket Rocket II quick start guide

Blizzard

Blizzard Pocket Rocket II quick start guide

Rohde & Schwarz R&S SMBVB-K548 user manual

Rohde & Schwarz

Rohde & Schwarz R&S SMBVB-K548 user manual

Ateg CUB5V quick start guide

Ateg

Ateg CUB5V quick start guide

Bushnell TOUR V4 SHIFT manual

Bushnell

Bushnell TOUR V4 SHIFT manual

Extech Instruments MA610 user manual

Extech Instruments

Extech Instruments MA610 user manual

janitza UMG 605-PRO installation manual

janitza

janitza UMG 605-PRO installation manual

Offel 55-106 M101 user manual

Offel

Offel 55-106 M101 user manual

MR MESSKO MFLOC 2.0 operating instructions

MR

MR MESSKO MFLOC 2.0 operating instructions

East Tester ET1090 user manual

East Tester

East Tester ET1090 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.