Instruction for ELTEX UPG-Stitch
thread break detector for sewing machines
16760
General
The UPG-Stitch is a thread break detector designed to be used on sewing machines.
It checks that the thread is moving in stitches. Both no thread movement and continuous thread movement will
result in an active output.
It operates on the piezoelectric principle, detecting the thread movement.
The ceramic sensor part can be used both as a closed eyelet and an open bar.
The thread must always contact the ceramic bar or eyelet, and the thread motion is detected most effectively when
it deviates about 10-15° as it passes through the sensor.
The LED is on when the thread is moving correctly.
It is flashing steady when the thread is not moving.
It is flashing irregularly when the thread is moving continuously.
Fitting
The UPG-Stitch thread break detector is fitted on the
machine with two screws, maximum diameter 3 mm.
NOTE! Electrical interference caused by insufficient
machine ground can cause the UPG-Stitch to
indicate thread movement when no thread is moving.
This can be corrected by electrically insulating the
UPG-Stitch from the machine frame. Two nylon
screws and an insulation pad can be used to achieve
this. These parts are included with the UPG-Stitch
sensor. These parts can also be ordered from Eltex.
The part numbers are:
#4144 Nylon Screw,
#6868 Insulation pad
Adjustment
If the factory setting of the sensitivity is not suitable, it
can be adjusted with the potentiometer, located
under the lid.
When making adjustments, use a small screw-driver,
maximum size of 2.5 mm.
Minimum setting ( counter clockwise) is for
course, fast moving and/or high-tension thread.
Maximum setting ( clockwise) is for fine, slow
moving, and low-tension thread.
The detector has a cable with a 6/4 modular plug
connector
The output is suitable for PLC or other electronic
control devices. The detectors can be connected in
parallel.
The detector is protected against reversed polarity on
the power supply
Yellow Output A
Green Output B
Red
Power supply (+)
15-33 V DC
Black
Power supply (-)
Output: Optocoupler, NC = normally closed
Output load: max 10mA, 35 V DC
Max ON-STATE voltage drop: 2V DC at 10 mA
PNP
Configured as PNP output for PLC; high when thread
is not moving.
NPN
Configured as NPN open collector output (for input
with pull-up resistor); low when thread is not moving.
Special
Configured as optocoupler output; high when thread
is not moving.
T H
-
0337
-
00
Copyright © 2014 Eltex of Sweden AB
Box 24 • SE-283 21 OSBY • Sweden • Tel.: +46 (0) 479 53 63 00 • Fax: +46 (0) 479 53 63 99
E-mail: info@eltex.se • Web: www.eltex.se
Eltex U.S., Inc.
13031 E. Wade Hampton Blvd.
GREER, South Carolina, 29651, USA
Tel.: +1 864-879-2131
Fax: +1 864-879-3734
[email protected]
Eltex Manufacturing Ltd.
Railway Road
TEMPLEMORE, Co. Tipperary,
Ireland
Tel.: +353 504-314 33
Fax: +353 504-310 02
[email protected]
POLSA-ELTEX, S.L.
Zamora, 103 – entlo 3o
ES-08018 BARCELONA,
Spain
Tel.: +34 93 309 00 17
Fax: +34 93 309 59 45
polsa@infonegocio.com
Eltex China Beijing S&S Electronics
Technology Co., Ltd.
B052 F10, SOHO Nexus Center, No. 19A,
East 3rd ring north Rd., Beijing, China 10020
Tel.: +86 10 57351219
Fax: +86 10 65066468
Email: Chuan.Jian[email protected]
Web: www.eltex.cn
Connection

Other ELTEX Security Sensor manuals

ELTEX UPG-Stitch User manual

ELTEX

ELTEX UPG-Stitch User manual

ELTEX ETM Solo Viewer User manual

ELTEX

ELTEX ETM Solo Viewer User manual

ELTEX UPG 16720 User manual

ELTEX

ELTEX UPG 16720 User manual

Popular Security Sensor manuals by other brands

Shimadzu SPD-40 CL instruction manual

Shimadzu

Shimadzu SPD-40 CL instruction manual

Theben theRonda S360-100 UP WH manual

Theben

Theben theRonda S360-100 UP WH manual

AJAX Systems DoorProtect user manual

AJAX Systems

AJAX Systems DoorProtect user manual

Transmitter Solutions iGAZE iGAZES035 instructions

Transmitter Solutions

Transmitter Solutions iGAZE iGAZES035 instructions

Alula RE209 quick start guide

Alula

Alula RE209 quick start guide

3M Nano-Lok Edge Series instruction manual

3M

3M Nano-Lok Edge Series instruction manual

Industrial Scientific MX6 iBrid Operation guide

Industrial Scientific

Industrial Scientific MX6 iBrid Operation guide

Motorola HMDS1040 - Xanboo Home Monitoring quick start guide

Motorola

Motorola HMDS1040 - Xanboo Home Monitoring quick start guide

Orion EL-55 user manual

Orion

Orion EL-55 user manual

Leak intelligence Leak Gopher LGLPWLD user manual

Leak intelligence

Leak intelligence Leak Gopher LGLPWLD user manual

STEINEL PROFESSIONAL IS 345 PF instructions

STEINEL PROFESSIONAL

STEINEL PROFESSIONAL IS 345 PF instructions

Digital Monitoring Products 1128 installation guide

Digital Monitoring Products

Digital Monitoring Products 1128 installation guide

United Technologies Interlogix RF430I4 Installation sheet

United Technologies

United Technologies Interlogix RF430I4 Installation sheet

Amprobe UAT-620 user manual

Amprobe

Amprobe UAT-620 user manual

Theben compact office EIB installation manual

Theben

Theben compact office EIB installation manual

ESP MAGPRO-HD1 installation instructions

ESP

ESP MAGPRO-HD1 installation instructions

Risco ViTRON RWT6G installation instructions

Risco

Risco ViTRON RWT6G installation instructions

Covidien Nellcor EASYCAP II Instructions for use

Covidien

Covidien Nellcor EASYCAP II Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.