Intrusion Alarm Systems | ISC-SM-90 Seismic detector, 90m²
ISC-SM-90 Seismic detector, 90m²
www.boschsecurity.com
uComplete protection against electrical influences
uRemotely controlled reduction of sensitivity
uPre-alarm - Memory with optical display
uIntegrated test system
uMonitoring of the supply voltage
The seismic detector is used to monitor modular
vaults, vault walls, and safe doors.
Functions
Protection for various devices
The seismic detector provides reliable protection
against different break in-attempts and can be used
for these devices:
• safes
• automatic cash dispensers
• night deposit boxes
• light-weight safes (LWS)
• vaults
• steel/concrete modular strong-rooms
Detection of various break-in methods
The seismic detector detects the following break-in
tools and methods:
• diamante core drills
• hydraulic press tools
• oxygen lances
• explosives
Double-housing
The seismic detector is equipped with a double
housing. The double-housing protects the detector
against electromagnetic interference and accidental or
deliberate damage.
Custom-set sensitivity
The seismic detector offers intelligent signal
processing to custom-set the level of detection
sensitivity. This reduces the risk of false alarms.
Notice
Losing VdS conformity
If the sensitivity is reduced, the conformity of the
relevant VdS regulations in the system context
must be checked or accepted by the VdS.
Installation/configuration notes
Coverage area
The area monitored by the detector is called the
coverage area. It covers the area around the detector
with an operating radius.
The coverage area is strongly dependent on the
material of the object to be monitored. Based on
practical experience, an effective radius of r = 5 m
applies to steel and iron-reinforced concrete.
F
r =
F =
r
r= 3
/
4
r= 4
/
4
r = 5m
2
1
1 Operating radius
2 Coverage area
Ideal coverage area
To achieve the ideal coverage, do the following:
• Install one detector for each plane (walls, floor, and
ceiling) of the protected area.
• Do not add the coverage from adjoining planes to the
comprehensive protection strategy.
Coverage area reduction
The operating radius and the coverage area can be
reduced by:
• Tightly sealed corners and edges
• Incorrect positioning
• Interstices
Parts included
Quanti
ty
Component
1Seismic detector
1 Drilling template
3 Cable tie
Technical specifications
Electrical
Minimum operating voltage in
VDC
8
Maximum operating voltage in
VDC
16
Minimum current consumption in
mA
2.5
Maximum current consumption in
mA
3.5
Alarm current consumption in mA 5
Terminals
Alarm outputs, terminals 14, 15
Semiconductor relay Opens on alarm and low voltage
Contact load in VDC/100 mA 30, ohmic load
Minimum series resistance in Ω 45
Alarm holding time in seconds 2.5
Electronic alarm output, terminal 12
Open collector alarm in VDC 0
Minimum short circuit strength in
VDC
16
Tamper surveillance, terminals 10, 11
Microswitch, cover and floor Opens on sabotage
Contact load in VDC/100 mA 30
Anti-drilling foil in cover Alarm when tamper
Test input, terminal 4
Low voltage in V <1.5
High voltage in VDC >3.5
Remote input, terminal 7
Low voltage in V <1.5
High voltage in VDC >3.5
Mechanical
Dimension in cm (H x W x D) 8.9 x 8.9 x 2.3
Color White
Environmental
Minimum operating temperature
in °C
-40
Maximum operating temperature
in °C
+70
2| ISC-SM-90 Seismic detector, 90m²
Minimum storage temperature in
°C
-40
Maximum storage temperature in
°C
+70
Maximum relative humidity in % 95
Ordering information
ISC-SM-90 Seismic detector, 90m²
Seismic detector, used to monitor modular vaults,
vault walls, and safe doors
Order number ISC-SM-90
Accessories
ISN-GMX-P0 Mounting plate for seismic detector
Mounting plate for seismic detectors. Suitable for
mounting seismic detectors to steel or concrete
surfaces.
Order number ISN-GMX-P0
ISN-GMX-B0 Floor box for seismic detector
Floor box for mounting a seismic detector.
Order number ISN-GMX-B0
ISN-GMX-S1 Test transmitter
Test transmitter for installation under a seismic
detector. Checks the detector and the physical contact
between the detector and the protected object.
Order number ISN-GMX-S1
3| ISC-SM-90 Seismic detector, 90m²
Represented by:
Europe, Middle East, Africa: Germany: North America: Asia-Pacific:
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven, The Netherlands
Phone: + 31 40 2577 284
[email protected]
emea.boschsecurity.com
Bosch Sicherheitssysteme GmbH
Robert-Bosch-Ring 5
85630 Grasbrunn
Germany
www.boschsecurity.com
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
[email protected]
www.boschsecurity.us
Robert Bosch (SEA) Pte Ltd, Security Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
[email protected]
www.boschsecurity.asia
© Bosch Security Systems 2019 | Data subject to change without notice
1419629579 | en, V14, 13. Mar 2019

Other manuals for ISC-SM-90

1

Other Bosch Security Sensor manuals

Bosch ISP-PPR1-WA16x User manual

Bosch

Bosch ISP-PPR1-WA16x User manual

Bosch Professional Series User manual

Bosch

Bosch Professional Series User manual

Bosch ISC-PPR1-WA16G User manual

Bosch

Bosch ISC-PPR1-WA16G User manual

Bosch DS820i Series User manual

Bosch

Bosch DS820i Series User manual

Bosch RADION Life Safety User manual

Bosch

Bosch RADION Life Safety User manual

Bosch PROFESSIONAL wallSCANNER D-TECT 100 concrete User manual

Bosch

Bosch PROFESSIONAL wallSCANNER D-TECT 100 concrete User manual

Bosch D-tect 150 User manual

Bosch

Bosch D-tect 150 User manual

Bosch ISP-SM90-120 User manual

Bosch

Bosch ISP-SM90-120 User manual

Bosch DS940 User manual

Bosch

Bosch DS940 User manual

Bosch ISC-BPR2-W12 User manual

Bosch

Bosch ISC-BPR2-W12 User manual

Bosch ISC-BDL2-WP12 User manual

Bosch

Bosch ISC-BDL2-WP12 User manual

Bosch WEU PDO 6 User manual

Bosch

Bosch WEU PDO 6 User manual

Bosch BMA400 Instruction Manual

Bosch

Bosch BMA400 Instruction Manual

Bosch ISW-EN1262 User manual

Bosch

Bosch ISW-EN1262 User manual

Bosch D-tect 120 Professional User manual

Bosch

Bosch D-tect 120 Professional User manual

Bosch TriTech+ ISC-PDL1-WA18G User manual

Bosch

Bosch TriTech+ ISC-PDL1-WA18G User manual

Bosch 440 Series User manual

Bosch

Bosch 440 Series User manual

Bosch GMS 120 Professional User manual

Bosch

Bosch GMS 120 Professional User manual

Bosch DS820 Safety guide

Bosch

Bosch DS820 Safety guide

Bosch Blue Line Q1 User manual

Bosch

Bosch Blue Line Q1 User manual

Bosch Blue Line Gen2 ISC-BPR2 User manual

Bosch

Bosch Blue Line Gen2 ISC-BPR2 User manual

Bosch RADION contact SM User manual

Bosch

Bosch RADION contact SM User manual

Bosch FCP-O 500 User manual

Bosch

Bosch FCP-O 500 User manual

Bosch D603 User manual

Bosch

Bosch D603 User manual

Popular Security Sensor manuals by other brands

logika WL-ZSPWBPWBPW-PI11-04 product manual

logika

logika WL-ZSPWBPWBPW-PI11-04 product manual

Vision ZP3102MY-5 Installation & operation manual

Vision

Vision ZP3102MY-5 Installation & operation manual

Response Alarms CA2000P Installation and operating instructions

Response Alarms

Response Alarms CA2000P Installation and operating instructions

GE Interlogix ARITECH 1500 Series Installation and maintenance guide

GE

GE Interlogix ARITECH 1500 Series Installation and maintenance guide

IMSA FeneGuard installation guide

IMSA

IMSA FeneGuard installation guide

GJD D-TECT 3 IP GJD260 manual

GJD

GJD D-TECT 3 IP GJD260 manual

GEZE SecuLogic RWS TZ 300 System Documentation

GEZE

GEZE SecuLogic RWS TZ 300 System Documentation

Powerfix Profi KH 2927-2 operating instructions

Powerfix Profi

Powerfix Profi KH 2927-2 operating instructions

Ansul SharpEye 20/20MI-32-S-F User and maintenance manual

Ansul

Ansul SharpEye 20/20MI-32-S-F User and maintenance manual

APRVTIO WJL-6000 instructions

APRVTIO

APRVTIO WJL-6000 instructions

GD Import 084474 quick start guide

GD Import

GD Import 084474 quick start guide

jablotron JA-87P quick start guide

jablotron

jablotron JA-87P quick start guide

SGB DLR-2 Series Documentation

SGB

SGB DLR-2 Series Documentation

HOGERT HT4M340 user manual

HOGERT

HOGERT HT4M340 user manual

IFM PN7191 operating instructions

IFM

IFM PN7191 operating instructions

GCE SAFE-GUARD-5 Instructions for use

GCE

GCE SAFE-GUARD-5 Instructions for use

Commercial Electric LM2n400042WNGTH Use and care guide

Commercial Electric

Commercial Electric LM2n400042WNGTH Use and care guide

LST ASA-45681-210 Specification sheet

LST

LST ASA-45681-210 Specification sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.