messages. The red LED on the detector will illuminate
if a fire alarm is reported. The detector has three
sensitivity levels. The factory default sensitivity is
Level 1. The address and sensitivity can be read and
changed using P-9910B Programmer. Please refer to
P-9910B Hand Held Programmer Operation Manual
for details.
Specification
Operating Voltage Loop voltage: 24V
Operating Current Standby current ≤2mA
Action current ≤2.5mA
Power-up Time ≤5s
Indicator Red. It flashes when polling,
and illuminates steadily in
alarm.
Wiring Two wire connection with
FACP, polarity-insensitive.
Programming Mode Electronic programming.
Occupying one loop
address.
Address Range 1~242
Spectrum Response
Range
185nm~260nm
Detection Angle
Detection Distance※25m for Level I, 17m for
Level II and 12m for Level III.
Ingress Protection IP66
Ambient Temperature -20℃~+40℃
Relative Humidity ≤95%RH, non-condensing
Dimensions 147mm×103mm×92mm
Material and Color ZL102 Aluminum alloy,
silvery grey.
Weight 1.5kg
Installation Hole
Spacing
110mm×72mm
Explosion-proof Mark Ex d CT6Ⅱ
Explosion-proof
certificate
CE061027
Standards to comply
with in design
EN 54-10
GB 3836.1 GB 3836.2
IEC 60079-0 IEC 60079-1
※ Test fire: The flame generated by 2000g of
alcohol in a container with bottom area 33cm×33cm
and height 5cm.
Accessories and Tools
Maintenance
1 The detector shall be cleaned at lease once a year
to ensure normal operation of the system.
2 Before testing, notify the proper authorities that the
system is undergoing maintenance and will
temporarily be out of service. Disable the zone or
system undergoing maintenance to avoid
unwanted alarms.
3 The detector shall be tested after cleaned and
re-installed. After testing, notify the proper
authorities the system is back in operation.
Limited Warranty
GST warrants that the product will be free from defects
in design, materials and workmanship during the
warranty period. This warranty shall not apply to any
product that is found to have been improperly installed
or used in any way not in accordance with the
instructions supplied with the product. Anybody,
including the agents, distributors or employees, is not
in the position to amend the contents of this warranty.
Please contact your local distributor for products not
covered by this warranty.
Name and Model Qty. Remarks
P-9910B Hand Held
Programmer 1 Please order
separately
Expansion Bolt M6×60 3
Screws M3×16 2
GST China
Gulf Security Technology Co., Ltd.
No. 80, Changjiang East Road,
QETDZ, Qinhuangdao, Hebei,
P. R. China 066004
Tel: +86 (0) 335 8502528
Fax: +86 (0) 335 8508942
www.
st.com.cn
GST UK
Global System Technology PLC
Lion Court, Staunton Harold Hall,
Melbourne Road, Ashby de la Zouch,
Leicestershire, England LE65 1RT
Tel: +44 1283 225 478
Fax: +44 1283 220 690
www.
st.uk.com
GST Dubai
Global System Technology PLC
PO Box 17998 Unit ZA04
JEBEL ALI Free Zone,
Dubai, UAE
Tel: +971 (0) 4 8833050
Fax: +971 (0) 4 8833053
www.gst.uk.com
This document is subject to change without notice. Please contact GST for more information or questions.