Elumen8 Windstorm DMX Fan User manual

Order code: ELUM077
Windstorm DMX Fan
User Manual

www.prolight.co.uk Windstorm DMX Fan User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablemainssupplyvoltageis
between100~240VAC,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProlight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• Thisxtureisforprofessionaluseonly-itisnotdesigned
fororsuitableforhouseholduse.Theproductmustbe
installedbyaqualiedtechnicianinaccordancewithlocal
territoryregulations.Thesafetyoftheinstallationisthe
responsibilityoftheinstaller.Thexturepresentsrisksof
severeinjuryordeathduetorehazards,electricshock
andfalls.
• Caution!Neverputhandsorobjectsthroughtheprotective
grille,thiscancauseariskofinjury!Peoplewithlonghair
shouldtakespecialcareaslonghaircangetcaughtinthe
fanandresultinseriousinjury!Pleaseensurethataircan
besuckedinfreely.Makesurethatnodirt,sand,clothing
orsimilarcangetsuckedin.
• WARRANTY:Twoyearsfromdateofpurchase.
CAUTION!
KEEP THIS
EQUIPMENT AWAY
FROM RAIN,
MOISTURE
AND LIQUIDS
CAUTION! TAKE
CARE USING THIS
EQUIPMENT! HIGH
VOLTAGE-RISK
OF ELECTRIC
SHOCK
CAUTION!
ROTATING FAN
BLADES CAN
CAUSE SEVERE
INJURY! KEEP
HANDS CLEAR!

www.prolight.co.uk Windstorm DMX Fan User Manual
3
Product overview & technical specications
Highoutputwindmachineforuseinclubs,concertvenuesandonstages.Thewindoutputcanbeadjustedfroma
lightbreezetoastronggaleatonepercentincrementsviatheon-boardcontrolsorDMX.Themachineissupplied
with2bracketsforeithertrusshangingorfreestandingapplications.
•Fandiameter:310mm
•Max.airow55m³/min
•Noise:83dB@2m(fulloutput)
•DMXchannels:1
•Manualmodeadjustablein1%increments
viamenusystemorpotentiometer
•Tilt:360°
•Bracketsallowformultiplerigging
oroorstandingapplications
•4pushbuttonmenuwithLEDdisplay
•PowerCONinput/output
•5-PinXLRinput/output
Windstorm DMX Fan
Specications Windstorm DMX Fan
Powerconsumption 185W
Powersupply 240V,50Hz
Fuse F2A250V
Dimensions 505x472x425mm
Weight 7.8kg
Ordercode ELUM077
505mm
472mm 425mm

www.prolight.co.uk Windstorm DMX Fan User Manual
4
Technical specications
01-Earthpoint
02-LEDdisplay
03-Functionbuttons
04-5-PinDMXinput
05-5-PinDMXoutput
06-PowerCONinput
07-FuseF2A250V
08-Rotaryspeedcontrol
Inthebox:1 x xture,
1 x power cable,
1 x user manual,
1 x oor standing bracket
& 1 x truss mount bracket
MENU ENTERDOWNUP
Windstorm
FUSE:
F2A 250V
POWER INPUT:
240V~50Hz
SPEED
ADJUSTMENT
LOW HIGH
CAUTION!
DO NOT INSERT YOUR HANDS
OR OBJECTS INTO THE FAN!
Windstorm
DMX INPUTDMX OUTPUT
www.prolight.co.uk
07 06 08
03
05
04
01
02

www.prolight.co.uk Windstorm DMX Fan User Manual
5
Operating instructions
S P e d
000
099
Manual fan speed
A d d r
A 0 0 1
A 5 1 2
DMX address setting
ver v 0 0 1
Software version
Hold last setting
b L N d h o L d
oFF
o n
Fan on
Fan off
LED display
d I S p
1 0 o F
3 0 o F
6 0 o F
o n
DMX mode:
OperatinginaDMXcontrolmodeenvironmentgivestheuserthegreatestexibilitywhenitcomesto
customisingorcreatingashow.Inthismodeyouwillbeabletocontroleachindividualtraitofthexture
andeachxtureindependently.
ToaccesstheDMXaddressmode,pressthe“MENU”buttononthefrontoftheunittoshowAddr
ontheLEDdisplay.Nowpressthe“ENTER”buttonandusethe“UP”and“DOWN”buttonstosetthe
requiredDMXaddress.Pressthe“ENTER”buttontoconrmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.
Channel Value Function
1 000-255 Fanspeed(slow-fast)
1 channel mode:
Manual fan speed mode:
Toaccessthemanualfanspeedmode,pressthe“MENU”buttononthefrontoftheunittoshow
SPedontheLEDdisplay.Pressthe“ENTER”buttonandusetherotarycontroltoadjustthefanspeed
from000from099.
Toexitoutofanyoftheaboveoptions,pressthe“MENU”button.

www.prolight.co.uk Windstorm DMX Fan User Manual
6
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-511.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Note: DMX cable must be daisy chained and cannot be split.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

www.prolight.co.uk Windstorm DMX Fan User Manual
7
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL90, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterference.Itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup

www.prolight.co.uk Windstorm DMX Fan User Manual
8
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposed
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.
Table of contents
Popular Fan manuals by other brands

Monte Carlo Fan Company
Monte Carlo Fan Company 5VL52 Series owner's manual

RHYTHM
RHYTHM 9ZF031RH08 instruction manual

Aero
Aero Enviro DC Installation & user manual

kuzco lighting
kuzco lighting FREMONT instruction sheet

Vortice
Vortice PENTA ES EP Instruction booklet

Dru
Dru LUX LIGNUM Instructions for installation

Somogyi Elektronic
Somogyi Elektronic PVR 45 instruction manual

Premium levella
Premium levella PFT424R user manual

Hunter
Hunter 20807 Parts guide

Westinghouse
Westinghouse WSRF807BK instruction manual

Whirlpool
Whirlpool UXD8636DYS user manual

Panasonic
Panasonic F-M15E6 Operating installation and instructions