EMC CG 100 User manual

1F, No.8, Lane38,Wensan 3rd street,, Kwei Shan Dist, Taoyuan City, Taiwan
TEL : 03-3286-998 FAX : 03-3288-376 http://www.emci.com.tw
2
1. Introduction
The CG 100/500 is a comb generator, it has been developed to provide a means of quickly and
very easily checking the accuracy of EMC conducted emission test systems.
Key features
• Small size… battery powered.
• Simple operation…simply connect to the EUT port and switch on.
• USB charging.
• Can be used with any standard mains output socket, via adaptors.

1F, No.8, Lane38,Wensan 3rd street,, Kwei Shan Dist, Taoyuan City, Taiwan
TEL : 03-3286-998 FAX : 03-3288-376 http://www.emci.com.tw
3
2. Shipping list
1
CG 100/500 unit
2
Earth bonding cable
3
Charger adapter, CE eligibility criteria
4
USB Cable
5
Operation Manual
6
Wooden storage box
Figure 2-1 CG-100/500 Comb Generator and Accessories

1F, No.8, Lane38,Wensan 3rd street,, Kwei Shan Dist, Taoyuan City, Taiwan
TEL : 03-3286-998 FAX : 03-3288-376 http://www.emci.com.tw
4
3. Specification
3.1 Electrical Specifications
Frequency range
100kHz~400MHz
Frequency step size
100kHz/500kHz Switchable
Maximum Mains Voltage range of LISN
240Vdc or 240Vac, 60Hz
Output socket-1
IEC 320-C14 AC Power Inlet
Output socket-2
RJ45
Output socket-3
RJ11
3.2 Battery and Charger
Battery type
Lithium-ion Rechargeable battery
Battery Capacity
3.6V/6000mAh
Charging input
DC 5V/500mA
Charging Time
8-10 Hours
Usage time
16 Hours
Charging Connector
Mini USB Socket
Charger Adapter
Input: 100-240Vac/50-60Hz, 0.3A
Output: 5Vdc, 1Amax
3.3 Physical Specifications
Length
120mm
Wide
82mm
Height
85mm
Weight
1100g

1F, No.8, Lane38,Wensan 3rd street,, Kwei Shan Dist, Taoyuan City, Taiwan
TEL : 03-3286-998 FAX : 03-3288-376 http://www.emci.com.tw
5
4. Overview
Front and Top panel:
Item
Description
Frequency step switch
Select frequency step 100kHz or 500kHz
Power switch
Turn on or off CG100/500
LED indicator
Battery status indicator
Mini USB connector
For Charge input (5Vdc)
Frequency step select Switch
Power ON/OFF Switch
LED indicator
Charger connector

1F, No.8, Lane38,Wensan 3rd street,, Kwei Shan Dist, Taoyuan City, Taiwan
TEL : 03-3286-998 FAX : 03-3288-376 http://www.emci.com.tw
6
Right panel:
AC socket
Generator output, connect to LISN
Ground stud
Ground point, connect to Safety earth ground.
Left panel:
RJ-45 socket
Generator output, connect to ISN for T4&T8
RJ-11 socket
Generator output, connect to ISN for T2
AC socket
Ground stud
RJ45 connector
RJ11 connector

1F, No.8, Lane38,Wensan 3rd street,, Kwei Shan Dist, Taoyuan City, Taiwan
TEL : 03-3286-998 FAX : 03-3288-376 http://www.emci.com.tw
7
5. Operation
5.1 Battery charging
Before use the CG100/500, please make sure the internal battery has been charged,
And the batteries completely charge is suggested.
During charging, the Power switch shall be in the OFF position!
The charger input of CG100/500 does not exceed 5.2Vdc.
5.2 General operation
5.2.1 Power On Switch
The switch turns the unit power on or off.
5.2.2 Power On Indicator
When the Power On indicator LED is lit the Comb Generator is ready for use.
3 LEDs lit, the battery level is 70~100%
2 LEDs lit, the battery level is 40~70%
1 LED lit, the battery level is 20~40%
If only one LED lit when power on, the battery level is 20~40%, please recharge
the CG100/500 unit. When all LEDs are dark at power on, that means critical low
battery, and must recharge the CG100/500 unit right now.
The LED will be flashing when the CG100/500 in charging status, and will all lit
when the battery is completely charged.
CAUTION
CAUTION

1F, No.8, Lane38,Wensan 3rd street,, Kwei Shan Dist, Taoyuan City, Taiwan
TEL : 03-3286-998 FAX : 03-3288-376 http://www.emci.com.tw
8
5.2.3 Connection with LISN
1. Connect an earth bonding wire from the earth stud on the CG100/500 to a
reliable earth point, ensuring a good connection.
2. Connect the supplied Power cord from the AC socket on the CG100/500 to
the mains EUT outlet on the LISN.
Ensure the connections to the receiver/analyzer are as used for measuring the
EUT, with any pre-amplifiers and/or transient limiters switched on.
5.2.4 Connection with ISN
1. Connect an earth bonding wire from the earth stud on the CG100/500 to a
reliable earth point, ensuring a good connection.
2. Connect the RJ-11 or RJ-45 cable from the RJ11/RJ45 connector on
CG100/500 to the RJ11/RJ45 connector on EUT port of ISN.
5.2.5 Recommends of site validation
The CG100/500 Comb generator can be used to validate test site or used to daily
check. In order to minimize the measure deviation, the same setup installation at
each test is in need, and the follow items have to be considered.
1. The same position and orientation of CG100/500.
2. The same cable placement, include Power cord, ground wire, RJ11 and RJ45
cables.
3. The same cable length, it would be best to use the same cable for each test.
4. Ground connection point must be connect to the same point for each test and
has good connection.
This manual suits for next models
1
Table of contents
Popular Inverter manuals by other brands

Generac Power Systems
Generac Power Systems GUARDIAN 04136-0 owner's manual

Trina Solar
Trina Solar TSM-DA01A.05 installation manual

Mecc Alte
Mecc Alte BTO3-N Series Operating and maintenance instructions

Mitsubishi
Mitsubishi FR-A500 Series instruction manual

Kaysun
Kaysun KSDF-28 DN4.0 installation manual

Generac Power Systems
Generac Power Systems 004703-1 owner's manual