C6.1.6/0117-1017/E
2.14 Pump-down –General................................................................................................... 23
2.14.1 External pump-down –Without XCM25D integration (not available on ZXDE units)
............................................................................................................................ 23
2.14.2 Pump-down by the unit controller (not available on ZXDE units) ...................... 23
2.14.3 Pump-down with room thermostat (not available on ZXDE units) ..................... 24
2.14.4 Internal pump-down with temperature sensor (case temperature).................... 25
2.15 Reset to factory settings –Emerson "Hot Key" ............................................................. 26
2.15.1 How to save factory settings or user settings .................................................... 26
2.15.2 Applicable hot key for ZX units with XCM25D controller.................................... 26
2.15.3 Location of the "Hot Key" plug connection on the XCM25D controller .............. 26
2.15.4 How to program a "Hot Key" from the controller (upload).................................. 26
2.15.5 How to program a controller using an Emerson "Hot Key" (download) ............. 27
2.16 Troubleshooting –Alarm history.................................................................................... 27
2.17 Compressor motor protection ........................................................................................ 28
2.18 System pressure protection........................................................................................... 28
2.18.1 High-pressure safety switch............................................................................... 28
2.18.2 High pressure: pressure relief valve................................................................... 28
2.18.3 Low-pressure safety switch –Optional .............................................................. 28
2.19 Other inputs of the XCM25D controller.......................................................................... 28
2.19.1 Customer-supplied control (room thermostat).................................................... 28
2.19.2 Case temperature controller............................................................................... 28
2.19.3 Ambient temperature sensor.............................................................................. 28
2.20 Output of the XCM25D controller –Alarm output (DO5)............................................... 29
2.21 Dimensions in mm ......................................................................................................... 29
3Installation......................................................................................................30
3.1 Condensing unit handling .............................................................................................. 30
3.1.1 Transport and storage........................................................................................ 30
3.1.2 Weights............................................................................................................... 30
3.2 Electrical connection...................................................................................................... 31
3.2.1 Power supply connections.................................................................................. 31
3.2.2 Maximum operating currents for cable selection ............................................... 31
3.2.3 Electrical wiring .................................................................................................. 31
3.2.4 Electrical protection standard (protection class) ................................................ 32
3.2.5 Main fuses.......................................................................................................... 32
3.3 Refrigeration piping connections ................................................................................... 32
3.3.1 Refrigeration piping installation.......................................................................... 32
3.3.2 Brazing recommendations.................................................................................. 33
3.3.3 Brazing procedure.............................................................................................. 34
3.4 Location & fixings........................................................................................................... 34
3.5 Required distances ........................................................................................................ 35
4Starting up & operation..................................................................................36