ZONE
+ -
TX
RADIO
WD
RESET
HELP
RX
ON
12345678
BACK
POWER
FAULT
ISOLATE
SCR
+
-
LOOP IN
SCR
LOOP OUT
+
-
12 3 4 5 6 7
3V3
TX
RX
0V
OUTPUT 2OUTPUT 1
3VDC SETRST
INPUT1 INPUT2
LED
ENABLE
POWER
INPUT 1
INPUT 2
FAULT
CLOSED
01
1
64
F-SAFE
N/OCOM N/C
SERIALNO
LOGON
IP- IP+IP- IP+
3VDC SETRST N/OCOMN/C
EXPAN1EXPAN2
RELAYON
RELAYON
2
4
8
16
32
ANTENNA
KEEPCABLES AWAY FROM THIS AREA
SOUNDERFAULT ZONE
EOL L1L2EOL L1 L2 ALARM
RES
EOL L1L2
(+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-)
SOUNDERS FAULT ZONE/RESET
EOL L1 L2 EOL L1 L2 ALARM
RES
EOL L1 L2
(+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-)
LOOP IN
24V OUT
- +
SOUNDER
+ -
13
2
+ -
6 Connection wiring continued 6 Connection wiring continued
Specication Regulatory information
©2022 EMS Ltd. All rights reserved. Page 2 of 2 TSD147-99 Issue 7 21/06/2022 AJM
Option 1
Wired to provide fault
notication on the
conventional re panel’s
SOUNDER CIRCUIT
Operating temperature -10 to +55 °C
Storage temperature 5 to 30 °C
Humidity 0 to 95% non-condensing
Supply Powered from the zone interface monitor
Current drawn from
connected panel (max.) 6 mA
Voltage (max.) 50 VDC
IP rating IP65
(when tted inside zone interface monitor)
Dimensions (W x H x D) 120 x 240 x 60 mm
Weight 0.95 kg
Location Type A: For indoor use
Manufacturer
Year of manufacture
Certication
Certication body
CPR DoP
Approved to
European Union
Directives
0359-CPR-00436
EN54-18:2005. Fire detection and re alarm systems.
Part 18:Input/output devices.
EMS declares that this device is in compliance with Directive
2014/53/EU. The full text of the EU declaration of conformity
is available at the following internet address: www.
emsgroup.co.uk
2012/19/EU (WEEE directive): Products marked with this
symbol cannot be disposed of as unsorted municipal waste
in the European Union. For proper recycling, return this
product to your local supplier upon purchase of equivalent
new equipment, or dispose of it at designated collection
points. For more information see www.recyclethis.info
Dispose of your batteries in an environmentally friendly
manner according to your local regulations.
Carrier Manufacturing Poland Sp. z o.o.
Ul. Kolejowa 24. 39-100 Ropczyce, Poland
See devices serial number label
0905
14
Zone interface monitor (ZIM)
with conventional interface
card (CIC) tted
Wireless
zone monitor
(WZM)
Conventional re panel
1= Sounder circuit EOL resistor
2= Alarm triggering resistor
3= Zone circuit EOL resistor
TX
RADIO
WD
RESET
HELP
RX
ON
12345678
BACK
POWER
FAULT
ISOLATE
SCR
+
-
LOOP IN
SCR
LOOP OUT
+
-
12 3 4 5 6 7
3V3
TX
RX
0V
+ -
OUTPUT 2OUTPUT 1
3VDC SETRST
INPUT1 INPUT2
LED
ENABLE
POWER
INPUT 1
INPUT 2
FAULT
CLOSED
01
1
64
F-SAFE
N/OCOMN/C
SERIALNO
LOGON
IP- IP+ IP- IP+
3VDCSET RST N/OCOMN/C
EXPAN1 EXPAN2
RELAYON
RELAYON
2
4
8
16
32
ANTENNA
KEEPCABLES AWAY FROM THIS AREA
SOUNDERFAULT ZONE
EOL L1L2 EOL L1L2 ALARM
RES
EOLL1L2
(+) (-)(+) (-)(+) (-) (+) (-) (+) (-)(+) (-)(+) (-)
SOUNDERS FAULT ZONE/RESET
EOL L1 L2 EOL L1 L2 ALARM
RES
EOL L1 L2
(+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-) (+) (-)
24V OUT
- +
SOUNDER
+ -
ZONE
+ -
13
2
LOOP IN
Option 2
Wired to provide fault
notication on the
conventional re panel’s
ZONE CIRCUIT
Zone interface monitor (ZIM)
with conventional interface
card (CIC) tted
Wireless
zone monitor
(WZM)
Conventional re panel
1= Sounder circuit EOL resistor
2= Zone circuit EOL resistor
3= Alarm triggering resistor