ORDER CODE
Thank you for choosing series Solid State RelaysENDA EPDA1 / EPAA1
EP D A 1 - 2 25 Z
* 12-25-40-50-70-100-120A AC load current.
* 280-480 AC load voltage.
* 8-30V AC/DC or 90-240V AC input voltage.
* LED status indicator for input voltage.
* Zero-cross switching.
* Applicable for three phase loads.
* Built-in varistor protection.
* Panel mountable.
* CE marked according to European Norms .
Product Basic Code
Panel type SSR
Input voltage
8-30V AC/DC
90-240V AC
Load voltage
AC
EP
D
A
A
THERMAL SPECIFICA TIONS
INPUT
TjJunction temperature (°C)
(j-c)Junction-case thermal resistance (°C/W)
(j-a)Junction-ambient thermal resistance (°C/W)
Rth
Rth
EPDA1-xxxZ
8 - 30Vac/dc
> 6Vac/dc
< 2Vac/dc
< 17mAac/10mAdc
xMa imum ½ Period
Maximum ½ Period
EPAA1-xxxZ
90 - 240Vac
> 75Vac
< 6Vac
< 8mAac
xMa imum 1 Period
Maximum 2 Period
Input voltage
Pick-up voltage
Drop-out voltage
Input current
Turn-on time
Turn-off time
Switching
Zero crossing Z
ENVIRONMENT AL CONDITIONS
-25... +60 C / -30... +100 C (In the environment icing and condensation should not be.)° °
At +4 ° %50, temperature was reduced at +2 ° 90 .%
2
II
Max. 1000m
IP20 According to EN60529
0 C 0C could be (Condensation should not be.)
Ambient-storage temperature
Relative humidity
Pollution degree
Overvoltage category
Altitude
Protection
LED indicator If the input voltage >6V ac/dc, LED lights up. If the input voltage >75V ac, LED lights up.
Order code
EPDA1-E-100520191. / 2
2500Vrms between I/O terminals for 1 min.
For power line max. 2,2Nm, for signal line max. 1,2Nm.
EN 60947-4-3
For power line 16mm² (with cable terminal 25mm² ) cable, for signal line 4mm² cable can be connected.
For EPxA1-2xx/4xxZ 95g , For EPxA1-550/570Z 110g , For EPxA1-5100/5120Z 115g (After packaging)
Order code
Isolation voltage
Connection
Mounting
Enclosure material
Dimensions
Weight
GENERAL
With M4 screws is mounted to the panel .
Self extinguishing plastics ( . ( EN 60695-11-10 V-O)According to
W45xH62xD31mm
EPxA1-xxxZ
Terminal screw torque
Load voltage
24-280V AC
50-480V AC
2
4
Pole number
Single-pole 1
Product standard
ENDA EPDA1 / EPAA1 Panel Mountable Solid State Relays
1,2
20
0,7
20
1,2
20
1,0
20
0,6
20
0,4
20
0,3
20
0,25
20
Do not use the device in locations subject to corrosive and flammable gases.
While cleaning the device, solvents (thinner , benzine, acid etc.) or corrosive materials must not be used .
12A AC
25A AC
40A AC
50A AC
70A AC
100A AC
120A AC
12
25
40
50
70
100
120
Load current
OUTPUT
Order Code
Load curent, AC51/25ºC (Arms)
Load voltage (Vrms)
Overload current t=1s/25°C (Arms)
Non rep.surge current/25°C (Arms)
On-state voltage drop (Vrms)
Leakage current (mArms)
I²t For fusing t=10ms (A²s)
Frequency (Hz)
Minimum operating current (mArms)
EPxA1-212Z
12
50
120
EPxA1-225Z
25
85
250
EPxA1-240Z
40
150
400
880
24 - 280
1,6
5
50 - 60
EPxA1-425Z
25
70
190
265
1,8
8
50 - 60
EPxA1-440Z
EPxA1-450Z
50
380
720
50 - 60
50 - 480
150 360 720
900 1800
EPxA1-470Z EPxA1-4100Z EPxA1-4120Z
110
40
610
290
10 15 20
4000 16200
160 200 300 400 500
78 340
70 120
1,8
540
1350
20
9100
500
100
Read this document carefully before using this device. The guarantee will be expired by damaging of the
device if you don't attend to the directions in the user manual. Also we don't accept any compensations for
personal injury, material damage or capital disadvantages.
english