Endress+Hauser SWA70 User manual

Products Solutions Services
Safety Instructions
WirelessHART adapter SWA70
4-20 mA HART
ATEX, IECEx: Ex ia IIC Gb
Ex tb [ia] IIIC Db
0
XA01366F-C/00/EN/
04.20
71530407
2021-06-07


WirelessHART adapter SWA70 XA01366F-C
Endress+Hauser 3
WirelessHART adapter SWA70
4-20 mA HART
Table of contents
About this document .............................................. 4
Associated documentation ......................................... 4
Supplementary documentation ..................................... 4
Manufacturer's certificates ......................................... 4
Manufacturer address ............................................. 5
Other standards ................................................... 5
Extended order code ............................................... 5
Safety instructions: General ........................................ 7
Safety instructions: Special conditions .............................. 7
Safety instructions: Installation .................................... 8
Safety instructions: Zone 1 ......................................... 9
Safety instructions: Zone 21 ........................................ 9
Safety instructions: Battery ........................................ 9
Temperature tables .............................................. 10
Connection data ................................................. 10

XA01366F-C WirelessHART adapter SWA70
4 Endress+Hauser
About this
document
This document has been translated into several languages. Legally
determined is solely the English source text.
The document translated into EU languages is available:
• In the download area of the Endress+Hauser website:
www.endress.com -> Downloads -> Manuals and Datasheets ->
Type: Ex Safety Instruction (XA) -> Text Search: …
• In the Device Viewer: www.endress.com -> Product tools ->
Access device specific information -> Check device features
If not yet available, the document can be ordered.
Associated
documentation
This document is an integral part of the following Operating
Instructions:
BA00061S/04
Supplementary
documentation
Explosion-protection brochure: CP00021Z/11
The Explosion-protection brochure is available:
• In the download area of the Endress+Hauser website:
www.endress.com -> Downloads -> Brochures and Catalogs ->
Text Search: CP00021Z
• On the CD for devices with CD-based documentation
Manufacturer's
certificates
EU Declaration of Conformity
Declaration Number:
EC_00089
The EU Declaration of Conformity is available:
In the download area of the Endress+Hauser website:
www.endress.com -> Downloads -> Declaration ->
Type: EU Declaration -> Product Code: ...
EU type-examination certificate
Certificate number:
BVS 15 ATEX E 128
List of applied standards: See EU Declaration of Conformity.
IEC Declaration of Conformity
Certificate number:
IECEx BVS 15.0105

WirelessHART adapter SWA70 XA01366F-C
Endress+Hauser 5
Affixing the certificate number certifies conformity with the following
standards (depending on the device version):
• IEC 60079-0 : 2017
• IEC 60079-11 : 2011
• IEC 60079-31 : 2013
Manufacturer
address
Endress+Hauser SE+Co. KG
Hauptstraße 1
79689 Maulburg, Germany
Address of the manufacturing plant: See nameplate.
Other standards Among other things, the following standards shall be observed in their
current version for proper installation:
• IEC/EN 60079-14: "Explosive atmospheres - Part 14: Electrical
installations design, selection and erection"
• EN 1127-1: "Explosive atmospheres - Explosion prevention and
protection - Part 1: Basic concepts and methodology"
Extended
order code
The extended order code is indicated on the nameplate, which is affixed
to the device in such a way that it is clearly visible. Additional
information about the nameplate is provided in the associated
Operating Instructions.
Structure of the extended order code
SWA70 – ************* + A*B*C*D*E*F*G*..
(Device
type)
(Basic
specifications)
(Optional
specifications)
* = Placeholder
At this position, an option (number or letter) selected from the
specification is displayed instead of the placeholders.
Basic specifications
The features that are absolutely essential for the device (mandatory
features) are specified in the basic specifications. The number of
positions depends on the number of features available.
The selected option of a feature can consist of several positions.

XA01366F-C WirelessHART adapter SWA70
6 Endress+Hauser
Optional specifications
The optional specifications describe additional features for the device
(optional features). The number of positions depends on the number of
features available. The features have a 2-digit structure to aid
identification (e.g. JA). The first digit (ID) stands for the feature group
and consists of a number or a letter (e.g. J = Test, Certificate). The
second digit constitutes the value that stands for the feature within the
group (e.g. A = 3.1 material (wetted parts), inspection certificate).
More detailed information about the device is provided in the following
tables. These tables describe the individual positions and IDs in the
extended order code which are relevant to hazardous locations.
Extended order code: WirelessHART adapter
The following specifications reproduce an extract from the product
structure and are used to assign:
• This documentation to the device (using the extended order
code on the nameplate).
• The device options cited in the document.
Device type
SWA70
Basic specifications
Position 1, 2 (Approval)
Selected option Description
SWA70 BE ATEX II 2 G Ex ia IIC T3/T4 Gb
B1 ATEX II 2 G Ex ia IIC T3/T4 Gb
ATEX II 2 D Ex tb [ia] IIIC T70°C Db
IE IECEx Ex ia IIC T3/T4 Gb
I1 IECEx Ex ia IIC T3/T4 Gb
IECEx Ex tb [ia] IIIC T70°C Db
Position 3 (Output)
Selected option Description
SWA70 2 4-20 mA HART (U0 = 28 V)

WirelessHART adapter SWA70 XA01366F-C
Endress+Hauser 7
Position 4 (Housing)
Selected option Description
SWA70 A F32, Polyester, IP66, NEMA Type 4X Encl.
B F33, Aluminium, IP66/67 NEMA Type 4X Encl.
C F39, 316L, IP66/67, NEMA Type 4X Encl.
Position 5 (Power Supply)
Selected option Description
SWA70 1 Battery BU191, Lithium metal, built-in, transport class 9/2,
UN3091
5 Prepared for battery
Optional specifications
No options specific to hazardous locations are available.
Safety
instructions:
General
• Staff must meet the following conditions for mounting, electrical
installation, commissioning and maintenance of the device:
• Be suitably qualified for their role and the tasks they perform
• Be trained in explosion protection
• Be familiar with national regulations
• Install the device according to the manufacturer's instructions and
national regulations.
• Avoid electrostatic charging:
• Of plastic surfaces (e.g. enclosure, sensor element, special
varnishing, attached additional plates, ..)
• Of isolated capacities (e.g. isolated metallic plates)
• Dispose of used battery packs in an environmentally compatible
manner.
• Observe national regulations on waste disposal.
Safety
instructions:
Special conditions
In the event of additional or alternative special varnishing on the
enclosure or other metal parts:
• Observe the danger of electrostatic charging and discharge.
• Do not rub surfaces with a dry cloth.

XA01366F-C WirelessHART adapter SWA70
8 Endress+Hauser
Safety
instructions:
Installation
A B1B2
A0031992
1
A Zone 1, Zone 21
B1 Direct mounting at field device
B2 Separate mounting with cable connection
• Avoid electrostatic charging (e.g. do not rub dry):
• Of enclosure and antenna
• Of the connecting cable
• Of the "push button" special version (if available)
• The WirelessHART adapter is suitable for use in gases of Groups IIC
and IIB if electrostatic charging (e.g. through friction, cleaning,
maintenance, strong medium flow) is avoided.
• WirelessHART adapter: Indicated by the warning sign
"Avoid Electrostatic Charge".
• Observe the pertinent guidelines when interconnecting intrinsically
safe circuits.
• To maintain the ingress protection of the enclosure:
• Screw the cover tight.
• Mount the cable entry correctly.
• After aligning (rotating) the enclosure, retighten the fixing screw.
• Protect the connecting cable between the WirelessHART adapter and
the field device from tension and friction (e.g. due to electrostatic
charge from medium flow).
Basic specification, Position 4 = A
Torque must be observed:
• Cover screws: 0.7 Nm ±10 %
• Cable glands: 3.25 Nm ±10 %
• Sealing plug: 3.25 Nm ±10 %

WirelessHART adapter SWA70 XA01366F-C
Endress+Hauser 9
Basic specification, Position 4 = B, C
Torque must be observed:
• Cover screws: 0.7 Nm ±10 %
• Cable glands: 6.25 Nm ±10 %
• Sealing plug: 6.25 Nm ±10 %
Potential equalization
Integrate the device into the local potential equalization.
Safety
instructions:
Zone 1
• Configuring the device: The electronics compartment can be opened
when energized.
• To replace the battery, the WirelessHART adapter may be opened in
hazardous locations.
• Seal unused entry glands with approved sealing plugs that correspond
to the type of protection.
Basic specification, Position 4 = A with "push button" special version
When connecting the device, make sure that the the push-button is still
connected (→ 3, 11, Terminals 2 and 5).
Safety
instructions:
Zone 21
• Do not open in a potentially explosive dust atmosphere.
• The battery pack must not be exchanged in dust explosion-hazardous
areas.
• Cable glands with ATEX-Ex e approval and metallic glands: Only use
with an ingress protection of at least IP65. Lay connecting cable and
secure.
• Seal unused entry glands with approved sealing plugs that correspond
to the type of protection.
Basic specification, Position 4 = A
Only suitable for use in Zone 1!
Safety
instructions:
Battery
• Only use the Endress+Hauser battery pack of type BU191 from serial
number: 14/01/xxxxxxxx as specified in the Operating Instructions.
• The PHR2 plug-in connector is designed in such a way that reverse
polarity is not possible.
• Short-circuiting the plus and minus cable trips the irreversible, non-
replaceable fuse.
• In gas explosion-hazardous areas: Only one battery pack of type
BU191 is permitted.
• The safety of the device can be impaired, e.g.:
• In case of visible damage to the battery enclosure
• In case of improper storage
• In case of damage during transportation

XA01366F-C WirelessHART adapter SWA70
10 Endress+Hauser
Temperature
tables
Type of
protection
Ambient temperature Ta
(ambient)
Temperature
class
Enclosure
Ex ia IIC –40 °C ≤ Ta ≤ +50 °C T4 Basic specification,
Position 4 = A, B, C
–40 °C ≤ Ta ≤ +60 °C T3
Type of
protection
Ambient temperature Ta
(ambient)
Max. surface
temperature
Enclosure
Ex tb [ia] IIIC –40 °C ≤ Ta ≤ +60 °C +70 °C Basic specification,
Position 4 = B, C
Connection data 4...20 mA + HART communication
Connection options of the terminals: See Operating Instruction
BA00061S, chapter "Electrical installation".
Adapter active (Terminals 1, 2) Adapter passive (Terminals 2-8)
Uo < 28 VDC
Io < 99 mA
Po < 692 mW
Lo = 3.45 mH or
Co = 70 nF
Ui = 30 VDC
Ii = 100 mA
Pi = 751 mW
Li = 426 µH
Ci = 24 nF
The adapter can be configured via two terminals (7 and 8, parallel to
terminals 5 and 6) using a certified handheld terminal and taking into
account safety-related nominal values.
power
12345
7
6
8
V+
1 2 3 4 5
7
6
8
V+
A0031994
2

WirelessHART adapter SWA70 XA01366F-C
Endress+Hauser 11
Connection of the "push button" special version (only for
Basic specification, Position 4 = A)
power
1
1
2
2
3
3
4
4
5
5
7
6
6
8
V+
V+
A0031993
3
Connection of the LPI plug (active), optional feature
1(+) 2(-)
5(+) 6(-) or 7(+) 8(-)
1(+) 2(-)
5(+) 6(-) or 7(+) 8(-)
ection:
powered
more types
ld
A0031995
4
Power supply
Uo = 7.80 V
Io = 1.03 A
Po = 1.22 W
Lo = 21.51 µH or
Co = 9.18 µF

www.addresses.endress.com
*71530407*
71530407
Other manuals for SWA70
3
Table of contents
Other Endress+Hauser Adapter manuals

Endress+Hauser
Endress+Hauser FieldPort SWA50 User manual

Endress+Hauser
Endress+Hauser CUA261 User manual

Endress+Hauser
Endress+Hauser Commubox FXA291 User manual

Endress+Hauser
Endress+Hauser SWA70 User manual

Endress+Hauser
Endress+Hauser SWA70 User manual

Endress+Hauser
Endress+Hauser FieldPort SWA50 Manual

Endress+Hauser
Endress+Hauser FieldPort SWA50 User manual