Enterasys S Series Manual

P/N 9034461-05
Enterasys S-Series™
Option Module
Hardware Installation Guide


i
Notice
Enterasys Networks reserves the right to make changes in specifications and other information contained in this document and
its web site without prior notice. The reader should in all cases consult Enterasys Networks to determine whether any such
changes have been made.
The hardware, firmware, or software described in this document is subject to change without notice.
IN NO EVENT SHALL ENTERASYS NETWORKS BE LIABLE FOR ANY INCIDENTAL, INDIRECT, SPECIAL, OR
CONSEQUENTIAL DAMAGES WHATSOEVER (INCLUDING BUT NOT LIMITED TO LOST PROFITS) ARISING OUT OF
OR RELATED TO THIS DOCUMENT, WEB SITE, OR THE INFORMATION CONTAINED IN THEM, EVEN IF
ENTERASYS NETWORKS HAS BEEN ADVISED OF, KNEW OF, OR SHOULD HAVE KNOWN OF, THE POSSIBILITY OF
SUCH DAMAGES.
Enterasys Networks, Inc.
9 Northeastern Boulevard
Salem, NH 03079
2013 Enterasys Networks, Inc. All rights reserved.
Part Number: 9034461-05 June 2013
ENTERASYS, ENTERASYS NETWORKS, ENTERASYS SECURE NETWORKS, and any logos associated therewith, are
trademarks or registered trademarks of Enterasys Networks, Inc., in the United States and/or other countries. For a complete
list of Enterasys trademarks, see http://www.enterasys.com/company/trademarks.aspx.
All other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies.
Documentation URL: https://extranet.enterasys.com/downloads/
Electrical Hazard: Only qualified personnel should perform installation procedures.
Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de instalacion.
Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes Personal
vorgenommen werden.
Risques d'électrocution:Seul un personnel qualifié doit effectuer les procédures d'installation.

ii
Regulatory Compliance Information
Federal Communications Commission (FCC) Notice
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of
the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment uses, generates, and can radiate radio frequency energy and if not
installed in accordance with the operator’s manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference
at his own expense.
WARNING: Changes or modifications made to this device which are not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
Industry Canada Notice
This digital apparatus does not exceed the class A limits for radio noise emissions from digital apparatus set out in the Radio
Interference Regulations of the Canadian Department of Communications.
Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils
numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des
Communications du Canada.
Class A ITE Notice
WARNING: This is a Class A product. In a domestic environment this product may cause radio interference in which case the
user may be required to take adequate measures.
Clase A. Aviso de ITE
ADVERTENCIA: Este es un producto de Clase A. En un ambiente doméstico este producto puede causar interferencia de radio
en cuyo caso puede ser requerido tomar medidas adecuadas.
Klasse A ITE Anmerkung
WARNHINWEIS: Dieses Produkt zählt zur Klasse A ( Industriebereich ). In Wohnbereichen kann es hierdurch zu
Funkstörungen kommen, daher sollten angemessene Vorkehrungen zum Schutz getroffen werden.
VCCI Notice
This is a class A product based on the standard of the Voluntary Control Council for Interference by Information Technology
Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble
occurs, the user may be required to take corrective actions.

iii
BSMI EMC Statement — Taiwan
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be
required to take adequate measures.
AS/NZS CISPR 22
Hazardous Substances
This product complies with the requirements of Directive 2011/65/EU of the European Parliament and of the Council of 8 June
2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
European Waste Electrical and Electronic Equipment (WEEE) Notice
In accordance with Directive 2012/19/EU of the European Parliament on waste electrical and electronic equipment (WEEE):
1. The symbol above indicates that separate collection of electrical and electronic equipment is required.
2. When this product has reached the end of its serviceable life, it cannot be disposed of as unsorted municipal waste. It must
be collected and treated separately.
3. It has been determined by the European Parliament that there are potential negative effects on the environment and human
health as a result of the presence of hazardous substances in electrical and electronic equipment.
4. It is the users’ responsibility to utilize the available collection system to ensure WEEE is properly treated.
For information about the available collection system, please contact Enterasys Customer Support at +353 61 705500
(Ireland).

iv
ѻѻક䇈ᯢк䰘ӊ
Supplement to Product Instructions
᳝↦᳝ᆇ⠽䋼ܗ㋴(Hazardous Substance)
䚼ӊৡ⿄
(Parts) 䪙
3E
∲
+J
䬝
&G
݁Ӌ䫀
&U
⒈㘨㣃
3%%
⒈Ѡ㣃䝮
3%'(
䞥ሲ䚼ӊ
(Metal Parts)
hƻ ƻ h ƻ ƻ
⬉䏃ഫ
(Circuit Modules)
hƻ ƻ h ƻ ƻ
⬉㓚ঞ⬉㓚㒘ӊ
(Cables & Cable Assemblies)
hƻ ƻ h ƻ ƻ
ล᭭㘮ড়⠽䚼ӊ
(Plastic and Polymeric parts)
ƻƻ ƻ ƻ ƻ h
⬉䏃ᓔ݇
(Circuit Breakers)
ƻƻ h h ƻ ƻ
ƻ˖ 㸼⼎䆹᳝↦᳝ᆇ⠽䋼䆹䚼ӊ᠔᳝ഛ䋼ᴤ᭭Ёⱘ䞣ഛ SJ/T 11363-2006 ޚ㾘ᅮⱘ䰤䞣㽕∖ҹϟDŽ
Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is
below the relevant threshold of the SJ/T 11363-2006 standard.
h˖ 㸼⼎䆹᳝↦᳝ᆇ⠽䋼㟇ᇥ䆹䚼ӊⱘᶤϔഛ䋼ᴤ᭭Ёⱘ䞣䍙ߎSJ/T 11363-2006 ޚ㾘ᅮⱘ䰤䞣㽕∖DŽ
Indicates that the concentration of the hazardous substance of at least one of all homogeneous
materials in the parts is above the relevant threshold of the SJ/T 11363-2006 standard.
ᇍ䫔ଂП᮹ⱘ᠔ଂѻકᴀ㸼ᰒ⼎
߃߯կᑨ䫒ⱘ⬉ᄤֵᙃѻકৃ㛑ࣙ䖭ѯ⠽䋼DŽ⊼ᛣ᠔ଂѻકЁৃ㛑Ӯгৃ㛑ϡӮ᳝᠔᳝᠔߫ⱘ䚼ӊDŽ
This table shows where these substances may be found in the supply chain of Enterasys electronic
information products, as of the date of sale of the enclosed product. Note that some of the component types
listed above may or may not be a part of the enclosed product.
ℸ⦃ֱՓ⫼ᳳ䰤া䗖⫼ѢѻકᰃѻકݠЁ᠔㾘ᅮⱘᴵӊϟᎹ
The Environmentally Friendly Use Period (EFUP) for all enclosed products and their parts
are per the symbol shown here, unless otherwise marked. Certain parts may have a
different EFUP (for example, battery modules) and so are marked to reflect such. The
Environmentally Friendly Use Period is valid only when the product is operated under the
conditions defined in the product manual.
䰸䴲⡍߿ⱘ⊼ℸᖫЎ䩜ᇍ᠔⍝ঞѻકⱘ⦃ֱՓ⫼ᳳᖫᶤѯ䳊䚼ӊӮ
᳝ϔϾϡৠⱘ⦃ֱՓ⫼ᳳ՟བ⬉∴ܗഫ䌈݊ѻકϞ

v
Safety Information
Class 1 Laser Transceivers
The single mode interface modules use Class 1 laser transceivers.
Read the following safety information before installing or operating these modules.
The Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits. This control loop eliminates the
need for maintenance checks or adjustments. The output is factory set, and does not allow any user adjustment. Class 1 Laser
transceivers comply with the following safety standards:
• 21 CFR 1040.10 and 1040.11 U.S. Department of Health and Human Services (FDA).
• IEC Publication 825 (International Electrotechnical Commission).
• CENELEC EN 60825 (European Committee for Electrotechnical Standardization).
When operating within their performance limitations, laser transceiver output meets the Class 1 accessible emission limit of all
three standards. Class 1 levels of laser radiation are not considered hazardous.
When the connector is in place, all laser radiation remains within the fiber. The maximum amount of radiant power exiting the
fiber (under normal conditions) is -12.6 dBm or 55 x 10-6 watts.
Removing the optical connector from the transceiver allows laser radiation to emit directly from the optical port. The maximum
radiance from the optical port (under worst case conditions) is 0.8 W cm-2 or 8 x 103W m2sr-1.
Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye
hazard. When viewing the output optical port, power must be removed from the network adapter.
Safety Compliance
Warning: Fiber Optic Port Safety
Avertissment: Ports pour fibres optiques - sécurité sur le plan optique
Warnhinweis: Faseroptikanschlüsse - Optische Sicherheit
When using a fiber optic media expansion module, never look at the transmit laser
while it is powered on. Also, never look directly at the fiber TX port and fiber cable
ends when they are powered on.
Ne regardez jamais le laser tant qu’il est sous tension. Ne regardez jamais
directement le port TX (Tramsmission) à fibres optiques et les embouts de câbles à
fibres optiques tant qu’ils sont sous tension.
Niemals ein Übertragungslaser betrachten, während dieses eingeschaltet ist.
Niemals direkt auf den Faser-TX-Anschluß und auf die Faserkabelenden schauen,
während diese eingeschaltet sind.

vi
Declaration of Conformity
Application of Council Directive(s): 2004/108/EC
2006/95/EC
Manufacturer’s Name: Enterasys Networks, Inc.
Manufacturer’s Address: 9 Northeastern Boulevard
Salem, NH 03079
USA
European Representative Name: Enterasys Networks Limited
European Representative Address: Nexus House, Newbury Business Park
London Road, Newbury
Berkshire RG14 2PZ, England
Conformance to Directive(s)/Product Standards: EC Directive 2004/108/EC
EN55022:2006
A1:2007
EN 55024:1998
A1:2001
A2:2003
EN 61000-3-2:2006
A1:2009
A2:2009
EN 61000-3-3:2008
EC Directive 2006/95/EC
EN 60950-1:2006
A1:2009
EN 60825-1:2007
EN 60825-2:2004
A1:2007
EC Directive 2011/65/EU
Equipment Type/Environment: Information Technology Equipment, for use in a Commercial
or Light Industrial Environment.
The object of the declaration described above is in conformity with Directive 2011/65/EU of the European Parliament and of the
Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment.

vii
Enterasys Networks, Inc. Firmware License Agreement
BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT,
CAREFULLY READ THIS LICENSE AGREEMENT.
This document is an agreement (“Agreement”) between the end user (“You”) and Enterasys Networks, Inc., on behalf of itself
and its Affiliates (as hereinafter defined) (“Enterasys”) that sets forth Your rights and obligations with respect to the Enterasys
software program/firmware (including any accompanying documentation, hardware or media) (“Program”) in the package
and prevails over any additional, conflicting or inconsistent terms and conditions appearing on any purchase order or other
document submitted by You. “Affiliate” means any person, partnership, corporation, limited liability company, other form of
enterprise that directly or indirectly through one or more intermediaries, controls, or is controlled by, or is under common
control with the party specified. This Agreement constitutes the entire understanding between the parties, with respect to the
subject matter of this Agreement. The Program may be contained in firmware, chips or other media.
BY INSTALLING OR OTHERWISE USING THE PROGRAM, YOU REPRESENT THAT YOU ARE AUTHORIZED TO ACCEPT
THESE TERMS ON BEHALF OF THE END USER (IF THE END USER IS AN ENTITY ON WHOSE BEHALF YOU ARE
AUTHORIZED TO ACT, “YOU” AND “YOUR” SHALL BE DEEMED TO REFER TO SUCH ENTITY) AND THAT YOU
AGREE THAT YOU ARE BOUND BY THE TERMS OF THIS AGREEMENT, WHICH INCLUDES, AMONG OTHER
PROVISIONS, THE LICENSE, THE DISCLAIMER OF WARRANTY AND THE LIMITATION OF LIABILITY. IF YOU DO NOT
AGREE TO THE TERMS OF THIS AGREEMENT OR ARE NOT AUTHORIZED TO ENTER INTO THIS AGREEMENT,
ENTERASYS IS UNWILLING TO LICENSE THE PROGRAM TO YOU AND YOU AGREE TO RETURN THE UNOPENED
PRODUCT TO ENTERASYS OR YOUR DEALER, IF ANY, WITHIN TEN (10) DAYS FOLLOWING THE DATE OF RECEIPT
FOR A FULL REFUND.
IF YOU HAVE ANY QUESTIONS ABOUT THIS AGREEMENT, CONTACT ENTERASYS NETWORKS, LEGAL
DEPARTMENT AT (603) 952-5000.
You and Enterasys agree as follows:
1. LICENSE. You have the non-exclusive and non-transferable right to use only the one (1) copy of the Program provided in
this package subject to the terms and conditions of this Agreement.
2. RESTRICTIONS. Except as otherwise authorized in writing by Enterasys, You may not, nor may You permit any third
party to:
(a) Reverse engineer, decompile, disassemble or modify the Program, in whole or in part, including for reasons of error
correction or interoperability, except to the extent expressly permitted by applicable law and to the extent the parties
shall not be permitted by that applicable law, such rights are expressly excluded. Information necessary to achieve
interoperability or correct errors is available from Enterasys upon request and upon payment of Enterasys’ applicable
fee.
(b) Incorporate the Program in whole or in part, in any other product or create derivative works based on the Program, in
whole or in part.
(c) Publish, disclose, copy reproduce or transmit the Program, in whole or in part.
(d) Assign, sell, license, sublicense, rent, lease, encumber by way of security interest, pledge or otherwise transfer the
Program, in whole or in part.
(e) Remove any copyright, trademark, proprietary rights, disclaimer or warning notice included on or embedded in any
part of the Program.
3. APPLICABLE LAW. This Agreement shall be interpreted and governed under the laws and in the state and federal courts
of the State of New Hampshire without regard to its conflicts of laws provisions. You accept the personal jurisdiction and venue
of the State of New Hampshire courts. None of the 1980 United Nations Convention on the Limitation Period in the International
Sale of Goods, and the Uniform Computer Information Transactions Act shall apply to this Agreement.
4. EXPORT RESTRICTIONS. You understand that Enterasys and its Affiliates are subject to regulation by agencies of the
U.S. Government, including the U.S. Department of Commerce, which prohibit export or diversion of certain technical products
to certain countries, unless a license to export the product is obtained from the U.S. Government or an exception from obtaining
such license may be relied upon by the exporting party.
If the Program is exported from the United States pursuant to the License Exception CIV under the U.S. Export
Administration Regulations, You agree that You are a civil end user of the Program and agree that You will use the Program for
civil end uses only and not for military purposes.
If the Program is exported from the United States pursuant to the License Exception TSR under the U.S. Export
Administration Regulations, in addition to the restriction on transfer set forth in Section 1 or 2 of this Agreement, You agree not
to (i) reexport or release the Program, the source code for the Program or technology to a national of a country in Country
Groups D:1 or E:2 (Albania, Armenia, Azerbaijan, Belarus, Cambodia, Cuba, Georgia, Iraq, Kazakhstan, Laos, Libya, Macau,
Moldova, Mongolia, North Korea, the People’s Republic of China, Russia, Tajikistan, Turkmenistan, Ukraine, Uzbekistan,

viii
Vietnam, or such other countries as may be designated by the United States Government), (ii) export to Country Groups D:1 or
E:2 (as defined herein) the direct product of the Program or the technology, if such foreign produced direct product is subject to
national security controls as identified on the U.S. Commerce Control List, or (iii) if the direct product of the technology is a
complete plant or any major component of a plant, export to Country Groups D:1 or E:2 the direct product of the plant or a
major component thereof, if such foreign produced direct product is subject to national security controls as identified on the
U.S. Commerce Control List or is subject to State Department controls under the U.S. Munitions List.
5. UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The enclosed Program (i) was developed solely at private
expense; (ii) contains “restricted computer software” submitted with restricted rights in accordance with section 52.227-19 (a)
through (d) of the Commercial Computer Software-Restricted Rights Clause and its successors, and (iii) in all respects is
proprietary data belonging to Enterasys and/or its suppliers. For Department of Defense units, the Program is considered
commercial computer software in accordance with DFARS section 227.7202-3 and its successors, and use, duplication, or
disclosure by the U.S. Government is subject to restrictions set forth herein.
6. DISCLAIMER OF WARRANTY. EXCEPT FOR THOSE WARRANTIES EXPRESSLY PROVIDED TO YOU IN WRITING
BY ENTERASYS, ENTERASYS DISCLAIMS ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT
LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A PARTICULAR
PURPOSE, TITLE AND NON-INFRINGEMENT WITH RESPECT TO THE PROGRAM. IF IMPLIED WARRANTIES MAY NOT
BE DISCLAIMED BY APPLICABLE LAW, THEN ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THIRTY
(30) DAYS AFTER DELIVERY OF THE PROGRAM TO YOU.
7. LIMITATION OF LIABILITY. IN NO EVENT SHALL ENTERASYS OR ITS SUPPLIERS BE LIABLE FOR ANY
DAMAGES WHATSOEVER (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS, PROFITS,
BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION, SPECIAL, INCIDENTAL, CONSEQUENTIAL, OR
RELIANCE DAMAGES, OR OTHER LOSS) ARISING OUT OF THE USE OR INABILITY TO USE THE PROGRAM, EVEN IF
ENTERASYS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THIS FOREGOING LIMITATION SHALL
APPLY REGARDLESS OF THE CAUSE OF ACTION UNDER WHICH DAMAGES ARE SOUGHT.
THE CUMULATIVE LIABILITY OF ENTERASYS TO YOU FOR ALL CLAIMS RELATING TO THE PROGRAM, IN
CONTRACT, TORT OR OTHERWISE, SHALL NOT EXCEED THE TOTAL AMOUNT OF FEES PAID TO ENTERASYS BY
YOU FOR THE RIGHTS GRANTED HEREIN.
8. AUDIT RIGHTS. You hereby acknowledge that the intellectual property rights associated with the Program are of critical
value to Enterasys, and, accordingly, You hereby agree to maintain complete books, records and accounts showing (i) license
fees due and paid, and (ii) the use, copying and deployment of the Program. You also grant to Enterasys and its authorized
representatives, upon reasonable notice, the right to audit and examine during Your normal business hours, Your books, records,
accounts and hardware devices upon which the Program may be deployed to verify compliance with this Agreement, including
the verification of the license fees due and paid Enterasys and the use, copying and deployment of the Program. Enterasys’ right
of examination shall be exercised reasonably, in good faith and in a manner calculated to not unreasonably interfere with Your
business. In the event such audit discovers non-compliance with this Agreement, including copies of the Program made, used
or deployed in breach of this Agreement, You shall promptly pay to Enterasys the appropriate license fees. Enterasys reserves
the right, to be exercised in its sole discretion and without prior notice, to terminate this license, effective immediately, for failure
to comply with this Agreement. Upon any such termination, You shall immediately cease all use of the Program and shall return
to Enterasys the Program and all copies of the Program.
9. OWNERSHIP. This is a license agreement and not an agreement for sale. You acknowledge and agree that the Program
constitutes trade secrets and/or copyrighted material of Enterasys and/or its suppliers. You agree to implement reasonable
security measures to protect such trade secrets and copyrighted material. All right, title and interest in and to the Program shall
remain with Enterasys and/or its suppliers. All rights not specifically granted to You shall be reserved to Enterasys.
10. ENFORCEMENT. You acknowledge and agree that any breach of Sections 2, 4, or 9 of this Agreement by You may cause
Enterasys irreparable damage for which recovery of money damages would be inadequate, and that Enterasys may be entitled
to seek timely injunctive relief to protect Enterasys’ rights under this Agreement in addition to any and all remedies available at
law.
11. ASSIGNMENT. You may not assign, transfer or sublicense this Agreement or any of Your rights or obligations under this
Agreement, except that You may assign this Agreement to any person or entity which acquires substantially all of Your stock
assets. Enterasys may assign this Agreement in its sole discretion. This Agreement shall be binding upon and inure to the benefit
of the parties, their legal representatives, permitted transferees, successors and assigns as permitted by this Agreement. Any
attempted assignment, transfer or sublicense in violation of the terms of this Agreement shall be void and a breach of this
Agreement.
12. WAIVER. A waiver by Enterasys of a breach of any of the terms and conditions of this Agreement must be in writing and
will not be construed as a waiver of any subsequent breach of such term or condition. Enterasys’ failure to enforce a term upon
Your breach of such term shall not be construed as a waiver of Your breach or prevent enforcement on any other occasion.

ix
13. SEVERABILITY. In the event any provision of this Agreement is found to be invalid, illegal or unenforceable, the validity,
legality and enforceability of any of the remaining provisions shall not in any way be affected or impaired thereby, and that
provision shall be reformed, construed and enforced to the maximum extent permissible. Any such invalidity, illegality, or
unenforceability in any jurisdiction shall not invalidate or render illegal or unenforceable such provision in any other
jurisdiction.
14. TERMINATION. Enterasys may terminate this Agreement immediately upon Your breach of any of the terms and
conditions of this Agreement. Upon any such termination, You shall immediately cease all use of the Program and shall return
to Enterasys the Program and all copies of the Program.

x

xi
Contents
About This Guide
Who Should Use This Guide ...........................................................................................................................xiii
How to Use This Guide ....................................................................................................................................xiii
Related Documents .........................................................................................................................................xiv
Typographical Conventions .............................................................................................................................xiv
Getting Help ......................................................................................................................................................xv
Chapter 1: Introduction
Option Module Types and Compatibility .........................................................................................................1-1
Option Module Port Options ...........................................................................................................................1-2
Power over Ethernet .......................................................................................................................................1-2
Management ...................................................................................................................................................1-2
Chapter 2: Installing the Option Module
Required Tools ...............................................................................................................................................2-1
Unpacking the Option Module ........................................................................................................................2-2
Installing the Option Module ...........................................................................................................................2-2
Connecting the Option Module to the Network ...............................................................................................2-8
Connecting Category 5 UTP Ethernet Cables to the RJ45 Ports .............................................................2-8
Connecting Pluggable Transceivers to the SFP and SFP+ Ports ............................................................2-9
LEDs .............................................................................................................................................................2-10
Appendix A: Specifications and Regulatory Compliance
Option Module Specifications .........................................................................................................................A-1
SFP and SFP+ Fiber-Optic Specifications ......................................................................................................A-1
Regulatory Compliance ..................................................................................................................................A-1
Appendix B: Removing an Option Module from an I/O Module
Required Tools ...............................................................................................................................................B-1
Removing an Option Module ..........................................................................................................................B-1
Figures
2-1 Removing the Faceplate and Top Cover from the S-Series Module..................................................2-3
2-2 Removing the Option Slot Cover........................................................................................................2-4
2-3 Installing the PoE Power Header for an Option Module with RJ45 Ports...........................................2-5
2-4 Installing the Option Module...............................................................................................................2-6
2-5 Securing the Option Module to the S-Series Module .........................................................................2-7
2-6 Option Module LEDs (RJ45, SFP, and SFP+ Ports) ........................................................................2-10
B-1 Removing the Top Cover and Faceplate of the I/O Module ...............................................................B-2
B-2 Removing the Four Pan Head Screws ...............................................................................................B-3
B-3 Removing the Option Module from the I/O Module ............................................................................B-4
B-4 Removing the PoE Power Header (If Necessary) ..............................................................................B-5
Tables
1-1 S-Series Option Module Compatibility................................................................................................1-1
2-1 Port LEDs .........................................................................................................................................2-11
A-1 Compliance Standards .......................................................................................................................A-1

xii

Enterasys S-Series Option Module Hardware Installation Guide xiii
About This Guide
This guide provides an overview, installation and removal instructions, and specifications for the
Enterasys S-Series™option modules.
Who Should Use This Guide
This guide is intended for a network administrator who is responsible for installing and cabling S-
Series option modules.
How to Use This Guide
Read through this guide completely to familiarize yourself with its contents and to gain an
understanding of the features and capabilities of the S-Series option modules. A general working
knowledge of data communications networks is helpful when setting up the S-Series option
modules.
This preface provides the following:
• An overview of this guide and the S-Series manual set
• A brief summary of each chapter
• Definitions of the conventions used in this document
• Instructions regarding how to obtain technical support from Enterasys Networks.
To locate information about various subjects in this guide, refer to the following table.
Electrical Hazard: Only qualified personnel should install or service this unit.
Riesgo Electrico: Nada mas personal capacitado debe de instalar o darle servicio a esta unida.
Elektrischer Gefahrenhinweis: Installationen oder Servicearbeiten sollten nur durch
ausgebildetes und qualifiziertes Personal vorgenommen werden.
Risques d'électrocution: Seul un personnel qualifié doit installer ou effectuer les opérations de
maintenance sur cet élément.
For... Refer to...
An overview of the S-Series option modules. Chapter 1, Introduction
Instructions for installing the option modules in S-Series
modules. Chapter 2, Installing the Option Module
Specifications, environmental requirements, and physical
properties of the S-Series option modules. Appendix A, Specifications and
Regulatory Compliance
Instructions for removing option modules from S-Series
modules. Appendix B, Removing an Option
Module from an I/O Module

Related Documents
xiv About This Guide
Related Documents
Enterasys S-Series Configuration Guide and Enterasys S-Series CLI Reference Guide provide
information on how to use the CLI to set up and manage the S-Series devices.
These manuals can be obtained from the World Wide Web in Adobe Acrobat Portable Document
Format (PDF) at the following site:
https://extranet.enterasys.com/downloads/
Typographical Conventions
The following typographical conventions and icons are used in this document.
blue type Indicates a hypertext link. When reading this document online, click the text in blue to go to
the referenced figure, table, or section.
Lowercase x Indicates the general use of an alphanumeric character.
Note: Calls the reader’s attention to any item of information that may be of special
importance.
Caution: Contains information essential to avoid damage to the equipment.
Precaución: Contiene información esencial para prevenir dañar el equipo.
Achtung: Verweißt auf wichtige Informationen zum Schutz gegen Beschädigungen.
Warning: Warns against an action that could result in personal injury or death.
Advertencia: Advierte contra una acción que pudiera resultar en lesión corporal o la
muerte.
Warnhinweis: Warnung vor Handlungen, die zu Verletzung von Personen oder gar
Todesfällen führen können!
Avertissements: Met en garde contre un geste qui pourrait entraîner des blessures ou la
mort.
Electrical Hazard: Warns against an action that could result in personal injury or death
due to an electrical hazard.
Riesgo Electrico: Advierte contra una acción que pudiera resultar en lesión corporal o la
muerte debido a un riesgo eléctrico.
Elektrischer Gefahrenhinweis: Warnung vor sämtlichen Handlungen, die zu Verletzung
von Personen oder Todesfällen – hervorgerufen durch elektrische Spannung – führen
können!
Risques d'électrocution: Met en garde contre un geste qui pourrait entraîner des
blessures ou la mort à la suite d'une électrocution.

Getting Help
Enterasys S-Series Option Module Hardware Installation Guide xv
Getting Help
For additional support related to the S-Series or this document, contact Enterasys Networks using
one of the following methods:
Before contacting Enterasys Networks for technical support, have the following data ready:
• Your Enterasys Networks service contract number
• A description of the failure
• A description of any action(s) already taken to resolve the problem (for example, changing
mode switches or rebooting the unit)
• The serial and revision numbers of all involved Enterasys Networks products in the network
• A description of your network environment (such as layout, cable type, other relevant
environmental information)
• Network load and frame size at the time of trouble (if known)
• The device history (for example, if you have returned the device before, or if this is a recurring
problem)
• Any previous Return Material Authorization (RMA) numbers
World Wide Web http://www.enterasys.com/support
Phone 1-800-872-8440 (toll-free in U.S. and Canada)
or 1-603-952-5000
For the Enterasys Networks Support toll-free number in your country:
http://www.enterasys.com/support
Email [email protected]
To expedite your message, please type [S-Series] in the subject line.

Getting Help
xvi About This Guide

Enterasys S-Series Option Module Hardware Installation Guide 1-1
1
Introduction
Option Module Types and Compatibility
Many S-Series I/O fabric modules and I/O modules can be expanded by installing S-Series option
modules in their option module slots. Two types of S-Series option modules are available:
• Type 1 — The option module has one 20Gb connector for connecting to an S-Series module’s
motherboard.
• Type 2 —The option module has two 20Gb connectors for connecting to an S-Series module’s
motherboard.
To ensure that your S-Series option module is compatible with an S-Series I/O fabric module or I/O
module, refer to Table 1-1.
For a complete list of the available S-Series I/O modules and I/O fabric modules and their
compatibility with S-Series option modules, refer to the S-Series datasheet at
http://www.enterasys.com/products.
For information about... Refer to page...
Option Module Types and Compatibility 1-1
Option Module Port Options 1-2
Power over Ethernet 1-2
Management 1-2
Table 1-1 S-Series Option Module Compatibility
Install the Option Module in This S-Series Module?
S-Series
OptionModule
Type
S130
Class I/O
Module
S130
Class I/O
Fabric
Module
S140
Class I/O
Module
S150
Class I/O
Module
S150
Class I/O
Fabric
Module
S155
Class I/O
Fabric
Module
S180
Class I/O
Fabric
Module
Type 1 Yes Yes Yes Yes Yes Yes Yes
Type 2 No Yes Yes Yes Yes Yes Yes
Note: The VSB option module (SOV3208-0202) is compatible only with S140 Class I/O modules
and the S180 Class I/O fabric modules.

Option Module Port Options
1-2 Introduction
Option Module Port Options
S-Series option modules are available with the following port options:
• 10/100/1000BASE-TX RJ45 ports
• 1000BASE-X SFP ports
• 10GBASE-X SFP+ ports
IEEE 802.3af and 802.3at Power over Ethernet (PoE) are supported on the 10/100/1000BASE-TX
RJ45 ports.
Power over Ethernet
S-Series option modules with 10/100/1000BASE-TX RJ45 ports support both IEEE 802.3af and
802.3at Power over Ethernet (PoE) standards. Ensure that your configuration meets the following
criteria to supply PoE power to the 10/100/1000BASE-TX RJ45 ports on the S-Series option
modules:
• Your S-Series chassis has a PoE subsystem, with S-POE-PS power supplies, installed.
• You have installed the PoE-capable S-Series option module in a PoE-capable S-Series I/O fabric
module or I/O module. If a PoE-capable S-Series option module is installed in an S-Series I/O
fabric module or I/O module with SFP or SFP+ ports, the 10/100/1000BASE-TX RJ45 ports of
the option module will not function as PoE ports.
Depending on your PoE power supply configuration, the S-Series chassis can supply PoE power to
powered devices on all 10/100/1000BASE-TX RJ45 ports simultaneously.
The red PoE button on the left of the S-Series modules switches the RJ45 port LEDs to report PoE
information.
Management
You can manage the S-Series modules in which the S-Series option modules are installed either in-
band or out-of-band. In-band remote management is possible using the Enterasys Networks’
NetSight®management application or the command line interface (CLI) via Telnet. Out-of-band
management is provided through the RJ45 COM (Communication) port on the front panel of the
S-Series chassis using a PC, a VT terminal, or a VT terminal emulator.
Other manuals for S Series
5
This manual suits for next models
5
Table of contents
Other Enterasys Control Unit manuals
Popular Control Unit manuals by other brands

Honeywell
Honeywell RK-MCU Product instructions

Siemens
Siemens SCALANCE W788C-2 operating instructions

airinspace
airinspace Wall-i Pilot user manual

LifeSafety Power
LifeSafety Power M8 installation manual

Befaco
Befaco Quad-T Assembly manual

Spirax Sarco
Spirax Sarco PV4 Installation and maintenance instructions