Enviro Cams DS05M Instruction Manual

IPO
IP Vide
o
CHA
P
CHA
P
2.
1
2.
2
CHA
P
3.
1
3.
2
CHA
P
4.
1
4.
2
4.
3
4.
4
4.
5
CHA
P
5.
1
5.
2
5.
3
5.
4
5.
5
5.
6
5.
7
CHA
P
6.
1
6.
2
APP
E
A
P
A
P
o
Door St
a
P
TER 1. S
P
TER 2.
D
1
.
K
EY
F
EA
T
2
.
P
ACKAG
E
P
TER 3.
O
1
.
D
OOR
S
T
2
.
C
ONTRO
P
TER 4.
D
1
.
G
ENERA
L
2
.
I
NSTALL
A
3
.
D
OOR
S
T
4
.
M
EMOR
Y
5
.
W
IRED
C
P
TER 5.
W
1
.
D
EFININ
G
5.1.1. De
f
2
.
C
HANGI
N
3
.
A
CCESSI
4
.
A
CCESSI
5
.
C
ONFIG
U
6
.
R
ESTORI
7
.
V
ERIFYI
N
P
TER 6.
R
1
.
A
COUSTI
2
.
S
OUND
G
E
NDICES .
P
PENDIX
A.
P
PENDIX
B.
a
tion Inst
a
AFETY I
N
D
ESCRIPT
T
URES ......
E
CONTEN
T
O
VERVIE
W
T
ATION ......
LLER ........
D
OOR ST
A
L
INFORMA
T
A
TION REC
O
T
ATION MO
Y
CARD INS
C
ONNECTIO
W
IRED CO
G
THE LOC
A
f
ining the
L
N
G THE LO
C
NG THE D
O
NG THE D
O
U
RING DOO
NG NETW
O
N
G THE CO
N
R
ECOMM
E
C ECHO C
A
G
AIN AND
V
................
FACTORY
D
GLOSSAR
Y
a
llation U
s
N
STRUCTI
ION .........
................
T
S .............
W
...............
................
................
A
TION IN
S
T
ION .........
O
MMENDA
T
UNTING ....
TALLATION
N TO A NE
T
NNECTI
O
A
L NETWO
R
L
ocal Net
w
C
AL NETW
O
O
OR STATI
O
O
OR STATI
O
R STATIO
N
O
RK SETTI
N
N
NECTION
S
E
NDATIO
N
A
NCELLATI
O
V
OLUME A
D
................
D
EFAULTS
Y
...............
s
er Manu
a
Co
ONS ........
................
................
................
................
................
................
S
TALLATI
O
................
T
IONS ........
................
................
T
WORK .....
O
N SETTI
N
R
K PARAM
E
w
ork Para
m
O
RK PARA
M
O
N USING I
N
O
N WEB IN
T
NETWOR
K
N
GS OF PC
S
ETTINGS .
N
S ON SE
T
O
N ............
D
JUSTING ...
................
................
................
a
l
ntents
................
................
................
................
................
................
................
O
N ...........
................
................
................
................
................
N
G ............
E
TERS FOR
m
eters Wh
e
M
ETERS .....
N
TERNET
E
T
ERFACE...
K
SETTING
S
TO THE P
R
................
T
TING A
N
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
WIRED C
O
e
n Using
a
................
E
XPLORER .
................
S
THROUG
H
R
EVIOUS V
A
................
N
D OPER
A
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
O
NNECTION
a
Dynamic
................
................
................
H
THE WEB
A
LUES .......
................
A
TION OF
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
IP Addre
s
................
................
................
INTERFAC
E
................
................
DS05M(P
................
................
................
................
................
Cont
e
................
................
................
................
................
................
................
................
................
................
................
................
................
................
................
s
s .............
................
................
................
E
...............
................
................
) ...............
................
................
................
................
................
e
nts
1
.....2
.....4
.. 4
.. 5
.....6
.. 6
.. 7
...10
10
11
13
20
21
...22
22
26
29
33
33
37
39
42
...45
45
46
...48
48
48

Chapter 1. Safety Instructions
IP Video Door Station Installation User Manual 2
Chapter 1. Safety Instructions
Before using the product
This product complies with all safety rules. However, improper use of any electric device
can be a cause of fire and bring to property damage. Before you start using this door station,
please read this User Manual carefully.
ATTENTION!
Use accessories recommended by the manufacturer only. The use of the improper accessories may
cause device breakdown.
Follow the operating instructions
Do not use and store this door station in severe environment:
avoid extremely low or high ambient temperatures (the door station operating
temperature is -40°C to +50°C)
avoid exposure to direct sunlight and do not locate the door station near any heat
sources
do not locate the door station near any electrical appliances which can be
electromagnetic transmitters
avoid exposure to high vibration
ATTENTION!
In case of malfunction of the product contact our Service Center.
In case of:
detection of a strange smell or smoke
penetration of any liquid or foreign objects into the door station
the door station has been dropped or damaged
Do the following:
unplug the power cord and disconnect all other cords from the door station
contact our Service Center. You can find contact information on our website:
https://www.envirocams.com/tech-support/
Transportation
Ttransport the door station carefully, using the original box and protective packing.

Chapter 1. Safety Instructions
IP Video Door Station Installation User Manual 3
Ventilation
To prevent overheating of the device, keep free air circulation in the area where the door
station is located.
Cleaning
Use a soft, dry cloth for cleaning door station’s external surfaces. It is acceptable to use
some detergent for removing persistent dirt, but not the volatile cleaners such as the alcohol-
containing solvents, benzene and so on, because of the risk to damage the door station’s housing.

IP Video
I
P
area net
w
to start
u
do a si
m
advanta
g
D
provide
e
nearby t
e
electroni
low light
mechani
T
interface
supports
T
safer. In
2
Door Sta
t
P
Video D
o
w
ork with
o
u
sing the
d
m
ple setti
n
g
es of suc
h
D
S05M(P)
e
stablishin
e
rritor
y
an
d
c
locks, g
a
level the
c
al infrare
d
he DS05
M
. In case
o
PoE.
he Micro
S
case of di
s
.1. Key F
Image
s
Simulta
n
Frame
r
t
ion Insta
l
o
or Statio
n
o
ut using a
d
oor statio
n
n
g. Low
c
h
solution.
has a va
n
n
g video a
n
d
also co
n
a
rage doo
r
door stat
d
filter.
M
model
o
f DS05M
S
D memor
y
s
connecti
o
eatures
s
ensor: 1.
3
n
eous enc
r
ate: up to
l
lation Us
e
Ch
a
n
DS05M(
P
dditional
e
n
is to inst
c
osts, ea
s
n
dal resist
n
d audio
c
n
trol other
r
openers,
ion has a
is conne
c
power is
s
y
cards su
p
o
n all impo
3
MP, CM
O
oding: H.
2
25 fps for
a
e
r Manua
l
a
pte
r
2.
D
P
) is used
f
e
quipment,
all on you
r
sy
installa
t
Pic
.
ant housi
n
c
onnection
devices t
h
light swit
c
built-in i
n
c
ted to th
e
s
upplied fr
o
p
port impr
o
rtant data
a
O
S 1/3'' S
O
2
64/H264,
Н
a
ll resoluti
o
l
Descri
p
f
or buildin
g
such as
a
r
PC the s
t
ion and
r
.
2.1
n
g. Built-i
n
between
h
at can be
c
hes, alar
m
n
frared LE
D
e networ
k
o
m a DC
1
o
ves cam
e
a
re saved
O
NY Exmo
r
Н
.264/MJ
P
o
ns
p
tion
g
IP interc
o
a
separate
oftware fr
o
r
emote a
c
n
speaker,
the Guest
connecte
d
m
systems
D
with w
o
k
using t
h
1
2V powe
r
e
ra capabi
to the car
d
r
Day/Nig
h
P
EG, MJP
E
C
o
m syste
m
interior m
o
o
m the pa
c
c
cess to t
microph
o
and the
C
d
to the d
o
, etc. To
p
o
rk distan
c
h
e 10/100
B
r
source.
T
lities and
m
d
.
h
t
E
G /MJP
E
C
hapte
r
2.
m
based on
o
nitor. All
y
c
kage con
t
he devic
e
o
ne and I
P
C
lient, wat
c
o
or station
p
rovide op
e
c
e up to 1
B
ASE-TX
T
he DS05
M
m
akes its
o
G
Descripti
o
the local
y
ou need
t
ents and
e
are the
P
camera
c
hing the
, such as
e
ration at
0 m and
Ethernet
M
P model
o
peration
o
n
4
Fiel
d
Fiel
d
d
Code Chan
g
d
Code Chan
g
g
ed
g
ed

Chapte
r
2. Description
IP Video Door Station Installation User Manual 5
IR illumination distance up to 10 m and mechanical IR filter
MicroSD/SDHC memory card support up to 32 GB
Multi-streaming: up to 10 nonidentical streams (only one user can be in the two-way
audio mode at one time)
Built-in web server for viewing and setting
A built-in player for watching records
Built-in microphone and speaker
Power: DC 12V, 0.5A / PоE 802.3af Class 0 (for DS05MP only)
Operating temperature: -40°С to +50°С
Protocols supported: TCP/IP, IPv4/IPv6, UDP, HTTP, NTP, RTP, RTSP, DHCP, DNS,
DDNS, FTP, SIP, Modbus
ONVIF support
2.2. Package Contents
DS05M(P) door station
Bracket with mounting kit
Hexagonal socket screw with L-key
RJ45-S01 connector (2 pcs)
NC101 / NC101P / NC301P2 controller
Terminal block
CD with product documentation and software
ATTENTION!
Package contents and door station specification are subject to change without notice.

IP Video
3
A
1
2
3
4
provide
v
5
6
channel
7
surface.
Door Sta
t
.1. Door
S
A
door stati
o
– light s
e
– built-in
– IP cam
e
– IR LE
D
v
ideo surv
e
– call bu
t
– built-i
n
between t
h
– bracke
t
t
ion Insta
l
S
tation
o
n front vi
e
e
nsor: a p
h
microph
o
e
ra: allow
s
D
: the inf
r
e
illance pr
o
t
ton: a call
n
speaker
h
e Client
a
t
frame: c
o
l
lation Us
e
C
h
e
w is give
n
h
otoelectri
c
o
ne: allow
s
s
the Clien
t
r
ared ligh
t
o
cess at a
notificati
o
: combine
d
a
nd the Gu
o
mbined
w
e
r Manua
l
h
apte
r
3
.
n
below:
Pic
.
c
cell for
D
s
the Clien
t
to watch
w
t
-emitting
low light l
e
o
n is sent t
o
d
with the
est.
w
ith a bra
c
l
.
Overvi
.
3.1
D
ay/Night
m
t to hear
w
w
hat hap
p
diodes us
e
vel as w
e
o
the Clie
n
built-in
m
c
ket plate i
t
ew
m
odes aut
o
w
hat happ
e
p
ens in the
ed instea
d
e
ll as at ni
g
n
t when th
e
m
icrophone
t
fixes the
o
matic ch
a
e
ns in the
s
surveillan
c
d
of stan
d
g
ht.
e
Guest pr
e
it provid
e
door stati
o
Chapter
a
nging.
s
urveillanc
e
c
e.
d
ard elect
r
e
sses this
e
s a two-
w
o
n on the
3. Overvi
e
e
area.
r
ic lamps
button.
w
ay audio
mounting
e
w
6

IP Video
8
NC301P
2
9
seconds
1
board, fr
o
3
A
processi
n
door sta
t
A
T
which is
Door Sta
t
– RJ45
2
controll
e
– reset b
to set do
o
0
– mem
o
o
m one si
d
.2. Contr
o
A
door st
a
n
g the sig
t
ion.
A
1-channe
here is a
n
used for c
o
t
ion Insta
l
socket: i
s
e
r by a pat
c
utton: pr
e
o
r station s
e
o
ry card s
d
e.
o
lle
r
a
tion cont
r
nal of do
o
l or a 3-ch
n
RJ45 s
o
o
nnecting
l
lation Us
e
s
used fo
r
c
h cable.
e
ss this bu
t
e
ttings by
lot: is situ
a
r
oller is u
o
r opening
annel con
t
o
cket (ET
H
the contro
Pic. 3.
3
e
r Manua
l
Pic
.
r
connecti
t
ton 3 tim
e
default.
a
ted insid
e
u
sed for
p
and sign
a
t
roller can
H
ERNET)
ller to a ro
3
. Controlle
r
l
.
3.2
ng the d
o
e
s with int
e
e
the door
p
owering
t
a
ls of othe
r
be includ
e
on the fr
o
uter (
Pic.
3
r
NC101 /
N
o
or statio
n
e
rvals not
station h
o
t
he door
s
r
devices
t
e
d in the D
S
o
nt side
o
3
.3
).
N
C101P
n
to the
N
less than
1
o
using, on
s
tation, n
e
t
hat can b
S
05M(P)
p
o
f the doo
Chapter
N
C101 /
N
1
second
d
the upper
e
twork co
e connect
p
ackage c
o
r station
c
3. Overvi
e
N
C101P /
d
uring 10
interface
nnection,
ed to the
o
ntents.
c
ontroller,
e
w
7

IP Video
P
(or PoE i
A
1
controlle
connect
o
ATTEN
T
The pat
impossi
b
2
device c
o
Door Sta
t
P
ower ove
r
njector) s
u
A
rear view
– RJ45
s
r to the d
o
o
rs from th
T
ION!
ch cable
m
b
le to conn
e
– termin
o
ntroller. I
n
t
ion Insta
l
r
Ethernet
u
pported
P
of the do
o
s
ocket (E
T
o
or station
e packag
e
m
ust have
t
e
ct the doo
r
al conne
c
n
case of
c
l
lation Us
e
Pi
c
(PoE) is p
P
оE 802.3
a
o
r station c
Pic. 3.
5
Pi
c
T
HERNET
)
by a patc
h
e
contents
t
he RJ45-
S
r
station usi
n
c
tor (AL
A
c
onnectio
n
e
r Manua
l
c
. 3.4. Cont
r
rovided b
y
a
f Class 0.
ontroller i
s
5
. Controlle
r
c
. 3.6. Cont
r
)
: is used
h
cable. T
h
(see para
g
S
01 conne
c
n
g a cable
c
A
RM OUT)
n
to the 1-
c
l
r
oller NC30
1
y
the NC1
0
s
given on
t
r
NC101 /
N
r
oller NC30
1
for conne
c
h
e patch c
a
g
raph 4.5).
c
to
r
at the
c
onnector
o
: is used
c
hannel do
1
P2
0
1P or NC
3
t
he
Pictur
e
N
C101P
1
P2
c
ting the
N
a
ble need
s
end conn
e
o
f some oth
e
for conne
or station
3
01P2 co
n
e
s 3.5, 3.6
:
N
C101 /
N
s
to be ma
e
cted to th
e
e
r form.
cting a d
o
controller,
Chapter
n
troller an
d
:
N
C101P /
N
de using
R
e
door sta
t
o
or lock o
r
NC101 o
r
3. Overvi
e
d
a router
N
C301P2
R
J45-S01
t
ion! It is
r
another
r
NC101P
e
w
8
Fiel
d
d
Code Chan
g
g
ed

Chapter 3. Overview
IP Video Door Station Installation User Manual 9
(shown on the Picture 3.5), the signal opening the door outputs to the lock controller via «1A» and
«1B» pins.
ATTENTION!
Switching off - switching on the door station with the 1-channel controller (NC101 or NC101P) causes an
uncontrolled door lock opening. It happens because of peculiarities of the auto testing procedure which is
performed by the door station when it is switched on. Provide uninterrupted power supply of the door
station and the lock to prevent a door opening.
In case of the 3-channel door station controller, NC301P2, the signal opening the door
outputs to the lock controller via «1A» and «1B»/«1С», «2A» and «2B»/«2С», «3A» and
«3B»/«3С» pins for the first, the second and the third channel accordingly (Pic. 3.6). The «A» and
«B» pins are normally open, and the «A» and «С» pins are normally closed.
The «G» and «12V» pins of the NC101 controller (without PoE support) are used for DC
12V power supplying of the door station. It is necessary to connect a power supply recommended
by Enviro Cams and the lock controller to these pins.
The «G» and «12V» pins of the NC101P / NC301P2 controller (with PoE support) are used
for powering the lock controller (several lock controllers) with DC 12V. In this case it is necessary
to connect only the lock controller to these pins.
ATTENTION!
Use only DC 12V power supplies recommended by Enviro Cams!
Power supplying using both PoE and the «G» and «12V» pins (for NC101P and NC301P2 controllers) at
one time is prohibited!
ATTENTION!
Maximum current rate provided by the NC101P, NC301P2 controllers for powering door locks and their
controllers is 500 mA. If this value will be exceeded the device may operate incorrect and be damaged.
The device breakdown caused by the exceeding of the maximum current rate is not covered by the
warranty.

IP Video
4
T
switch).
T
manual.
Door Sta
t
.1. Gene
r
he door
s
he steps
t
t
ion Insta
l
C
h
r
al Infor
m
s
tation ca
n
t
o be don
l
lation Us
e
h
apte
r
4
.
m
ation
n
be conn
e and ins
t
e
r Manua
l
.
Door
S
ected dir
e
Pic
.
t
allation r
e
l
S
tation I
n
e
ctly to a
.
4.1
e
commen
d
Ch
a
nstallat
i
computer
d
ations ar
e
a
pter 4. D
o
i
on
or by m
e
e
given b
e
o
or Statio
n
e
ans of a
e
low in th
e
n
Installati
o
router (a
e
present
o
n
10

Chapter 4. Door Station Installation
IP Video Door Station Installation User Manual 11
4.2. Installation Recommendations
The present paragraph contains a short list of recommendations which are important for the
correct installation of DS05M(P).
IP Video Door Station DS05M is installed in the dry places on the surface of the inactive
leaf of exterior double doors or on the wall of the building. It is recommended to install the device
inside (vestibules, entrance halls), as far as possible, avoiding the outside installation. It is also
necessary to be convinced of possibility of free laying connection cables, when installing the door
station.
Install the door station in the well-lighted area avoiding exposure of the camera lens to
direct sunlight. The mounting height must be convenient for the Guest to talk with the Client. It is
recommended to install the door station at height of about 1.5 m above the floor.
Then it is recommended to provide the uninterrupted power supply of router, door station,
electronic lock and its controller.
Recommendations on door station placement:
The operating temperature range is -40°С to +50°С.
Avoid exposure to direct sunlight and do not locate the door station near any heat
sources.
Incorrect installation may cause undesirable “blind spots”, zones that are not visible to
the Client.
Do not locate the door station near any electrical appliances which can be
electromagnetic transmitters.
When installing the door station, be convinced of possibility of free laying connection
cables.
Avoid unstable installation, which may allow exposure to high vibration. This may reduce
motion detection performance and image crispness in whole.
The view direction should be clearly determined at the moment of the door station
installation.

Chapter 4. Door Station Installation
IP Video Door Station Installation User Manual 12
Recommendations on twisted pair cable routing:
In corridors, it is advisable to install electric and feeble-current cables in different
conduits that are disposed on different walls.
Twisted pair and electric cables can be installed in the same conduit using different
sections of the cable that have solid longitudinal partitions with at least 0.25 h of fire
resistance, which are made of non-combustible material and should be positioned in
work areas at distance of 15 meters maximum if the electrical power does not exceed 5
kW.
Electric and feeble-current cables should be placed in parallel to each other at distance
of at least 50 mm in different conduits or different sections of conduit. If the electric field
strength from the electric cables exceeds 3 V/m, you should increase the distance
between the electric and feeble-current cables or reduce the electromagnetic noise.
Twisted pair and electric cables should cross each other at right angles.
Unshielded twisted pair cables should be located at distance of at least 125 mm from
fluorescent gas-discharge lamps or from other high-voltage discharge devices.
Unshielded twisted pair cables should be located at distance of at least 1.5 meters from
electromagnetic interference sources that produce electric field strength exceeding 3
V/m.
Switchboards with pinned unshielded twisted pair cables should be located at distance
of at least 3 meters from electromagnetic interference sources that produce electric field
strength exceeding 3 V/m.
Entire twisted pair cables should be arranged between the points of connection so the
cable run is as short as possible.
Minimum cable bending radius is four times the cable diameter (or 1 inch=2.5 cm) or it is
also acceptable to install the cable so that the cable bending radius is 2 inches (5 cm).
Maximum length of the entire segment is 100 meters.

IP Video
4
ATTEN
T
If you a
r
Refer to
The me
m
F
S
floor. Th
e
S
the hole
s
S
The hea
d
2.5 mm
a
S
Door Sta
t
.3. Door
S
T
ION!
r
e going to
the paragr
a
m
ory card i
s
ollow the
s
S
tep 1: ta
k
e
recomm
e
S
tep 2: ma
r
s
.
S
tep 3: ins
e
d
s of som
e
a
nd not bi
g
S
tep 4: the
r
for hidd
e
the bott
o
for ope
n
channel
cable o
u
t
ion Insta
l
S
tation
M
use a me
m
a
ph 4.4 for
i
s
not includ
e
s
teps belo
w
k
e the bra
c
e
nded hei
g
r
k the hol
e
e
rt plastic
e
other sc
r
g
ger than
9
r
e are hid
d
e
n cabling
o
m of the
b
n
cabling
and the
b
u
tside (
Pic
.
l
lation Us
e
M
ounting
m
or
y
card
i
i
nformation
e
d in the p
a
w
:
c
ket plate
g
ht is abo
u
e
s on the
m
wall dow
e
r
ews you
u
9
mm in di
a
d
en and o
p
drill a hol
e
b
racket pl
a
fix a cab
l
b
ottom of
.
4.3
).
e
r Manua
l
i
n the doo
r
on memor
y
a
ckage con
t
(Pic. 4.2)
.
u
t 1.5 m.
m
ounting
s
Pic
.
e
ls in the
h
u
se (not fr
o
a
meter.
p
en ways
o
e
for twist
e
a
te. Leave
l
e channe
l
the brack
e
l
r
station, in
s
y
card insta
l
t
ents.
.
Choose
t
s
urface usi
.
4.2
h
oles and
f
o
m the pa
c
o
f cabling:
e
d pair ca
b
110 mm
o
l on the
w
e
t plate w
o
Ch
a
s
ert it befo
r
l
lation.
t
he right
h
ng the bra
f
ix the br
a
c
kage cont
e
b
le output
a
o
f the cabl
e
w
all so th
a
o
uld be 3
6
a
pter 4. D
o
r
e the doo
r
h
eight of
m
cket plate
a
cket plate
e
nts) mus
t
a
t the dist
a
e
outside.
a
t the dis
t
6
mm. Le
a
o
or Statio
n
r
station in
s
m
ounting
a
as a tem
p
using fou
t
be not hi
g
a
nce of 25
t
ance bet
w
a
ve 110
m
n
Installati
o
s
tallation.
a
bove the
p
late. Drill
r screws.
g
her than
mm from
w
een the
m
m of the
o
n
13

IP Video
S
using a
paragra
p
ATTEN
T
The pat
impossi
b
T
be wired
ATTEN
T
The dev
Use the
operatio
S
the door
the free
c
Door Sta
t
S
tep 5: att
a
crimping
p
h 4.5.
T
ION!
ch cable
m
b
le to conn
e
he twiste
d
the same
T
ION!
ice breakd
o
cable of
t
n of the de
v
S
tep 6: co
n
station in
c
able as it
t
ion Insta
l
a
ch the RJ
tool. For
m
ust have
t
e
ct the doo
r
d
pair cabl
e
at both e
n
o
wn caused
t
he minima
v
ice cannot
n
nect the c
the fram
e
is showe
d
l
lation Us
e
45-S01 c
o
more info
t
he RJ45-
S
r
station usi
n
e
(5е UT
P
n
ds (“straig
by wiring t
h
l possible
be guarant
rimped ca
b
e
to set th
e
d
on the pi
c
e
r Manua
l
Pic
.
o
nnector fr
o
rmation o
n
S
01 conne
c
n
g a cable
c
P
/FTP) co
n
ht-throug
h
h
e cable in
length to
c
eed in cas
e
b
le to the
d
e
appropri
a
c
ture belo
w
l
.
4.3
o
m the pa
c
n
how to
c
to
r
at the
c
onnector
o
n
nected th
e
h
” form).
different m
a
c
onnect th
e
e
of using o
f
d
oor statio
a
te view d
i
w
:
Ch
a
c
kage con
t
crimp a
t
end conn
e
o
f some oth
e
e
door st
a
a
nne
r
is no
t
e
door stati
o
f
the 10 m
c
n and put
i
i
rection of
a
pter 4. D
o
t
ents to th
e
t
wisted p
a
e
cted to th
e
e
r form.
a
tion with i
t
t
covered b
y
on and its
c
able and
m
i
t in the br
a
the built-i
n
o
or Statio
n
e
twisted
p
a
ir cable
g
e
door sta
t
t
s controll
e
y
the warra
n
controller.
m
ore.
a
cket fram
n
IP came
n
Installati
o
p
air cable
g
o to the
t
ion! It is
e
r should
n
t
y
.
Prope
r
e. Rotate
e
ra. Place
o
n
14

IP Video
S
to be fix
e
A
door sta
t
S
wall. Th
e
the brac
k
S
door sta
t
notches
(Pic. 4.6
)
Door Sta
t
S
tep 7: sp
e
e
d well an
d
A
view dire
c
t
ion install
a
S
tep 8: ap
p
e
n move t
h
k
et plate,
a
S
tep 9: en
s
t
ion, chec
k
fit each o
t
)
.
t
ion Insta
l
e
cific notc
h
d
prevent i
t
c
tion of th
e
a
tion (rota
t
p
ly the do
o
h
em down
a
nd there
s
s
ure that t
h
k
the joint
o
t
her. If the
l
lation Us
e
h
es of bra
c
t
s free rot
a
e
built-in I
P
t
ing angle
s
o
r station i
n
with force
s
hould not
h
e bracket
o
f the fixa
t
y don’t, c
h
e
r Manua
l
Pic
.
c
ket frame
a
tion durin
g
Pic
.
P
-camera
s
are ±45°
f
n
serted in
t
up to the
be any sp
a
is fixed w
e
t
ion notch
e
h
ange doo
l
.
4.4
and door
g
operatio
n
.
4.
5
must be
c
f
rom the
m
t
he brack
e
stop. The
a
ce betwe
e
e
ll. In cas
e
e
s. There
r station’s
Ch
a
station (
P
n
.
c
learly det
e
m
iddle posi
e
t frame to
bracket fr
a
en the fra
m
e
of a spa
c
must be n
position i
n
a
pter 4. D
o
P
ic. 4.5) all
o
e
rmined at
tion).
the brack
e
a
me shou
l
m
e and th
e
c
e betwee
n
o space b
e
n
side the
f
o
or Statio
n
o
w the do
o
the mom
e
e
t plate fix
e
l
d comple
t
e
wall.
n
bracket f
r
e
tween p
a
f
rame to fi
n
Installati
o
o
r station
e
nt of the
e
d on the
t
el
y
cover
r
ame and
a
rts, if the
t it better
o
n
15

IP Video
S
L-key fr
o
tighten t
h
S
tool as it
Door Sta
t
S
tep 10: fi
x
o
m the p
a
h
e secret
s
S
tep 11: at
t
described
t
ion Insta
l
x
the door
s
a
ckage co
n
s
crew up (
P
t
ach the
R
in the par
l
lation Us
e
s
tation insi
n
tents. To
P
ic. 4.7).
R
J45 conn
e
agraph 4.
5
e
r Manua
l
Pic
.
de the br
a
do so p
u
Pic
.
e
ctor to th
e
5
.
l
.
4.6
a
cket fram
e
u
sh the b
r
.
4.7
e
other en
d
Ch
a
e
using th
e
r
acket fra
m
d
of twist
e
a
pter 4. D
o
e
hexagon
a
m
e down
a
e
d pair ca
b
o
or Statio
n
a
l socket s
a
nd simul
t
b
le using a
n
Installati
o
crew and
t
aneously
crimping
o
n
16
Fiel
d
d
Code Chan
g
g
ed

IP Video
ATTEN
T
The twi
s
same a
t
different
S
NC101P
S
The rec
o
NOTE!
The NC
1
used in
c
1
I
n
external
Door Sta
t
T
ION!
s
ted pair c
a
t
both end
s
manner is
S
tep 12: c
/ NC301
P
S
tep 13: c
o
o
mmende
d
1
01P contr
o
c
ase of con
. Witho
u
n
this cas
e
12V powe
t
ion Insta
l
a
ble (5е UT
s
(“straight
-
not covere
d
onnect th
e
P
2 controll
e
o
nnect the
d
connecti
o
o
ller is sho
w
nection of t
u
t PoE (D
S
e
the door
r source.
l
lation Us
e
P/FTP) co
n
-
through” f
o
d
by the wa
r
e
crimped
e
r (Pic. 3.
5
door lock
o
n scheme
w
n on the
s
he NC301
P
S
05M pac
k
station, th
e
e
r Manua
l
n
nected the
o
rm). The
r
rant
y
.
cable to
5
, 3.6).
controller
t
s are give
n
s
chemes 2,
P
2 controlle
r
k
age cont
e
Pic
.
e
door loc
k
l
door stati
o
device bre
the RJ45
t
o the ter
m
n
below.
3 (Pic. 4.
9
r
.
e
nts):
.
4.8
k
and its
c
Ch
a
o
n with its
c
akdown c
a
socket (
E
m
inal block
9
, 4.10). Th
e
c
ontroller
a
a
pter 4. D
o
c
ontroller s
h
a
used by
w
E
THERNE
T
of the do
o
e
same sc
h
a
re supplie
o
or Statio
n
h
ould be wi
w
iring the
c
T
) of the
o
r station
c
h
emes can
d with po
w
n
Installati
o
red the
c
able in
NC101 /
c
ontroller.
be also
w
er by an
o
n
17

IP Video
ATTEN
T
Use onl
y
website
It needs
door sta
t
2
I
n
power s
o
ATTEN
T
Power s
one tim
e
Door Sta
t
T
ION!
y
DC 12V
p
(
https://w
w
to highlig
h
t
ion, doo
r
l
o
. With P
o
n
this cas
e
o
urce, but
t
T
ION!
upplying u
s
e
is PROHI
B
3. It is
power
s
control
l
schem
e
t
ion Insta
l
p
ower suppl
w
w.enviroc
h
t that the
m
o
ck and oth
e
o
E (DS05
M
e
the doo
r
t
he door s
t
s
ing both P
o
B
ITED!
available
s
ource) i
f
ler is no
t
e
is as follo
l
lation Us
e
ies recom
m
ams.com/
)
m
aximum
c
e
r equipme
M
P packa
g
r
lock and
t
ation use
o
E and the
to suppl
y
f
the tota
l
t
bigger t
ws:
e
r Manua
l
m
ended by
E
)
.
c
urrent rate
nt should n
o
g
e conte
n
Pic
.
its contro
PoE suppl
«G» and «
1
y
all usin
g
l
energy
c
han 500
l
E
nviro Ca
m
provided
b
o
t be exce
e
n
ts):
.
4.9
ller are s
u
ying.
1
2V» pins
(
f
g
devices
c
onsump
t
m
A
. In th
Ch
a
m
s! For rec
o
b
y the pow
e
e
ded.
u
pplied wi
t
f
or NC101
P
with PoE
t
ion of u
s
is case t
h
a
pter 4. D
o
o
mmendati
o
e
r source f
o
t
h power
b
P
and NC3
0
(without
u
s
ing elect
r
h
e recom
m
o
or Statio
n
o
ns please
v
o
r supplyin
g
b
y an ext
e
0
1P2 contro
u
se of an
r
onic loc
k
m
ended c
o
n
Installati
o
v
isit our
g
of the
e
rnal 12V
llers) at
external
k
and its
o
nnection
o
n
18

IP Video
T
NOTE!
The cur
r
moment
is reco
m
A
supports
which is
connect
ATTEN
T
Power s
one tim
e
ATTEN
T
Maximu
m
controll
e
The de
v
warrant
y
Door Sta
t
he all devi
r
ent rate of
e
of door op
e
m
mended to
A
Z-5R do
o
connecti
o
not show
n
a
dditional
T
ION!
upplying u
s
e
is PROHI
B
T
ION!
m
current r
a
e
rs is 500
m
v
ice breakd
o
y
.
t
ion Insta
l
ces use P
o
e
lectronic l
o
e
ning/closi
n
use an ext
e
o
r lock co
n
o
n of addi
t
n
on the s
c
equipmen
t
s
ing both P
o
B
ITED!
a
te provide
d
m
A. If this v
a
own cause
l
lation Us
e
o
E supplyi
o
cks specifi
n
g. It may c
e
rnal powe
r
n
troller is
u
t
ional equ
i
c
hemes. S
e
t
correctly.
o
E and the
«
d
by the N
C
a
lue will be
d by the e
x
e
r Manua
l
Pic.
ng on the
ed in their
d
ause some
r
source for
u
sed as a
n
i
pment (s
u
e
e the do
c
«
G» and «
1
C
101P, NC
3
exceeded
x
ceeding o
l
4.10
scheme a
b
d
ocumenta
t
problems
w
lock suppl
y
n
exampl
e
u
ch as ibu
c
umentati
o
1
2V» pins
(
f
301P2 con
t
the device
f the maxi
m
Ch
a
b
ove.
t
ion can be
w
ith door s
t
y
ing as it sh
e
in the sc
h
tton read
e
o
n on the
d
f
or NC101
P
t
rolle
r
s for
p
may opera
t
m
um curre
n
a
pter 4. D
o
exceeded f
o
t
ation oper
a
own on the
h
emes ab
o
e
r, opened
d
oor lock c
o
P
and NC3
0
p
owering d
o
t
e incorrect
n
t rate is n
o
or Statio
n
o
r short tim
a
tion. In thi
s
Pictures 4.
o
ve. This
c
door sen
o
ntroller y
o
0
1P2 contro
o
or locks a
n
and be da
ot covered
n
Installati
o
e at the
s
case it
8, 4.9.
c
ontroller
sor, etc.)
o
u use to
llers) at
n
d their
maged.
by the
o
n
19

Chapter 4. Door Station Installation
IP Video Door Station Installation User Manual 20
Step 14: using the crimped cable connect the RJ45 socket (ETHERNET) of the door station
controller (Pic 3.3, 3.4) straight to a PoE supported router or by means of a PoE injector if the
router does not support PoE (see schemes 2, 3).
If PoE is not used, then connect the RJ45 socket (ETHERNET) of the NC101 controller to a
router using the crimped cable and connect the «G» and «12V» pins of the controller with an
external DC 12V power source.
To prevent the door station malfunction use only equipment recommended by Enviro Cams.
4.4. Memory Card Installation
Do as follows to install a memory card.
Step 1: remove the 4 screws and open the split-type door station housing. The memory
card slot is situated on the upper interface board, on its back side.
Step 2: take the memory card in a way that its contacts are directed to the interface board
and to the slot and insert it in the slot; you should feel/hear a little click.
To eject the memory card from the slot press it to feel/hear a click and then it will be pushed
out by a spring.
NOTE!
Switch off the door station before installation/ejection of the memory card. The hot swap of a memory card
is not supported by the door station and may damage the equipment or cause a data loss.
Step 3: close the split-type door station housing and fix the 4 screws.
This manual suits for next models
1
Table of contents
Popular Intercom System manuals by other brands

STAMONY
STAMONY ST-DP-400 user manual

Bpt
Bpt XC/310 Instructions for use and installation

Akuvox
Akuvox C317S user manual

KOCOM
KOCOM KIP-501PM Manual for operation and installation

Dahua
Dahua DHI-VTO2202F-P quick start guide

Trigon Electronics
Trigon Electronics MiniGuard IID Installation and programming instructions