Please Read Before Operating Unit
Operating Manual
Service and All Spare Parts Available
The Eraser Company, Inc.
PO Box 4961
Syracuse, NY 13221, USA
Phone: (315) 454-3237
Fax: (315) 454-3090
Website: www.eraser.com
E-mail: info@eraser.com
Bench Glo-Ring®Infrared Heat Tool
p 2
Eraser Company Inc. • Syracuse, NY USA • Ph: 315-454-3237 • info@eraser.com • www.eraser.com • Fax 315-454-3090
ORDERING INFORMATION
Bench Unit:
AH2711........... Bench Glo-Ring heat tool 120V 60Hz
IH0129..........................Optional electrical footswitch
IH0073.....Additional or replacement workpiece rests
Guards:
IH6517............. One pair 1/2” (12.7mm) wire guards
IH3551................ One pair 1” (25.4mm) wire guards
IH3552 ............... One pair 2” (50.8mm) wire guards
IH3553 ................ One pair 3” (76.2mm) wire guards
IH0129.........................Optional electrical foot switch
Elements, continuous for units used as bench
models:
IH6515 ...............................1/2” (12.7mmø) diameter
continuous element 120V 50/60Hz
IH5511 ...................................1” (25.4mmø) diameter
continuous element 120V 50/60Hz
IH5512...................................2” (50.8mmø) diameter
continuous element 120V 50/60Hz
IH5513...................................3” (76.2mmø) diameter
continuous element 120V 50/60Hz
Element and Guard Sizes
Dimensions of internal diameter of elements in
closed position. Most elements are available in
intermittent and continuously rated duty cycles.
Intermittent elements heat up quicker and get hotter
than continuous elements.
NOTE: Continuous elements MUST be tted if unit
is to remain on for more than 2 minutes.
SPECIFICATIONS
Triple Element Bench Glo-Ring® Infrared Heat Tool
Power Output..............................................120V Unit
Fitted with 1/2" (12.7mmø)
Elements.................................................... 660 Watts
Fitted with 1" (25.4mmø)
Elements.................................................... 660 Watts
Fitted with 2" (50.8mmø)
Elements.................................................... 900 Watts
Fitted with 3" (76.2mmø)
Elements.................................................. 1080 Watts
Weight .............................120V units - 9 lbs. (4.1 Kg)
Size....................................... 15 1/2" x 5 1/2" x 9 5/8"
(394mm x 140mm x 244mm)
OPERATION
Elements open to allow entry of material.
TRIPLE ELEMENT
BENCHTOP GLO-RING®
INFRARED HEAT TOOL
p 3
Eraser Company Inc. • Syracuse, NY USA • Ph: 315-454-3237 • info@eraser.com • www.eraser.com • Fax 315-454-3090
TRIPLE ELEMENT BENCHTOP GLO-RING®INFRARED HEAT TOOL
OPERATING INSTRUCTIONS
SET-UP:
The Triple Element Benchtop Glo-Ring® Infrared
Heat Tool will come with 2 adjustable workpiece
rests. An optional footswitch is also available.
To set-up, rst install the quartz elements (sold
separately) into the heat sink sockets. Firmly grasp
the element near the base and gently insert the two
contact pins into the sockets of the heat sinks. Be
sure the elements are pushed in all the way. Any
combination of element sizes and heat sinks may be
utilized on the bench unit. After installing the desired
number of pairs of elements, install the wire guards
into the holes drilled on the tops of the heat sinks.
Then install the adjustable workpiece rests onto the
2 plates on either side of the heat sinks and adjust
them to the desired height to keep the workpiece in
the center of the elements.
If the optional electrical footswitch is being utilized
to open and close the elements plug this into the
unit after rst removing the black cap covering the
socket located on the right rear panel of the unit.
Plug the unit into the appropriate electrical supply.
OPERATION:
Turn the lighted On/O󰀨 switch on the left side of
the front panel to ON to apply heat to the quartz
elements. The elements on the triple element
model may be closed either by utilizing the lighted
switch located on the right side of the front panel,
or alternatively by use of the optional electrical
footswitch.
The temperature of each set of elements may be
varied independently by use of the 3 knobs located
under each set of elements.
With the elements open, insert the workpiece from
the side or top of the elements, close the elements,
adjust the element temperature, and pull or push
the material to be heated, through the elements,
resting the ends on the workpiece rests to keep the
workpiece central in the elements.
Open the elements when all material has been
heated and remove the workpiece from the top or
side of the elements.
NOTE: Continuous elements must be used when
utilizing the triple element model.
! CAUTION: The Bench Glo-Ring Infrared Heat
Tool in operation, generates signicant heat
and should be treated with respect. DO NOT
leave unit unattended when turned ON. When
changing elements, be sure unit is unplugged
from the power source and that the elements are
completely cooled to the touch. The elements
are manufactured from quartz glass. If dropped
or knocked sharply, they will break. If elements
are broken, replace immediately.
MAINTENANCE:
Keep unit clean at all times and ensure that
elements and wire guards are securely installed. No
cleaning should be required in normal usage. No
other maintenance is required.
TROUBLE SHOOTING:
If one or more elements do not heat, replace them in
pairs as a set.
IMPORTANT SAFETYINSTRUCTIONS
! WARNING: DO NOT OPERATE TOOL
UNTIL YOU HAVE READ THOROUGHLY,
AND UNDERSTAND COMPLETELY, ALL
INSTRUCTIONS, RULES, ETC. ON THIS
PAGE, AND IN THE OPERATING MANUAL.
WHEN USING ELECTRIC TOOLS, BASIC
SAFETY PRECAUTIONS SHOULD ALWAYS
BE FOLLOWED TO REDUCE RISK OF FIRE,
ELECTRIC SHOCK, AND PERSONAL INJURY,
INCLUDING THE FOLLOWING:
GROUNDING INSTRUCTIONS:
In the event of a malfunction or breakdown,
grounding provides a path of least resistance for
electric current to reduce the risk of electric shock.
This tool is equipped with an electric cord having an
equipment-grounding conductor and a grounding
plug. The plug must be plugged into a matching
outlet that is properly installed and grounded in
accordance with all local codes and ordinances.
Do not modify the plug provided – if it will not t the
outlet, have the proper outlet installed by a qualied
electrician.
TRIPLE ELEMENT BENCHTOP GLO-RING®INFRARED HEAT TOOL
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. The
green conductor with or without yellow stripes is
the equipment-grounding conductor. If repair or
replacement of the electric cord or plug is necessary,
do not connect the equipment-grounding conductor
to a live terminal.
Check with a qualied electrician or service
personnel if the grounding instructions are not
completely understood, or if in doubt as to whether
the tool is properly grounded.
Use only 3-wire extension cords that have 3-prong
grounding plugs and 3-pole receptacles that accept
the tool’s plug.
Repair or replace damaged or worn cord
immediately.
GENERAL INSTRUCTIONS:
KEEP WORK AREA CLEAN Cluttered areas and
benches invite accidents.
DON’T USE IN DANGEROUS ENVIRONMENTS
Don’t use power tools in damp or wet locations, or
expose them to rain. Keep work area well lighted.
ALWAYS USE SAFETY GLASSES Everyday
eyeglasses only have impact resistant lenses; they
are NOT safety glasses.
DON’T OVERREACH Keep proper footing and
balance at all times.
DISCONNECT TOOL before servicing; when
changing accessories, such as blades, wheels,
cutters, and like.
USE RECOMMENDED ACCESSORIES Consult
the operating manual for recommended accessories.
The use of improper accessories may cause risk of
injury to persons.
CHECK DAMAGED PARTS Before further use
of the tool, a guard or other part that is damaged
should be carefully checked to determine that it will
operate properly and perform its intended function
– check for alignment of moving parts, binding of
moving parts, breakage of parts, mounting, and
any other conditions that may a󰀨ect its operation.
A guard or other part that is damaged should be
properly repaired or replaced.
DO NOT EXCEED THE MAXIMUM MATERIAL
SPECIFICATIONS See catalog pages for
specications.
DO NOT OPERATED UNIT WITHOUT GUARDS IN
PLACE OR GUARDS NOT IN WORKING ORDER.
DO NOT PERFORM MAINTENANCE OR
ADJUSTMENTS WITH POWER ON.
DO NOT PLACE FINGERS OR APPENDAGES IN
OR NEAR OPENINGS IN GUARDS.
DO NOT RUN UNIT WITH INCORRECT LINE
VOLTAGE. REFER TO LABEL PLACED OVER I/O
SWITCH.
DO NOT ALLOW UNTRAINED OR UNQUALIFIED
PERSONNEL TO OPERATE UNIT.
DO NOT DEFEAT ANY OF THE SAFETY
FEATURES DESIGNED INTO THE UNIT.
IMPORTANT: NO LIABILITY WILL BE INCURRED
BY THE ERASER CO. FOR INJURY, DEATH, OR
PROPERTY DAMAGE CAUSED BY A PRODUCT
WHICH HAS BEEN SET UP,OPERATED,AND/OR
INSTALLED CONTRARYTOERASER’SWRITTEN
INSTRUCTION MANUAL, OR WHICH HAS BEEN
SUBJECTED TO MISUSE, NEGLIGENCE, OR
ACCIDENT, OR WHICH HAS BEEN REPAIRED
OR ALTERED BY ANYONE OTHER THAN
ERASER, OR WHICH HAS BEEN USED IN A
MANNER OR FOR A PURPOSE FOR WHICH THE
PRODUCT WAS NOT DESIGNED.
p 4
Phone: (315) 454-3237
Fax: (315) 454-3090
Website: www.eraser.com
E-mail: info@eraser.com
The Eraser Company, Inc.
PO Box 4961
Syracuse, NY 13221, USA
IR8441
REV 08/21

Popular Heating System manuals by other brands

irsystem PRIMAVERA NEO HK1 Operation manuals

irsystem

irsystem PRIMAVERA NEO HK1 Operation manuals

Valeo thermo plus 300 Operating and service instructions

Valeo

Valeo thermo plus 300 Operating and service instructions

Valeo Thermo AC 070 Workshop manual

Valeo

Valeo Thermo AC 070 Workshop manual

Viessmann VITOVENT 300 operating instructions

Viessmann

Viessmann VITOVENT 300 operating instructions

Bryant HRVBBLHU Installation, start-up, and operating instructions

Bryant

Bryant HRVBBLHU Installation, start-up, and operating instructions

BPC VORTICE VORT HR 250 NETI Instruction booklet

BPC

BPC VORTICE VORT HR 250 NETI Instruction booklet

DEVI Thin mats installation guide

DEVI

DEVI Thin mats installation guide

Heidolph HB 4000 digit instruction manual

Heidolph

Heidolph HB 4000 digit instruction manual

General Pipe Cleaners Hot-Shot 320 operating instructions

General Pipe Cleaners

General Pipe Cleaners Hot-Shot 320 operating instructions

Lincar Alice 480N Using instructions and maintenance

Lincar

Lincar Alice 480N Using instructions and maintenance

Dometic Kohler 7APU Operation and installation

Dometic

Dometic Kohler 7APU Operation and installation

EC POWER BW 4+ manual

EC POWER

EC POWER BW 4+ manual

Alnor HRU-SlimAIR-250 user manual

Alnor

Alnor HRU-SlimAIR-250 user manual

Broan HRV200 ECM installation guide

Broan

Broan HRV200 ECM installation guide

Vortice VORT HR 300 NETI Instruction booklet

Vortice

Vortice VORT HR 300 NETI Instruction booklet

Fröling Lambdamat LM 1500 KOM installation instructions

Fröling

Fröling Lambdamat LM 1500 KOM installation instructions

Nibe UKV 100 installation instructions

Nibe

Nibe UKV 100 installation instructions

S&P CADB-N 05 PRO-REG Installation manual and instructions for use

S&P

S&P CADB-N 05 PRO-REG Installation manual and instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.