Ergomotion 3160 Series User manual

Actual product appearance and functionality may vary from photographs, illustrations and descriptions included in this manual.
OWNER’S MANUAL
3160 Series

table of contents
Safety Precautions and Usage Statements ....................................................................... 1-4
Parts List ..................................................................................................... 5
3160 Wireless Base and Remote Overview and Quick Reference Guide ..............................................6-7
3160 Wired Base and Remote Overview and Quick Reference Guide ................................................8-9
Installation Guide ............................................................................................10-11
Remote Control Pairing.........................................................................................12
Battery Backup Box ............................................................................................13
Syncing Two Bases...........................................................................................14-15
Connecting Strap ..............................................................................................16
Headboard Brackets ...........................................................................................17
Troubleshooting ...............................................................................................18
Spanish ...................................................................................................19-23
Notes .....................................................................................................24-25

1
SAFETY
TO REDUCE THE RISK OF SHOCK, BURNS, FIRE OR INJURY
For optimal safety and operation, plug bed base into a surge protector (not
included). The bed base should only be plugged directly into a wall outlet or
surge protector (strongly recommended). Always unplug the base from the
electrical outlet before servicing any part of the base. To reduce risk of electric
shock, unplug the base before cleaning. To safely disconnect, ensure the
base is in a at position with all motors o, and unplug from power source.
Keep the power cord away from heated surfaces. Never operate the base
when the air openings are blocked. Keep air openings free of lint, hair and
the like. Do not drop or insert any object into any opening. Discontinue use
of the bed base and contact a qualied service center if: it has a damaged
cord or plug, if it is not working properly, or it has been dropped into water.
Only use this bed base for its intended use as described in this manual.
Do not use accessories/attachments that are not recommended by the
manufacturer. Close supervision is required when the bed base is used by or
near children, convalescents, disabled persons or pets. Improper connection
of the equipment can result in the risk of electrical shock, electrical re or
faulty operation of this bed base. If the plug does not t your outlet, contact
a qualied electrician to install a suitable outlet. Unauthorized modication or
failure to use a wall outlet or surge protector could void the electrical portion of
your warranty.
PETS AND CHILDREN
Immediately dispose of all packing materials as it may pose a smothering risk
to small children and pets. To avoid injury, it is not advised to allow children
and small pets to play on or under the bed. Children should not operate the
bed base without adult supervision.
PACEMAKERS
Some products contain Neodymium MAGNETS, which may interfere with
devices such as pacemakers, ICD’s and any other device sensitive to magnetic
elds. It is STRONGLY recommended that owners of such medical devices
consult their physician prior to using products that contain Neodymium
MAGNETS. It is also possible that some pacemakers may falsely interpret the
optional massage feature vibrations as movement/exercise. This is a common
occurrence with any product that creates a vibrating movement and may not
aect the pacemaker. Please consult your physician before using the massage
feature.
Attention: Important Safety Disclaimers
Read the following information before using this product. Failure to use a surge protection device could
compromise safety or cause product malfunction and could void the electrical portion of your warranty.
safety precautions and usage statements
WARNING
Always unplug the base from the electrical outlet before servicing any
part of the base. To reduce risk of electric shock, unplug the base
before cleaning. To safely disconnect, ensure the base is in a at
position with all motors o, and unplug from power source.
WARNING
• Keep bed in a flat position when not in use.
• Stay clear of moving parts while in motion.
• Before adjusting, make sure children and pets are clear of
moving parts and are not under bed base.
• Do not allow children to operate bed base without adult
supervision

2
IN-HOME USE AND HOSPITAL STANDARDS
Ergomotion adjustable bed bases are designed solely for in-home use. This
base was not designed as a hospital bed and is not designed to meet hospital
standards. Do not use this base with TENT TYPE oxygen therapy equipment or
near explosive gases.
ADDITIONAL SAFETY FEATURES
Casters (optional leg accessory) are equipped with locking wheels to prevent
unwanted movement. Even when locked and unable to roll, it is possible for
the casters to slide. Free release head and foot motors are designed to lower
the mattress by retracting only with gravity, never pulling downwards, which
minimizes pinch points.
ACOUSTICS
LIFTING/LOWERING MECHANISMS
The lift/lower feature will emit a minimal humming sound during operation. This
is normal. During operation, the lift arm wheels make contact with the platform
support of the base. This contact may result in metal on metal or metal on
plastic contact. This applies slight tension on the moving components and
resonance is reduced to a minimum level. If excessive noise or vibration is
experienced, reverse the movement action (up or down) of the base with the
remote control. This should realign the base’s activating mechanisms to the
proper operational position. In normal base operation, the wheels, which allow
the bed to maintain its distance from the wall, will make contact with the steel
platform supports of the base creating a contact noise. When entering, exiting
or shifting weight on the base, this contact noise may be audible as the wheels
make contact. This is normal.
MATERIALS
Ergomotion adjustable bases are constructed from various materials including
woods, metals, plastics and fabrics. Tension, pressure or movement applied
to the frame, platform or shroud through general use may create an audible
sound.
TOLERANCE
All Ergomotion adjustable
foundations, depending on
make and model, are designed
and manufactured to perform
and function within designated
quality control parameters.
Bases are subject to meticulous
and rigorous inspections during
the quality control process to
ensure bases will operate within
these standards during normal operating use. Normal operating use is dened
as the following: Adjustable foundation is to be operated with a mattress
and load. Testing procedures require lifetime cycle tests with up to 120 kg
distributed load. The angle (designated “a” in gure 1) between the back
section and the at section for various congurations of the mattress support
platform shall be ± 3°, which translates to a tolerance of up to 1 ½”.
The angle (designated “b” in gure 1) between the at section and foot section
for various congurations of the mattress support platform shall be ± 3°, which
translates to a tolerance of up to ¾”.
Any adjustable foundation deemed to be within these allocated tolerances is
considered to have met the manufacturer’s quality control standards.
safety precautions and usage statements
Adjustable
Bed Tolerance
Ergomotion Inc. | ph 1-888-550-3746 | fx 805-979-9399 | www.ergomotion.com
All Ergomotion adjustable foundations, depending on make and model, are designed and manufactured to perform and
function within designated quality control parameters. Bases are subject to meticulous and rigorous inspections during
the quality control process to ensure bases will operate within these standards during normal operating use.
Normal operating use is defined as the following:
-Adjustable foundation is to be operated with a mattress and load. Testing procedures require lifetime cycle
tests with up to 120kg distributed load.
The angle (designated “α” in figure 1) between the back section and the flat section for various configurations of the
mattress support platform shall be ± 3°, which translates to a tolerance of up to 1 ½”.
The angle (designated “β” in figure 1) between the flat section and foot section for various configurations of the mattress
support platform shall be ± 3°, which translates to a tolerance of up to ¾”.
Any adjustable foundation deemed to be within these allocated tolerances is considered to have met the manufacturer’s
quality control standards.
(α°)
(β°)
When operating a "paired" split base setup there may be a time latency up to 1.5 seconds between each bases articulation.
Blake Pettit
Quality Assurance Manager
Ph 805-979-3875
Fx 805-979-9399
www.ergomotion.com
WARNING
For optimal safety and operation, plug bed base into a surge protector
(not included). The bed base should only be plugged directly into a
grounded wall outlet or surge protector (strongly recommended). Improper
connection of the equipment can result in the risk of electrical shock,
electrical file or faulty operation of this bed base. If the plug does not fit
your outlet, contact a qualified Electrician to install a suitable outlet.

3
THAT “NEW PRODUCT” SMELL
Some people notice a slight odor to their new adjustable base. This can come
from our material manufacturing process and the smell normal and usually
disappears before the product reaches you. Sometimes, however, this smell
may still be noticeable. It usually disappears after a few weeks, providing
adequate ventilation of the product and the environment.
BREAK IN PERIOD
You can speed up the break-in period by simply spending time in the
adjustable bed through activities such as reading, watching TV or playing
with the kids or grandkids. The extra movement will help the adjustable base
respond to weight and temperature changes. Some of the materials in our
adjustable bases such as the woods, metals and plastics used in the platform,
frame and components are sensitive to moisture content and temperature and
may make sounds in colder environments.
PAIRED OPERATION
When operating a “paired” split base setup there may be a time latency up to
1.5 seconds between each bases articulation.
WEAR AND TEAR
Wear and tear is damage that naturally and inevitably occurs as a result of
normal use or aging.
FABRIC CARE
To prolong the life of your fabric, protect from direct sunlight whenever possible.
For spot cleaning, wipe area with a light damp sponge or vacuum with a soft
brush attachment to remove particles. Keep at a minimum of 30 cm (12 inches)
away from direct heat sources. For a deeper cleaning, blot liquid spills with a
clean dry cloth. Wipe with a clean cloth dampened with warm water. Do not wet
excessively. A soft bristle brush may be used to remove ingrained soil. Avoid
scratching by gentle brushing. Wipe with a clean cloth dampened with warm
water to remove residues. Dry in shade away from direct heat. If persistent
marks remain visible after cleaning, seek professional advice.
PRODUCT RATINGS
The lift motors are not designed to operate continuously for more than two
(2) minutes in an eighteen (18) minute time period or approximately 10% duty
cycle. Attempting to circumvent or exceed this rating will shorten the life
expectancy of the product and may void the warranty.
WEIGHT LIMITS
This product is not rated to support weights in excess of 650 pounds inclusive
of the mattress and bedding. The base will structurally support this weight,
provided it is evenly distributed across the bed base. The adjustable base is
not designed to support or lift this amount in the head or foot sections alone.
Exceeding this weight restriction could damage the bed and/or cause injury
and will void the warranty.
FCC Compliance:
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesired operation.
To comply with the FCC RF exposure requirements, no
change to the antenna or the device is permitted. Any
change to the antenna or the device could result in the
device exceeding the RF exposure requirement and void
user’s right to operate the device.
Radio Frequency: 2.4 GHz
safety precautions and usage statements

4
IMPORTANT DO’S AND DON’TS
DO:
• Plug your adjustable base into a power surge protector.
• Evenly distribute weight when sleeping in a split setup (uneven distribution
of weight can cause the base to lift unevenly).
• Call Customer Service for any technical issues. Do not try to force the base
down (this can damage the motors or frame).
• Use mild soap and water to clean your adjustable base if staining occurs.
• Keep in mind that adjustable bases are recommended to be used with
adjustable friendly mattresses.
• Lower to the at (horizontal) position after use and in between presets.
• Enter or exit your adjustable in the at (horizontal) position.
• Register your warranty as soon as your adjustable base has been delivered.
DON’T:
• Sit on corners/edges of base (this may warp the frame, struts or foam).
• Tilt the base on its side (this can damage the legs and/or leg screws).
• Stand or jump on the adjustable base at any time (this can damage the
frame and motors).
• Drag the base to move it. Purchase castors if you plan on moving your
base routinely. (Dragging the base could damage the frame, strip the nut/
bolts or break the legs.)
• Enter and exit the adjustable base with the head and/or foot in the
articulated position.
• Tinker with or modify base.
• Press down on the head or foot while actuated, this can damage the frame
and motors.
safety precautions and usage statements
SAVE THESE INSTRUCTIONS.

5
parts list
All electronics and components that need to be installed are
located in boxes under the base or attached to the frame.
A) Wireless Remote Control and AAA Batteries (3)
or
Wired Remote
B) Mattress Retainer Bar *
C) Legs (6)
D) Power Cord
E) Power Supply
F) Battery Backup Box
G) SmartSyncTM Cord ‡*
or
Y-Cord ‡*
H) Connecting Strap ‡
Recommended Parts (not included):
I) Surge Protector
* These items are attached to the base for shipping purposes.
Carefully remove from base and set aside.
‡ Only included in Twin Long, and CA King Split Bases.
Before discarding the packing materials, ensure all the parts are accounted for.
(Remote may vary based on model)
or
A) B)* C)
D) E) F)
G)‡* H)‡I)

6
3160 wireless base and remote overview
Head Motor
Lifts foot portion
of the base.
Lifts head portion
of the base.
Lowers foot
portion of the
base.
Lowers head
portion of the
base.
FLAT position
Foot Motor
Control Box

7
3160 wireless base quick reference guide
Not to scale. For illustration purposes only. Read all instructions before beginning installation.
Power Cord
Power Supply
Head MotorFoot Motor
Control Box
ELECTRONICS OVERVIEWCONTROL BOX OVERVIEW
Input
Power Cord
To remove control box, release
metal clip and unplug cords.
If installing a split unit, please see page 14.
Multifunction
Port
Input Power
Cord Port
Power
LED Light
Head Motor
Port
Foot Motor
Port
Wireless
Remote
Reset
Button

8
3160 wired base and remote overview
Head Motor
Lifts foot portion
of the base.
Lifts head portion
of the base.
Lowers foot
portion of the
base.
Lowers head
portion of the
base.
FLAT position
Foot Motor
Control Box

9
3160 wired base quick reference guide
Not to scale. For illustration purposes only. Read all instructions before beginning installation.
Power Cord
Power Supply
Head Motor
Foot Motor
Control Box
ELECTRONICS OVERVIEWCONTROL BOX OVERVIEW
Input
Power Cord
To remove control box, release
metal clip and unplug cords.
If installing a split unit, please see page 15.
Wired Remote
Port
Multifunction
Port
Power
LED Light
Wireless
Remote
Head and Foot
Motor Ports

10
Always use two people when setting up the base.
For customer support, visit www.ergomotion.com or call: 888-550-3746
STEP 1
STEP 2
With the help of an able-bodied assistant, place the box on the
oor with the top of the box facing up.
Remove the binding straps and packing materials, making sure
not to puncture the box with any sharp objects.
Remove the bed base from the box. Unfold the base while
keeping the bottom of the base facing upwards.
To install the legs, thread the washer over the screw on the leg.
Next, screw the leg into the nutsert on the frame.
Do not over tighten.
STEP 4
STEP 5
Uncoil input cord (connected to control box’s
power port) and plug into power supply.
To sync two bases, see page 14-15.
To install headboard brackets (sold separately)
see instructions on page 17.
Locate the battery backup box.
Store the battery backup box in a
convenient location for emergency use.
For operating instructions, see page 13.
The 3-in-1 legs untwist into separate sections for custom leg
height options.
STEP 3
installation guide

11
installation guide
For customer support, visit www.ergomotion.com or call: 888-550-3746
STEP 6
Uncoil the Power Cord and connect to the
Power Supply. Place Power Supply on the
ground and extend from the base. Ensure
that the Power Supply and all attached
cords are directed toward the desired
surge protector.
STEP 7
STEP 8
STEP 9
STEP 10
Carefully ip the base over onto its legs.
Important: Always use two people when setting up, moving or
ipping the base. Do not drag across the oor. Do not rest frame on
its side, excessive pressure may damage the legs.
Setup is now complete! Test all functions on remote.
Slide the left side of the mattress retainer bar into the bracket.
Pull the retainer bar to the opposite bracket and secure the
right side.
WARNING
Always unplug the base from the electrical outlet before servicing any
part of the base. To reduce risk of electric shock, unplug the base before
cleaning. To safely disconnect, ensure the base is in a at position with
all motors o, and unplug from power source.
Plug the base into a power source. A surge protector is
strongly recommended.
Ensure batteries are correctly installed in the back of the
remote.
Quickly test functions to verify proper setup before placing
mattress on base. Press FLAT to return the base to a at
position.

12
remote control pairing
Remote Pairing
PAIR
Button
Test all remote functions. If the remote buttons do not impact the adjustable base movements, please repeat the process again.
STEP 1 STEP 2
The original remote that comes in the box is already paired to the adjustable base. No further action is required. In the event that the
remote is not paired with the base, follow the steps below.
On the back of the remote, press
and hold the PAIR button. The
PAIR button will illuminate blue
and start ashing. When the PAIR
button stops ashing, the green
LED light on the control box will
go out. Release the PAIR button.
The remote is now paired to the
adjustable base.
Locate the control box and
press the Reset button twice.
A green LED light will
illuminate on the Control Box.
STEP 3
Reset
Button
Power
LED Light
For customer support, visit www.ergomotion.com or call: 888-550-3746

13
emergency battery backup box
Store the battery box in a convenient location for emergency use.
(4) 9 Volt batteries are required to operate the power down feature and are NOT included.
For emergency use only, in case of a power outage.
In the event that the base is stuck in an articulated position during a power outage, the battery
backup box will return the base to a at position. Batteries are not to be used for normal operation
of the base.
Remove the battery box after the emergency is over, as the system will continue to draw power
from the batteries, even if not in use.
Install the 9 volt batteries into the provided battery pack.
Do not mix brand name batteries.
Connect battery pack to input power cord attached to control box.
OVERVIEW
STEP 2STEP 1
Input
Power Cord Control Box
Battery
Backup Box
If the base is in the upright position use the remote to return to a
at position.

14
syncing two wireless bases (optional)
STEP 3
STEP 2
STEP 1
STEP 4
STEP 5
A Sync Cord is included with Twin Long and CA King Split bases.
The Sync Cord connects the two control boxes to a single remote for the synchronization of two bases.
Locate the Multifunction Port on each control box.
Plug bases back into the power source.
If bases become mismatched, pressing the FLAT button will re-
sync the mechanical positions.
Connect the male end of each Sync Cord to the multifunction
port on each control box.
Check to ensure all cords are securely attached. Both remotes
will now operate both bases simultaneously.
Unplug bases from power source.
PERFORMANCE NOTES
Sync Cord
Control Box 1 Control Box 2
The system is now linked. Buttons pressed on either remote
will control both bases simultaneously.

15
syncing two wired bases (optional)
STEP 3
STEP 2
STEP 1
STEP 4
A Y-Cord is included with Twin Long and CA King Split bases.
The Y-Cord connects the two control boxes for the synchronization of two bases.
Plug bases back into the power source.
If bases become mismatched, pressing the FLAT button will re-
sync the mechanical positions.
Connect the male end of each Y-Cord to the multifunction port
on each control box.
Check to ensure all cords are securely attached. The
connected remote(s) will now operate both bases
simultaneously.
Unplug bases from power source.
PERFORMANCE NOTES
The system is now linked. Buttons pressed on either remote
will control both bases simultaneously.
Control Box 1 Control Box 2
Wired
Remote

16
With the bases in their desired location, slightly loosen both legs
to allow the strap to t on the leg bolt, between the leg washer
and frame.
Slide side (a) of the connecting strap onto leg bolt. Swing the
strap and connect side (b) to the leg bolt. Secure the strap by
shifting to the left.
Re-tighten legs. Do not over tighten. Use the remaining strap
and repeat on other end of the base.
STEP 2
STEP 1
STEP 3
connecting strap (optional)
ab
If a split setup is being installed, plastic connecting straps are provided with
Twin Long and CA King Split bases.
Use of the connecting straps is optional and is not required.

17
headboard bracket installation guide (optional)
STEP 1
a.) Align the bracket and to the holes in the frame with the tabs
facing outward. Loosely secure the bracket to the leg post
with two bolts, nuts and washers.
b.) Loosely secure the bracket to the frame with one bolt, nut
and washer. The bracket can be moved forward or backward
to adjust spacing between the head of the base and the
headboard.
Once the bracket has been spaced to accommodate the
headboard, secure and tighten the bolts, nuts and washers.
Headboard Brackets are an optional accessory.
A 9/16” (14 mm) & 1/2” (13 mm) socket and crescent wrench are necessary to complete installation.
a
b
a
b
STEP 2
Attach the plastic spacer and T-Bracket.
a.) Measure the distance between the mounting holes on the
headboard and install the spacer and attachment plate to
accommodate the headboard.
b.)To install the plastic spacer and attachment plate, you
will need (2) long bolts and (2) nuts. Place the spacer and
attachment plate in the desired location and slip the bolts
through the holes with the head of the bolt facing outward.
Position the bolts diagonally on the spacer. Use the 9/16” (14
mm) socket and wrench to tighten the bolts.
You may now connect your headboard to the attachment plates
using the remaining short bolts and nuts to secure it to the
brackets. The heads of the bolts will face outward. Use a 9/16"
(14 mm) socket and 1/2" (13 mm) wrench to tighten the bolts.
STEP 3

18
troubleshooting
• Check under the bed base to verify that the wired connections are secure and that there are no cords or bedding obstructing
the movement of the base.
• Check to ensure the green LED light is illuminated on the power supply. If there is no light, verify that the input and power cords
are properly connected.
• Unplug the base for 1 hour to reset the electronic components.
• Plug bed base into a dierent electrical outlet, or test current outlet with another working appliance (a grounded, electrical surge
protector is recommended).
If issue is not resolved by following the instructions above, locate serial number on warranty card or back of remote and call
Ergomotion Customer Service: 888-550-3746
If one or more functions on the bed base have stopped operating:
Table of contents
Other Ergomotion Medical Equipment manuals
Popular Medical Equipment manuals by other brands

CYMEDICA Orthopedics
CYMEDICA Orthopedics QB1 user manual

GE
GE MAC 800 Service manual

Prius Healthcare USA
Prius Healthcare USA Duet user manual

Braun
Braun Aesculap Spine Instructions for use/Technical description

LEADING CHAIR
LEADING CHAIR E-400 Instructions for use

TytoCare
TytoCare TytoPro quick start guide