esera automation PRO 11148 User manual

Art. No. 11148
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de 11148 V2.0 R1.0 Manual Page 1 of 4
User Guide
Temperature Sensor PRO
for 1-Wire Bus system
Professional temperature sensor for
private, schools, public buildings and
companies
Highly accurate temperature sensor with
12 Bit resolution
Universal surface mounting
Shapely and high-quality sensor housing
Connection by screw-terminals
Simple power supply
Application:
temperature sensor for heating control
(individual room control)
Control sensor for ventilation system
1 Introduction
Before you start assembling the Temperature Sensor Pro and before you take the device into
operation, please read these assembly and operating instructions carefully to the end, especially the
section referring to the safety notes.
2 Product description
With the Temperature Sensor Pro a simple monitoring of room and building temperatures is possible. The sensor
is installed in a shapely surface-mounted housing and fits very well into modern living rooms.
Due to the generous ventilation openings, the temperature sensor detects the ambient temperature very well.
An accurate temperature sensor is an important actual value transmitter for all types of radiator and heating
controls.
In combination with 1-Wire ESERA switching modules / binary outputs, a very effective and energy-saving
heating control (individual room control) is possible.
A calibration of the temperature sensor is not necessary. The Pro Temperature Sensor can be put into operation
immediately without any waiting time.
The Temperature Sensor Pro is equipped with screw terminals for the electrical connection of the 1-Wire Bus
interface and can be operated in standard mode (3-cable, for ground, 5V and data) or in parasitic mode.
Each temperature sensor has an individual serial number. The temperature sensor (DS18B20) has a high
resolution of 12 bits (0.06°C).

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de 11148 V2.0 R1.0 Manual Page 2 of 4
3 Auto-E-Connect® Support
The ESERA Auto-E-Connect® 1-Wire Plug and Play system will be used for the
1-Wire Bus supported. This enables fully automatic configurations of 1-Wire sensors
and actuators on the 1-Wire bus. It is optimized for industrial applications and
enables significant added value beyond the sensor and chip data.
The Auto-E-Connect function automatically recognizes ESERA chips, sensors and actuators, starts suitable
libraries and outputs fully formatted data.
The Auto-E-Connect functionality will be available from mid 2020 via 1-Wire Controllers, 1-Wire Gateways and
1-Wire ECO from ESERA available.
Further information on ESERA Auto-E-Connect can be found on the ESERA website, ESERA Config-Tool 3, or in
the download area for this article in the ESERA Webshop.
4 Technical data
1-Wire device: DS18B20 temperature sensor
Measuring range: -40°C to +60°C for entire 1-Wire Temperature Sensor Pro, limit values of temperature
range through sensor housing
Resolution: 12 Bit
Operating voltage: 3V to 5,5VDC
Current consumption: max. 1 mA
Accuracy: +/- 0,5°C in the range of -10°C to 85°C
Resolution temperature: 9 - 12 Bit, 0,5°C to 0,0625°C/ Bit, depending on selected resolution
5 Ambient Conditions
Protection type: IP20
Protection class: III
Temperature, operation: -25°C to 80°C, (limitation by carrier system, sensor -40°C to +125°C)
Air Humidity: 10 - 90% (non-condensing)
Outside dimensions: 80 x 80 x 29mm (LxWxH), suitable for mounting on flush-mounted boxes
6 Conformity
EN 50090-2-2
EN 61000-4-2, ESD
EN 61000-4-3, HF
EN 61000-4-4, Burst
EN 61000-4-5, Surge
EN 61000-6-1, Fault-free operation
EN 61000-6-3, Stray radiations
RoHS
7 Software / Control
The device is read by 1-Wire command for DS18B20 devices. The device is supported in many
computer programs like ESERA-Station Loxone, IP-Symcon, OWFS, FHEM, (Linux) or microcontroller
applications.
8 Control by 1-Wire Controller / 1-Wire Gateway
The 1-Wire interface of the 1-Wire temperature sensor Pro is controlled by standard commands for the
device DS18B20. The 1-Wire Controller / 1-Wire Gateway has already stored a suitable formula for the
conversion of the raw data of the 1-Wire block. It is not necessary to assign an OWD number.
8.1 Data output 1-Wire Controller / 1-Wire Gateway
For the ESERA-Automation 1-Wire temperature sensor Pro, the following data are output. If you divide
the value by 100, you get the data with two decimal places.
Data output:
1_EVT|10:29:35
1_OWD1|2401=> Controller No._device No._data record|temperature (°C) example: 24,01 °C

Art. No. 11148
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de 11148 V2.0 R1.0 Manual Page 3 of 4
9 Pin assignment
The 1-Wire Temperature Sensor Pro is supplied with screw terminals. The pin assignment is printed on
the printed circuit board.
In normal mode the sensor must be supplied with three cables, ground, 1-Wire Data and 5V.
In parasitic mode the sensor is only connected with ground and 1-Wire Data. Additionally, a connection
between 5V and ground must be established at the sensor.
Note: Basics and further information referring to the 1-Wire Bus system can be found in our eBook,
available for purchase in our webshop https://www.esera.de/service-support/dokumentation/.
10 Assembly
The location of the assembly must be protected against humidity. The device may be used only in dry
inside spaces and protected outside areas. Ensure that the installation is free of draughts. The device
is designed to be assembled as a fixed device within a switchboard.
11 1-Wire Network
No special requirements are needed on the cable used for short connection lengths. With unshielded cable, a
wider connection length can be achieved in an undisturbed environment, as the capacitive bus load is lower. A
total length of 60 m and more can be easily achieved with no additional measures.
In a disturbed environment, the cable should be shielded in order to improve the system’s sensitivity to
interference. The higher capacitive load reduces the maximum possible connection length.
The special thing about the wiring of the sensors is the “BUS technology”: All sensors are operated in parallel on
a three-core cable, which is used for both power supply and data communication.
12 Measuring accuracy
The sensors are calibrated during manufacture and have a typical measurement accuracy of ±0.5°
at 23°C operating temperature. The accuracy is reduced in addition to the upper and lower measuring
range limits. Further information can be found in the DS18B20 data sheet on our website.
13 Operating conditions
The sensor is designed to measure the temperature of gases. The Maxim temperature sensors are
semiconductor sensors. The unhoused sensors are designed for temperature measurements in the range of
-55 ... +125 °C. These temperature values stated under technical data are limit data for the entire
1-Wire Temperature Sensor Pro and must not be exceeded, otherwise the sensor may be damaged.
14 Disposal note
Do not dispose of the device in household waste! Electronic devices must be disposed of in
accordance with the directive on waste electrical and electronic equipment via the local
collection points for waste electronic equipment!
15 Safety instructions
When using products that come into contact with electrical voltage, the valid VDE regulations must be
observed, especially VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860
All final or wiring work must be carried out with the power turned off.
Before opening the device, always unplug or make sure that the unit is disconnected from the mains.
Components, modules or devices may only be put into service if they are mounted in a contact proof housing.
During installation they must not have power applied.
Tools may only be used on devices, components or assemblies when it is certain that the devices are disconnected
from the power supply and electrical charges stored in the components inside the device have been discharged.
Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults or
breaks.
If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty cable
has been replaced.

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de 11148 V2.0 R1.0 Manual Page 4 of 4
When using components or modules it is absolutely necessary to comply with the requirements set out in the
accompanying description specifications for electrical quantities.
If the available description is not clear to the non-commercial end-user what the applicable electrical characteristics
for a part or assembly are, how to connect an external circuit, which external components or additional devices can
be connected or which values these external components may have, a qualified electrician must be consulted.
It must be examined generally before the commissioning of a device, whether this device or module is basically
suitable for the application in which it is to be used.
In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary.
For operational and connection errors outside of our control, we assume no liability of any kind for any resulting
damage.
Kits should be returned without their housing when not functional with an exact error description and the
accompanying instructions. Without an error description it is not possible to repair. For time-consuming assembly or
disassembly of cases charges will be invoiced.
During installation and handling of components which later have mains potential on their parts, the relevant VDE
regulations must be observed.
Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified
electrician and put into operation.
Commissioning may only be realized if the circuit is built into a contact proof housing.
If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be
installed upstream or a suitable power supply can be used.
After installing the required tests according to DGUV / regulation 3 (German statutory accident insurance
https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance) must be carried out.
16 Warranty
ESERA GmbH guarantees that the goods sold at the time of transfer of risk to be free from material and workmanship
defects and have the contractually assured characteristics. The statutory warranty period of two years begins from date of
invoice. The warranty does not extend to the normal operational wear and normal wear and tear. Customer claims for
damages, for example, for non-performance, fault in contracting, breach of secondary contractual obligations,
consequential damages, damages resulting from unauthorized usage and other legal grounds are excluded. Excepting to
this, ESERA GmbH accepts liability for the absence of a guaranteed quality resulting from intent or gross negligence.
Claims made under the Product Liability Act are not affected.
If defects occur for which the ESERA GmbH is responsible, and in the case of replacement goods, the replacement is
faulty, the buyer has the right to have the original purchase price refunded or a reduction of the purchase price.
ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical
or electronic errors in the online offer.
We are constantly developing our products further and reserve the right to make changes and improvements to any of the
products described in this documentation without prior notice. Should you require documents or information on older
17 Trademarks
All mentioned designations, logos, names and trademarks (including those which are not explicitly marked) are
trademarks, registered trademarks or other copyright or trademarks or titles or legally protected designations of their
respective owners and are hereby expressly recognized as such by us. The mention of these designations, logos, names
and trademarks is made for identification purposes only and does not represent a claim of any kind on the part of ESERA
GmbH on these designations, logos, names and trademarks. Moreover, from their appearance on ESERA GmbH
webpages it cannot be concluded that designations, logos, names and trademarks are free of commercial property rights.
ESERA and Auto-E-Connect are registered trademarks of ESERA GmbH.
18 Contact
ESERA GmbH
Adelindastrasse 20
87600 Kaufbeuren
GERMANY
Tel.: +49 8341 999 80-0
Fax: +49 8341 999 80-10
www.esera.de
WEEE-Number: DE30249510