LEGRAND Tynetec ZXT426 User manual

DocNo.FM0460issueJPage1
169MHzTelecareDevices
TemperatureExtremeSensor
__________________________________________________________________________________________________________
CompatiblewithReachat‐homealarms,Adventxtwardencall,
AltecResponseandTouchsafeProNursecallsystems
Solidstatetemperaturesensingelement
Loweralarmtemperature:5oC+/‐2.5oCfor30/60minutes
Upperalarmtemperature:30oC+/‐2.5oCfor5/10minutes
Rateofrisealarmtemperature:8oCperminute
Userreplaceable3.6VAALithiumbattery
Lowbatterywarning
Testbutton
Dimensions:84x84x36mm(HxWxD)
Weight:102grams
ProductCode:ZXT426
WhatareTemperatureExtremeSensorsusedfor?
Thetemperatureextremesensorwillprovideearlywarningofextremeloworhighhouseholdtemperatureswhichcouldresultin
theoccupiersufferinghypothermiaordehydration.Inaddition,thebuildingwillalsobeprotectedagainstburstpipesorpotential
firehazards.
WhereshouldTemperatureExtremeSensorsbefitted?
Thetemperatureextremesensorshouldbefittedinthehallwayorlivingroom.
Itshouldbewallmountedataround1.4metresabovefloorlevelandawayfromanydraughtsorheatsources.
TypicalToolsRequired
Adrillandscrewdriverarenotrequirediftheselfadhesivepadisused.
Alwaysmakesurethecorrectdrillbitsandscrewdriversareused.
Installation–UsingScrewFixings
1. Removethetopbypullingapartfromthebacksection.
2. Drillthebacksectionasrequiredandfixtothewallusing
thescrews&plugsprovided.
3. SettheDILswitches&links,fitthebatteryandtestas
describedonthefollowingpagebeforerefittingthetopsection.
Installation–UsingSelfAdhesivePads
1.Removethetopbypullingapartfromthebacksection.
2. Selectthebestlocationwherethewallisclean,dryandeven.
3. Sticktheadhesivepadtotherearfaceofthebacksectionand
pressfirmlytothewallensuringitisstucksecurely.
4. SettheDILswitchesandlinks,fitthebatteryandtestas
describedonthefollowingpagebeforerefittingthetop.
PULLAPART
TOREMOVE
TOP
SECTION
FIXBACK
SECTIONTO
WALL
Tynetec andAidcallare businessunitsofLegrandElectricLtd
Unit10CowleyRoad,BlythRiversideBusinessPark,Blyth
Northumberland,NE245TF.Tel:01670352371Fax:01670362807
Email:[email protected]Web:www.tynetec.co.uk

DocNo.FM0460issueJPage2
DILSwitchSettings
SetDILswitch1ONforMode1;
LowTemperatureAlarm=lessthan5oC+/‐2.5oCfor30minutes
HighTemperatureAlarm=greaterthan30oC+/‐2.5oCfor5minutes
SetDILswitch1OFFforMode2;
LowTemperatureAlarm=lessthan5oC+/‐2.5oCfor60minutes
HighTemperatureAlarm=greaterthan30oC+/‐2.5oCfor10minutes
SetDILswitch2OFFfor169MHztransmitterfrequency
LinkSettings
LK1–notused
SetLK2&LK3bothinposition“B”
FittingtheBattery
Onlyusethe3.7VAALithiumbatterysupplied.
Takecaretoensurethebatteryisfittedcorrectly,fitwiththered“+”endtotherighthandsideasshownabove.
Testing&RegisteringtheTemperatureExtremeSensor
TheTESTbuttonmustbepressedwhenlearningthetemperatureextreme
sensorontothewardencallsystem,at‐homealarmorNursecallsystem.
Seethefollowingpagesforhowtoputeachofthese
productsinto“LearnMode”.
PressandholdtheTESTbuttonforabout3secondsuntil
theREDlightstartstoflash.
After9flashestherewillbea10secondpausefollowedby
another9flashes(thesensortransmitsahightemperature
signalfollowedbyalowtemperaturesignal).
RemovethebatterytoEXITTESTMODE
LeaveforafewsecondsthenrefitforNORMALOPERATION.
Therangeofallradiodevicescanbeaffectedbytheworkingenvironment‐alwaystakecareduringinstallationand
performseveraltestcalls.
Cleaning&Care
Temperatureextremesensorsshouldbecleanedperiodically.
Usethenozzleattachmentonavacuumcleanertoremovedust,insectsandcobwebsfromthecoverslots.
Thecasecanbewipedcleanwithadampcloth,neverusedetergentsorpolishetc.
Decorating
Neverpaintthetemperatureextremesensoritself.
Itisnotsusceptibletocontaminationfrompaintfumesthereforeno
specialprecautionsneedtobetaken.
BatteryLife
Thetemperatureextremesensorbatteryischeckedonceaday,ifthevoltagefallsandstaysbelowapresetlevelfor7consecutive
daysalowbatteryalertisautomaticallytransmitted.Oncealowbatterycallisreceivedthebatteryshouldbereplacedwithin7
days.DetailedinformationonbatterymanagementforallTynetec/Aidcallproductsisavailable‐requestDocNo.FM0630.
LINK
SETTINGS
DIL
SWITCH
SETTINGS
FITBATTERYASSHOWN
REDLIGHT
TESTBUTTON

DocNo.FM0460issueJPage3
RegisteringaTemperatureExtremeSensorontoaReachat‐homealarmunit
1.PuttheReachunitintoradiodevicelearnmode…
2.Activatethetemperatureextremesensor…
3.Exitradiodevicelearnmode…
4.CheckwiththeControlCentrethatitisconvenienttoperformatestcall,presstheTESTbuttonandconfirmtheyreceiveahigh
temperaturealarmcallfollowedbyalowtemperaturealarmcall.Remembertoremoveandrefitthebatteryafterthetestcall.
DeletingaTemperatureExtremeSensorfromaReachat‐homealarmunit
Enter1670usingthekeypadontherearoftheReachunit–thefrontlightwillFLASHFASTGREENandtheunitwillannounce
“ProgramMode‐Ready”.
Enter#041andtheReachwillannounce“DeleteRadioDevice”followedbya“Beep”.
Enter41(hightemperature)followedbythe6digitsensorIDtobedeletedandwaitforthe“Beep”
Enter42(lowtemperature)followedbythe6digitsensorIDtobedeleted,afterthe“Beep”press#toexit.
PressthekeytoexitProgramMode;theunitwillsounda“Double‐Beep”andthefrontlightwillreturntoSTEADYGREEN.
The6digitIDcanbefoundonalabelonthebackofthetemperatureextremesensor.
TheinstructionsgivenaboveforthestandardReachproductalsoappliestotheReachPlus,ReachPlusGSM
andReachUltramodels.Refertotheinstructionbookletsprovidedwiththeseproductsformoreinformation
onprogrammingandtestingradiodevices.
“Trigger
Radio
Device”
PressandHOLDtheGREENbuttonontheReachunit.
WhenthefrontlightFLASHESFASTGREENreleasethe
buttonandtheReachwillannounce“TriggerRadioDevice”.
Younowhave1minutetoactivatethetemperatureextreme
sensor.
PresstheGREENbuttonontheReachunit.
ThefrontlightwillreturntoSTEADYGREENandtheReach
isbackinnormaloperatingmode.
PressandholdtheTESTbuttonforabout3secondsuntilthe
REDlightstartstoflashandtheReachwillannounce
“HighTemperature”.
WhentheREDlightstopsflashingwaitforabout10seconds
anditwillstartflashingagainandtheReachwillannounce
“LowTemperature”.
IMPORTANT:removethebatterytoEXITTESTMODE,leave
forafewsecondsthenrefit.

DocNo.FM0460issueJPage4
RegisteringaTemperatureExtremeSensorontoanAdventxtwardencallsystem
1.PuttheAdventxtsystemintoradiodevicelearnmode…
2.Activatethetemperatureextremesensor…
3.ExittheAdventxtsystemradiodevicelearnmode…
4.PresstheTESTbuttonandcheckahightemperaturealarmcallisreportedonthewardencallsystemfollowedbyalow
temperaturealarmcallabout20secondslater.Remembertoremoveandrefitthebatteryafterthetestcall.
DeletingaTemperatureExtremeSensorfromanAdventxtwardencallsystem
PresstheLINEkeyandwaitforthe“Ready”prompt.
Enter5001followedbythekey.
Entertheflatnumberthetemperatureextremesensorisbeingdeletedfromfollowedbythekey.
PressTESTbuttononthetemperatureextremesensortobedeleted.
Waitforthe“PendantDisabled–EnterFlat”prompt.
Waitforabout20secondsforthesecond“PendantDisabled–EnterFlat”prompt.
Pressthe#keyandwaitforthe“Ready”prompt,thenpresstheLINEkeytocleartheconnection.
RefertotheAdventxtoperatorsmanual(DocNo.FM0420)providedwiththewardencallsystemformore
informationonprogrammingandtestingradiodevices.
UsingtheManager’sDECTtelephone;
PresstheLINEkeyandwaitforthe“Ready”prompt.
Enter5000followedbythekey.
Entertheflatnumberthetemperatureextremesensorisbeinginstalled
infollowedbythekey.
Younowhave1minutetoactivatethetemperatureextremesensor.
“Ready”
UsingtheManager’sDECTtelephone;
Pressthe#keyandwaitforthe“Ready”prompt.
PresstheLINEkeytocleartheconnectionandthewardencallsystemis
nowbackinnormaloperatingmode.
PressandholdtheTESTbuttonforabout3secondsuntiltheRED
lightstartstoflash.
Waitforthe“EnterLocationCode”promptthenpress0
(nolocation)followedbythekey.
Waitforthe“PendantEnabled–EnterFlat”prompt.
Afterabout20secondsyouwillhearthe“EnterLocationCode”
promptagain‐press0(nolocation)followedbythekey.
Waitforthe“PendantEnabled–EnterFlat”prompt.
IMPORTANT:removethebatterytoEXITTESTMODE,leavefora
fewsecondsthenrefit.
“Ready”

DocNo.FM0460issueJPage5
RegisteringaTemperatureExtremeSensorontoanAltecResponselocalcareralarmunit
1.PuttheAltecResponseunitintoradiodevicelearnmode…
2.Activatethetemperatureextremesensor…
3.ExittheAltecResponseradiodevicelearnmode…
4.PresstheTESTbuttonandcheckahightemperaturealarmcallisreportedontheAltecResponseunitfollowedbyalow
temperaturealarmcallabout20secondslater.Remembertoremoveandrefitthebatteryafterthetestcall.
DeletingaTemperatureExtremeSensorfromanAltecResponselocalcareralarmunit
PressENTERtoactivatethewake‐updisplaythenENTERagaintodisplaythemainmenu
PressENTERtoselectRadioDevices
PressthekeytoselectDeleteDevicethenpressENTER
Thedisplaywillpromptyouto“TriggertheSensor”
PresstheTESTbuttononthetemperatureextremesensortobedeleted‐thedisplaywillshowhightempandits41xxxxxxID
IfthisisthedeviceyouactivatedpressthekeytoselectDeletethenpressENTER
Afterabout20secondsthedisplaywillshowthelowtempandits42xxxxxxID
IfthisisthedeviceyouactivatedpressthekeytoselectDeletethenpressENTER
Note:iftheIDisNOTthedeviceyouactivatedpresstheENTERkeytoselectRejectthentryagain
ToexitthemodeselectExitthenpresstheENTERkey.
RefertotheAltecResponseinstallationguide(DocNo.FM0548)providedwiththeportablealarmunitfor
moreinformationonprogrammingandtestingradiodevices.
PressandholdtheTESTbuttonforabout3secondsuntiltheREDlightstartstoflash.
ThedisplaywillshowHighTemperatureandits41xxxxxIDnumber.
ChecktheIDiscorrect,pressthekeytoselectAcceptthenpressENTER.
Note:ifanotherdevicehasbeenpicked‐uppressENTERtoRejectandtryagain.
ThedisplaywillshowFlat,usethe&keystochoosethedwellingtype.
PressthekeytoselectNo:000000thenpresstheENTERkey.
Usethe&keystoselecteachdigitoftheflatnumberandthe
&keystomovebetweendigitsthenpresstheENTERkey.
PresskeyseveraltimestoselectExitthenpresstheENTERkey.
Thedisplaywillpromptyouto“TriggertheSensor”again.
Afterabout20secondsthedisplaywillshowLowTemperatureandits42xxxxxID
number,repeatasabove.
IMPORTANT:removethebatterytoEXITTESTMODE,leaveforafewsecondsthenrefit.
PressENTERtoactivatethewake‐updisplaythenENTERagaintodisplay
themainmenu.
PressENTERtoselectRadioDevices
PressENTERtoselectLearnDevice
Thedisplaywillpromptyouto“TriggertheSensor”.
Younowhave20secondstoactivatethetemperatureextremesensor.
FromtheLearnDevicemenuselectExitthenpressENTER.
FromtheRadioDevicesmenuselectExitthenpressENTER.
Thedisplaywillreturntothewake‐upscreenandgoblankafter10seconds.
TheAltecResponseisnowbackinnormaloperatingmode.
tynetec
tynetec

DocNo.FM0460issueJPage6
RegisteringaTemperatureExtremeSensorontoaTouchsafeProNursecallsystem
1.PuttheTouchsafeProMasterPanelintoTelecareregistrationmode;touchthescreenandLogonasanEngineeroraManager
(passwordrequired),thenfromthemainmenupagetouchtheTelecarebuttontoopenthescreenshownbelow…
2.Enterthetemperatureextremesensor8digitID’s…
3.PresstheClosebuttontoexitTelecaremodeandtheNursecallpanelisnowbackinnormaloperatingmode.
4.PresstheTESTbuttonandcheckahightemperaturealarmcallisdisplayedontheNursecallpanellikebelowfollowedbyalow
temperaturealarmcallabout20secondslater.Remembertoremoveandrefitthebatteryafterthetestcall.
Thescreenbannerisredforhigh/lowtempalarmcalls(Touchthebannertodisplaynotes).
Ahighorlowtemperaturealarmcallcannotbeacceptedorsilencedfromthescreen.
YoumustvisittheappropriateNursecallCallPointtocancelthecall.
DeletingaTemperatureExtremeSensorfromaTouchsafeProNursecallsystem
SelectthehightemperaturesensorIDtobedeletedfromtheDeleteTelecareDevicepull‐downlistbox(prefixed“T41”).
DetailsofthesensorselectedwillbedisplayedintheRoom,HouseCodeandIDboxesbelow.
IfthedetailsshownarecorrectpresstheDeletebutton.
SelectthelowtemperaturesensorIDtobedeletedfromtheDeleteTelecareDevicepull‐downlistbox(prefixed“T42”)
RepeatasaboveandpresstheClosebuttontoexit.
RefertotheTouchsafeProDisplayPaneluserguide(DocNo.FM5505)providedwiththeNursecallsystemfor
moreinformation.
TynetecandAidcalloperateapolicyofcontinuousimprovementandreservetherighttochangeproductspecificationswithoutnotice.
IfanyvariationtothedetailscontainedinthisdocumentaresuspectedpleasecontactTynetec’scustomersupportdepton01670352371.
The8digitID’saremadeupofthe2digitdevicetypecode(HighTemp=41&LowTemp=42)
followedbythe6digitunitIDwhichcanbefoundonalabelonthebackofthesensor.
TouchtheAddTelecareDeviceboxthenusetheon‐screenkeypadtoenterthehightempID.
Hint:enterazoneintheFilterboxtonarrowthesearchfortheroom(seebelow).
SelecttheusersCallPointIDfromtheRoompull‐downlistboxthenpressSave.
Note:thisistheroomunitthatwillbewillbeusedtocancelthecall.
TouchtheAddTelecareDeviceboxagainandrepeatasabovebutthistimeenterthelow
tempIDi.e.42followedbythesame6digitIDfromthelabel.
Usekeypadtoenter
8digitID’s*here
Selecttherelevant
CallPointIDhere
Savewhendone
Closetoexitmode
On‐screenkeypad
CALLING
CANCEL
HC345ID001
PresstheLIGHTGREY
buttontocancelthecall
*Note:bothhighandlow
temperatureID’smust
beentered;
Prefix41=HighTemp
andPrefix42=LowTemp
ZXT426W66265
Ser:10151997
ID:037233
EE1770V1.05A
DR
Other LEGRAND Temperature Controllers manuals