eSSL inBIO460 Series User manual

Security at Fingertips
www.esslsecurity.com
Installation Manual
inBIO460 Installation Guide v1.3

1
Box Lock Hole
State Indicator
Thread Hole
Backup Battery Control Panel
Air Switch
Panel Box Appearance Panel Box Inside Get the Panel o the track
Heat
2.Components
Power Supply
Temper Switch
Dissipation Hole
Control Panel
Panel Track
2
1
inB I O 46 0 I nstallation and C onnection G uide
Version: 1.3 Date: Jan. 2014
1.Cautions
Please note th e follo win g cautio ns. Mis -opera tio n may lead to pers onal in jury or
equip ment failu re:
1)Do not energize the syste m before in stalla tio n is comple te; never carr y out
insta lla tio n activ itie s when th e syste m is energized.
2)All perip heral devic es must be gro unded.
3)The conduits of wire s under re lay must be matc hed with meta le d conduits , oth er wire s
can use PVC conduits.
4)It is stro ngly recommended th at the length of exposed part of any connectio n cable
should not be longer than 4 mm. Professio nal clamping tools may be used to avoid
unintentio nal conta ct of exposed wire s to avoid short- circ uit or communic atio n fa ilu re.
5)It is re commended th at card readers and butto ns be insta lle d at height of 1.4 m-1 .5m
above ground.
6)It is re commended to use th e power supply fo r contro l panel, and exte rnal power
supply for each lo ck.
7)The applia nce shall be insta lle d and wire d in accord ance with natio nal electric al
code and by qualifie d pers onnel only.
Descr ip tio n of nor mal wor k ing sta te:
Connect th e system to th e power supply. If th e syste m work s properly , the POWER
indic ato r (red) is lit consta ntly and th e RUN indic ato r (green) fla shes.
V alve r egulated lea d-ac id ba ttery :
Constan t voltage charge volt age reg ulati on
Cycle use : 14.5V ~14.9V (25 )
Initial cu rren t: less tha n 2.88 A
Stan dby use: 13.6V ~13.8V (25 )
Capacit y: 12V, 7.2A h/20 hr,
Battery Type: LC-RA127R2T1
C aution :
Do not charge in a gas tight containe r.
Do not short the battery term ina ls.
Do not inc ine rate
Flush wit h water at once if contact is made wit h
elec trolyte (Acid )
Do not attem pt to disasse mble the battery .

2
3.Installation
Thread holes
Screws
4.LED Indicators and Wire Illustration
After the following installation, fix the panel to the track first, and then install other components to original
Control Panel
Panel Track
2
1
3) Install other components
2) Fix the box
1) Get through the thread hole
positions.
1) Meaning of LED indicators:
LINK indicator (green): Constant light indicates TCP/IP communication is normal;
ACT indicator (yellow): Flashing indicates data is in transmitting through TCP/IP communication.
EXT RS485 indicator (yellow&green): Flashing indicates it is sending or receiving data through RS485 communication.
PC RS485 indicator (yellow&green): Flashing indicates it is sending or receiving data through RS485 communication.
POWER indicator (red): Light always indicates the control panel is power on.
RUN indicator (green): Flashing indicates that system works normally.
CARD indicator (yellow): Flashing indicates a card is punched on reader.
2) Recommended use of wires:
3) The auxiliary input may be connected to infrared body detectors, alarm switches, etc.
4 The auxiliary output may be connected to door bells, alarms, etc.)
5) State Indicators are connected to the panel box, with is power indicator, run status indicator and communication status indicator.
Interf ace W ire Sp ecicati on Networ k cable M aximum length
Power (A) 18AWG*2PIN / 1.5M
Wiegand (B)
24AWG*6PIN
(6PIN, 8PIN, 10PIN for different
readers)
CAT-5 or a bove network cable, one
way DC impedance is less tha n 100Ω
/KM
100M
Electric L ock (C)
18AWG*2PIN+24AWG*2PIN,
18AWG*2PIN for lock connection,
24AWG*2PIN for door sensor
connection.
/ 50M
Button (D) 24AWG*2PIN / 100M
EXT485 (E)
20AWG*2PIN+24AWG*2PIN,
20AWG*2PIN for reader powe r
supply, 24AWG*2PIN for RS485
communication
CAT-5 or a bove network cable, one
way DC impedance is less tha n 100Ω
/KM. In wire connection, +12V a nd
GND of power supply need to be
parallel and use double wires.
Share power with control panel: 100M
Use independ ence powe r supply
(connect RS485 signal interface o nly):
1000M

3
STATE
PWR
EXT
RS485
P C
RS4 85
SWIT CH
D
AUX Input 1
D
AUX Input 2
D
AUX Input 3
D
AUX Input 4
E
RS485
Reader
State Indicator
D
Exit Button for
Lock1
B
Reader for
Lock1
D
Exit Button for
Lock2
B
Reader for
Lock2
D
Exit Button for
Lock3
B
Reader for
Lock3
D
Exit Button for
Lock4
B
Reader for
Lock4
Power Input
A
ALock Power Input
LINK
PC Network
Interface
ACT
DIP Switch
RS485
Converter
PC
DAUX Output 1
DAUX Output 2
DAUX Output 3
DAUX Output 4
CLock 1
CLock 2
CLock 3
CLock 4
SD Card Interface.
F un ction:
Backup Access
Control Logs
AUX Input (1-4) connect to the infrared human
body induction, wireless exit button, windows
sensor with dry contact (no voltage).
AUX Input (1-4) connect way is same.
N ote:
Output Electrical Parameters:
Rated Voltage: 12V(DC)
Rated Current: 0.5A
5
1
AUX Output (1-4) connect to alarm, door bell and so on;
Port (NO, COM, NC) Electrical Parameters:
MAX Voltage: 36V(DC) MAX Current: 1.25A
N ote:
AUX Output (1-4) connect way is same.
L ock ( 1-4) :
Port (SEN)connect to door sensor single with
dry contact (no voltage);
Port (NO, COM, NC) Electrical Parameters:
MAX Voltage: 36V(DC) MAX Current: 2A
N ote:
When you select Wet mode, the power is Lock power,
Lock (1-4) total load don’t more than Lock power Rated
current (2A).
Lock (1-4) connect way is same.
2
Lock Power Input Electrical Parameters:
Rated Voltage: 36V(DC) Rated Current: 2A
Device Power Input Electrical Parameters:
Rated Voltage: 12V(DC) Rated Current: 2A
34
Exit button for Lock (1-4) connect to Exit button with dry contact.(no voltage);
Reader (1-4) connect to WG Reader;
Port (+12V)Output Electrical Parameters:
Rated Voltage: 12V(DC) Rated Current: 0.5A
Port (BEEPGLED) Output Electrical Parameters:
Rated Voltage: 5V(DC) Raged Current: 0.5mA
7
6
5
1
2
3
4
7
6
1
1
1
2
2
2
5
5
5
6
6
6
7
7
7

4
6.Lock Connection
5.DIP Switch Settings
1) 1-6 are used to set the number in communication:Switches control panel RS485 It is adopted binary coding and
address number should not be repeated in the network.
2) Number 7 switch is used to restore factory defaults: Switch it for three times within 10 seconds and restart the
3) Number 8 switch is used to set terminal resistance in RS485 communication: Switch it to“ON” status, For adding a
4) When electrical lock is connected with access control system, you need to parallel a FR107 diode (equipped in
1) The control panel provides lock control output interfaces. For NO lock, it is normal open when power is on, so
2) The control panel supports “dry mode” and “wet mode” by using the jumper. For “wet mode”, short 2-3 and
little endian, the address number setting by placing these 6 switches as shown in the figure below. Before setting
F or ex ample: Set the device number as 39 (39=1+2+4+32), the switches status are 111001, that is set number 1, 2,
COM and NO terminals should be used. For NC lock, it is normal closed when power is on, so COM and NC
in the package) to prevent the self-inductance EMF affecting the system, do not reverse the polarities.
terminal resistance of 120 ohm between 485+ and 485-.
device then all data will be cleared and the system restored factory default setting.
the address , please keep the system powered off. Place the corresponding switches to the desired status, and the
3 and 6 switches at “ON”.
terminals should be used.
4-5 terminals. The control panel and the lock use separate power supplies: One is connected with +12V and
GND of POWER interface (for the control panel), the other is connected with V+ and V- of LOCK interface
(for the lock). For detailed settings for “dry mode” and “wet mode” , please refer to the Installation Guide.
The factory default is dry mode.
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
1
2
4
8
16
32
Restore Fact ory Set tings
RS485 Terminal Resistance
1 2 3 4
O
5 6 7 8
N
3) he standardFor the Wiegand reader and the inBIO reader, t power supply is 12V/3A. So we do not recommend
that the control panel If it is necessary to do so we suggest using alock and share a common power supply.
larger one such as 12V/5A.Not including the power reserve, there are 2Acurrent for the lock. For the common
electrical lock (the standby current is 300mA, the max current is 500mA), the maximum connected lock is 4.

5
The following is “wet mode” lock connection with external power supply .
Stick the screw driver to the rectangular hole on the four corner of the panel back, push it from outside to inside.
After hearing the "click"sound,you can remove the case from the panel.
7.485 Reader (inBIO Reader) Connection
+
+
+
-
-
NC
NO
GND
COM
SEN
+
+
-
-
FR107
-
LED
1
2
3
4
5
NO Lock
LOCK
LOCK
Enla rg ed d ia gr am
of loc k te rm in al s
NC Lock
Lock Power
Diode
Diode
Jumper
terminal
FR107
+12V
GND
#3 Reader
+12V
GND
485-
GND
485+
#1 Reader #2 Reader #8 Reader
...
(Separate power supplies) (Separate power supplies)
PC
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
5
The control panel supports inBIO biometric verification reader and Wiegand reader. All inBIO reader operations are executed
For reader 1, 2 (the odd number is for entered reader, and the even number is for exit reader), the door number is 1. And the
485 address is 1, 2, as in the figure below. For more information, please refer to the software user manual.
from the control panel including storage, verification, etc. Re-register the fingerprints is not required when replacing the reader.
For example, use the FR1200 reader , the standby current is less than 100mA, the max current is less than 120mA, When
using the separately power supplies, to make sure the steady operation.
Besides, a single EXT485 interface can supply maximum 500mA(12V) current.Sothe entire cuttent consumption
should be less than this max value when the readers share power with the panel.
In calculation, more than twice of theplease use max current of the reader, and start current is usually
normal work current, please consider of this situation.
inBIO r eader connection: First of all, set the 485 address (device number) of the reader by DIP switch and software.
Attention: DIP switch configuration for FR1200, KR500E&M-RS; Software configuration for unnormalized F11,MA300 and other fingerprint readers.
the device is start, Instantaneous current can reach 240 mA. As inBIO reader, consider the starting current is
bigger,onnectthrough the EXT485 interface can only c two readers for power supply.So the power of control
panel connect only For some of the devices with much greater consumption, we suggest tonearest 2 readers.

6
8.Equipment Communication
1. TCP/IP Communication
2. RS485 Communication
The PC software can communicate with the panel according to the communication protocols (RS485 and TCP/IP) for data
exchange and remote management. The communication cable should be as far away from high-voltage lines as possible.
Do not keep the communication cable in parallel with power cords or bind them together.
1) Internationally accepted RVVP (shielded twisted-pair) wires should be used for communication to effectively avoid
of bus cascade connection.interference. RS485 communication wires should be connected by means
PC
485+
485-
G N D
485+ 485+ 485+
485- 485- 485-
G N D G N D G N D
serial line
4 8 5
Converter
DI P Swi t ch
8# C o ntr ol Pan el
2# C ontr ol Pan el
1# Control Panel
1 2 3 4
O
5 6 7 8
N
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
1# Control Panel 2# Control Panel
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
PC
Switch
n8 C o ntro l P anel
STATE
PWR
EXT
RS485
PC
RS485
SWITCH
3) One RS485 bus may hold 63 control panels, but it is recommended to connect with less than 32 .access control panels
4) For the inBIO reader connection, if the reader and the control panel use the same power, it is recommended that the wire
5) To enhance the stability of communication t is necessary to keepWhen the wire is longer than 300 meters, i
2) It is recommended that the RS485 bus should be less than 600 meters to aid communication stability.
(120 ohm) of the two devices to the system. As shown in the figure above, turn number 8 of the DIP switches of
number 8 switch of the first and the last control panel at “ON” status. That adds the RS485 terminal resistance
should be less than 100 meters. If greater length is required, please use a separate power supply.
the 1#and 8# at “ON” status.

#24,Shambavi Building, 23rd Main,Marenahalli,
JP Nagar 2nd Phase, Bangalore - 560078
www.esslsecurity.com
Other manuals for inBIO460 Series
1
Table of contents
Popular Controllers manuals by other brands

Rockwell Automation
Rockwell Automation PowerFlex 700S Migration guide

Danfoss
Danfoss VLT HVAC Drive FC 102 Design guide

Carel
Carel pCO1 series Application program

Allen-Bradley
Allen-Bradley PowerFlex 7000 user manual

Tech Controllers
Tech Controllers EU-i-2 user manual

National Instruments
National Instruments sbRIO-9637 Getting started guide

Danfoss
Danfoss EKC 302A instructions

HWH
HWH 725 SERIES Operator's manual

hager
hager coviva Smartbox TKP100A quick guide

Netafim
Netafim NLC-100SH Installation & troubleshooting manual

Becker
Becker Centronic SunWindControl SWC510 Assembly and operating instructions

Helios
Helios ESE 2,5 Mounting & operating instructions