ETS-Lindgren EMCenter User manual

EMCenter™
Modular RF Platform
User Manual

ii www.ets-lindgren.com
ETS-Lindgren Inc. reserves the right to make changes to any product described
herein in order to improve function, design, or for any other reason. Nothing
contained herein shall constitute ETS-Lindgren Inc. assuming any liability
whatsoever arising out of the application or use of any product or circuit
described herein. ETS-Lindgren Inc. does not convey any license under its
patent rights or the rights of others.
© Copyright 2013–2016 by ETS-Lindgren Inc. All Rights Reserved. No part
of this document may be copied by any means without written permission
from ETS-Lindgren Inc.
Trademarks used in this document: The ETS-Lindgren logo is a registered
trademark, and EMCenter, EMSwitch, EMPower, EMControl, EMSense, EMLink,
TILE!, and EMQuest are trademarks of ETS-Lindgren Inc.
Revision Record | MANUAL, EMCenter | Part #399342, Rev. C
Revision Description Date
A Initial Release July, 2013
B Updated EMCenter models June, 2014
C Updated USB Driver installation
instructions
November, 2016

www.ets-lindgren.com iii
Table of Contents
Notes, Cautions, and Warnings ............................................... vi
1.0 Introduction .......................................................................... 7
EMCenter Plug-In Cards (Optional) ............................................................................... 8
EMSwitch RF Switch Plug-In Card ........................................................ 8
EMPower Plug-In Card and EMPower Sensors .................................... 9
EMControl Positioner Control Plug-In Card ......................................... 10
EMSense EMF Probe Plug-In Card ..................................................... 10
EMGen RF Signal Generator Plug-In Card ......................................... 11
Standard Configuration ................................................................................................ 11
ETS-Lindgren Product Information Bulletin .................................................................. 12
2.0 Maintenance ....................................................................... 13
Maintenance of Fiber Optics ........................................................................................ 14
Service Procedures ...................................................................................................... 14
3.0 Specifications ..................................................................... 15
Performance Specifications ......................................................................................... 15
Physical Specifications ................................................................................................ 15
Environmental Specifications ....................................................................................... 15
Power Specifications .................................................................................................... 16
Interface and Cable Specifications .............................................................................. 16
4.0 Laser Safety ........................................................................ 17
Safety Precautions ....................................................................................................... 17
Safety Features ............................................................................................................ 18
5.0 EMCenter Controls and Connectors ................................ 19
Front Panel .................................................................................................................. 1 9

iv www.ets-lindgren.com
Status Indicators .................................................................................. 19
Back Panel ................................................................................................................... 2 0
6.0 Installation .......................................................................... 23
Plug-In Card Installation ............................................................................................... 23
7.0 Manual Control of the EMCenter ...................................... 25
Common Control Buttons ............................................................................................. 25
Powering On and Off ................................................................................................... 26
Power On ............................................................................................. 26
Power Off ............................................................................................. 27
Information Screen ....................................................................................................... 28
Home Screen ............................................................................................................... 29
Card Slot Numbers .............................................................................. 29
Status Box ........................................................................................... 30
Control Buttons .................................................................................... 30
Local Mode .......................................................................................... 30
Configuration Screen ................................................................................................... 31
8.0 Remote Control of the EMCenter ..................................... 33
First Character: Identifier ............................................................................................. 33
Second Character: Device ID Number ......................................................................... 34
Command Examples .................................................................................................... 35
Example 1: Request Device Identification ........................................... 35
Example 2: Request an E-Field Reading ............................................ 35
Example 3: Request a Power Value .................................................... 35
Command Set and Error Codes ................................................................................... 36
Command Set ...................................................................................... 36
Error Codes ......................................................................................... 36
Using the USB Interface .............................................................................................. 37

www.ets-lindgren.com v
Download USB Drivers ........................................................................ 38
If Your Computer is Installed with Windows 7, 8, or 10 ....................... 38
To Change the COM Port Assignment ................................................ 39
Appendix A: Warranty ............................................................. 41
Appendix B: EC Declaration of Conformity .......................... 43

vi www.ets-lindgren.com
Notes, Cautions, and Warnings
Note: Denotes helpful information intended to
provide tips for better use of the product.
Caution: Denotes a hazard. Failure to follow
instructions could result in minor personal injury
and/or property damage. Included text gives proper
procedures.
Warning: Denotes a hazard. Failure to follow
instructions could result in SEVERE personal injury
and/or property damage. Included text gives proper
procedures.
See Laser Safety on page 17 for detailed laser safety precautions and
operational features.
See the ETS-Lindgren Product Information Bulletin for safety,
regulatory, and other product marking information.

www.ets-lindgren.com Introduction 7
1.0 Introduction
For flexible configuration of an EMC test facility and fully-automated testing, the
ETS-Lindgren EMCenter™ Modular RF Platform provides space for up to
seven plug-in cards in a 3U, 19-inch rack mount enclosure. The EMCenter can
also be used as a desktop unit.
The EMCenter is available in the following configurations:
Model 7000-001: 7-slot EMCenter Modular RF Platform
Model 7000-010: 7-slot EMCenter Modular RF Platform with GPIB
Model 7000-011: 2-slot EMCenter Modular RF Platform with GPIB
The slots can contain a user-defined combination of these ETS-Lindgren cards:
EMSwitch™, EMPower™, EMControl™, and EMSense™. When installed, each
card is automatically recognized, initialized, and ready for use. For more
information on the cards, see EMCenter Plug-In Cards (Optional) on page 8.
The EMCenter is configured and controlled using the 7-in widescreen color
thin-film transistor (TFT) touchscreen on the front panel. Additionally, the
EMCenter may be controlled from a computer using these software products:
ETS-Lindgren TILE!™ (Totally Integrated Laboratory Environment)
ETS-Lindgren EMQuest™ Data Acquisition and Analysis Software
Other test automation software

8Introduction www.ets-lindgren.com
The EMCenter contains a Vortex-embedded main processor to control all cards
and to interface with the user and/or an external computer. The operating system
is Linux-based, providing a stable operating environment, fast startup time, and
high performance. All embedded software is stored in flash, making it easy to
upgrade to new versions and future functionality.
EMCenter Plug-In Cards (Optional)
EMS
WITCH
RF S
WITCH
P
LUG
-I
N
C
ARD
EMSwitch is a general purpose multi-channel switch matrix used to switch the RF
path of equipment for RF measurement applications, including immunity,
emissions, and wireless measurements. EMSwitch is available with two SPDT
coaxial relays, four SPDT coaxial relays, or two SP6T coaxial relays; a 40 GHz
option is also available. EMSwitch cards switch RF signals from DC–18 GHz,
with powers up to 240 W.
Model 7001-001 Model 7001-003 Model 7001-002
(not all models shown)

www.ets-lindgren.com Introduction 9
EMP
OWER
P
LUG
-I
N
C
ARD AND
EMP
OWER
S
ENSORS
The EMPower Meter Plug-in Card occupies one slot in the EMCenter and
includes four USB ports, accommodating any combination of up to four EMPower
USB RF Power Sensors.
Two versions of the EMPower sensors are available:
Model 7002-002 and Model 7002-004: Support RMS measurements
for CW signals.
Model 7002-003 and Model 7002-005: Measure RF bursts as short as
a few microseconds.
The 7002-002 and 7002-003 sensors cover the 9 kHz to 6 GHz range, and the
7002-004 and 7002-005 sensors cover the 80 MHz to 18 GHz.

10 Introduction www.ets-lindgren.com
EMC
ONTROL
P
OSITIONER
C
ONTROL
P
LUG
-I
N
C
ARD
EMControl is a versatile positioner controller
which enables you to synchronize the
simultaneous movements of up to two
ETS-Lindgren positioning devices
(for example, towers or turntables) and the
on/off operation of an additional auxiliary
device, such as a LISN or EUT.
EMS
ENSE
EMF P
ROBE
P
LUG
-I
N
C
ARD
The EMSense card provides an interface for
ETS-Lindgren battery-powered EMC field
probes. Each EMSense card can support
one probe.

www.ets-lindgren.com Introduction 11
EMG
EN
RF
S
IGNAL
G
ENERATOR
P
LUG
-I
N
C
ARD
The EMGen card is a modular signal
generator with AM and pulse modulation,
covering a frequency range of
9 kHz to 6 GHz. EMGen is designed for
EMC testing, and quickly and accurately
performs EMC tests without the need for
an external modulation source.
Standard Configuration
Standard configuration may vary by EMCenter model; contact
ETS-Lindgren for additional information.
EMCenter Modular RF Platform
Cables: RS-232, USB, power
Interlock plug
Mains lead
19-inch mounting brackets

12 Introduction www.ets-lindgren.com
ETS-Lindgren Product Information Bulletin
See the ETS-Lindgren Product Information Bulletin included with your shipment
for the following:
Warranty information
Safety, regulatory, and other product marking information
Steps to receive your shipment
Steps to return a component for service
ETS-Lindgren calibration service
ETS-Lindgren contact information

www.ets-lindgren.com Maintenance 13
2.0 Maintenance
Before performing any maintenance,
follow the safety information in the
ETS-Lindgren Product Information
Bulletin included with your shipment.
Maintenance of the EMCenter is limited to
external components such as cables or
connectors.
Clean the exterior of the cabinet using a
damp cloth and mild cleaner. Always
unplug the unit before cleaning.
To prevent electrical shock, do not
remove cover.
Warranty may be void if the housing is
opened.
If you have any questions concerning
maintenance, contact ETS-Lindgren
Customer Service.
WARRANTY

14 Maintenance www.ets-lindgren.com
Maintenance of Fiber Optics
Fiber optic connectors and cables can be damaged from airborne particles,
humidity and moisture, oils from the human body, and debris from the connectors
they plug into. Always handle connectors and cables with care, using the
following guidelines.
Before performing any maintenance, disconnect
the fiber optic cables from the unit and turn off
power.
When disconnecting fiber optic cables, apply the
included dust caps to the ends to maintain their
integrity.
Before connecting fiber optic cables, clean the
connector tips and in-line connectors.
Before attaching in-line connectors, clean them
with moisture-free compressed air.
Failure to perform these tasks may result in
damage to the fiber optic connectors or cables.
Service Procedures
For the steps to return a system or system component to ETS-Lindgren for
service, see the Product Information Bulletin included with your shipment.

www.ets-lindgren.com Specifications 15
3.0 Specifications
Performance Specifications
Slots: 2 to 7 modular card slots
(depends on model)
Display: TFT with touchscreen
7.0-in WVGA (800 x 480)
Processor: 800 MHz Vortex 860x CPU
Memory: 256 MB DDR2 RAM, 512 MB Flash
Operating System: Linux
Configuration: Desktop or 19-in rack mountable
Physical Specifications
Height: 3U: 132 mm (5.2 in)
Width: 447 mm (17.6 in)
Depth: 350 mm (13.8 in)
Controller Weight (approximate): 7 kg (15.4 lb)
Environmental Specifications
Temperature Range: 0°C to 40°C (32°F to 104°F)
Relative Humidity: 10% to 90% (non-condensing)

16 Specifications www.ets-lindgren.com
Power Specifications
Supply Voltage: 115/230 VAC
Power Consumption: Standby: < 1.0 W
Empty: 33 W
Max load: 200 W
Fuses: 2 A T
Interface and Cable Specifications
Interfaces: RS-232
USB
Ethernet
GPIB (IEEE-488)
Connectors: IEC Inlet
Sub D-9
USB-A 2.0 (2)
USB-B 1.1
Ethernet
GPIB (IEEE-488)
Interlock
Cables: RS-232
IEC power cord
Interlock: External interlock and interlocked
laser outputs

www.ets-lindgren.com Laser Safety 17
4.0 Laser Safety
For additional safety information see the
ETS-Lindgren Product Information Bulletin
included with your shipment.
Safety Precautions
LASER RADIATION
AVOID EXPOSURE TO BEAM
CLASS 3B LASER PRODUCT
WAVELENGTH 808 nm
OPTICAL POWER 0.5 W
Never look into any of the fiber optic connectors.
The laser emits an infrared beam that is invisible
to the naked eye. Direct or even reflected light
will cause permanent eye damage.
INVISIBLE LASER RADIATION: Do not stare into
beam or view directly with optical instruments.
Avoid eye or skin exposure to direct or scattered
radiation.
Some EMCenter™ Modular RF Platform plug-in cards use a high power laser to
supply energy to a remote (floating) measuring device. The wavelength of these
lasers is approximately 808 nm. These lasers are high-power, infrared lasers and
invisible to the human eye. Please read the documentation and safety
instructions provided in the separate manual for the specific card.

18 Laser Safety www.ets-lindgren.com
Exposure to any laser radiation during normal operation is not likely because the
EMCenter uses only fiber-coupled lasers. However, for the safety of all
employees, please comply with the following rules:
When the EMCenter is not in use, power off the unit.
The remote interlock connection should be connected to an emergency
master disconnect and in series with the room door or fixture
interlocks.
Connect all fiber cables and install protective covers before switching
on the system. Protective covers are identified by the following label:
Do not attempt to turn on the EMCenter if the fiber optic cables show
any sign of damage.
Safety Features
To make the EMCenter as safe as possible, the primary safety system of each
plug-in card is designed to work standalone, without any intervention from the
EMCenter. Apart from this, the EMCenter has its own safety interlock system,
which is connected in series with the interlock system of every installed card.
Additionally, the following safety measures are implemented:
The EMCenter is equipped with a remote interlock system. For
example, this interlock system would prevent inadvertent laser
radiation by preventing someone from entering a shielded room and
stepping on a fiber.
To prevent accidental activation of the laser, an Acknowledge button
will appear directly after the Laser Start button is pressed. The laser
will start only if this button is pressed within a four-second timeframe.
A visual Laser On indicator warns the operator of laser activity. The
Laser On LED on the front panel of EMCenter indicates that at least
one laser is active.

www.ets-lindgren.com EMCenter Controls and Connectors 19
5.0 EMCenter Controls and Connectors
Never disconnect the fiber optic cables when
one of the lasers is active.
See Manual Control of the EMCenter on page 25 for information on
using the touchscreen controls.
Front Panel
S
TATUS
I
NDICATORS
There are four status indicators on the front panel of the EMCenter™ Modular
RF Platform:
Interlock—Illuminates if the external interlock is open, or if one of the
plug-in card interlocks encounters an interlock error.
Laser On—Illuminates if at least one of the lasers in one of the cards
is active.
Standby—Illuminates when the EMCenter is in standby mode.
Power On—Illuminates when the EMCenter is turned on.

20 EMCenter Controls and Connectors www.ets-lindgren.com
Back Panel
Slots 1 through 7—Allow you to install a combination of ETS-Lindgren
plug-in cards: EMSwitch™, EMPower™, EMControl™, and
EMSense™. For more information on the cards, see EMCenter Plug-In
Cards (Optional) on page 8.
Slot 8—Dedicated to the processor card for the embedded Linux
computer. The processor card also provides these connectors:
RS-232 Serial interface bus to interface with a computer.
Use a straight (pin-for-pin) cable with sub-D9
connectors.
The baud rate is 57k6, with no parity, 8 bits and
1 stop bit.
LAN Local Area Network connection used to update
the operating system and application software on
the EMCenter.
USB USB-A: USB device connection for a pointing
device or keyboard.
USB-B: The EMCenter can act as a USB
device when connected to a computer.
Table of contents
Other ETS-Lindgren Measuring Instrument manuals

ETS-Lindgren
ETS-Lindgren OMS User manual

ETS-Lindgren
ETS-Lindgren HI-1501 User manual

ETS-Lindgren
ETS-Lindgren HI-3638 User manual

ETS-Lindgren
ETS-Lindgren 5225 Series User manual

ETS-Lindgren
ETS-Lindgren HI-1801 User manual

ETS-Lindgren
ETS-Lindgren HI-1501 User manual

ETS-Lindgren
ETS-Lindgren HI-2200 User manual

ETS-Lindgren
ETS-Lindgren HI-4433 User manual

ETS-Lindgren
ETS-Lindgren HI-6100 User manual

ETS-Lindgren
ETS-Lindgren HI-3604 User manual