ETTI E055 User manual

ETTI
60V 250A Power Analyzer
ETTI
Power Analyzer(60V)
IN
Display Slot
+
+
S
USB
Power Input (5-15V)
RPM Sensor Input
Motive Power Input
6-60V
Power Supply:
5-15V
+
+
+
-
-
-
Power Output Device
01
Attentions :
1. Avoid in contact with flammable, alkaline and acidic substances.
2. Avoid direct contact with water.
3. Do not reverse the polarity of the electrical supply input, it may damage the device.
4. Keep the product away from magnetic field such as iron, nichrome, battery and motor should not be
placed within 25mm. This is to assure the measuring accuracy of the device.
5. Extra attention: Any signal made by wireless or telecom device during analyzing process may cause
discrepancy to the sample result.
1. Range of auxiliary voltage: 5V – 15V
2. Range of allowed analyzing voltage: 0V – 60V
3. Maximum testing current: 250A
4. Net weight: about 30g
5. Size: 50 x 30 x 11mm
Specifications :
This device specializes in testing the output performance of the power cell as well as the rotational
speed of the brushless motor. It can perform real time monitoring, sampling, recording and analyzing.
With the help of the analyzing software, users can observe the change in output electric current,
voltage, rotational speed of the motor in a certain time interval, so that they can assess the cell capacity
and motor combinations and hence make evaluation. Owing to its small size and light weight, users can
obtain a live and actual sample data in its voyage, in order to choose the best cell and motor combination.
The device can work stably and shows a clear and accurate result. It is mainly used for RC Plane, boat
and car and scientific research of power cell monitor, analysis and configuration.
Assemble the device on the equipment that is going to be checked, connect it in between the electrical
supply and the equipment. (Please follow the label on the device for the input and output direction,
reverse connection of the polarity may cause permanent damage to the device.)
The Power Analyzer package includes:
1. Power Analyzer
2. LCD Operation Panel
3. USB data wire
4. 4pin display wire
5. software CD
Characteristics :
Connections :
ETTI
Power Analyzer(60V)
IN
Display Slot
+
+
S
Ch1
BEC
or
Battery
Ch2
Ch3
Batt
USB
Power Input (5-15V)
RPM Sensor Input
Motive Power Input
6-60V
+
+
-
-
Power Output Device
Receiver
A. B.
+
S

ETTI
60V 250A Power Analyzer
Usage :
Power indicator
Data indicator
Clear memory
Power Input
RPM Input
Display slot
USB plug
Motive Power Input
Display
SET
UP
DOWN
EXIT
Display connection
1
ETTI
Power Analyzer(60V)
IN
Display Slot
+
+
S
USB
Power Input (5-15V)
RMP Sensor Input
Software of the operation panel:
Connect the Power analyzer with the device using
the data wire, after the power analyzer has
electrified, the LCD operation panel shows the
software version of the Portable LCD operation Panel.
It will then enter the following options:
1. PeakValue (Peak value)
Minimum voltage (V min) / Maximum electric cur
rent (A max) / battery Consumption (Used), Maxi
mum display value 65534mAH / Used power
(Power)
2. Data History (Complete set of data history)
3. Data clearance (Deletion of data)
4. Instant Value (real time value)
Voltage / Electric current / Power / Rotational
speed
5. Parameter Set (Setting of parameter)
Sampling Interval (Sampling interval)
Startup Amp (Initial electric current)
Sampling Defer. Defer. = Deferment (Deferred
sampling)
Pole of motor (Pole of brushless motor)
Write Data (Input of data)
6. Read PA Version (Read the software version
of the power analyzer)
Instruction of indicator condition :
Sample awaiting status: Flashes alternatively in 1 second
Sampling status: Flashes quickly
Complete sampling: Lasting bright
Connection to data bus :
Connect the Power Analyzer to the USB port of the computer using the USB data wire
No external electricity is required
Recording :
Electrifying: Open the electrical supply when the device is connected.
History clearance: Press and hold the button for 3 seconds to clear the last record.
The device cannot execute new sampling when the last history is not cleared.
Start recording: Export an electric current which is equal or greater than that of the start up value,
the analyzer will start recording after the preset deferred starting time, the indicator will flash quickly.
Sampling process should be completed as a whole, no interruption is allowed.
Completion of sampling process:The indicator lasts lighting up.
2
ETTI
1

ETTI
60V 250A Power Analyzer
I. Installing software for power analyzer
a. Insert the CD into CD/DVD ROM
b. Inside the folder of Power Analyzer PC software, double click SETUP, the installation wizard will
start to operate.
c. Click NEXT in the “welcome to the InstallShield Wizard for Power Analyzer” interface.
d. In the Destination Folder, user can choose to change the location of installation; or just click
NEXT to continue.
e. In the “Ready to Install the Program”, click “Install”, the software will then be installed
automatically to the computer.
f. In “InstallShield Wizard Completed”, click “Launch Power Analyzer” to run the software, then
press Finish.
II. Installing the USB drive
It is required to install the USB drive before usage, in order to ensure the data exchange of the
power analyzer and the computer.
a. Connect the power analyzer to the computer through the USB wire. Do not disconnect the
USB wire during installation. The system will detect new hardware and the installation wizard
will execute.
b. Select “No, not now” in the “Welcome to hardware installation wizard” then press “Next”.
c. Choose “Select from list/destined location” and press “Next”
d. Insert the Power Analyzer installation CD, click “Browse” to nd the “USB driver” directory,
then click “Next”.
e. The computer will nd the driver and start installing, click nish.
f. At this time, the computer will nd another new hardware, the installation method will be the
same as above (a-e)
g. After the completion of the two driver installations, the power analyzer will be able to connect
to the computer to download required data.
Setting
Through the software setting (Open the software, software setting interface)
1. Serial port selection
Set COM1~COM15 to choose the data interface of the computer. (when several serial ports are in
use.)
Firstly, check the serial port setting of the computer: Control>System>Hardware>Driver>(COM &
LPT),
Find the serial number for the connectable COM, choose the corresponding COM serial port in
the Serial port setting] and test its communication status.
Installation of computer software :
3

ETTI
60V 250A Power Analyzer
Setting :
II. Setting of sampling time interval
Sampling time interval 0.1s ->Total recording time lasts for 8.3 minutes
Sampling time interval 0.2s ->Total recording time lasts for 16.7 minutes
Sampling time interval 0.3s ->Total recording time lasts for 25 minutes
Sampling time interval 0.4s ->Total recording time lasts for 33.3 minutes
Sampling time interval 0.5s ->Total recording time lasts for 41.7 minutes
Sampling time interval 0.6s ->Total recording time lasts for 50 minutes
Sampling time interval 0.7s ->Total recording time lasts for 58.3 minutes
Sampling time interval 0.8s ->Total recording time lasts for 66.7 minutes
Sampling time interval 0.9s ->Total recording time lasts for 75 minutes
Sampling time interval 1s ->Total recording time lasts for 83.3 minutes
III. Setting of the operating electric current
User can set the operating electric current ranging from 3A to 30A.
VI. Deferred starting, time setting:
Set the deferred starting time after the operating electric current has reached the required value,
from 1 second to 10 seconds.
V. Setting of pole of motor
Setting of the pole of motor to test the accurate rotational speed of the motor.
Recording
Electrifying: Open the electrical supply when the device is connected. History clearance: Press and hold
the button for 3 seconds to clear the last record. The device cannot execute new sampling when the
last history is not cleared.
Setting of the operating electric current: Export an electric current which is equal or greater than that
of the start up value, the analyzer will start recording after the preset deferred starting time, the indica-
tor will ash quickly. Sampling process should be completed as a whole, no interruption is allowed.
Completion of sampling process: The indicator lasts lighting up.
4

ETTI
60V 250A Power Analyzer
Downloading
Connect the data wire and wait until downloading is completed. See below for the record analysis inter-
face.
Voltage: Blue line
Electric Current: Red line
Rotation: Green line
Specications
Working voltage: 0~60V
Testing current: 0~250A
Electric current sampling A/D resolution: 10bit
Electric current resolution: 0.244A
Voltage dissolution: 0.0586V
Size(exclude wires and cables): 30mm×50mm×11mm
Weight: about 30g
Setting :
5
Table of contents
Popular Measuring Instrument manuals by other brands

Level Pro
Level Pro TVF Series Quick start user manual

Corelis
Corelis BusPro-I user manual

Praxair
Praxair StarWatch user guide

SRS Labs
SRS Labs SXMCMTU64 installation instructions

Elesa
Elesa DD52R-E-RF Instructions for use

Electro Industries/GaugeTech
Electro Industries/GaugeTech Nexus 1450 quick start guide

Siemens
Siemens ULTRAMAT 23 operating instructions

Acoustical Systems
Acoustical Systems UNI P2S owner's manual

Veris Industries
Veris Industries Hawkeye H749 installation guide

Thermo Scientific
Thermo Scientific Star Series user guide

Honeywell
Honeywell HG4930 Installation and Interface Manual

Reinhausen
Reinhausen MESSKO MTO Series operating instructions