EUROM B950I User manual

User manual
B950I, B1000i, B2000i, B3000i

Page 20
•Always read the user manual thoroughly before using the generator.
•Never use the generator in a closed room/area. Exhaust may cause suffocation.
•The exhaust pipe becomes very hot during operation. Do not touch the exhaust pipe after use.
•Only use approved cables.
•Fuel is very flammable, be careful when filling with gasoline. Do not fill when you are close to open
fire, lighted cigarettes, sparks or similar. Always clean up spilled gasoline.
•Standby power generators for buildings must only be connected by an authorised electrician, who
must comply with the regulations in question. Incorrect connection can make the power/electricity
run back to the generator. This can cause an electric shock if a person gets in contact with the
generator. After the power has been restored the generator may explode, burn or cause a burn in
the electric system.
•Always inspect all connections before you start the machine. This can prevent an accident.
•Always place the generator 1 meter away from buildings or other equipment during operation.
•Only use the generator on a horizontal surface.
•Draw attention to how the generator is to be stopped and understand all its functions. Never leave
the use of the generator to persons who has not received any instruction about the operation.
•Keep children away from the generator during operation.
•Using the generator with wet hands may lead to electric shock.
•Never use the generator in rain or snow. Always make sure that the generator does not become
wet.
NOTE If you are going to use the generator in thin statums of air, higher than 1500 meter above water
surface you shall contact your dealer for guidance.

Page 21
1. Contents
1. Contents...........................................................................................................................................21
2. Identification of components ...............................................................................................................22
3. Automatic current control (SMART).....................................................................................................22
4. Before start - Oil ................................................................................................................................23
4.1. Before start - gasoline .................................................................................................................24
4.2. Before start - air filter...................................................................................................................24
5. Start .................................................................................................................................................25
6. Operation of the generator .................................................................................................................27
6.1. Alternating current ......................................................................................................................27
6.2. Indicators ...................................................................................................................................28
6.3. Direct current..............................................................................................................................28
6.4 Oil warning..................................................................................................................................30
6.5 Stop ...........................................................................................................................................30
7. Maintenance ....................................................................................................................................31
7.1 Changing oil................................................................................................................................31
7.2 Air filter .......................................................................................................................................32
7.3 Spark plug ..................................................................................................................................33
8. Transport and storage........................................................................................................................33
9. Specifications....................................................................................................................................35
10. Trouble shooting..............................................................................................................................36
Spare parts
Part list and explosive drawings for the specific product, please contact your
dealer.
If you help find part numbers yourself, it will ease the service.
For purchase of spare parts, please contact your dealer.

Page 22
2. Identification of components
3. Automatic current control (SMART)
The engine speed is automatically adjusted, when the current is disconnected. The same way the speed goes
up when you connect the current. This ensures the fuel consumption being held at a minimum.
Warning - The automatic regulation does not work effectively if an even electric current is needed.
Warning - When the generator is to produce a heavy, even current you shall place the switch in
the OFF position in order to reduce changes in the current.
Warning - When you work with DC (Direct Current), always place the switch in the OFF position.
Choker
Cover
Starter
Engine switch
Control panel
Fuel cap
Fuel cap cent
lever
Cover for
fuse
Muffler
DC
receptable
Smart contact
Smart-Throttle switch
Over load indicator
Ground
terminal
Oil indicator
AC
DC circuit
protector
Switch

Page 23
4. Before start - Oil
NOTE
-Always inspect the generator on a horizontal surface with a turned-off engine.
-The in-built alarm system will automatically stop the engine before the oil level drops under the
approved level. In order to avoid unpredicted disconnection you shall check the oil level regularly.
-Using the generator with too little oil can cause severe damages to the wear parts of the engine.
Use full-synthetic premium 4-stroke oil, which meets the demands in question.(API)
Loosen the screws that tighten the plate on the backside of the generator and remove the plate. Check the oil
level by removing the oil stick, clean it with a dry clean cloth. Insert the oil stick without screwing it in. See the
oil level on the stick. Fill with oil if necessary.
Oil capacity: 0,25/0,40 L.
Oliepind
Fill oil until here
Screw
Left maintenance
cover
Air cleaner
cover
Oil stick
Oil filler hole
This manual suits for next models
3
Table of contents
Popular Inverter manuals by other brands

BARRON
BARRON EXITRONIX Tucson Micro Series installation instructions