I.Instruction
III. Maintenance
1、Placed sole cleaning machine on flat ground;
2、Placed dry pad on cover plate, side of dry pad into quadrilateral frame;
3、Unlock on two sides, then open the cover, please referring to Figure1.1;
4、Add water, level line between “min” and “max”;
5、Close the cover slowly and lock it, connect the power.
6、Before removing make sure it locked
1、Cleaning machine: Regular clean the dust of the machine and brushes surface dirty.
2、Cleaning dry mat: Clean once every day, or more times than that, just depend on the actual situation to keep
the dry mat clean and absorbing effect. After cleaning, reset the mat to dry zone. Do not wring dry mat to
prevent damage. If you don't use the mats, seal it with plastic film.
3、Changing water:
1) Power off, unlock two sides, lift up cover;
2) Back tank, referring to figure 3.3.1;
3) Lift tank handle, referring to figure 3.3.1;
4) Out of tank, water pouring, cleaning tank, add water to the liquid level scale, referring to figure 3.3.2;
5) Replace the tank;
6) Close cover slowly and lock it, then connect the power.
第六步,手扶着上壳慢慢放下,锁住锁扣,接通电源。
II. Usage
1、Pls stand upon clean zone as arrow
For the best cleaning result, pls pass through cleaning and dry zone referring to Figure 2.1-2.2. First the
cleaning zone. On the dry zone stay 2 seconds. More time cleaning, the effect will be better.
2、Piaffe 4 times
3、Pls walk to the dry zone, stay 2s
around.区。
Clean zone
Figure2.1
Dry zone
Figure2.2
Power interface
Tank
Sensor
Handle
Figure1.1
Cover
Lower casing
Holder
Lock
Level indication

2
Questions
Reason
Troubleshooting
Machine doesn’t work
Loose power outlet
Check power plug
Perception sensor
fault
Check the sensor indicator light.
Brush doesn’t work
Loose Brush
Adjust brush by hand(Check Routine Maintenance No. 4).
Human absent, still work
Sensor is blocked
Make sure there is no obstruction above the sensor and clean the sensor surface.
Type
Dimension
Clean zone
Dry zone
Water tem.
Tank
ESCD3
900×470×85mm
345×325mm
335×325mm
0-40℃
4L
Voltage
Power
Noise
Overload
N.W
220V/50HZ
75W
<60db
150Kg
25Kg
Sole cleaning machine operation manuals
IV. Common trouble shooting
V. Specifications
4. Adjust the brushes: When the machine is running normally, you find the brushes do not work, then you
should adjust tension bolt tight.
① Power off, unlock two sides, lift cover;
② Find the brushes tension bolts (check Figure4.1), tighten it;
③ Both sides of a total 4 tension bolts are required to maintain a consistent adjustment, to ensure the equipment
work properly.
④ Connect the adapter, check brushes whether running normally, if the brushes still do not work, please repeat ①,
②,③ above, adjust the tension bolts, until the brush work.
Figure 4.1
Figure 3.3.1
Figure 3.3.2
Tension bolts

3
Sole cleaning machine safety Instructions
A, Product Overall Schematic Diagram
B, General Terms and Conditions of Technical
C, Reminder of Cleaning Effect
Under the reasonable consider, EURONICS have the right to amend technical documentation and improve the products.
Received technical documents (especially the user documentation) does not represent EURONIC have duty to bear on
the responsibility of the product and technical information for further modification. About the applicability of the product
in your specific application and intended use, especially the using standards and regulations, should be up to you to test.
All the information provided in the technical documentation comes with no guarantees, whether express, implied or
default.
In general, technical document only applies to the current standard terms and conditional content of EURONICS,
especially the liability for the guarantee part.
This manual, including all of the illustrations are protected by copyright, the content of document and
extracts can not made any changes.
EURONICS reserves registration of intellectual property rights for all of the sole cleaning machines in this document. The
third party should not register the intellectual property rights. The other product descriptions do not according to this
manual also can be protected by the legal.
Cleaning effect mainly depends on the brush and clean water (or disinfect water)properly or not
Notice: 1. Use appropriate brush and filtering materials.
Inferior brush will lead to fast wear, reduce the cleaning effect, inferior filter material can lead to clean water secondary
pollution, reduce the cleaning effect, recommend Purchasing high quality cleaning material, or choose EURONICS original
consumables.
3. Use clean water.
Clean water temperature should be between 0 ℃to 40 ℃, using the other temperature water will aging or damage the
brush.
3Please keep dry pad moist state
Dry pad, please be sure to keep the wet state, if it becomes dry, it will become hard, will lead to a decline in water
absorption and dry pad damage.
Dry zone
Clean zone
Power interface
Sensor

4
No.
Name of goods
Quantity
Remark
1
sole cleaning machine
1
2
Leak protection safety adapter
1
3
Dry pad
2
4
Usage manual
1
5
Operating direction
1
6
Warranty card
1
7
Quality pass certificate
1
8
Six angle wrench
1
Sole cleaning machine safety instructions
D、Safe tips
E、Packing list
The equipment is a special industry sole cleaning machine, the motor drives the rotation brush to cleaning.
1、•The equipment is in accordance with advanced technology standard and recognized safety regulations, however,
when using the equipment may still cause life hazard to users or others, or cause the loss of the equipment and
other property.
• The device must be used in good condition, and to comply with the operating directions, according to the
Application carefully used with caution.
• The device is only applicable for flat shoe sole. Any other use or abuse is in violation of usage. The damage
caused by improper use, the manufacturer / supplier will not be responsible for the user who assumed the risk.
• Follow the operating instructions, including the provisions and recommended repair, which is part of regulation.
2、Safe tips
• Please execute only the instruction in the operation described.
• This equipment is suitable for the voltage of 220V AC power supply. It must be connected to the power
Supply socket and contact earth wire.
• This device can not work in explosive gas environment.
• The device can't work near the high voltage power lines.
• The device and its components can generate heat at work. Do not touch at running.
• Replacing supplies before dismantling need waiting for cooling.
• Different devices risk warning label on the device. Do not remove the label, or may not recognize the danger.
• Other work only by trained personnel and customer service completed.
• In order to ensure the safety of the elderly need accompanied by others, the children prohibit using this
Equipment.
• No playing, sitting, lying on the device.
• Avoid items fall into the sole cleaning machine, so as not to damage the equipment or the filter and blockage of
Water pumps.
• Please stand when using, pay attention to avoid clothes, hair accessories, and other personal items and exposed
contact rotating parts.
This manual suits for next models
1
Table of contents