Welcome to use BodyShape RF Therapy system.
This product is a patented product of Wingderm Electro-Optics Ltd. It is illegal
for any imitation and counterfeiting to be conducted without the company's
permission.
Statement: Within one year from the date of signing the purchase agreement,
the company is responsible for free maintenance due to product quality
problems caused by the product materials and processes. The consumables of
the machine are not free to repair! Due to human negligence, environmental
factors, accidents, alterations, and improper maintenance, machine failures
are not included in free
maintenance.
If the system fails during startup or normal operation, immediately switch off
the power and contact our customer service department. Only technical
personnel authorized by our company can repair the instrument. We do not
assume
any
responsibility for the maintenance of the instrument by non‐
authorized personnel.

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
2 / 23
Contents
Chapter 1:Introduction .............................................................................................................................................. 3
Chapter 2:ProductDescription................................................................................................................................. 3
2.1
Product StructureDescription ........................................................................................................................... 3
2.1.1
Mainframe............................................................................................................................................................ 3
2.1.2
WSculptor Applicator.......................................................................................................................................... 5
2.1.3
WTighten Applicator ........................................................................................................................................... 6
2.2
Operation Interface Description....................................................................................................................... 8
2.2.1
Welcome interface .............................................................................................................................................. 8
2.2.2
Password logininterface.................................................................................................................................... 8
2.2.3
Modify or reset new password interface ............................................................................................................ 9
2.2.4
Work interface ..................................................................................................................................................... 9
2.2.5
Setting interface ................................................................................................................................................ 11
2.3
Consumable Assembly Description .............................................................................................................. 12
2.3.1
WTighten Applicator Consumable Assembly Description ............................................................................. 12
2.3.2
WSculptor Applicator Consumable Assembly Description ............................................................................ 13
2.4
Mainframe Assembly Steps ........................................................................................................................... 13
Chapter 3:PrinciplesandApplication..................................................................................................................... 17
3.1
Technical principle
.............................................................................................................................................. 17
3.2
Application ........................................................................................................................................................ 18
Chapter 4:Operation Procedure ............................................................................................................................. 18
Chapter 5: Contraindications................................................................................................................................. 18
Chapter 6:Precautionsafternursing ...................................................................................................................... 19
Chapter 7:Repair andMaintenance........................................................................................................................ 19
7.1
Maintenance ......................................................................................................................................................... 19
7.2
Common Troubleshooting .................................................................................................................................. 21
7.3
Disposal ................................................................................................................................................................. 22
7.4
Packing List
............................................................................................................................................................ 22
7.5
Machine Parameters............................................................................................................................................. 23
Chapter 8: Contact Us ............................................................................................................................................. 23

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
3 / 23
Chapter 1:Introduction
The machine integrates bipolar radio frequency, infrared, vacuum, automatic mechanical
massage and infrared temperature measurement, which can be used for body shaping,
dimensional reduction, etc.
Chapter 2: Product Description
2.1
Product StructureDescription
2.1.1
Mainframe
Front view
Explanation:
①LCD screen: This product adopts 10.4 inch touch screen. All parameter settings,
system control and equipment status are operated and displayed on the LCD.
It is forbidden to touch the surface of screen with sharp objects to prevent from
scratching on the surface to result in touch failure.

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
4 / 23
Various liquids are prevented from splashing onto the surface of the control
panel, causing damage.
②Power switch: The power button is used to start and shut down the system.
Pressed the button, the power is on; popped the button, the power is off.
③Mainframe handle: for moving the equipment.
④WSculptor Applicator: for treating larger areas, such as the abdomen.
⑤WTighten Applicator: for treating small areas, such as the arm.
Rear view
Explanation:
①Filter maintenance port: mainframe filter placement site, for replacing the filter core; this
part is fixed by hinge and magnetic.
②Power input;
③WSculptor Applicator connector;
④WTighten Applicator connector.

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
5 / 23
2.1.2
WSculptor Applicator
Side view
Explanation:
①Switch button: for controlling the operation state of Applicator.
②Locker: for removing accessible parts.
③Touching part: the partof applicator contacting the human body. We suggest every
person uses one individually to avoid cross‐infection.
Top view

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
6 / 23
Explanation:
①Level indicator: Each function has five lights, corresponding to 6 states. The indicator light is
holographic, indicating no corresponding energy output.
②IR button: for adjusting IR level.
③RF button: for adjusting RF level.
④Negative pressure button: for adjusting vacuum level.
Bottom view
Explanation:
①Infrared light outlet: the outlet of IR rays, for heating epidermis.
②Body temperature detection port: body temperature detection part, for real‐
time monitoring of human body temperature during treatment.
③Roller: controlled by precision motor, for massaging the skin.
④Electrodes: RF energy output electrodes, both electrodes need to contact
skin during the treatment.
2.1.3
WTighten Applicator
Side view

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
7 / 23
Explanation:
①Infrared light outlet: the outlet for IR rays, for heating epidermis.
②Electrodes: RFenergyoutput electrodes,both electrodes need to contact skin during the
treatment.
③Air inlet: can not be blocked.
Top view

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
8 / 23
Explanation:
①Switch button: for controlling the working status of the applicator.
②Level indicator: Each function has five lights, corresponding to 6 states. The
indicator light is holographic, indicating no corresponding energy output.
③IR button: for adjusting IR level.
④RF button: for adjusting RF level.
⑤Negative pressure button: for adjusting vacuum level.
2.2
Operation Interface Description
2.2.1
Welcome interface
2.2.2
Password login interface

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
9 / 23
2.2.3
Modify or reset new password interface
2.2.4
Work interface

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
10 / 23
The WSculptor applicator and the Wtighten applicator can be chose in this interface.
Each applicator has two modes: Smooth and Shape. Switching is done through the
Smooth and Shape buttons on the screen.
Work Interface
Setting button: click on the upper left corner to enter the setting interface.
IR: indicating the infrared intensity, the volume is 0-5. Click the center to adjust, or slider
adjus. The default value is 0.
RF: indicating the RF intensity. Same to IR.
Vaccum: indicating negative pressure intensity. Same to IR.
Working mode: You can click button to select the working mode, including Smooth
mode and Shape mode.
Applicator selection: click the applicator icon on the screen to switch applicators, the
defaultis Wsculptor Applicator
Body part: click to switch the body parts; switch the front and back of the body by
clicking the buttons on the left and right sides of the body.
Total working time: total working time of the treatment.
Start/Pause: Press this button, the system enters the ready state, and the button
displays the word “Pause”. At this time, the applicator can be controlled. In this state, the

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
11 / 23
parameter cannot be adjusted. Click this button again. The system enters the standby
state, the button displays the word “Start”, the applicator can not be controlled to work,
and you can adjust the parameters. Default standby state.
Current temperature: the skin temperature is displayed.
2.2.5
Setting interface
Host serial number: the serial number of current mainframe;
Host version number: the version number of current mainframe;
Software version number: the version number of current software;
WSculptor Applicator serial number: the serial number of the WSculptor Applicator;
WSculptor Applicator version number: the version number of the WSculptor
Applicator;
WTighten Applicator serial number: the serial number of the WTighten Applicator;
WTighten Applicator version number: the version number of the WTighten
Applicator;
Button mode: switch click mode and hold mode by clicking the button;
Temp Setting: click the temperature value, pop up the digital input box, and set the end
point of the skin temperature, in degrees Celsius.

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
12 / 23
Language setting: click the button to choose, which has two language, Simplified
Chinese and English.
Volume adjustment: adjust the volume. Mute on the far left and largest on the far right.
Cumulative treatment time: the total treatment time of current machine since delivery,
in unit of minutes;
Cancel: click the "Cancel" button to return to the operation interface without saving the
settings;
OK: Click the "OK" button to save the settings and return to the operation interface;
Engineer Mode: click the button, input the password, enter the engineer maintenance
interface; (Engineering Use Only)
2.3
Consumable Assembly Description
2.3.1
WTighten Applicator Consumable Assembly Description
Align the connectors and install until they do not fall off. Showed as below.

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
13 / 23
2.3.2
WSculptor Applicator Consumable Assembly Description
Align the connectors and install until they do not fall off. Showed as below.
2.4
Mainframe Assembly Steps
1. Assemble the left and right applicator respectively according to the direction shown.
A
A
2 1
A
2 1
A

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
14 / 23
2. Put the decorative cap into the left elbow, then install the WSculptor applicator bracket
and tighten the screws.
3. Put the decorative cap into the right elbow, then install the Wtighten Applicator bracket
and tighten the screws.
4. Put the decorative cap into the vertical pipe elbow, then cap the pipe clamp and front
pipe clamp into the vertical pipe elbow in sequence, and tighten the screws.

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
15 / 23
1.
2.
3.
5. Install two sets of poles as shown below:
6. Install the pole bends separately with M3*25 screws as shown below.

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
16 / 23
A
A
2:1
7. Place the applicator on the applicator bracket and clamp the cable tube. Insert the
WScuptor Applicator(left) and WTighten Applicator(right) connector the rear socket of the
mainframe according to the label prompt until you hear the “Kada” sound.

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
17 / 23
8.Turn on the power cord and press the power button to start.
Chapter 3:PrinciplesandApplication
3.1
Technical principle
The rapid generation of thermal energy in the body by radiofrequency can stimulate
the proliferation of collagen cells, achieve firming effect and make the body fat cells
produce a strong impact and frictional movement between fat cells, effectively
consuming calories and reducing fat cells; when the vibration frequency reaches After
a certain range, cells have a strong impact, and the cells burst instantaneously, reducing
fat cells. The bioenergy effect can rapidly enhance local blood circulation, and quickly
activate lipase, accelerate triglyceride cleavage in subcutaneous fat cells into
free fatty
acids and glycerol, and excrete through liver metabolism.
Infrared radiation can heat connective tissue fibroblasts and accelerate the
regeneration of collagen and elastin fibers.
When RF and infrared light are used in combination, light energy is used to adjust the
impedance value in the body to reduce the impedance force of the epidermis to the
radio frequency, guide energy concentration deep into the connective tissue, increase

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
18 / 23
the effect on deep tissue, and use the skin to selectively absorb light energy. The
difference between the target tissue and the normal skin impedance, in the case of
low light energy intensity, enhances the absorption of the target tissue to the radio
frequency, eliminates the side reactions (blisters/pigmentation) that may be caused
due to the excessive thermal effect of light energy, and improves Customer comfort;
Electromagnetic energy is used as a "catalyst" of light energy to supplement the
deficiency of electromagnetic energy with light energy, reduce the ability of deep
lesions, and reduce the chance of skin burns.
3.2
Application
The system can reduce the size of the buttocks, legs and arms, and reduce
abdominal fat and orange peel.
Chapter 4: Operation Procedure
1. The machine starts and enters the welcome screen. This interface can display the product
name BadySape, company LOGO, interface software version number, host software
version number and left and right applicator software version number.
2. After the above information is displayed on the welcome screen, the password keyboard will pop up
automatically. Enter the correct password to enter the next interface. There will be a prompt box for
incorrect password input. Click the eye icon to display the entered password in clear text. To modify
or reset the password, click the “Modify” button on the password keyboard to enter the password
modification or reset interface.
Note: Instrument initial password: 123456
3. After entering the correct password, it will automatically enter the work interface. Set the working
mode on this interface, set the applicator to be used, select the body part, then adjust the values of
infrared, radio frequency and negative pressure, and click “Start” to operate.
Represents the WTighten applicator; represents the WSculptor applicator; if the
applicator is not inserted, it will not be displayed after clicking.
4. Start the applicator by pressing the applicator button. After use, click the “End” button on the
operation interface to complete the treatment.
5.
Chapter 5: Contraindications

R530008-V1.0 WRD-01BodyShape RF Therapy System USER MANUAL
19 / 23
(1)
Those who have a heart attack or have a pacemaker;
(2)
Pregnant women;
(3)
Artificial fillers have been injected into the area, such as silica gel;
(4)
Patients with diabetes and malignancy;
(5)
Those who are scarred;
(6)
Patients with acute dryness;
(7)
Open wounds or those who are taking anticoagulant drugs in the applicable area;
(8)
Those who have a history of photosensitivity;
(9)
Those who have undergone liposuction surgery in the applicable area;
(10)
Patients with systemic lupus erythematosus;
(11)
People with mental disorders;
(12)
Theuseof immunosuppressivedrugsorthosewithinhibitorydiseasessuchas AIDS.
Chapter 6:Precautions after nursing
(1)
Since infrared light and radio frequency increase the speed of blood supply in the local
area, temporary erythema and edema may occur in the local treatment area, and
it will
disappear in about several hours.
(2)
Since this system incorporates infrared light and electromagnetic waves, do not
perform intense sunbathing within one week after treatment, such as beach
sunbathing. At the same time, the treatment area needs to strengthen the hydration
and
protectionwork.
(3)
As the system can promote the metabolism of adipose tissue, fat cells are dissolved and
absorbed by the lymphatic system. After a comfortable and complete treatment, the person
being treated may find that the day's urine output increases. But in general, the patient feels
relaxed and enjoys the treatment process. Negative pressure and
roller design make the
treatment process feel like a hot massage.
Chapter 7:Repair andMaintenance
7.1
Maintenance
Table of contents