EVoCharge 30A EVSE EV072-300-001A Assembly instructions

INSTALLATION GUIDE
AND USER MANUAL
Electric Vehicle
Charging Station
Model: 30A EVoCharge EVSE
Model Number: EV072-300-001A
Product Safety Certification: UL and cUL Listed
Description: SAE J1772 AC Level 2, 30A (7.2 kW) Continuous Rated EV Charger v2.1

©2012-2015 EVoCharge - All Rights Reserved
All information in this document is subject to copyright and other intellectual property rights of EVoCharge. This material may not
be modified, reproduced or copied, in whole or in part, without the prior written permission of EVoCharge. EVoCharge and EVoReel
are trademarks of EVoCharge. All other trademarks contained in this document are the property of their respective owners and
their use herein does not imply sponsorship or endorsement of their products or services. All specifications and descriptions
contained in this document are verified to be accurate at the time of printing. However, to support continuous improvement,
EVoCharge reserves the right to make product modifications at any time without notice. Updated installation guide and users
manual is available at www.evocharge.com
2
IMPORTANT
Read this manual thoroughly and make sure you understand the procedures before you attempt to
install or operate this equipment. The purpose of this manual is to provide you with information
necessary to safely install, operate and maintain this equipment. Keep this manual for future
reference.
EVoCharge recommends the Charging Station be installed by a qualified electrician, and installation
must be in accordance with all applicable state, local and national electrical codes and standards.
Failure to observe this precaution could result in death or severe injury.
Warranty: The Charging Station is covered by a two year limited warranty. For a detailed
description of this warranty, contact EVoCharge:
Telephone: (800) 930-9450

3
MANUAL CONTENT
SAFETY INFORMATION…………………………………………4-5
IMPORTANT REFERENCE INFORMATION………………6
SPECIFICATIONS…………………………………………………...7
FEATURES…………………………………………………………….8
INSTALLATION PLANNING & SERVICE WIRING……..9
INSTALLATION………………………………………………………10-22
OPERATION………………………………………..………………..23-24

SAVE THESE SAFETY INSTRUCTIONS
•The Charging Station must be grounded through a permanent wiring system or an equipment grounding conductor.
•Do not install or use the Charging Station near flammable, explosive, harsh, or combustible materials, chemicals, or vapors.
•Turn off input power at the circuit breaker before installing or cleaning the Charging Station.
•Use the Charging Station only within the specified operating parameters.
•The Charging Station is designed only for vehicles that are compatible with the SAE J1772 AC Level 2 charging standard.
•Do not use the Charging Station if it is defective, appears cracked, frayed, broken or otherwise damaged, or fails to operate.
•Do not attempt to open, disassemble, repair, tamper with, or modify the Charging Station. The Charging Station is not user serviceable.
Contact EVoCharge for any repairs.
•Do not use the Charging Station when either you, the vehicle, or the Charging Station is exposed to severe rain, snow, electrical storm or
other severe weather.
•When transporting the Charging Station, handle with care and do not subject it to strong force, drag or step on the Charging Station.
•Do not touch the Charging Station end terminals with sharp metallic objects.
•Do not forcefully pull the charge cable or damage it with sharp objects.
•Do not insert foreign objects into any part of the Charging Station vehicle connector.
•Using with a worn or damaged AC outlet may cause burns or start a fire.
•If the AC wall plug feels hot while charging, unplug the unit and replace the AC outlet.
•To avoid a risk of fire or electric shock, do not use this device with an extension cord.
•Risk of explosion. This equipment has arcing or sparking parts that should not be exposed to flammable vapors. This equipment should be
located at least 18 inches (460mm) above the floor.
•Risk of electric shock. Do not remove cover or attempt to open the enclosure of the charger unit. No user serviceable parts inside. Refer
servicing to qualified service personnel.
•Unit will attempt to reset in fault conditions.
•This device is intended only for charging vehicles not requiring ventilation during charging.
Warning
4
-Continued on next page-
This document contains important instructions and warnings that must be followed when installing and maintaining the Charging Station

5
•Incorrect installation and testing of the Charging Station could potentially damage either the vehicle’s Battery and/or the Charging Station
itself. Any resulting damage is excluded of the warranty for the Charging Station.
•Do not operate the Charging Station in temperatures outside its operating range of -22F (-30C) to 122F (50C).
•Ensure that the charge cable is positioned so it will not be stepped on, tripped over, or subjected to damage or stress.
•To reduce the risk of electrical shock, connect only to properly grounded outlets.
•If the plug provided does not fit the outlet, do not modify the plug, arrange for a qualified electrician to inspect the outlet.
•This equipment should be installed, adjusted, and serviced by qualified electrical personnel familiar with the construction and operation of
this type of equipment and the hazards involved. Failure to observe this precaution could result in death or severe injury. The user is
responsible for conforming to all local and national electrical codes and standards applicable in the jurisdiction in which this equipment is
installed.
•Confirm with the local electrical requirements for the gauge, temperature rating, and type of wire material used for the overcurrent rating
to support a dedicated circuit of 208/240 VAC 40A upstream of two-pole circuit breaker.
•Do not use this product if the EV Cable is frayed, has damaged insulation, or any other sign of damage.
•Do not use this product if the enclosure or the EV connector is broken, cracked, open, or shows any other indication of damage.
•Lockout all electrical source circuit feeding he charging unit In the open position before beginning wiring or terminations. Failure to follow
the instructions could result in server bodily injury or death.
•This unit is rated for indoor or outdoor installation. If this unit is mounted outdoors, the hardware for connecting the conduits to the unit
must be rated for outdoor installation and be installed properly to maintain the proper NEMA rating on the unit.
•It is important that power wires are routed through an approved conduit or jacket from the circuit panel to the unit.
Caution
SAVE THESE SAFETY INSTRUCTIONS
This document contains important instructions and warnings that must be followed when installing and maintaining the Charging Station
For more information on how to charge your specific vehicle, refer to the owners manual provided with your vehicle.

•The Charging Station does not require routine maintenance however, periodic inspections should be
conducted to ensure that all parts remain in good working order and no damage exists. Do not
attempt to open, disassemble, repair, tamper with, or modify any components of the Charging Station.
The Charging Station is not user serviceable. Contact EVoCharge for any repairs.
•Periodic cleaning may be required, depending on local conditions. To avoid damaging the finish of the
Charging Station, only use an automotive grade soft cleaning cloth and a mild soap and water mixture
to remove accumulation of dirt and dust. Do not use cleaning solvents to clean any of the Charging
Station components.
•When moving or lifting the unit, always grasp the unit charger enclosure. Never attempt to lift, move,
or carry the unit by any of the electrical cables. Improper handling may cause damage to the unit.
IMPORTANT REFERENCE INFORMATION
6

SPECIFICATIONS
7
EVSE Level AC Level 2
Max Current Output 30A
Voltage Rating 208-240VAC
Max Power Output 7.20 kW
Vehicle Connector SAE J1772
Frequency 50/60 Hz
Operating Temperature -30⁰C to 50⁰C (-22⁰F to 122⁰F)
Storage/Transit Temperature -40⁰C to 60⁰C (-40⁰F to 140⁰F)
Cord Length 5.49m (18.0 ft.)
Installation Indoor/Outdoor Rated; per NEMA 3R
Mounting Wall, Ceiling, and Pedestal Options
CCID/Ground Fault Automatic Supervisory Circuit: Auto-Test & Reset
Charge Status Indicators Power/Ready, Charging, Fault
Standards & Codes Compliance SAE J1772, UL Subject 2594
Independent Safety Certification UL & cUL Listed; UL File Number: E469990
SPECIFICATIONS

FEATURES
8
FEATURES
•Simple User Operating Experience
•EVoCharge Electric Vehicle Charging Stations Deliver a Simple User Operating
Experience - Simply Plug-in the Connector to Your EV to begin Charging
•Indoor/Outdoor Rated
•EVoCharge Charging Stations are rated for both indoor and outdoor charging
and comply with NEMA 3R standards
•Fast Charge Times and Compatible with all EVs
•Charges up to 8X Faster than Standard AC Level 1 EV Chargers; Compatible
with all EV and PHEV Sold in North America
•Connector Storage and Cable Management Feature
•18 Ft. Charge Cable with Connector Holster Can be Mounted in Any Location
for Effective Cable Management and Secure Connector Storage

INSTALL PLANNING / SERVICE WIRING
9
INSTALLATION PLANNING & SERVICE WIRING
•Prior to mounting, determine location of an acceptable mounting support. The Wall or Ceiling mount
unit must be anchored into a mounting support such as a 2” x 4” stud or a solid concrete wall, using
mounting hardware that is appropriate for the surface on which you are mounting. DO NOT mount this
unit directly to a stucco/drywall/wall board. If installing on a wood stud use the lag screws provided and
ensure the mounting plate is positioned on the centerline of the stud. If mounting onto a concrete,
block, or brick wall, use an appropriate anchor for the type of wall on which you are installing the unit.
•Prior to mounting, locate an available electrical source that can support the following Input
Requirements for the Charging Station
•Per National Electric Code (NEC) requirements, to support 30A continuous output current, a
DEDICATED CIRCUIT rated for 40A; 208-240 VAC, 60 Hz, upstream of two-pole circuit breaker
located either in a panel board or load center must be used.
•The Charging Unit has a built in GFCI protection; do not provide any additional GFCI protection
upstream of the charging unit.
•The Charging Station can be connected to either a NEMA 6-50 Receptacle or it can be hardwired.
•This unit is rated for indoor or outdoor installation. If this unit is mounted outdoors, the
hardware for connecting the conduits to the unit must be rated for outdoor installation and be
installed properly to maintain the proper NEMA rating on the unit.
Important: The service wiring in this section are specific to North America only.
Warning: Before installing the Charging Station, identify the type of utility service connection available onsite. If
you have unsure about the type of connection available at the service panel, contact your utility service provider.

INSTALLATION
10
INSTALLATION
STEP 1 –Verify Received Content
-Continued on next page-

INSTALLATION
11
INSTALLATION
STEP 1–Verify Received Content

INSTALLATION
12
INSTALLATION
STEP 2 –Mounting the Charging Unit

13
INSTALLATION
STEP 2 –Mounting the Charging Unit

INSTALLATION
14
INSTALLATION
STEP 2 –Mounting the Charging Unit

15
INSTALLATION
STEP 2 –Mounting the Charging Unit

INSTALLATION
16
INSTALLATION
STEP 2 –Mounting the Charging Unit

INSTALLATION
17
INSTALLATION
STEP 3 –Connecting Charging Unit to NEMA 6-50 Outlet

INSTALLATION
18
(OPTIONAL) INSTALLATION STEP 3 –Hardwire Connection

INSTALLATION
19
INSTALLATION
STEP 4 –Mounting the Holster

INSTALLATION
20
INSTALLATION
STEP 4 –Mounting the Holster
Table of contents
Other EVoCharge Batteries Charger manuals
Popular Batteries Charger manuals by other brands

Enelion
Enelion Vertica installation manual

Holaday Industries
Holaday Industries 491198-48 Series user manual

Würth
Würth BLG 12V-35A Translation of the original operating instructions

Belkin
Belkin BU3DC001-12V user manual

Skil
Skil CR1 3128 Series Original instructions

Jenelec
Jenelec UniCharge 50 Safety instructions