IMPORTANT SAFEGUARDS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
When using electrical equipment, basic safety precautions should always be followed including the following:
• DISCONNECT AC POWER SUPPLY BEFORE SERVICING.
• Installation and servicing of this equipment should be performed by qualified service personnel only.
• Ensure that the electrical wiring conforms to the National Electrical Code NEC® and local regulations
if applicable.
• Do not mount near gas or electrical heaters.
• Do not use outdoors.
• Equipment should be mounted in locations and at heights where it will not be readily subjected to tampering
by unauthorized personnel.
• The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
• Any modification or use of non-original components will void the warranty and product liability.
• Do not use this equipment for other than intended use.
• Allow battery to charge for 24 hours before first use.
• For use with metal enclosed wiring systems.
SAVE THESE INSTRUCTIONS!
Technical Support ■ (623) 580-8943 ■ [email protected]
WPX Series
Installation Instructions
XXXXXXXX REV 1 - 07/23 1
800-533-3948 www.barronltg.com
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
WPX Series
Installation Instructions
XXXXXXXX REV 1 - 07/23 2
800-533-3948 www.barronltg.com
Wall Mount Installation (Fig. 2)
1. Open front cover by screwdriver. (Fig. 1)
2. Knockout center and appropriate mounting screw holes on the back
plate, paste gasket on back of back plate.
3. Feed building power supply wires through the center hole, fix back
plate to waterproof type junction box by screws.
4. Make correct electrical connections inside of fixture according to
wiring diagram. (Fig. 6)
5. Push excess wire into junction box.
6. Attach battery connector to PC board.
7. Snap chevron to EXIT panel if required, restore front panel on unit.
Side Mount (Fig. 3) or Ceiling Mount (Fig. 4) Installation
1. Attach crossbar to junction box, set the crossbar so that the longer
blade is touching the waterproof type junction box.
2. Open front cover by screwdriver. (Fig. 1)
3. If double face is desired, replace back plate with additional face
plate provided.
4. Knockout the mounting hole on top or side of the unit, assemble the
canopy on the unit. (Fig. 5)
5. Route the proper wires through mounting hole out of housing.
6. Make electrical connections inside the J-Box according to wiring
diagram (Fig. 6)
7. Fasten crossbar on J-Box by screws provided.
8. Paste gasket on canopy, then fasten canopy to crossbar and against
the wall.
9. Snap chevron to EXIT panel if required.
10. Attach battery connector to PC board, restore front panel on unit.
Fig. 6
WPX Series
Installation Instructions
XXXXXXXX REV 1 - 07/23 3
800-533-3948 www.barronltg.com
Wiring Diagram (Fig. 6)
Operation
The battery in this unit may not be fully charged. After electricity is connected to the unit for at least 24 hours, then normal
operation of this unit should take effect. To check, press the “TEST” button. The EXIT sign should stay illuminated by
battery backup and the LED indicator will be turned off. Release the “TEST” button, LED indicator will be turned on.
In accordance with NFPA 101, your emergency lighting system must be tested monthly for a minimum of 30 seconds and
annually for 90 minutes. Refer to your local codes for any additional requirements that may apply.
Testing and Reporting Instructions (-G2 and -G3 models)
1. When AC power is supplied to fixture, the unity will automatically initiate a self-test and self-diagnostic test as follows:
• Verifies battery disconnection, charger board failure at every 5 seconds.
• 1 minute self-testing every month.
• 30 minutes self-testing on every 6 months after installation.
• 90 minutes self-testing on every 12 months after installation.
2. Dual color LED lamp indicator shows the following status:
• Green color: On / Ready
Blinking: Testing
• Red color: (Service Alert)
• Service Alert LED Code (Red color LED lamp indicator)
Note: After solving the fault of emergency equipment, please press test button for 2 seconds then release to
reset. LED indicator will show green.
2. “-G2” and “-G3” models also have a manual test function, press test button as follows:
Press test button once (within 2 seconds)
Press test button twice (within 2 seconds)
30 seconds discharge test
Press test button 3 times (within 2 seconds)
Press test button 4 times (within 2 seconds)
*Press and hold test button for 8 seconds
3 minutes discharge test
30 minutes discharge test
90 minutes discharge test
Fixture will leave network and reset itself
*Note: only applies to “-G3” models. If you have problem to initiate provisioning or if you know
the unit belongs to other Guardian Network
One blink ON/pause (4 seconds)
Two blinks ON/pause (4 seconds)
Battery is not connect
Three blinks ON/pause (4 seconds)
Four blinks ON/pause (4 seconds)
Five blinks ON/pause (4 seconds)
Battery voltage too low
Charger board circuit fault
Transfer function failure
Integral lamp fault
Six blinks ON/pause (4 seconds) Remote head’s emergency lamp fault (option)
Seven blinks ON/pause (4 seconds) LED strip failure (just for EXIT sign)
WPX Series
Installation Instructions
XXXXXXXX REV 1 - 07/23 4
800-533-3948 www.barronltg.com
Networking Operations for “-G3” Models
Model with "-G3" suffix is our world winning design equipped with "wireless testing and reporting" features. Unit that
has "-G3" suffix in its model number is capable of joining Guardian emergency lighting management system. It will be
part of a large testing system to be tested and report result wirelessly.
Once powered up and commissioning allowed, unit will automatically join Guardian network and get provisioned. Upon
the completion of the commissioning,unit will perform testing and report based on set schedules.
For more information about commissioning, configurations and testing, please visit website, https://www.barronltg.com
for details.
Remote Heads Connection Instructions (Option)
1. Remove jump connector from the female connector on
PCBA. (Fig. 7)
2. Attach the remote male connector into the female
connector on PC board.
3. Connect extended remote head wires to the remote
wires using wire nuts. Yellow is positive (+) and the
purple is negative (-). (Fig. 8)
Fig. 7
Fig. 8
Jump connector
Extended remote wire
Remote wire
(provided)
Jump connector
Remote head
connector
Remote head
connector

Other Exitronix Lighting Equipment manuals

Exitronix SLW Series User manual

Exitronix

Exitronix SLW Series User manual

Exitronix 400EX Series User manual

Exitronix

Exitronix 400EX Series User manual

Exitronix S902 Series User manual

Exitronix

Exitronix S902 Series User manual

Exitronix VEX-WPCR Series User manual

Exitronix

Exitronix VEX-WPCR Series User manual

Exitronix EMX Series User manual

Exitronix

Exitronix EMX Series User manual

Exitronix 400 Series User manual

Exitronix

Exitronix 400 Series User manual

Exitronix S900C Series User manual

Exitronix

Exitronix S900C Series User manual

Popular Lighting Equipment manuals by other brands

RICOMAN R123101 installation instructions

RICOMAN

RICOMAN R123101 installation instructions

Chauvet TFX-64CM user manual

Chauvet

Chauvet TFX-64CM user manual

Lumitec Poco quick start guide

Lumitec

Lumitec Poco quick start guide

Wenglor LMDX Series operating instructions

Wenglor

Wenglor LMDX Series operating instructions

Mosaic BWL-0625 operating instructions

Mosaic

Mosaic BWL-0625 operating instructions

thomann STAIRVILLE MH-110 Wash 7x10 LED user manual

thomann

thomann STAIRVILLE MH-110 Wash 7x10 LED user manual

GE 75976 instructions

GE

GE 75976 instructions

Gemmy 11955 instructions

Gemmy

Gemmy 11955 instructions

COMPLED Solutions GmbH HashCropter user manual

COMPLED Solutions GmbH

COMPLED Solutions GmbH HashCropter user manual

Pixapro COB60D quick guide

Pixapro

Pixapro COB60D quick guide

JB Systems Matrix LED Operation manual

JB Systems

JB Systems Matrix LED Operation manual

LIGMAN JET 48 installation manual

LIGMAN

LIGMAN JET 48 installation manual

Beamz 150.572 user manual

Beamz

Beamz 150.572 user manual

THOR RIDGE user guide

THOR

THOR RIDGE user guide

Lithonia Lighting CUC8 installation instructions

Lithonia Lighting

Lithonia Lighting CUC8 installation instructions

Garden Lights 2519064 manual

Garden Lights

Garden Lights 2519064 manual

Robus RSD18CCT3M-01 instruction manual

Robus

Robus RSD18CCT3M-01 instruction manual

Ivela 1462 quick start guide

Ivela

Ivela 1462 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.