IMPORTANT SAFEGUARDS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
When using electrical equipment, basic safety precautions should always be followed including the following:
• DISCONNECT AC POWER SUPPLY BEFORE SERVICING.
• Installation and servicing of this equipment should be performed by qualified service personnel only.
• Ensure that the electrical wiring conforms to the National Electrical Code NEC® and local regulations
if applicable.
• Do not mount near gas or electrical heaters.
• Do not use outdoors.
• Equipment should be mounted in locations and at heights where it will not be readily subjected to tampering
by unauthorized personnel.
• The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
• Any modification or use of non-original components will void the warranty and product liability.
• Do not use this equipment for other than intended use.
• Allow battery to charge for 24 hours before first use.
• For use with metal enclosed wiring systems.
SAVE THESE INSTRUCTIONS!
Technical Support ■ (623) 580-8943 ■ [email protected]
EMX Series
Installation Instructions
XXXXXXXX REV 1 - 07/23 1
800-533-3948 www.barronltg.com
Fig. 1
Fig. 4
Fig. 2
Fig. 3
Mounting screw
Wire nut
PCBA
Battery
J-Box
(not included)
Battery male connector
White NEUTRAL
Black 120-277V/AC
Green Ground
Connect the white wire to neutral.
Connect the black wire to the hot lead.
Connect green wire to the ground.
EMX Series
Installation Instructions
XXXXXXXX REV 1 - 07/23 2
800-533-3948 www.barronltg.com
Wall Mount Installation
1. Remove side screw using screwdriver and open front cover. (Fig. 1)
2. Determine appropriate mounting holes that will be used, and knock
out cable entry hole on the backplate of the housing.
3. Feed building AC supply wires through center hole in back plate.
Mount fixture to the J-Box using the (2) 1” long 8-32 screws. (Fig. 2)
4. Make proper electrical connections, refer to wiring diagram. (Fig. 4)
5. Push excess wire into J-Box.
6. Connect battery connector to PC board. (Fig. 3)
7. Restore faceplate with screws.
8. Adjust the lamp heads direction as needed.
9. Restore AC power, charge indicator will turn on, press test button for
manual test.
Wiring Diagram (Fig. 4)
EMX Series
Installation Instructions
XXXXXXXX REV 1 - 07/23 3
800-533-3948 www.barronltg.com
Operation
The battery in this unit may not be fully charged. After electricity is connected to the unit for at least 24 hours, then normal
operation of this unit should take effect. To check, press the “TEST” button. The EXIT sign should stay illuminated by
battery backup and the LED indicator will be turned off. Release the “TEST” button, LED indicator will be turned on.
In accordance with NFPA 101, your emergency lighting system must be tested monthly for a minimum of 30 seconds and
annually for 90 minutes. Refer to your local codes for any additional requirements that may apply.
Testing and Reporting Instructions (-G2 and -G3 models)
1. When AC power is supplied to fixture, the unity will automatically initiate a self-test and self-diagnostic test as follows:
• Verifies battery disconnection, charger board failure at every 5 seconds.
• 1 minute self-testing every month.
• 30 minutes self-testing on every 6 months after installation.
• 90 minutes self-testing on every 12 months after installation.
2. Dual color LED lamp indicator shows the following status:
• Green color: On / Ready
Blinking: Testing
• Red color: (Service Alert)
• Service Alert LED Code (Red color LED lamp indicator)
Note: After solving the fault of emergency equipment, please press test button for 2 seconds then release to
reset. LED indicator will show green.
2. “-G2” and “-G3” models also have a manual test function, press test button as follows:
Press test button once (within 2 seconds)
Press test button twice (within 2 seconds)
30 seconds discharge test
Press test button 3 times (within 2 seconds)
Press test button 4 times (within 2 seconds)
*Press and hold test button for 8 seconds
3 minutes discharge test
30 minutes discharge test
90 minutes discharge test
Fixture will leave network and reset itself
*Note: only applies to “-G3” models. If you have problem to initiate provisioning or if you know
the unit belongs to other Guardian Network
One blink ON/pause (4 seconds)
Two blinks ON/pause (4 seconds)
Battery is not connect
Three blinks ON/pause (4 seconds)
Four blinks ON/pause (4 seconds)
Five blinks ON/pause (4 seconds)
Battery voltage too low
Charger board circuit fault
Transfer function failure
Integral lamp fault (option)
Six blinks ON/pause (4 seconds) Remote head’s emergency lamp fault (option)
Seven blinks ON/pause (4 seconds) LED strip failure (just for exit sign) (option)
EMX Series
Installation Instructions
XXXXXXXX REV 1 - 07/23 4
800-533-3948 www.barronltg.com
Networking Operations for “-G3” Models
Model with "-G3" suffix is our world winning design equipped with "wireless testing and reporting" features. Unit that
has "-G3" suffix in its model number is capable of joining Guardian emergency lighting management system. It will be
part of a large testing system to be tested and report result wirelessly.
Once powered up and commissioning allowed, unit will automatically join Guardian network and get provisioned. Upon
the completion of the commissioning,unit will perform testing and report based on set schedules.
For more information about commissioning, configurations and testing, please visit website, https://www.barronltg.com
for details.
Remote Heads Connection Instructions (Option)
1. Remove ground male connector from the female
connector on PCBA. (Fig. 5)
2. Plug the remote male connector into the female
connector. (Fig. 6)
3. Connect extended remote head wires to the remote
wires using wire nuts. Yellow is positive (+) and the
purple is negative (-). (Fig. 6)
Fig. 11
Fig. 12
Jump connector
Extended remote wire
Remote wire
(provided)
Jump connector
Remote head
connector
Remote head
connector

Other Exitronix Lighting Equipment manuals

Exitronix S902 Series User manual

Exitronix

Exitronix S902 Series User manual

Exitronix SLW Series User manual

Exitronix

Exitronix SLW Series User manual

Exitronix 400EX Series User manual

Exitronix

Exitronix 400EX Series User manual

Exitronix S900C Series User manual

Exitronix

Exitronix S900C Series User manual

Exitronix WPX Series User manual

Exitronix

Exitronix WPX Series User manual

Exitronix VEX-WPCR Series User manual

Exitronix

Exitronix VEX-WPCR Series User manual

Exitronix 400 Series User manual

Exitronix

Exitronix 400 Series User manual

Popular Lighting Equipment manuals by other brands

Tekky MOURNING GORY Installation and operating instructions

Tekky

Tekky MOURNING GORY Installation and operating instructions

Beamz BBP93 user manual

Beamz

Beamz BBP93 user manual

Lumena Pro Solar Secursol user manual

Lumena

Lumena Pro Solar Secursol user manual

Verbatim 52278 instruction manual

Verbatim

Verbatim 52278 instruction manual

Goldair GHL425W operating instructions

Goldair

Goldair GHL425W operating instructions

Vision & Control LDLF60x240-IR850/UDC Instructions for use

Vision & Control

Vision & Control LDLF60x240-IR850/UDC Instructions for use

INNLED T4 user manual

INNLED

INNLED T4 user manual

Domus MURO-26S-B-W installation manual

Domus

Domus MURO-26S-B-W installation manual

Viabizzuno net 48 muro Installing instructions

Viabizzuno

Viabizzuno net 48 muro Installing instructions

Daintree GE current Tetra Contour installation guide

Daintree

Daintree GE current Tetra Contour installation guide

Laserworld GREEN-10000 user manual

Laserworld

Laserworld GREEN-10000 user manual

Eterna YD630M Safety and installation instructions

Eterna

Eterna YD630M Safety and installation instructions

Promitto M-FLEX 750LM 3000K user manual

Promitto

Promitto M-FLEX 750LM 3000K user manual

kenall LUXTRAN LTSIU Series installation instructions

kenall

kenall LUXTRAN LTSIU Series installation instructions

Pahlen 125820 user manual

Pahlen

Pahlen 125820 user manual

Flash 8R BEAM user manual

Flash

Flash 8R BEAM user manual

Mighty Bright WonderFlex user manual

Mighty Bright

Mighty Bright WonderFlex user manual

LUG LUGCLASSIC SLIM LB LED Installation instruction

LUG

LUG LUGCLASSIC SLIM LB LED Installation instruction

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.