Exor eX710 User manual

Exor International S.p.A.
MANUGENEX7xx
Ver. 2.00
eX700 Series
Operating Instructions
Basic User’s Manual for eX700 Series
Touchscreen Products

2
MANUGENEX7xx
Operating Instructions
VER 2.00
Copyright © 2017 Exor International S.p.A. – Verona, Italy
Subject to change without notice
The information contained in this document is provided for informational purposes only. While eorts
were made to verify the accuracy of the information contained in this documentation, it is provided “as
is” without warranty of any kind.
Third-party brands and names are the property of their respective owners.
www.exorint.net

3
MANUGENEX7xx
Operating Instructions
VER 2.00
Table of Contents
Table of Contents
Introduction 4
Safety Guide 5
1Product Overview 6
2Standards and Approvals 7
3 Technical Specications 9
4Technical Data 11
4.1 Dimensions 14
4.2 Installation Environment 16
4.3 Safety instruction 17
4.4 Installation Procedure 17
5Connections 18
5.1 Serial Port 20
5.2 Ethernet Port 20
5.3 Optional plugin module 21
6Power Supply, Grounding and Shielding 23
7Battery 24
8Special Instruction for Use 25
9Getting Started 25
10 System Settings 26
11 Unpacking and Packing Instructions 28

4
MANUGENEX7xx
Operating Instructions
VER 2.00
Introduction
The operational guidelines described below is information which relates to the device, installation, tran-
sportation, storage, assembly, use and maintenance.
This Operating Instruction describes the main features of the Exor operator panels. The Manual refers
to the following models:
eX705 Operator interface with TFT color 5” widescreen display multitouch projected capacitive
touchscreen
eX707 Operator interface with TFT color 7” widescreen display multitouch projected capacitive
touchscreen
eX710 Operator interface with TFT color 10.1” widescreen display multitouch projected capacitive
touchscreen
eX715 Operator interface with TFT color 15.6” widescreen display multitouch projected capacitive
touchscreen
eX721 Operator interface with TFT color 21.5” widescreen display multitouch projected capacitive
touchscreen
Introduction

5
MANUGENEX7xx
Operating Instructions
VER 2.00
Safety Guide
The manual contains safety standards that must be respected for the personal safety and to avoid damage.
Indications of attention are divided into three levels of severity:
DANGER: indicates a failure to observe safety rules and such failure may cause death or serious injuries.
ATTENTION: indicates a failure to observe safety rules and that deciency may cause damage.
CAUTION: indicates a failure to observe safety rules and that deciency may cause defects to the
equipment or inconsistencies.
CAUTION
ATTENTION
DANGER
!
!
Safety Guide

6
MANUGENEX7xx
Operating Instructions
VER 2.00
1 Product Overview
eX Series 700 HMI products combine state-of-the-art connectivity features and top performance in a
great design. Products have been designed as IoT edge devices with the combination of a powerful
controller with networking capability (up to 3 Ethernet networks) and outstanding communication
options including client/server OPC UA. They are the ideal choice for all demanding IoT edge
applications in factory, marine and building automation.
The glass projected capacitive touchscreen and the brilliant displays with size up to 21.5” and
resolution up to 1920x1080 guarantee great optical performance; with the support of multitouch
gesture programming they can create the most natural human interfaces.
• eX Series 700 products have been designed to run the JMobile software for powerful HMI
applications.
• Gateway function with OPC UA Server and Client.
• Secure connectivity with JMcloud and full network separation.
• Powerful browser wih industry standard Web engines.
• Optional CODESYS V3 PLC runtime with choice of major I/O protocols.
• Optional plug-in modules for eldbus systems, I/O and controllers.
Product Overview

7
MANUGENEX7xx
Operating Instructions
VER 2.00
2 Standards and Approvals
The products have been designed for use in an industrial environment in compliance with the 2014/30/
EU EMC Directive.
The products have been designed in compliance with:
EN 61000-6-4 CISPR 22 Class A
CISPR 16-2-3
EN 61000-6-2 EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
EN 61000-4-29
EN60945
The installation of these devices into the residential, commercial and light-industrial environments is allo-
wed only in the case that special in measures are taken in order to ensure conformity to EN 61000-6-3.
The products are in compliance with the Restrictions on Certain Hazardous Substances (RoHS) Directive
2002/95/EC
In compliance with the above regulations the products are CE marked.
Standards and Approvals

8
MANUGENEX7xx
Operating Instructions
VER 2.00
Standards and Approvals
Product Identication
The product may be identied through a plate attached to the rear cover. You will have to know the type of
unit you are using for correct usage of the information contained in the guide.
An example of this plate is shown in the gure below:
Note: the eX710 label is used as an example for eX700 Series
product model name eX710
product part number EX710U5P1
year/week of production 1706
serial number AA00011FV000000561AA
version id of the product 120201A01000000
manufacturer address Exor International S.p.A.
Via Monte Fiorino 9
IT-37057 San Giovanni Lupatoto (VR)

9
MANUGENEX7xx
Operating Instructions
VER 2.00
Standards and Approvals
Electromagnetic Compatibility (EMC)
Radiated disturbance test Class A CISPR 22
CISPR 16-2-3
Electrostatic discharge immunity test 8 kV (air electrostatic discharge) EN 61000-4-2
4 kV (contact electrostatic discharge)
Radiated, radio-frequency, 80 MHz ÷ 1 GHz, 10V/m EN 61000-4-3
electromagnetic eld immunity test 1,4 GHz ÷ 2 GHz, 3 V/m
2 GHz ÷ 2.7 GHz, 1 V/m
Burst immunity test ± 2 KV dc power port EN 61000-4-4
± 1 KV signal line
Surge immunity test ± 0,5 KV dc power port (line to earth) EN 61000-4-5
± 0,5 KV dc power port (line to line)
± 1 KV signal line (line to earth)
Immunity to conducted disturbances
inducted by radiofrequency eld 0.15 ÷ 80 MHz, 10V EN 61000-4-6
Power frequency magnetic eld
immunity test Enclosure, 50/60Hz, 30A/m EN 61000-4-8
Environmental conditions
Operating temperature (surrounding -20 ÷ +60°C (vertical installation) EN 60068-2-14
air temperature) Plug-in modules and USB devices
may limit max temperature to +50°C
Storage temperature -20 ÷ +70°C EN 60068-2-1
EN 60068-2-2
EN 60068-2-14
Operating and storage humidity 5 ÷ 85 % RH not-condensing EN 60068-2-30
Vibrations 5 ÷ 9 Hz, 7 mm p-p EN 60068-2-6
9 ÷ 150 Hz, 1 g
Shock ± 50 g, 11 ms, 3 pulses per axis EN 60068-2-27
Protection class Front panel IP66, Rear IP20 EN 60529
3 Technical Specications
Touchscreen technology Projected capacitive
Back-up battery 3V 50mAh Lithium, rechargeable, not user-replaceable,
model VL2330.
Fuse Automatic
Serial Port RS-232, RS-485, RS-422 software congurable
Flash 4GB for eX705, eX707, eX710, 8GB for eX715, eX721
RAM 512MB for eX705, 1GB for eX707, eX710, 2GB for
eX715, eX721
Hardware clock Clock/Calendar with back-up battery
Accuracy RTC (at 25°C) <100ppm

10
MANUGENEX7xx
Operating Instructions
VER 2.00
Voltage dips, short interruptions and
voltage variations immunity test Port: AC mains; Level:
0% duration: 1 cycle and 250 cycles (50Hz);
1 cycle and 300 cycles (60Hz);
40% duration: 10 cycles (50Hz);
12 cycles (60Hz);
70% duration: 25 cycles (50Hz);
30 cycles (60Hz);
Phase: 0°-180°
Test executed on the 230Vac side of the Exor International S.p.A. Power Supply EN 61000-4-11
Port: DC mains; Level:
0% duration: 10ms 20 spaces by 1s
Test executed on the 24Vdc of the EUT EN 61000-4-29
Durability information
Backlight service life 40000 Hrs. or more
(LED type) (Time of continuos operation until the brightness of the
backlight reaches 50% of the rated value when the
sorrounding air temperature is 25°C) - see Note 1
Note 1: Extended use in environments where the surrounding air temperature is 40°C or higher may
degrade backlight quality/reliability/durability.

11
MANUGENEX7xx
Operating Instructions
VER 2.00
4 Technical Data
Technical Data
Model eX705 eX707
Display / Backlight TFT Color / LED TFT Color / LED
Colors 64K 16M
Resolution 800X480 800X480
Diagonal (inches) 5” widescreen 7” widescreen
Dimming yes yes
Flash 4GB 4GB
SD card slot yes yes
RAM 512MB 1GB
Serial Port RS-232,RS-485, RS-422
software congurable
RS-232,RS-485, RS-422
software congurable
Ethernet port 2 10/100Mb 2 10/100Mb, 1 10/100/1000Mb
USB port 1 Host interface version 2.0
max. 500mA
2 Host interface version 2.0
max. 500mA
Expansion slot 1 Optional Plugin 2 Optional Plugin
Battery rechargeable rechargeable
Real Time Clock yes yes
Voltage 24Vdc (*) 24Vdc (*)
Current rating (at 24VDC) 0.6A 0.7A
Weight 1 Kg 1.3 Kg
(*) 10-32Vdc
For applications requiring compliance with EN 61131-2 and specically in reference to 10 ms voltage dips, the
power supply range voltage is 18-32Vdc.

12
MANUGENEX7xx
Operating Instructions
VER 2.00
Technical Data
Model eX710 eX715
Display / Backlight TFT Color / LED TFT Color / LED
Colors 16M 16M
Resolution 1280X800 1366X768
Diagonal (inches) 10.1” widescreen 15.6” widescreen
Dimming yes yes
Flash 4GB 8GB
SD card slot yes yes
RAM 1GB 2GB
Serial Port RS-232,RS-485, RS-422
software congurable
RS-232,RS-485, RS-422
software congurable
Ethernet port 2 10/100Mb, 1 10/100/1000Mb 2 10/100Mb, 1 10/100/1000Mb
USB port 2 Host interface version 2.0
max. 500mA
2 Host interface version 2.0
max. 500mA
Expansion slot 2 Optional Plugin 2 Optional Plugin
Battery rechargeable rechargeable
Real Time Clock yes yes
Voltage 24Vdc (*) 24Vdc (*)
Current rating (at 24VDC) 1.00A 1.20A
Weight 1.7 Kg 4.1 Kg
(*) 10-32Vdc
For applications requiring compliance with EN 61131-2 and specically in reference to 10 ms voltage dips, the
power supply range voltage is 18-32Vdc.

13
MANUGENEX7xx
Operating Instructions
VER 2.00
Model eX721
Display / Backlight TFT Color / LED
Colors 16M
Resolution 1920X1080
Diagonal (inches) 21.5” widescreen
Dimming yes
Flash 8GB
SD card slot yes
RAM 2GB
Serial Port RS-232,RS-485, RS-422
software congurable
Ethernet port 2 10/100Mb with integrated
switch, 1 10/100/1000Mb
USB port 2 Host interface version 2.0
max. 500mA
Expansion slot 2 Optional Plugin
Battery rechargeable
Real Time Clock yes
Voltage 24Vdc (*)
Current rating (at 24VDC) 1.70A
Weight 6.1 Kg
(*) 10-32Vdc
For applications requiring compliance with EN 61131-2 and specically in reference to 10 ms voltage dips, the
power supply range voltage is 18-32Vdc.
Technical Data

14
MANUGENEX7xx
Operating Instructions
VER 2.00
4.1 Dimensions
Technical Data
Cut out
MODEL A B C D E F
eX705 147mm/5.78” 107mm/4.21” 136mm/5.35” 96mm/3.78” 56mm/2.40” 8mm/0.31”

15
MANUGENEX7xx
Operating Instructions
VER 2.00
Technical Data
Cut out
MODEL A B C D E F
eX707 187mm/7.36” 147mm/5.79” 176mm/6.90” 136mm/5.35” 47mm/1.85” 8mm/0.31”
eX710 282mm/11.10” 197mm/7.80” 271mm/10.67” 186mm/7.32” 56mm/2.20” 8mm/0.31”
eX715 422mm/16.60” 267mm/10.50” 411mm/16.18” 256mm/10.00” 56mm/2.20” 8mm/0.31”
eX721 552mm/21.73” 347mm/13.66” 541mm/21.30” 336mm/13.22” 56mm/2.20” 8mm/0.31”

16
MANUGENEX7xx
Operating Instructions
VER 2.00
4.2 Installation Environment
Avoid prolonged exposition to direct sunlight to avoid the risk of overheating the device.
The equipment is not intended for installation in contact with corrosive chemical compounds. Check the
resistance of the front panel to a specic compound before installation.
Do not use tools of any kind (screwdrivers, etc.) to operate the touch screen of the panel.
In order to meet the front panel protection classications, proper installation procedure must be followed:
• the borders of the cutout must be at
• screw up each xing screw until the bezel corner get in contact with the panel.
•the cutout for the panel must be of the dimensions indicated in this manual.
The IP66 is guaranteed only if:
• max deviation from the plane surface to the cut-out: O0.5mm
•thickness of the case where is mounted the equipment: from 1,5mm to 6mm
•max surface roughness where the gasket is applied: O120 um
A. eX7xx
B. Installation cut-out
Technical Data

17
MANUGENEX7xx
Operating Instructions
VER 2.00
4.4 Installation Procedure
Place the xing brackets contained in the xing kit as shown in gure
Technical Data
4.3 Safety instruction
For all installation notes, please refer to the Installation Guide provided with the product.
!
CAUTION
Tightening torque: 130Ncm or screw each xing screw until the bezel corner gets in contact with
the panel.

18
MANUGENEX7xx
Operating Instructions
VER 2.00
5 Connections
1. USB Port
2. Power Supply
3. Serial port
4. Ethernet Port 0 (10/100Mb)
5. Ethernet Port 1 (10/100Mb)
6. Expansion slot for Plugin module
7. SD Card Slot
Fig. 5.1
Connections
eX705

19
MANUGENEX7xx
Operating Instructions
VER 2.00
1. USB port
2. Ethernet port 2 (10/100Mb)
3. Ethernet port 1 (10/100Mb)
4. Serial Port
5. Ethernet port 0 (10/100/1000Mb)
6. Power Supply
7. 2x Expansion slot for Plugin module
8. SD Card Slot
Fig. 5.2
Connections
eX707, eX710, eX715, eX721

20
MANUGENEX7xx
Operating Instructions
VER 2.00
5.1 Serial Port
The serial port is used to communicate with the PLC or with another type of controller.
Dierent electrical standards are available for the signals in the PLC port connector: RS-232, RS-422,
RS-485.
The serial port is software programmable. Make sure you select the appropriate interface in the pro-
gramming software.
The communication cable must be chosen for the type of device being connected.
Connections
SERIAL PORT
To operate in RS-485 pins
1-2 and 3-4 must be con-
nected externally.
Pin Description
1 CHB-
2 CHA-
3 CHB+
4 CHA+
5 +5V output
6 GND
7
8 SHIELD
5.2 Ethernet Port
1 8
Yellow
OFF: Valid link has NOT been detected
ON: Valid link has been detected
Green
ON: No activity
BLINKING: Activity
The Ethernet port have two status indicators. Please see description in gure.
Pin Description
1 RX
2 TX
3 CTS
4RTS
5 +5V output
6 GND
7
8 SHIELD
RS-232 RS-422, RS-485
This manual suits for next models
4
Table of contents
Other Exor Touch Panel manuals