EZ-Boom™2010 Automated Application
Control System Quick Reference Card
www.EZ-Boom.com
STEP 2. BOOM SETUP
1. From the configuration menu, select EZ-Boom / Boom. The Boom Setup
screen appears.
2. Press the uand Dkeys to set the Swath Width spacing and Boom
Width (coverage width) and then press o. To create overlap, use a swath
width that is narrower than the boom width.
3. Enable any fence nozzles. Fence nozzles are at the far ends of the boom
and point out to the sides to cover any fence lines. Switch 1 controls the
left fence nozzle, and the first switch after the boom section switches controls the right nozzle. With two
fence nozzles, the system supports up to eight boom sections. Fence nozzles are always manually
controlled. They must be activated with the corresponding switch.
4. Press the uand Dkeys to set the Number of Sections value and then
press o. This is the number of sections in the boom. The section widths
will automatically adjust to a default that is calculated by dividing the
Swath Width value by the Number of Sections value.
5. Press uor Dto adjust the section width values and then press o. As
you adjust each section width, the later section widths are adjusted so the
specified Boom Width is maintained.
6. Select Exit and then press o.
STEP 3. SET THE ANTENNA/IMPL OFFSET
1. From the configuration menu, select EZ-Boom/Ant/Impl Offset. The antenna/impl offset screen appears.
2. Press uor Dto adjust the distance the antenna is from the spray boom. You can set the antenna to
ahead of, or behind, the implement.
3. Select Exit and then press o.
STEP 4. AUTOMATIC BOOM SWITCHING SETUP
1. From the configuration menu, select EZ-Boom / Swath Control. The
Swath Control screen appears.
2. Set the Boom Control option to Auto or Manual switching and then press
o.
3. Set the Lead In time and then press o. This is the number of seconds
before leaving a sprayed area and entering an unsprayed area that the
boom sections will turn on.
4. Set the Off Delay time and then press o.This represents the amount of time before or after you enter a
previously sprayed area that you want the boom sections to turn off. For example, if you want the boom
sections to turn off 1 second before you cross into a headland, set the Off Delay time to -1.0 seconds.
5. Select either Minimize Skip or Minimize Overlap.
6. Select Exit and then press o.