FältCom ECII SE Specification sheet

Manual FältCom ECII SE Eng Page 1 of 36
Version: 5.2
Updated: 2006-10-25
FältCom ECII SE
Manual and installation instructions

Manual FältCom ECII SE Eng Page 2 of 36
1 Table of contents
1TABLE OF CONTENTS................................................................................................... 2
2NOTES.............................................................................................................................. 4
3COPYRIGHT..................................................................................................................... 4
3.1 Description of goods................................................................................................. 4
3.2 Warranty................................................................................................................... 4
3.3 Updates.................................................................................................................... 5
3.4 Repair return procedure........................................................................................... 5
3.4.1 Service form......................................................................................................... 6
4GENERAL.........................................................................................................................6
4.1 Contents of packing.................................................................................................. 6
4.1.1 System components ............................................................................................ 6
5INTRODUCTION .............................................................................................................. 6
5.1 Foreword.................................................................................................................. 6
5.2 Product description................................................................................................... 6
5.2.1 Design and function............................................................................................. 6
5.2.2 Multiple lift phone connection .............................................................................. 6
5.2.3 Programming and testing..................................................................................... 6
6INSTALLATION INSTRUCTIONS ................................................................................... 6
6.1 Recessed mounting.................................................................................................. 6
6.2 Frame mounting....................................................................................................... 6
6.3 Mounting behind the car operating panel................................................................. 6
6.4 Connection to alarm button...................................................................................... 6
6.4.1 Closing alarm button function .............................................................................. 6
6.4.2 Separate alarm button(s)..................................................................................... 6
6.5 Connection to telephone line.................................................................................... 6
6.5.1 Connection to telephone exchange and other devices........................................ 6
6.5.2 Connection with separate suspension cable ....................................................... 6
6.5.3 Flat cable ............................................................................................................. 6
6.5.4 Connection via existing cable .............................................................................. 6
6.6 Connection of voltage feed ...................................................................................... 6
6.7 Connection to loop amplifier..................................................................................... 6
6.8 Connection of external pictogram ............................................................................ 6
7PROGRAMMING.............................................................................................................. 6
7.1 Standard functions ................................................................................................... 6
7.1.1 Activation of programming mode......................................................................... 6
7.1.2 Reset of all settings.............................................................................................. 6
7.1.3 Input of alarm numbers........................................................................................ 6
7.1.4 Closing alarm button function .............................................................................. 6
7.1.5 Test alarm to test the installation......................................................................... 6
7.2 More available functions .......................................................................................... 6
7.2.1 Change of time delay for alarm button................................................................. 6
7.2.2 Connection via telephone exchange.................................................................... 6
7.2.3 Activation of automatic test alarm........................................................................ 6
7.2.4 Answering function............................................................................................... 6
7.2.5 Alarm mode.......................................................................................................... 6

Manual FältCom ECII SE Eng Page 3 of 36
7.2.6 Busy line function................................................................................................. 6
7.2.7 Battery alarm receiver.......................................................................................... 6
7.2.8 Simplified acknowledge ....................................................................................... 6
7.2.9 Disconnection of acknowledgement.................................................................... 6
7.2.10 Change of alarm flashing sequence................................................................ 6
7.2.11 Programmable alarm type............................................................................... 6
7.2.12 Unit ID.............................................................................................................. 6
7.2.13 Info alarm......................................................................................................... 6
7.2.14 End-of-alarm.................................................................................................... 6
7.2.15 P100 alarm protocol ........................................................................................ 6
7.2.16 Dial tone detection........................................................................................... 6
8ALARM RECEIVING ........................................................................................................ 6
8.1 Alarm call.................................................................................................................. 6
8.1.1 Acknowledging an alarm...................................................................................... 6
8.1.2 Speech exchange................................................................................................ 6
8.1.3 Termination of active alarm mode ....................................................................... 6
8.1.4 Forwarding a call.................................................................................................. 6
8.2 Calls to a lift phone................................................................................................... 6
9TROUBLESHOOTING ..................................................................................................... 6
9.1 Lift phone cannot be programmed........................................................................... 6
9.2 Lift phone unable to call up ...................................................................................... 6
9.3 Lift phone calls up automatically at power on.......................................................... 6
9.4 Whistling sound from loudspeaker (at alarm sequence).......................................... 6
9.5 Disturbance during voice communication ................................................................ 6
9.6 Technical support..................................................................................................... 6
10 TECHNICAL DATA .......................................................................................................... 6
11 PROGRAMMING KEY MAP ............................................................................................ 6
12 CONTACT INFORMATION.............................................................................................. 6

Manual FältCom ECII SE Eng Page 4 of 36
2 Notes
We would like to thank you for placing your confidence in Fält Communications AB and are
convinced about the choice of one of our security products will fulfill your expectations. In
order to operate this FältCom ECII SE correctly we would ask you to read this manual
carefully.
3 Copyright
This document belongs to Fält Communications AB, and may only be reproduced, adapted or
transcribed after written permission from copyright proprietor. Copyright © 2005
3.1 Description of goods
Hereby Fält Communications certifies that this product is in compliance with essential
requirements and with other relevant regulations that is evident of directive 1999/5/EG and
the following standards:
Emission EN50801-1
EN12015
Immunity EN50082-1
EN120016
Telecom TBR21
The equipment has been approved in accordance with Council Decision 98/482/EC (CTR 21)
for pan-European single terminal connection to the public switched telephone network
(PSTN). However, due to differences between the individual PSTN provided in different
countries, the approval does not, in itself, give unconditional assurance of successful
operation on every PSTN network termination point. In the event of problems, please contact
your equipment supplier.
It also complies with requirements according to EN81:1-2, EN81:28 & EN81:70.
Umeå, August 2005
Rolf Sandberg
CEO, Fält Communications AB
3.2 Warranty
There is a 1-year warranty (12 months) for manufacturing failure or material failure
commencing with the delivery date.

Manual FältCom ECII SE Eng Page 5 of 36
Warranty does not include:
- Incorrect or careless usage
- Damages caused by thunderstorms or air pollution.
- Vandalism or damage.
- Normal wear
Fält Communications AB reserves the right to determine if the product will be repaired or
replaced. Warranty ceases to be valid if defects occur due to incorrect use, or other method of
application, or context that has been specified in this manual.
3.3 Updates
Visit our web site to get access to the latest updates for market information and technical
documentation. Following information can be found:
- Product surveys
- Market material
- Updated user manual
- Software and available updates
- Installation and maintenance instructions
- Contact information
www.faltcom.com
3.4 Repair return procedure
Fält Communications AB only accepts returns, which are accompanied by a completed
Service Card, which can be found in the section Service form. This form can also be
downloaded from our web site. If the product is purchased from one of our distributors the
buyer must first contact the distributors for assistance.
All returns must be sent well packed with freight paid to the address:
Fält Communications AB
c/o BL Elektronik AB
Furuhedsvägen 1
SE-952 31 KALIX, Sweden
Repaired products are sent to customers as a regular post parcel with freight paid on the
assumption that the product is included by warranty. If the investigation shows that there are
no defects on the returned product the customer is charged with a service fee and freight
charge. The customer can ask for a quotation for repair of product not covered by warranty.

Manual FältCom ECII SE Eng Page 6 of 36
3.4.1 Service form

Manual FältCom ECII SE Eng Page 7 of 36

Manual FältCom ECII SE Eng Page 8 of 36
4 General
4.1 Contents of packing
Packing for FältCom ECII SE contains following parts:
Art No. 2160 - FältCom ECII SE Complete, includes:
- Art No. 2156 FältCom ECII SE
- Art No. 2138 Mounting frame
- Art No. 2019 Mounting Kit ECII
- Art No. 2022 ECII Sticker
- Art No. 2014 SE Programming Guide
Art No 2161 - FältCom ECII SE COP Complete, for mounting behind the car operating panel
includes:
- Art No. 2157 FältCom ECII SE COP
- Art No. 2032 Mounting Kit Behind COP
- Art No. 2022 ECII Sticker
- Art No. 2014 SE Programming Guide
Art No 2163 - FältCom ECII SE ALBU Complete, with integrated alarm button includes:
- Art No. 2159 FältCom ECII SE ALBU
- Art No. 2171 Mounting frame
- Art No. 2019 Mounting Kit ECII
- Art No. 2022 ECII Sticker
- Art No. 2014 SE Programming Guide
4.1.1 System components
There are a large variety of available system components that can be ordered separately from
Fält Communications AB or from our distributors.
For more information about them, please visit our web site www.faltcom.com
5 Introduction
5.1 Foreword
We recommend a carefully reading of this user manual before FältCom ECII SE is put into
operation, to ensure that the product is used safely and effectively.
FältCom ECII SE should only be used in the context for which it is intended. All other form of
usage will be considered as being solely the users own risk. Only qualified persons are
permitted to install, program and start-up this product. Start-up is only allowed after the
product has been properly installed. As a consequence Fält Communications AB disclaims all

Manual FältCom ECII SE Eng Page 9 of 36
responsibility for possible defects, operational disturbance, accidents etc. caused by lack of
knowledge or carelessness from the user. The same principle is valid for all not approved
changes to the product.
Fält Communications AB reserves the right to make changes in the product for functional or
commercial reasons. The company is not forced to immediately update reference manuals.
5.2 Product description
The FältCom ECII SE is alarm equipment for the PSTN network with built in duplex speech
communication designed for installation in lifts.
The FältCom ECII SE is a dialing alarm transmission unit with built-in voice communication
function, intended for installation in passenger lifts. When a lift passenger presses the button
for alarm/emergency signal, the lift phone automatically calls up an alarm centre or some
other predefined alarm receiver and indicates where the alarm comes from. At the same time,
voice communication is established and the person in distress can talk to the staff at the
alarm centre, from where help will be dispatched.
5.2.1 Design and function
The user only sees the lift phone as a discreetly designed panel with perforated screen plate
for the loudspeaker and microphone. The lift phone is activated with the standard alarm
button in the lift or, if required, with a separate alarm button. When someone presses the
alarm button for more than 4 seconds, the alarm calling process is activated in the lift phone.
This time delay can easily be programmed to between 2 and 30 seconds.
The lift phone design also facilitates mounting. Loudspeaker, microphone, all the electronics,
the keys for programming and testing, as well as all connection points are integrated in one
single unit. This means quick and easy installation as well high reliability in operation. The lift
phone speaker sound is easily adjusted with a hidden trim pot.
Lift phone FältCom ECII SE

Manual FältCom ECII SE Eng Page 10 of 36
On the lift phone’s front plate, there are two pictograms and two single colored LED (yellow
and green), which is normally off. The left LED becomes yellow when an alarm call is in
progress and the right LED becomes green when the alarm has been received by an alarm
centre and a speech connection is established. The green LED is also used to indicate
programming mode. The LED can be programmed to other light sequences, see section
Programming for more information. Note that with a separate device, external pictograms can
be activated, se section Connection of external pictogram.
The lift phone can be mounted recessed in the cage ceiling/wall, or mounted in a frame,
which eliminates the need to make other holes than those for the cables.
Depending on the design of the button & display plate, it may also be possible to install the lift
phone in a prepared space behind the plate. There is a version of the lift phone with a
completely flat panel, specially intended for such mounting. Contact your local distributor for
more information.
The connection of the lift phone requires one cable to the alarm button in the lift and one two-
wire cable to the lift engine room for connection of a standard analogue telephone line. It is
possible to use a separate suspension cable of the type round cable or flat cable. As an
alternative, two unused wires in the existing cage cable can be used. It is very important that
the cable is fastened properly. For the separate suspension cable, there is a special mounting
kit, which includes the necessary mounting parts.
The FältCom ECII SE consumes very little power and can be supplied by the voltage from the
telephone line. Separate power supply is only required if several lift phones are connected to
the same telephone line or if the line voltage is below 32 VDC. See more under section
Technical Data.
100 mm
100 mm
Loudspeaker mesh LED
Microphone hole Keypad
Terminal block
23 mm
Adjustment of sound

Manual FältCom ECII SE Eng Page 11 of 36
5.2.2 Multiple lift phone connection
Several lift phones may be connected to the same telephone line. When one of the lift phones
has established a connection, the other ones will not be able to use the line; a busy tone will
instead be heard in the loudspeaker. When the line becomes free, the alarm call will be
connected automatically.
Installation of two or more FältCom ECII SE on the same telephone line requires a separate
power supply to the lift phones. The lift phone outlet marked DC is then connected to the
existing emergency power supply of the lift via a special DC/DC converter. If no power supply
is available a separate emergency power source with a built-in battery can be used. FältCom
ECII SE can then also send information about the battery status to the alarm central. Both
products are described in the product catalogue.
A total of maximum six lift/emergency phones may be connected on the same subscription.
Ordinary telephones, fax machines, modems or other types of alarm transmitters must not be
connected to the same telephone line as FältCom ECII SE because it might disturb the
functionality.

Manual FältCom ECII SE Eng Page 12 of 36
5.2.3 Programming and testing
On the back of the lift phone, there is a keypad used for programming call numbers, function
selection, and testing. All such settings are made during the installation and, normally, no
subsequent changes are required. It is also possible to remotely program the lift phone with a
special Windows program and a modem. Contact your local distributor for more information.
The FältCom ECII SE is capable of calling 6 alarm receivers or standard telephones with tone
selection.
The lift phone can be programmed to send a test alarm to a specific test alarm receiver with
an interval of 1–9 days. This alarm tests the lift-phone electronics and the telephone line.
The lift phone can also be programmed to answer an incoming call automatically after four
ringing signals. In this case, tones are heard in the receiver when the call is connected.
If an emergency power supply is connected, the lift phone automatically can send an alarm if
the battery is bad and need to be replaced. A special telephone number for the battery alarm
can be programmed.
See Programming section for detailed programming instructions.
6 Installation instructions
Only competent and qualified personnel may install the FältCom ECII SE. Knowledge,
technical skill and correct equipment are required for safe and efficient installation.
Mind your own safety when installing FältCom ECII SE. You must never work in an
open lift shaft without a safety harness. Be extremely careful and break current if
you work close to a voltage of 230-400V, e.g. in the lift engine room. Never
disconnect a cable before you have made sure that it is not connected to any
voltage
Start by selecting a suitable place for the lift phone. Usually, you can find an easily accessible
and yet well protected place in the lift cage ceiling. Avoid installing the phone in a corner or
behind anything that may reflect the sound. Such installation might lead to acoustic feedback
instability between the loudspeaker and the microphone. You must be able to access the
existing suspension cable and the alarm button in the lift. Also, keep in mind that you must be
able to access the back of the lift phone in order to connect cables and program different
functions. Normally, this is easier to do inside of the lift, before the lift phone is screw-
mounted.
Make sure that you will not saw or drill in existing cabling when you make the holes!
6.1 Recessed mounting
1. Select a suitable place according to the instructions above.
2. Drill a hole in the centre of the selected place and then make a hole with a 86-mm
rotary hole saw or drill. See the enclosed drill template.

Manual FältCom ECII SE Eng Page 13 of 36
3. Fasten the lift phone with the 4 enclosed screws. If it will not be possible to access
the lift phone from outside the lift cage, cables must be connected and the lift phone
programmed before it is mounted.
6.2 Frame mounting
1. Mark and pre-bore the holes for the lift phone frame according to the enclosed drill
template. Drill the holes for the cables to the alarm button and telephone connection
according to the drill template.
2. Fasten the frame first and then the lift phone with the enclosed screws, after the
cables have been connected and the lift phone have been programmed.
6.3 Mounting behind the car operating panel
This alternative is only possible if there is
already a prepared space for a lift phone behind
the button & display plate. There is a special
version of the lift phone which is specially
designed for mounting behind a button & display
plate.
Since the design of the display may vary, we are
not able to give exact mounting instructions
here.
Keep in mind that the microphone hole must
be aligned with a hole in the display plate. It
might become necessary to drill a new hole.
For the best sound quality, the distance between
the lift phone front plate and the display plate
should not exceed 1 mm
6.4 Connection to alarm button
1. Draw a two-wire cable (max 10 m) from the lift’s alarm button and screw the wires on
to the lift phone’s terminal block at ”ALARM”.
2. Fasten the cable with cable ties or cable clips on the outside of the lift.
Note that the alarm button in the lift cage is normally double-breaking, i.e. made for two
separate connections, one of them usually connected to a local bell and the other one used

Manual FältCom ECII SE Eng Page 14 of 36
for the lift phone. The connections must be galvanically isolated. If they are not, or if the
existing alarm button only has one connection, the button must be replaced to another type.
Please note that there is a special version of the FältCom ECII SE with an integrated alarm
button which can be used if there is no suitable alarm button available in the lift. That version
has a double breaking alarm button where one part (NC) is used for the lift phone and the
other part (NO) can be used for the alarm bell.
6.4.1 Closing alarm button function
Note that the alarm button may have closing or breaking function. Breaking function is to be
preferred and is the default setting in FältCom ECII SE. If the button has closing function, the
lift phone must be programmed to handle this. See section Programming for more
information.
6.4.2 Separate alarm button(s)
If there is no alarm button in the lift, a separate button must be installed in the cage and
marked accordingly. Note that, in order to avoid misunderstandings, there should never be
two alarm buttons in a lift cage. It is possible to connect extra alarm buttons to the unit, for
instance on top of the lift car where a repair man can be trapped. It is important that all
buttons are of the same type.
6.5 Connection to telephone line
The lift phone must be connected to a standard analogue telephone line. Normally it can also
be connected to an ISDN connection via a terminal adaptor. To minimize disturbances when
more than one FältCom ECII SE is connected to the same telephone line it is recommended
that they are connected in series, not in parallel.
If the lift phone is connected to a standard telephone jack, the jack should be located in the lift
engine room or some other room with no admittance to unauthorized persons. This is
important to make sure that the connection will not be interrupted by mistake.
6.5.1 Connection to telephone exchange and other devices
The FältCom ECII SE can be connected to an extension in a telephone exchange, provided
the connection is analogue. Digital exchanges usually have at least one analogue connection,
since many alarms, faxes and modems require analogue communication. When connecting
to a telephone exchange it must be verified that the exchange also works in case of
power failure. The lift phone has a function, which enables it to dial a zero and then wait two
seconds for the dialing tone before proceeding with the alarm number. See section
Programming for more information.
In some situations the telephone line has a function for Hot-line calling. This means that the
telephone line automatically calls up a pre-programmed number. By programming the
FältCom ECII SE with a suitable time of pause the lift phone accept that the telephone line
manages to call up the pre-programmed number. Afterwards the lift phone uses the telephone
line for intended functions. For more information read Programming.
By connecting the lift phone to a GSM adapter which simulates an analogue telephone line
the lift phone easily can send alarms via the GSM network. Contact your distributor for more

Manual FältCom ECII SE Eng Page 15 of 36
information. For all alarm communication via the GSM network it is very important that it is
investigated if the communication still works in case of power failure.
The lift phone can also be connected to a VoIP system but then a special device must be
mounted close to the lift phone. Sometimes adjustment of the equipment is needed so the
length of the tones (DTMF) from and to the lift phone is not affected by the equipment.
Contact your distributor for more information. When using such devices it is very important
that it is investigated that the telephone line still works in case of power failures.
6.5.2 Connection with separate suspension cable
Normally, a separate suspension cable of the type round cable or flat cable is used between
the lift phone and the telephone jack. A separate suspension cable usually gives better sound
quality and less interference. The required length of cable and mounting kit can be ordered
with the lift phone.
Note that the cable brackets included in the mounting kit must be used in order to guarantee
the function. The combined wall and lift-cage brackets comprise bracket, screw, washer and
cable ties.
Check carefully that the cable will not be torn off nor squeezed or rubbed between lift
cage and shaft wall.
6.5.3 Flat cable
1. Check that the cable is long enough,
with a margin, to reach the telephone
jack.
2. Fasten the cable securely until it
reaches the lift shaft wall.
3. Secure the cable with a wall bracket
according to the figure on this page.
4. Fasten the lift-cage bracket under the
lift cage with screws, and attach the
cable to the bracket. Alternatively, the
cable can be attached to some
suitable beam on the lift cage instead
of the lift-cage bracket.
5. Draw the cable to the lift phone and
connect the wires to the terminals
marked ”TELE”.
6. Fasten the cable with cable ties or
cable clips on the outside of the lift
near the lift phone.
7. Connect the two central wires in the enclosed modular connector to the suspension
cable wire, and connect the modular connector to the telephone jack in the engine
room. Mark the connection so that it will not be removed by mistake.

Manual FältCom ECII SE Eng Page 16 of 36
6.5.4 Connection via existing cable
Warning! Make sure there is no 230–400 V in cables that you will have contact with.
Normally, the existing lift cable (usually a big flat conductor cable) goes to a cage cable box,
where you may find unused wires (if any) that can be used for the lift phone. It is important
that the used wires are next to each other in the lift cable to minimize disturbances. In case of
bad sound quality a separate cable must be used.
1. Connect a two-wire cable from the unused pair in the cage cable box and draw the
cable to the terminal strip marked ”TELE”.
2. Fasten the cable with cable ties or cable clips on the outside of the lift near the lift
phone.
3. Connect the suspension cable wire to the telephone jack in the engine room. Mark
the connection so that it will not be removed by mistake.
6.6 Connection of voltage feed
Note that separate voltage feed is only required if more than one lift phone will be connected
to the same telephone line or if single-mounted to a line voltage below 32 VDC, usually an
internal telephone exchange (PABX). This limit is possible to decrease in case of a single
mounted lift phone by mounting the attached jumper marked “J1” next to the green screw
connector. Then the lift phone can be used without a separate power supply down to 22 VDC.
Note that when the jumper is mounted it is not allowed to connect the lift phone to the public
switched telephone network (PSTN) but only to a PABX. See also section Technical Data.
The voltage feed must come from a source that will work even in case of a power failure, e.g.
the lift’s emergency light system, and must go via a special DC/DC converter. This converter
is galvanically separated from ground, which is necessary in order to avoid disturbing the
telecom station. If no existing emergency power supply is available a separate emergency
power source with a built-in battery can be used. Contact your local distributor for more
information.
1. Connect a two-wire cable to the existing suspension cable wire for emergency
lighting. Measure to verify the correct voltage between the pins.
2. Connect the cable to the DC/DC converter’s input.
3. Connect the DC/DC converter to the lift phone outlet marked ”DC”.
4. Screw the DC/DC converter on the outside of the lift and fasten the cable with cable
ties or cable clips.
When connecting two or more lift phones on the same telephone line, each phone shall be
programmed for detection of occupied line:
To deactivate this function, press:

Manual FältCom ECII SE Eng Page 17 of 36
Note: this re-programming must be done while the DC/DC converter is connected.
See more under section Busy line function.
6.7 Connection to loop amplifier
To enable passengers with impaired hearing to communicate with alarm centre there is a
possibility to connect a loop amplifier. Contact your local distributor for information about
approved loop amplifier to be used with FältCom ECII SE.
Connect the output marked “LOOP AMP” to the loop amplifier. The loop amplifier must work
during power failure. Connect it to a power supply that is working during power failures.
6.8 Connection of external pictogram
It is possible to connect external lamps to indicate alarm status on the lift phone according to
EN81:70 with the system component Pictogram Driver. It contains a DC/DC-converter and
drive circuits for external lamps. It is connected to the output marked DC/DC, to 12V
emergency power and to the external lamps. There is also a system component called
Pictogram Board with same functionality as Pictogram Driver but is delivered without the
DC/DC-converter. Contact your distributor for more information.

Manual FältCom ECII SE Eng Page 18 of 36
7 Programming
All programming i.e. alarm numbers, codes to be sent and various function selections is done
with the keypad on the back of the speech unit. For practical and ergonomically reasons it is
recommended that all programming is done at (e.g. at a desk) before the FältCom ECII SE is
mounted in the lift. All programming remains in the lift phone also after it is disconnected from
the telephone line.
The keys on the keyboard have the following functions:
Programming – Starts and end of an all programming sequences.
Sequence receiver – Used when programming more than 2 alarm receivers.
Alarm receiver 1 – Phone number to alarm receiver 1
Alarm receiver 2 – Phone number to alarm receiver 2
Alarm code 1 – Used for alarm receiver 1, 3, 4, 5 and 6
Alarm code 2 – Used for alarm receiver 2
The other keys have the same function as on a standard telephone.
At each time the keys are depressed in programming mode a short tone is heard and after
each programming sequence, there is a 4-tone for successful and a 1-tone for unsuccessful
programming.
The FältCom ECII SE can also be programmed remotely. Contact your local distributor for
more information.

Manual FältCom ECII SE Eng Page 19 of 36
7.1 Standard functions
Below follows a description of the most frequent programming sequences, which will be used
by programming the FältCom ECII SE. A number of special functions are presented below the
next section.
7.1.1 Activation of programming mode
The FältCom ECII SE can be programmed only after it has been set to programming mode.
The unit must be voltage fed from the telephone line for the keys to be activated.
Breaking alarm button is default setting for the FältCom ECII SE. In order to enter
programming mode, when the FältCom ECII SE is connected to a breaking alarm button it is
necessary to press the key and the alarm button simultaneously. Should the FältCom
ECII SE be connected to a closing alarm button or no alarm button at all, it is sufficient to
press only the key to enter programming mode. Note that the time delay for activation of
programming mode is the same as the selected time delay for the alarm button.
An alternative way to enter programming mode is to remove the telephone wire and DC/DC
connector, press and keep it pressed while reconnecting the telephone wire. After about
10 seconds you will automatically enter programming mode.
The green LED will flash as long as the FältCom ECII SE is in programming mode.
Programming mode is deactivated automatically after 30 ”idle” seconds (no key pressing).
Note that some exchanges (mainly ISDN) sometimes disconnect the lift phone after a shorter
time. All programming must then be done at a different location. Normal alarms are not
affected by this.
You may also deactivate it manually by pressing:
7.1.2 Reset of all settings
If the lift phone is moved to another building or if the alarm numbers are changed or if the lift
phone has been incorrectly programmed, the best thing to do may be to simply delete all the
old settings.
Reset (delete) all settings by pressing (in programming mode):
7.1.3 Input of alarm numbers
For connection to an alarm centre, the phone numbers and ID numbers specified by that
alarm centre must be used. The ID number tells the alarm centre which lift and which building
the alarm comes from. Note that if the alarm receiver is not a twenty-four-hour manned alarm
centre, it is important to enter more numbers!
The lift phone is programmed in the same way independently if it will call to an alarm central
or a telephone/mobile. An ID number must be programmed independently if the alarm
call should be made to an alarm central or to a telephone.

Manual FältCom ECII SE Eng Page 20 of 36
1. If required, reset all old settings:
2. Enter phone number for alarm receiver 1:
<Area code + telephone number (max 20 digits)>
3. Enter ID number for alarm receiver 1:
<ID-number (max 10 digits)>
4. Enter phone number for alarm receiver 2:
<Area code + telephone number (max 20 digits)>
5. Enter ID number for alarm receiver 2:
<ID-number (max 10 digits)>
For alarm receivers 3 to 6, use the keys:
, , and instead of under item 4 above.
These numbers automatically get the same ID number as alarm receiver 1.
NB! Do not forget to test the function by sending a test alarm.
If no ID number and/or telephone number have been programmed, a short signal only
will be heard in the loudspeaker when an attempt is made to send a test alarm.
7.1.4 Closing alarm button function
Breaking function is default. If the lift phone version with integrated alarm button is used it is
already connected to the lift phone alarm input. If the alarm button has closing function, the lift
phone must be programmed accordingly by programming:
Reset to breaking function by pressing:
7.1.5 Test alarm to test the installation
After completed installation, the lift phone must be tested with a test alarm. With the keypad
on the back of the phone, you may check that the alarm reaches secondary receivers, too.
1. Press the alarm button in the lift cage and check that the alarm reaches alarm
receiver 1.
2. Check that the alarm reaches alarm receiver 2 by pressing (in programming mode):
3. If there are more alarm receivers, test them by substituting in the sequence
above by , etc.
Table of contents
Other FältCom Security System manuals
Popular Security System manuals by other brands

Defender
Defender SLIMLINE PERSONAL ALARM quick start guide

Carmanah
Carmanah G Series quick start guide

Interlogix
Interlogix 60-578 Installation instruction

Bosch
Bosch AMAX panel 2100 installation manual

Vesta
Vesta Smart Home Security Alarm System installation guide

Cobalt Digital Inc
Cobalt Digital Inc +EAS Manual supplement