Installation manual
8
1 Dear user
Congratulations on purchasing your Faber product, a quality
product that will provide you with the warmth and atmosphere for
many years. Please read the user manual before using the re.
Should a malfunction occur despite the careful nal checks, then
you can always contact your Faber dealer.
In order to claim the guarantee, it is important that you register the
re. For this we have created a special site. You will nd all
information regarding the warranty during registration.
> Please note:
The data of your re is available in the user manual.
1.1 Introduction
Installation and maintenance of the re must be carried out by a
professional expert who has proven knowledge and demonstrable
competence. A professional craftsman takes into account all
technical aspects such as heat delivery, gas connection as well as
ue gas discharge requirements.
Where the installation instructions are not clear, he must follow
national / local regulations.
1.2 Please check
You can register your re at: www.faber-res.eu
Check the re for transport damage and report any damage
immediately to your dealer.
1.3 CE-declaration
Glen Dimplex Benelux certies that this Faber re complies with the
essential requirements of the gas appliances directive.
Product: gas room heater
Model: Vejen
This appliance complies with the Gas Appliance Regulation (EU)
2016/426.
Harmonized standards applied: EN 613 2000/A1 2003.
This declaration is invalid, if without the written permission of Glen
Dimplex Benelux:
- Changes are made to the appliance.
- The re is connected to other exhaust materials than
specied.
2 Safety instructions
> Please note:
It is advisable to always install a screen for the replace if children,
elderly or disabled people are present in the same room as the
replace. If regularly vulnerable persons can be present in the
room without supervision, sufcient protection must always
be placed around the replace.
• The appliance is designed for atmospheric and heating
purposes. This means that all visible surfaces, including the
glass, can become hotter than 100 ° C. An exception to this
is the underside of the replace and the control buttons.
• Do not use the remote control and / or app outside the room
where the re is located. So that you are always aware of the
situation around the replace when it is being operated.
• The unit must be installed and subsequently serviced every
year and maintained in accordance with these instructions
and the applicable national and local regulations.
• Ensure that the data on the type label matches the local gas
type and pressure.
• The settings and the construction of the re must not be
changed!
• Do not place extra imitation wood or other smoldering
material on the burner or in the combustion chamber.
• Do not place any combustible materials within 1m of the
radiation area of the re.
• Through the natural air circulation of the re moisture and
uncured volatile components from paint, building materials
and carpeted oors, etc. are attracted. These parts can settle
as soot on cold surfaces. Therefore do not light the re
shortly after installation.
• Light the re for the rst time and run for several hours on the
highest setting, so that the paint can cure. Provide adequate
ventilation, so that any fumes can disperse; we recommend
vacating the room during this process.
> Please note:
1. All transport packaging is removed.
2. No children and pets in the room present.
3 Installation requirements
3.1 Minimum distance to combustible materials
around the re
• Keep a minimum distance of 9cm to the back wall and 50cm
at the sides.
3.2 Flue pipe and terminal requirements
• For the supply of the combustion air and the discharge of the
combustion gases you should always use the Flue materials
specied by Faber.
> Please note: Only when using these materials can Faber
guarantee the safe and proper operation of the appliance.
* This appliance must be installed in a chlorine-free
environment.
* The outside of the concentric ue material can heat up to
+/-150°C. Ensure, when penetrating a ammable wall or
ceiling, construction with proper insulation and protection.
Ensure sufcient clearance is maintained.
* Ensure that the concentric ue pipes are supported every
meter, so that the weight of the pipes is not supported by the
re.
* It is not permitted to start directly on the device with
concentric cut down pipe material.
The air supply could then possibly be closed.
3.3 Terminals
The combined supply and discharge can be done both via wall or
through the roof or through an existing chimney. Verify if the
position of the terminal meets the local regulations regarding
ventilation openings. The ue outlet can end on an external wall or
a roof.
Check whether the outlet desired by you complies with local
requirements concerning good function and ventilation systems.
> Please note:
For a proper functioning the terminal should be at least 0,5m. away
from:
• Corners of the building
• Roof overhangs and balconies
• Eaves (with the exception of the roof ridge, see Chapter 15).