fadini TALOS Series User manual

BOLLARD WITH RETRACTABLE CYLINDRICAL POST
OIL-HYDRAULICALLY OPERATED
GB Instructions manual pages
the gate opener
1 - 20
EN 13241
EN 12453
EN 12445

Retractable Oil-hydraulic Bollard
English
GENERAL WARNINGS FOR PEOPLE SAFETY
INTRODUCTION
This operator is designed for a specic scope of applications as
indicated in this manual, including safety, control and signaling
accessories as minimum required with FADINI equipment. □
Any applications not explicitly included in this manual may
cause operation problems or damages to properties and
people. □Meccanica Fadini snc is not liable for damages
caused by the incorrect use of the equipment, or for
applications not included in this manual or for malfunctioning
resulting from the use of materials or accessories not
recommended by the manufacturer. □The manufacturer
reserves the right to make changes to its products without
prior notice. □All that is not explicitly indicated in this manual
is to be considered not allowed.
BEFORE INSTALLATION
Before commencing operator installation assess the suitability
of the access, its general condition and the structure. □
To check that the ground is stable, to avoid subsequent settling
or deformation in the trac control post installation area. □
Make sure that there is no risk of impact, crushing, shearing,
conveying, cutting, entangling and lifting situations, which
may prejudice people safety. □Do not install near any source of
heat and avoid contacts with ammable substances. □Keep all
the accessories able to turn on the operator (transmitters,
proximity readers, key-switches, etc) out of the reach of the
children. □Transit through the access only with stationary
operator. □Do not allow children and/or people to stand in the
proximity of a working operator. □To ensure safety in the
whole movement area of a bollard it is advisable to install
photocells, sensitive edges, magnetic loops and detectors. □
Use yellow-black strips or proper signals to identify dangerous
spots. □Before cleaning and maintenance operations,
disconnect the appliance from the mains by switching o the
master switch. □If removing the actuator, do not cut the
electric wires, but disconnect them from the terminal box by
loosening the screws inside the junction box.
INSTALLATION
All installation operations must be performed by a qualied
technician, in observance of the Machinery Directive
2006/42/CE and safety regulations EN 12453 - EN 12445. □
Verify the presence of a thermal-magnetic circuit breaker
0,03 A - 230 V - 50 Hz upstream the installation. □Use
appropriate objects to test the correct functionality of the
safety accessories, such as photocells, sensitive edges, etc. □
Carry out a risk analysis by means of appropriate instruments
measuring the crushing and impact force of the main opening
and closing edge in compliance with EN 12445. □Identify the
appropriate solution necessary to eliminate and reduce such
risks. □In case where the gate to automate is equipped with a
pedestrian entrance, it is appropriate to prepare the system in
such a way to prohibit the operation of the engine when the
pedestrian entrance is used. □Apply safety nameplates with CE
marking on the gate warning about the presence of an
automated installation.
□The installer must inform and instruct the end user about the
proper use of the system by releasing him a technical dossier,
including: layout and components of the installation, risk
analysis, verication of safety accessories, verication of
impact forces and reporting of residual risks.
INFORMATION FOR END-USERS
The end-user is required to read carefully and to receive
information concerning only the operation of the installation
so that he becomes himself responsible for the correct use of it.
□The end-user shall establish a written maintenance contract
with the installer/maintenance technician (on -call). □Any
maintenance operation must be done by qualied technicians.
□Keep these instructions carefully.
WARNINGS FOR THE CORRECT OPERATION OF THE
INSTALLATION
For optimum performance of system over time according to
safety regulations, it is necessary to perform proper
maintenance and monitoring of the entire installation: the
automation, the electronic equipment and the cables
connected to these. □The entire installation must be carried
out by qualied technical personnel, lling in the Maintenance
Manual indicated in the Safety Regulation Book (to be
requested or downloaded from the site
www.fadini.net/supporto/downloads).
□Operator: maintenance inspection at least every 6 months,
while for the electronic equipment and safety systems an
inspection at least once every month is required. □The
manufacturer, Meccanica Fadini snc, is not responsible for
non-observance of good installation practice and incorrect
maintenance of the installation.
DISPOSAL OF MATERIALS
Dispose properly of the packaging materials such as
cardboard, nylon, polystyrene etc. through specializing
companies (after verication of the regulations in force at the
place of installation in the eld of waste disposal). Disposal of
electrical and electronic materials: to remove and dispose
through specializing companies, as per Directive 2012/19/UE.
Disposal of substances hazardous for the environment is
prohibited.
2

TALOS 9450
TALOS 9450/HRC
TALOS 9460
TALOS 9460/HRC
TALOS 9470
TALOS 9470/HRC
TALOS 9480
TALOS 9480/HRC
4
4
4
4
4
4
4
4
500
500
600
600
700
700
800
800
TALOS 9651
TALOS 9651/HRC
TALOS 9661
TALOS 9661/HRC
TALOS 9671
TALOS 9671/HRC
TALOS 9681
TALOS 9681/HRC
12
12
12
12
12
12
12
12
500
500
600
600
700
700
800
800
Meccanica Fadini s.n.c.
Responsible Manager
DECLARATION OF CONFORMITY:
Meccanica Fadini snc (Via Mantova, 177/A - 37053 Cerea - VR - Italy) declares under its own responsibility that TALOS is in
compliance with the Directive 2006/42/EC on machinery, moreover: is to be sold and installed as a comprehensive
“Automatic System”, including the accessories and components as recommended by the Manufacturing Company. In
observance of the current directives, any automation is to be regarded as a “machine”. Therefore it is required that all the
applicable safety normsare strictly complied with by installation agents, who are also required to issue a Declaration of
Conformity. The manufacturing company is not liable for incorrect applications or misuse of its products that are declared
to be produced in compliance with the following norms: Analysis of the risk and actions to cure them EN 12445 & EN 12453,
Low Voltage Directive 2014/35/UE, Electro-magnetic Compatibility Directive 2014/30/UE. In order to certify the product
the Manufacturer declares under his own responsibility the compliance with the PRODUCT regulations under the NORMS
EN 13241-1.
GENERAL DESCRIPTION OF THE PRODUCT
Talos is a bollard tted with a fully retractable post sinking at to the ground level. It is an oil-hydraulic system, the movements of
which are by an incorporated motor-pump. It is designed to securely stop trac from an area.
The TALOS series includes a vast selection of options as indicated below, varying in height, thickness and depth of embedding
(constraint) for impact resistance (the abbreviation HRC identies those bollards having higher ratings of resistance to crash and
impact than the standard versions).
The construction features and installation procedure are the same across the entire range:
The retractable post, 275 mm diameter, is made of S235J steel (4 mm thickness) and S355J steel (12 mm thickness), cataphoresis
treated and polyester powder coating.
A stainless steel version is avialable, INOX Aisi 304 satin nish, but only in the 4 mm thickness option.
In the HRC options, the post (raised) stays embedded into the casing 40 cm (constraint) deeper rather than 20 cm as with the
standard versions, thus ensuring higher resistance to impact and crash.
The electronic controller Elpro S40 is to be installed externally, in a sheltered place.
A wide range of safety and control accessories make this bollard easy and safe to operate and therefore suitable to any
applications, either in public or private areas.
AnyTALOS can be completed with supplementary accessories, to be specied at the time of the order as required (pre-assembled
and pre-wired to the internal terminal block):
- Solenoid valve: it allows the post to lower in case of power failure.
- Presence sensor (pressure switch): it prevents the post from rising in case an obstacle stays on it.
-Beeper: an acoustic device operating during the rising and lowering movements of the post.
-Heating resistor: a device used to keep Talos warm inside when the external environment is below 5 °C.
model
320.000
420.000
320.000
420.000
320.000
420.000
320.000
420.000
stroke
[mm] stroke
[mm]
crash
resistance
[J]
model crash
resistance
[J]
post
thickness
[mm]
post
thickness
[mm]
450.000
550.000
450.000
550.000
450.000
550.000
450.000
550.000
Retractable Oil-hydraulic Bollard
English
3

NON MANDATORY FUNCTIONING TEST (not required for installation purposes)
The Talos bollard is factory-tested in any normal working conditions before being sent out to customers.
Anyway, to enable some functioning tests to be carried out before installation, it is possible to access the inner terminal block
for the electrical connections by removing the hatch cover: undo the two lateral screws of the cover and pull outwards the
junction box including the connector.
NOTE WELL: once test is nished, put the box and the hatch cover back.
Release spanner
with triangular socket end
Post cover with
rubber edge
n°9 Led lights ashing
amber in colour
Back-reecting sticker
with logo
Box to house the
electric cable from
the electronic controller
Cover
plate
Casing for concrete
embedding
Retractable, cylindrical post.
500/600/700/800 mm stroke options
Thickness: 4 mm or 12 mm
Stainless steel inox: only 4 mm
!
Pic. 1
Pic. 2
H
Stroke 500
Stroke 600
Stroke 700
Stroke 800
Junction
box with
connector
Open the
connector
and carry out
the connections
as indicated
in Pic. 14 page 11
M10
MAIN COMPONENTS
Retractable Oil-hydraulic Bollard
English
stroke constraint H
[mm] [mm] [mm]
500 200 830
200 1.010 [A]
400 1.010
600 200 1.010
400 1.210
700 200 1.010
400 1.210
800 200 1.210
400 1.310
[A] Ground casing on demand,
not standard.
4

230 V - 50 Hz
!
COMPONENTS FOR A COMPLETE INSTALLATION
List of all the possible accessories for system operations and safety (see general catalogue).
General indicative diagram:
1 - Miri 4 Led asher
2 - Elpro S40 electronic controller with Vix 53 radio receiver
3 - 0,03 A magnetic thermal circuit breaker (not in the catalogue)
4 - Loop detector for metallic masses, two channels
5 - Voltage stabilizer for single coil application (Talos with solenoid valve)
6 - Burglar-proof enclosure
7 - Fit 55 photocell receiver, recess mount
8 - Pre-assembled loop with power supply cable
9 - Post for Fit 55 photocell projector
10 - Oil-hydraulic bollard Talos series
11 - Vix 53 remote control transmitter
12 - Post for Fit 55 photocell receiver
13 - Visual 344 post to take command accessories
14 - Chis 37 key-switch
15 - Warning signal bollard in motion
16 - Fit 55 photocell projector, recess mount
17 - Double head trac lights
18 - Birio A8 aerial, wall mount
Make sure that the electric cables of all the accessories are led to the electronic controller
Elpro S40 without interfering with any other utility.
Depth and diameter of the cable ducts are to comply with the principles of the good
installation technique and the safety rules in force on the place of the application. Pic. 3
Retractable Oil-hydraulic Bollard
English
5

M10
M10
M10
!!
M10
M8
M8
1)
3) 4)
5)
REMOVE THE BOLLARD FROM ITS CASING
Remove the M10 screws on
the squared cover plate
Remove the inner xing plate
Screw the two lifting rings
down into the pre-holed seats
NOTE WELL: make sure the
ground cable is
disconnected from the
casing before lifting
Carefully hoist and remove the inner
assembly of the bollard by a winch. Make
sure the cables are not torn or cut or the
inner hydraulic pipes are damaged in this
phase.
Casing to set
into a concrete
foundation
Pic. 4
Retractable Oil-hydraulic Bollard
English
2)
6

P
!
1,0 m
80 - 90 cm
21 cm
43 cm
Ø 50
Elpro S40
21 cm
0.0 0.0
6 -12 cm
6 -12 cm
CEMENTINGTHE CASING
A pit is to be dug into the ground following the dimensions as indicated in Pic. 5.
INTERNAL SIDE TO PROTECT
EXTERNAL SIDE
Road surface
and walking level
20 cm
approx
stroke constraint P
[mm] [mm] [mm]
500 200 1.000
200 1.200
[A]
400 1.200
600 200 1.200
400 1.400
700 200 1.200
400 1.400
800 200 1.400
400 1.500
[A] Ground casing on demand,
not standard.
possible
submersed
pump
Soakaway pebbles
Pic. 5
Lay a corrugated tube, Ø 50 mm, to lead the electric cables through it, from a junction box or directly from the electronic
controller Elpro S40 (Pic. 6).
NOTE WELL: the foundation casing is to be set
perfectly levelled, and the upper edge must be
1-2 cm higher than the surrounding walking area.
Inlet (from below) of
the Ø 50 tube leading
the electric cables
Pic. 6
Soakaway pebbles
Fit the two M10 lifting rings diagonally
across the casing to allow hoisting and
positioning
Retractable Oil-hydraulic Bollard
English
!
Check soil natural permeability: 50 liters of water must be able to soak away in not
longer than 30/40 minutes. Otherwise provide a pipe to allow rain water to ow
either into the sewage system or a sump well equipped with a submersed pump.
7

INSTALLING THE BOLLARD
Once concrete has rmly set around the casing, put the inner assembly back into it. Lastly remove the lifting rings.
By a winch put carefully the inner assembly
back into the casing, make sure the cables are
not torn or cut or the inner hydraulic pipes are
damaged in this phase
They must be on
the same level
!
!
!
NOTE WELL: IT IS IMPORTANT THAT THE ENTIRE ASSEMBLY IS
PERFECTLY FITTED BACK INTO ITS SEAT. THE PLATE, TO WHICH
THE MOTOR-PUMP IS FIXED, MUST FIT WELL ONTO THE INNER
SURFACE OF THE CASING. REMOVE POSSIBLE FRAGMENTS.
The upper level of the foundation casing is to be 1-2 cm higher than the surrounding walking surface, in
order to limit the amount of water that may get inside it.
Cast concrete all around the casing up to 5-10 cm from walking level. Wait all the time required for concrete
to set rmly (at least 7 days) and complete the nishing of the road surface.
Soakaway pebbles
Concrete
Asphalt
Pic. 7
IT IS MOST IMPORTANT THAT THE CASING IS 1-2 cm HIGHER THAN AREA FINISHED LEVEL.
IN NO WAY THE TALOS IS TO BECOME A WATER GATHERING BASIN. AVOID AREAS WHERE
SOIL TENDS TO SAG TO PREVENT THE BOLLARD FROM BEING FLOODED.
IN CASE OF SNOW, THE FLAT SURFACE OF THE COVER PLATE CAN BE EASILY CLEARED EVEN
BY HEAVY MECHANICAL MEANS.
Pic. 8
Retractable Oil-hydraulic Bollard
English
They must
t so that the dedicted
groove in the casing is
tted perfectly
!
0.0
Ø 50
50 - 60 cm
1-2 cm
5-10 cm
8

!min 80 cm
!
!
Visual 344
ø 275
CHIS 37
Elpro S40
min. 1,0 m min. 1,0 m
1.890
ARRANGING FOR THE MAGNETIC LOOPS (OPTIONAL)
IMPORTANT: Make sure that the area near and below the ground level
where the accessories are installed is clear from electromagnetic
sources to prevent interference problems with the detections of the
loops and with any other electronic device to control the installation.
The magnetic loop is a safety device, permanently active, to detect
vehicles: the bollard is prevented from rising while any vehicle is transiting
on the loops.
A hole is to be dug to take the pre-assembled loops that can be provided
by the company (see the instructions coming with this item to be informed
about all of the possible congurations available).
Pic. 9
Entry loop Exit loop
Pic. 10
- Pre-assembled loop, 6 metres
circumference (optional, see catalogue).
- Pre-assembled loop, 12 metres
circumference (optional, see catalogue).
Power supply cable
max 10 metres,
pre-tted to the loops
Detector for metallic masses.
See the instructions supplied
with it.
(Optional, see catalogue).
(See the instructions provided with this item)
magnetic loop
INSTALLING THE PHOTOCELLS (OPTIONAL ITEM) AND OTHER COMMAND ACCESSORIES AS REQUIRED
The photocells are to be installed at a suitable minimum distance to operate properly as indicated in Pic. 11.
Visual 344, with 2 or 3 elements, is a post made of metal designed to provide a support to the electronic controller Elpro S40 in
those applications in the open where no other structures are available to this purpose. it is designed to also take any other control
accessories, such a key-switch or a video-intercom system, as required near the installation (Pic. 11).
Photocell
FIT 55
Photocell
FIT 55
Pic. 11
Electric cables laid underground through a corrugated sheath
Photocell
FIT 55
Photocell
FIT 55
Retractable Oil-hydraulic Bollard
English
9

Elpro S40
!
!
IP 66
ELECTRIC CONNECTIONS TO THE ELECTRONIC CONTROLLER ELPRO S40
The electronic controller Elpro S40 is to be installed in a dry and protected place to prevent unauthorized actions.
Make sure that all the electric cables of the command and safety accessories are properly led to the controller (Pic.3).
Through the previously laid corrugated tube pull a multicore cable, type BUT FLESSIBILE FG 7OR 12x1,5 mm² (not supplied
with the equipment, but available on request as per catalogue) or a multicore cable, type BUT FLESSIBILE FG 7OR 16x1,5 mm²
(not supplied with the equipment, but available on request as per catalogue) for the electrical connections to the Elpro S40
controller, depending on which model of TALOS is required to be installed (see page 18, point 8).
NOTE WELL: Lay a ground cable suitable to the type of installation as required either for public or private users and in
compliance with the existing safety norms. A screw is provided for proper connection.
For applications in public areas use a cable having a section of 16 mm².
Multicore cable
and ground cable
Pic. 12
The multipole cable BUT FLESSIBILE FG 7OR 12x1,5 mm² or BUT FLESSIBILE FG 7OR 16x1,5 mm²
(see page 18, point 8) is required to have a maximum length of 50 m.
The ground cable must have a section complying with the installation requirements.
ATTENTION: before carrying on with wiring, it is recommended to identify which optional accessories TALOS
is actually tted with (pressure switch, solenoid valve, beeper or heating resistor), so to arrange the proper
connections to the respective terminals in the connector.
Hydraulic
motor-pump
Pressure switch Beeper Heating resistor
Solenoid valve
Beeper
inside
the post
Heating resistor
inside
the casing
Pic. 13
Retractable Oil-hydraulic Bollard
English
Pressure switch
or presence
detector
Solenoid valve
Hydraulic
motor-pump
10

The bollard comes pre-wired (electric motor, limit switches, LEDs and possible optional items such as: beeper, solenoid valve and
pressure switch). Connections are in a dedicated watertight box.
Remove the connector from the junction box and bring the connections to the respective terminals by means of a multicore
cable (not supplied with the equipment).
Retractable Oil-hydraulic Bollard
English
8
7
6
5
4
3
2
1
16
15
14
13
12
11
10
9
53
51
17
16
52
18
IP 66
IP 66
!
!
Pre-wiring box
with connector
led
asher
and/or beeper
motor
common
led and/or beeper common
motor live
(Pic. 17) [B]
motor live
(Pic. 17) [B]
Card of the
“Heater
Talos series”
(if mounted)
ATTENTION: a 40 μF capacitor is pre-wired inside the junction box. For the Talos option 4 mm
thickness (fe steel and Inox/stainless steel) do NOT connect any more capacitors to the terminals
A and B of the Elpro S40 controller unless required to achieve a good performance of the bollard.
For the Talos option 12 mm thickness a 20 μF capacitor is required to be added to the terminals A
and B of Elpro S40.
Pic. 14
ATTENTION: TIGHTEN THE CABLE GLAND VERY
HARD BEFORE FITTING BACK THE CONNECTOR,
OTHERWISE GRADE OF PROTECTION FROM
SEEPAGE MAY BE AFFECTED.
1
2
pressure switch (if tted)
to be series connected with
the other safety accessories
12
11
56 ground limit switch
blue and gray cables - green wires
limit switch opening
gray cable - white wire
(Pic. 16) [C]
limit switch closing
blue cable - white wire (Pic. 16) [C]
55 limit switch +24 Vdc
blue and gray cables - brown wires
(see the instructions enclosed with the item)
Connections to the terminals
in the Elpro S40 controller
16
15
16
15
24 Vdc
23
22
9
10
24 Vdc power supply
for presence sensor
power supply
230 V voltage stabilizer
50 Hz for solenoid valve
24 Vdc
In case of solenoid valve only
or solenoid valve with
obstacle detector
In case only the obstacle detector
is installed
11

!
NC
230 V
!
FIRST RUNNING TEST
ATTENTION: supply the system with power only
when wiring is completed.
Pic. 15
All NC contacts to
the Elpro S40
controller must be
closed
Once the bollard and all of the the safety (make sure that all the NC contacts
in the Elpro S40 controller are actally closed) and command accessories are
nally installed, the respective connections to Elpro S40 done and the risk
analysis completed, the rst running test can be carried out.
If a remote control is available, once satised it has been properly match
encoded with the radio receiver following the instructions provided with it,
pulse once for the post to rise.
[C] Check the electrical connections to the limit switches; then, once the electric power is supplied, check the status of
the LEDs rst of all as follows: with the post in down posistion the L8 LED must be OFF, while L9 must be ON; if not, swap
the connections to terminals 11 and 12 in Elpro S40.
ATTENTION: the post must be fully down. If the post goes up, even partially,
during the installation phase, override the system by the manual release and
allow for the post to go down completely to the end of the permitted stroke,
then tighten by the release spanner (Pic. 23).
SOLENOID VALVE
Voltage stabilizer
Connect a voltage stabilizer
if the bollard is tted with a
solenoid valve
Pic. 16
If the application requires more than one bollard, go through all of the steps with each of them.
L8 = Limit switch Opening M1, normally ON, o with the post in down position
L9 = Limit switch Closing M1, normally ON, o with the post in up position
Retractable Oil-hydraulic Bollard
English
55 56 55 56
12

M10
!
!
!
M10
[B] Once satised that voltage is properely supplied to the system, and provided that the LEDs of the limit switches are correctly
switched (post down L8 is OFF), by the rst pulse the post should rise, if not swap the motor live connections (in Elpro S40)
after voltage supply to the system has been switched o.
ATTENTION: a 40 µF capacitor is pre-wired inside the junction box. For the Talos option 4 mm thickness (steel
and inox/stainless steel) do NOT connect any more capacitors to the terminals A and B of the Elpro S40
controller unless required to achieve a good performance of the bollard. For the Talos option 12 mm thickness
a 20 µF capacitor is required to be added to the terminals A and B of Elpro S40.
common
common
connections to the electric motor
of the hydraulic motor pump
Bollard raised:
gateway closed
1° pulse
If the application requires more than one bollard, go through all of the steps with each
Pic. 17
FIXING THE COVER PLATES OF THE BOLLARD
NOTE WELL: BOLLARD AND COVER PLATE ARE TO BE
PERFECTLY CENTERED, SO THAT THE GAP BETWEEN
BOLLARD AND COVER PLATE HOLE IS EQUALLY
SPACED ALL AROUND
The cover plate is to rmly rest all over the
surface and closely adhere to the circular ange
around the post
Pic. 18
Pic. 19
GREASE
NOTE WELL: IT IS RECOMMENDED
THAT ALL OF THE FIXING SCREWS
BE GREASED
Retractable Oil-hydraulic Bollard
English
13

230 V 230 V
BOLLARD WITH SOLENOID VALVE (OPTIONAL ACCESSORY)
With the version of the bollard where a solenoid valve (24 Vdc) is tted, in case of power failure, the post is allowed to lower by
itself at to ground level.
If a solenoid valve is tted, a voltage stabilizer is also required: this accessory is absolutely necessary and is to be tted between
the solenoid valve power output (terminals 22 and 23) and the solenoid valve.
Be reminded that only one stabilizer can be tted to each solenoid valve.
Pic. 20
Post raised:
gateway closed
Post lowered:
gateway cleared
connect the voltage
stabilizer if the bollard is
tted with a solenoid valve
Stabilizer
SOLENOID VALVE
!ATTENTION: WITH POST THICKNESS 4 mm, BOTH FE STEEL AND INOX/STAINLESS STEEL, IT IS REQUIRED THAT
THE POST BE ASSISTED TO REACH THE FULLY FLAT DOWN POSITION.
Retractable Oil-hydraulic Bollard
English
Pic. 21
Pressure switch adjustment:
1) Unscrew the M5 pin
2) Adjust the sensitivity using an
allen key size 6:
Clockwise = increase detection
threshold (kg).
Anti-clockwise = decrease
detection threshold (kg).
Once regulation is nished tighten
the M5 adjustment pin.
min 15 kg (Factory calibrated)
1)
2)
+
-
power supply
for presence sensor
(if tted)
PRESENCE
SENSOR
910
BOLLARD FITTED WITH PRESSURE SWITCH ie. PRESENCE DETECTOR (OPTIONAL ITEM)
In the version where the bollard is tted with a pressure switch, any obstacle standing on the post prevents it from rising, or should
the post be in the rising phase it reverses movement and lowers completely at to ground level.The pressure switch is factory preset
for a minimum weight of about 15 kg. A new setting is possible to be made though, in compliance with the installation requirements.
hydraulic
motor
pump
hydraulic
motor
pump
14

1) 2) 3)
Pic. 22
MANUAL RELEASE AND LOWERING OPERATIONS
The bollard has an override system allowing for the manual lowering
of the post. A spanner with a universal triangle socket at the end is
supplied with the equipment to release the unit and allow manual
lowering.
ATTENTION: once the post has been manually lowered, rising can
be made possible only by powering the system and pulsing it to
rise.
Pic. 23
Help the post
lowering
Tighten hard by the
release spanner
(clockwise)
Insert the spanner into the release seat
having a triangular prole, one full turn
is required anticlockwise
Retractable Oil-hydraulic Bollard
English
15

give to the end-user of the installation
MAINTENANCE RECORD
hand over to the end user of the installation
Installation address:
Installation type:
Sliding gate
Over-head door
N°
1
2
3
4
5
6
Service date
Stamp and signature
installation technician/maintainer
Signed for acceptance
end user
buyer
Technical maintainer End user/sService description
Lateral folding
door
Swinging gate
Folding door
Bollard
.............................
Road barrier
Operator model:
Dimensions per gate leaf:
Weight per gate leaf: Installation date:
Quantity of models
installed:
Maintainer: Date:
NOTE WELL: this document must record any ordinary and extraordinary services including installation, maintenance,
repairs and replacements to be made only by using Fadini original spare parts.
This document, for the data included in it, must be made available to authorized inspectors/ocers, and a copy of it must
be handed over the end user/s.
The installer/maintainer are liable for the functionalities and safety features of the installation only if maintenance is
carried on by qualied technical people appointed by themselves and agreed upon with the end user/s.
X
the gate opener
Retractable Oil-hydraulic Bollard
English
16

Retractable Oil-hydraulic Bollard
English
OPERATIONS FOR ORDINARY ROUTINE MAINTENANCE OF FADINI AUTOMATIC BOLLARDS (EVERY SIX MONTHS)
The standard maintenance routine sequence is as follows:
• Clean the ground cylinder and suck all material settlements.
• Clean water drains located at the bottom of the ground cylinder and/or excavation pit.
• Check any possible oil leaking from the hydraulic piston and, in case, x it.
• Overhaul the screws fastening the bollard to the ground cylinder, making sure they are properly tightened and lubricated.
• Check the oil-hydraulic motor-pump and oil pressure by assessing the rising times of the bollard. If required, top up oil in the
reservoir and/or parallel add an extra capacitor to the existing one (instructions manual is to be referred to).
• Check the correct functioning of the signal LED lights (if incorporated) in the bollard head.
• Sight check the electronic board controlling the bollard/s (e.g.:“ooded” relay contacts, oxidized terminal clamps, etc.).
• Check the correct functioning and positioning of the limit switches.
• Check the release system for bollard manual operations.
• Clean and recondition the rising cylinder if required, e.g.: paint patching up, replacing the back reecting sticker and /or the
cover tted with rubber edge.
IF OPTIONAL ACCESSORIES ARE INCLUDED, FURTHER MAINTENANCE IS REQUIRED AS FOLLOWS:
• Check the correct functioning of the safety accessories such as the inductive loop/s and the photocells.
• Check the correct functioning of the radio receiver and all of the remote controls.
• Check the correct functioning of the pressure switch.
• Check the correct functioning of the beeper.
• Check the correct functioning of the trac lights and the respective control card.
• Check the correct functioning of the solenoid valve in emergency cases such as power failure or disconnection, assess
therefore the status of the 24 Vdc voltage stabilizer.
• Check the correct functioning of EAR 35 acoustic analyzer to lower the bollard in emergency.
17

Retractable Oil-hydraulic Bollard
English
!
! !
!
Meccanica Fadini is not liable for any possible damages derived from incorrect use or from any use not
indicated in this manual, furthermore it is not answerable for malfunctioning caused by the use of
materials or accessories not approved by the company itself.
It is to be noted that the product respects the impact and breakout resistance values as indicated provided
that the installation of the same is carried out in observance of the specications included in this manual of
instructions. Various factors are to be carefully taken into consideration such as compaction index, soil
permeability coecient, concrete type, which may aect the indicated values even signicantly.
This symbol indicates that a particular attention is required on the installation phases and on running the
operator. Failure to observe these indications may cause incorrect functioning of the bollard.
INFORMATION ABOUT SAFETY AND PROPER FUNCTIONING OF THE SYSTEM
1) Installation operations, testing, analysis of the risks and future maintenance are to be executed by qualied and authorized
technicians in compliance with the existing regulations (www.fadini.net/supporto/download)
2) This automatic system is intended to be exclusively used for the applications described in this manual, including all of the
safety and command accessories, at least as required.
3) Any application not indicated in this manual may cause malfunctioning or damages to people and properties.
4) Make sure the soil is adequate to take the bollard to avoid that settling at a later stage causes problems to the system
5) Make sure the site is free from utilities that may interfere with it.
6) Make sure that electromagnetic sources are at a suitable distance from the accessories, especially from the loop detectors.
The magnetic elds of other sources might aect the detections of the safety loops as well as those of the other command
and safety devices of the system.
7) Make sure the power supply to the electric motor is 230 V (50 Hz).
8) It is recommended either of the following power supply cables:
- cable type BUT FLESSIBILE FG 7OR 12x1,5 mm² (up to 50 m maximum): for the TALOS bollard in the standard version,
without optional accessories;
- cable type BUT FLESSIBILE FG 7OR 12x1,5 mm² (up to 50 m maximum): for the TALOS bollard in the version tted with
one optional accessory maximum (either solenoid valve, obstacle detector or heater);
- cable type BUT FLESSIBILE FG 7OR 16x1,5 mm² (up to 50 m maximum): for the TALOS bollard in the version tted with
two or all of the three optional accessories (solenoid valve, obstacle detector and heater);
N.W. The presence or not of the beeper on the TALOS bollard, does not aect the cable choice.
The section of the ground cable is to be chosen in compliance with the requirements of the installation site.
9) In case any components or accessories need replacing, use only original parts as provided by the manufacturer.
10) The installer shall provide the nal user with information related to all of the operating commands and functions of the
system, including that concerning lowering of the post in case of an emergency (manual release operation).
11) The installer shall inform the nal user of the dangers coming from the presence of persons, especially children, in the
proximity of the bollard.
12) The manufacturer reserves the right to change this manual without previous notice.
As far as conguration and execution of the system are concerned, these are to comply with the laws in the country of
installation.
18

Retractable Oil-hydraulic Bollard
English
PRODUCT SPECIFICATIONS
Fully retractable automatic bollard for very heavy duty applications, made up of an incorporated oil-hydraulic motor pump
unit and an oil-hydraulic actuator inside the moving cylinder. Suitable for protecting garages, shops, gateways to shopping
centers, banks, car saloons and generally speaking all those areas under risk of attack requiring safeguard. For residential,
community and industrial installations. IP67. The height of the rising cylinder (out of the ground) can be 500/600/700/800
mm. Rising cylinder made of S235JRH steel, thickness 4 mm and Ø 275 mm or S355J2H steel, thickness 12 mm, cataphoresis
treated and powder coated. Rising cylinder also available in 4 mm AISI 304 or AISI 316 brushed stainless steel. Rubber ring on
rising cylinder head. Cataphoresis treated aluminium cover, nished to provide a slip-proof treading surface. Rising cylinder
tted with high intensity, microprismatic, retroreecting approved sticker (h 80 mm), and 9 signalling LEDs all around the top
with ashing light. Hot dip galvanized steel casing for ground foundation, tted with a cover plate allowing access to the
hydraulic release for manual lowering of the bollard in an emergency by a special spanner having a triangular socket. With
rising cylinder thickness 4 mm: impact resistance 52.000 J, breakout resistance 320.000 J. HRC (High Resistance Cylinder)
option: impact resistance 70.000 J, breakout resistance 420.000 J. With rising cylinder thickness 12 mm: impact resistance
60.000 J, breakout resistance 450.000 J. HRC (High Resistance Cylinder) option: impact resistance 90.000 J, breakout
resistance 550.000 J. Static load max 1.500 kg in standing position, max 20.000 kg in lowered position. Working temperature
-40 °C +80 °C. Supply voltage 230 Vac ± 10%, 50 Hz. Absorbed power 1.100 W. Connector and junction box IP 66 for cabling.
Rising time, rising cylinder thickness 4 mm: ~ 2,14 s [height H 500 mm]; ~ 2,57 s [height H 600 mm]; ~ 3,0 s [height H 700 mm];
~ 3,42 s [height H 800 mm]. Rising time, rising cylinder thickness 12 mm: ~ 2,80 s [height H 500 mm]; ~ 3,40 s [height H 600
mm]; ~ 4,0 s [height H 700 mm]; ~ 4,50 s [height H 800 mm]. Frequency of use 3.000 cycles/day. Hydraulic device to lock the
bollard in standing position, solenoid valve on request for the spontaneous descent of the bollard in case of power failure.
91
100
77
63
25
31
1.000 1.400 2.100
37
104
150
88
72
43
36
26
1.000 1.400 2.100
4 mm
Vehicle SPEED (km/h)
52.000 J
320.000 J
4 mm / HRC
70.000 J
420.000 J
vehicle
MASS (kg)
108
120
91
76
39
33
27
1.000 1.400 2.100
119
150
101
82
48
41
33
1.000 1.400 2.100
12 mm 12 mm / HRC
60.000 J
450.000 J
90.000 J
550.000 J
Various factors, such as the compaction index, soil permeability coecient
and kind of concrete may reduce the values indicated in the diagram even
signicantly.
Vehicle SPEED (km/h)
vehicle
MASS (kg)
Various factors, such as the compaction index, soil permeability coecient
and kind of concrete may reduce the values indicated in the diagram even
signicantly.
Vehicle SPEED (km/h)
vehicle
MASS (kg)
Various factors, such as the compaction index, soil permeability coecient
and kind of concrete may reduce the values indicated in the diagram even
signicantly.
Vehicle SPEED (km/h)
vehicle
MASS (kg)
Various factors, such as the compaction index, soil permeability coecient
and kind of concrete may reduce the values indicated in the diagram even
signicantly.
19

TECHNICAL DATA
Individual weight of the bollards [D]
500
500
600
600
700
700
800
800
4
4
4
4
4
4
4
4
500
500
600
600
700
700
800
800
12
12
12
12
12
12
12
12
TALOS 9450
TALOS 9450/HRC
TALOS 9460
TALOS 9460/HRC
TALOS 9470
TALOS 9470/HRC
TALOS 9480
TALOS 9480/HRC
TALOS 9651
TALOS 9651/HRC
TALOS 9661
TALOS 9661/HRC
TALOS 9671
TALOS 9671/HRC
TALOS 9681
TALOS 9681/HRC
ELECTRIC MOTOR
Absorbed power 1.100 W
Power supply 230 V
Frequency 50 Hz
Rated current 1,8 ÷ 3,5 A
Maximum current 6 A
Intermittent service S3
Capacitor 40 μF
Motor rotation speed 2.800 rpm
HYDRAULIC MOTOR PUMP TUNIT 3.20LP
Pump type P20
Working pressure 1 MPa (10 bar)
Working temperature - 20 °C + 80 °C
Oil type Oil Fadini - code 708L
Oil reservoire 3 liters
Protection grade
IP 67 without pressure switch and solenoid valve
IP 65 with pressure switch and solenoid valve
BOLLARD
Post diameter Ø 275 mm
Post thickness 4 and 12 mm
Post height range 500, 600, 700 and 800 mm
Finishing of the Fe post polyester powder coating
Piston diameter 30 mm
Shaft diameter 16 mm
Piston stroke range 510, 610, 710 and 810 mm
Factory set thrust power 61 daN (61 kg)
Frequency of use very intensive (3.000 cycles/day)
LED / beeper power adaptor in: 230 V - 50 Hz out: 12 Vdc 600mA
LED lights 12 Vdc
Post material S235JRH (4 mm) steel
S355J2H (12 mm) steel
AISI 304 inox / AISI 316 inox
brushed SS steel
standard HRC
Impact resistance (thick. 4) 52.000 J 70.000 J
Crash resistance (thick. 4) 320.000 J 420.000 J
Impact resistance (thick. 12) 60.000 J 90.000 J
Crash resistance (thick. 12) 450.000 J 550.000 J
Maximum static load 20.000 kg 20.000 kg
Model weight
[kg] time [s]
rising lowering
stroke
[mm] post
thickness
[mm]
Model weight
[kg] time [s]
rising lowering
stroke
[mm] post
thickness
[mm]
196
202
226
234
232
240
240
246
2,14 2,00
2,14 2,00
2,57 2,40
2,57 2,40
3,00 2,80
3,00 2,80
3,42 3,20
3,42 3,20
234
252
258
266
263
275
288
291
2,80 2,14
2,80 2,14
3,40 2,57
3,40 2,57
4,00 3,00
4,00 3,00
4,50 3,42
4,50 3,42
Retractable Oil-hydraulic Bollard
400 400
475
575
H
570
Ø 275
500
600
700
800
352217
English
GB 2012/19/UE Directive
Re. disposal of electric
and electronic waste
DISPOSE PROPERLY OF MATERIALS
ARMFUL TO THE ENVIRONMENT
Via Mantova, 177/A - 37053 Cerea (VR) Italy
Ph. +39 0442 330422 Fax +39 0442 331054
stroke constraint H
[mm] [mm] [mm]
500 200 830
200 1.010 [A]
400 1.010
600 200 1.010
400 1.210
700 200 1.010
400 1.210
800 200 1.210
400 1.310
[A] Ground casing on demand,
not standard.
2018/11
[D] With Talos models tted with a solenoid valve and moving cylinder thickness
4 mm, the weights are 15 kg higher than those indicated in the table.
This manual suits for next models
8
Table of contents
Other fadini Control System manuals
Popular Control System manuals by other brands

VALTIR
VALTIR EURO-ET END TERMINAL Product Description Assembly Manual

GE Lighting
GE Lighting DALI 64668 operating instructions

Omni
Omni HD10 user manual

Techno CNC Systems
Techno CNC Systems WinCNC user manual

Pilz
Pilz PNOZ m ES RS232 operating manual

Nuvation Energy
Nuvation Energy NUVSSG-1250-100 product manual