SPECIFICATIONS:
Detection Type Photoelectric Chamber
Power Source 9V DC Battery
Standby Current 15uA max
Alarm Current 30mA max
Alarm Sound Level 85 Decibels at 3 metres
Operation Temperature 5°C to 45°C
Ambient Humidity 10% to 90%
Sensitivity to Smoke 3.0 - 6.0% Obs/m
Compact Size 110mm diameter
FEATURES:
DC operated photoelectric type smoke alarm
Photoelectic sensor for slow smouldering fires
Insect proof
Test button
Environmentally friendly non-radioactive technology
High and stable sensitivity
Quick fix mounting bracket for easy installation
Fitting and battery tamper-resist feature
LED operation indicator
Extra loud alarm sound over 85 dB
Low-battery and battery missing warning indicators
Auto reset when smoke clears
IMPORTANT: This manual contains important
information about the installation and operation of
your smoke alarm. Please read carefully before
installation and keep for future reference. Please
ensure that this leaflet remains in the household
where the alarm is installed.
WARNING: This smoke alarm is designed to alert
you to the presence of smoke. It cannot prevent a
fire. There are hazards against which smoke
alarms may not be effective such as smoking in
bed, explosions, etc. The ultimate responsibility for
fire protection rests with you. This responsibility
includes escape planning, safety checks and an
effective warning system. In case of fire, a well
placed, properly looked after smoke alarm may
provide a few seconds so that you can escape and
call the fire brigade.
IMPORTANT SAFETY INFORMATION
1. This smoke alarm requires a constant working 9
volt battery to operate properly. This smoke alarm
will NOT work if DC power is not connected, has
failed or has been interrupted for any reason, the
battery is removed, drained or improperly
connected. DO NOT use any other kind of battery
PRODUCT MANUAL
BEDROOM HALL BEDROOM
LIVING ROOM KITCHEN
BASEMENT
MULTI-STOREY RESIDENCE
KEY:
Minimum required smoke alarm locations
Recommended additional smoke alarm locations
Smoke alarms with hush features recommended
for additional protection
DINING ROOM
LIVING ROOM
BEDROOM
BEDROOM
KITCHEN
SINGLE-STOREY RESIDENCE, APARTMENT, MOBILE HOME
except as specified.
2. DO NOT connect this smoke alarm to any other
type of smoke alarm or auxiliary device, except
those listed in this manual. The test button
accurately tests all smoke alarm functions. DO
NOT use any other test method. Test smoke alarm
weekly to ensure proper operation.
3. DO NOT remove or disconnect battery to silence
unwanted alarms. This will remove your protection.
Open windows or ventilate the smoke alarm to
silence it.
4. This smoke alarm may be installed by a licensed,
qualified electrician. Observe and follow all local
and national electrical and building codes for
installation.
5. This smoke alarm is designed to be used inside
a single unit dwelling only. In buildings with several
dwellings, each individual living unit should have its
own smoke alarms. DO NOT install in
non-residential buildings. This smoke alarm is not a
substitute for a complete alarm system.
6. Install a smoke alarm in every room and on every
level of the home. Smoke may not reach the smoke
alarm for many reasons. For example, if a fire starts
in a remote part of the home, on another level, in a
chimney, wall, roof or on the other side of a closed
door, smoke may not reach the smoke alarm in
time to alert household members. A smoke alarm
will not promptly detect a fire except in the area or
room in which it is installed.
7. Smoke alarms may not alert every household
member every time. The alarm sound is loud in
order to alert individuals to a potential danger.
However, there may be limiting circumstances
where a household member may not hear the
alarm (i.e. outdoor or indoor noise, sound sleepers,
drug or alcohol usage, hard of hearing, etc.). If you
suspect that this smoke alarm may not alert
household members, install and maintain specialty
alarms. Household members must hear the alarm’s
warning sound and respond, to quickly reduce the
risk of damage, injury or death that may result from
fire. If a household member is hearing impaired,
install special smoke alarms with lights or vibrating
devices to alert occupants.
8. Smoke alarms can only sound their alarms when
they detect smoke. Smoke alarms detect
combustion particles in the air. They do not sense
heat, flame or gas. This smoke alarm is designed to
give an audible warning of a developing fire.
However, many fires are fast burning, explosive or
intentional. Others are caused by carelessness or
safety hazards. Smoke may not reach the smoke
alarm quickly enough to ensure safe escape.
9. Smoke alarms have limitations. This smoke
alarm is not foolproof and is not warranted to
protect lives or property from fire. Smoke alarms
are not a substitute for insurance. Homeowners
and renters should insure their lives and property.
In addition, it is possible for the smoke alarm to fail
at any time. For this reason, you must test the
smoke alarm weekly and replace every 10 years.
NOTE: For best protection, we recommend that
you install a smoke alarm in every room.
WHERE TO INSTALL YOUR ALARM
For best safety, install smoke alarms in every
room: Including hall, bedrooms, living rooms,
attics & basement. At the very least, install one
smoke alarm on every floor.
SMOKE ALARM PLACEMENT
Typical single-storey home
Install a smoke alarm on the ceiling or wall inside
each bedroom and in the hallway outside each
separate sleeping area. If a bedroom area or
hallway is more than 9 metres long, install a smoke
alarm at each end. If there is a basement, install a
smoke alarm on the basement ceiling at the bottom
of the stairwell.
IMPORTANT SMOKE ALARM PLACEMENT
AND EXCEPTION INFORMATION
1. Place as close as possible to the centre of the
ceiling as possible or at least no closer than 30cm
to any wall or corner.
2. Install a smoke alarm in each room that is
divided by a partial wall.
3. Install a smoke alarm in lived-in attics or attics
which house electrical equipment like furnaces, air
conditioners or heaters.
DO NOT INSTALL SMOKE ALARMS
1. Areas near appliances or where normal
combustion regularly occurs (near furnaces, hot
water heaters).
2. In areas with high humidity, like bathrooms, near
dishwashers or washing machines. Install at least
3 metres away from these areas.
3. Air returns or heating and cooling supply vents.
Install at least 900mm away from these areas. The
air could blow smoke away from the detector,
interrupting it’s alarm.
4. In rooms where temperatures may fall below
5ºC or rise above 45ºC.
5. In extremely dusty, dirty, or insect-infested areas
where loose particles interfere with smoke alarm
operation.
WARNING: Incorrect orientation will result in a
decrease in operational effectiveness.
Typical multi-storey or split level home
Install a smoke alarm on the ceiling or wall inside
each bedroom and in the hallway outside each
separate sleeping area. If a bedroom area or
hallway is more than 9 metres long, install a
smoke alarm at each end. Please install a smoke
alarm on the top of a first-to-second floor stairwell.
Heat and
smoke
from fire
Best here
Dead air space,
do not install here
30cm
minimum
30cm minimum
Dead air space,
do not install here
90cm
minimum
Best here
®
AS3786
Lic SMKH21554
SAI Global

31 Dunlop Road Mulgrave Victoria 3170
Ph 03 9538 9200 Fax 03 9538 9299
sales@masterdistributors.com.au
www.masterdistributors.com.au
INSTALLATION AND MOUNTING
INFORMATION
WARNING:
Smoke alarm installation must be in
accordance with the requirements of the national
electrical code and any local codes that may apply
and by a competent person.
1. From back of the smoke alarm, remove the
mounting plate by turning it counterclockwise. (To
later engage tamper-resist feature, twist out and
set aside one of the pins moulded into plate. Both
pins are exactly the same).
30092014
2. Secure plate to ceiling or wall with mounting
screws appropriate to the surface on which the
unit is to be mounted.
3. Lift open battery pocket door.
4. Connect new 9 volt battery to battery connector
inside battery pocket. Be sure battery is securely
connected. The red LED may blink briefly when
battery is installed.
5. Close battery pocket door, snapping it into
place.
6. Position smoke alarm to mounting plate and
turn clockwise to lock into place. To engage
tamper-resist feature, insert pin into notch and
edge of smoke alarm after alarm is properly
positioned in base.
7. Push test button to test smoke alarm. See
OPERATION, TESTING AND MAINTENANCE.
OPERATION, TESTING AND MAINTENANCE
Operation
Normal Operation When no smoke is present, a
red LED indicator will flash ONCE A MINUTE and
is an indication that the unit is operating properly.
Alarm Condition
When the unit detects smoke, the red LED
indicator will flash rapidly and alarm will sound
loudly until the air is clear.
Testing the Smoke Alarm
Test the smoke alarm once a week. If the smoke
alarm ever fails to test correctly, have it replaced
immediately! If the smoke alarm is not working
properly, it cannot alert you to a problem.
1. Test each smoke alarm to be sure it is installed
correctly and operating properly.
2. The push-to-test button accurately tests
functions. DO NOT use an open flame to test this
smoke alarm. You may ignite and damage the
smoke alarm or your home.
3. Stand at arm’s length from the smoke alarm
when testing.
4. To test the smoke alarm firmly press the test
button, and the alarm will sound a loud beep. The
alarm will stop sounding after releasing the test
button. If the alarm does not sound please re-test
the alarm.
WARNING:
If the alarm sounds and the smoke
alarm is not being tested, the smoke alarm is
Mounting Slots
Mounting
Bracket
Screw
9V Battery
sensing smoke. The sound of the alarm requires
your immediate attention and action.
WARNING: DO NOT disconnect battery to silence
an unwanted alarm. This will remove your
protection. Ventilate the unit or open a window to
remove smoke or dust.
Maintenance
The smoke alarm is virtually maintenance free.
However, under dusty conditions, a vacuum hose
may be used to clear dust through the side
opening. It is recommended to clean the alarm
monthly to keep best performance. Normally, the
alarm can be operated up to 10 years without
replacement. See the replacing date on the bottom
of the alarm unit. DO NOT attempt to remove the
cover to clean inside the smoke alarm. This will
void your warranty.
BATTERY REPLACEMENT
The power of this smoke alarm is provided by one
9V DC battery. The battery should last for at least
1 year under normal operating conditions. The
smoke alarm has a low battery indicator, an
audible ‘chirp’. It will operate at 30-40 second
intervals for a minimum of 7 days. Replace the
battery when this indication occurs. Only the
following 9V DC batteries (which are available at
hardware or electronic parts stores) may be used
for replacement.
Carbon-Zinc Type: Eveready #216; Gold Peak
#1604P; Gold Peak #1604S; Gold Peak 1604G;
Premisafe G6F22.
Alkaline Type: Eveready Energizer #522; Gold
Peak #1604A; Duracell #MN1604; Hi-Watt
#6LR61X.
Lithium Type: Ultralife U9VL-J; FDK CP-V9J; Gold
Peak CR-V9.
CAUTION: Switch off smoke alarm before
removing smoke alarm for battery replacement.
WARNING: DO NOT use any other type of battery,
other than as specified in this manual. DO NOT use
rechargeable batteries.
CAUTION: If the battery is incorrectly replaced, the
smoke alarm will not operate and may cause
damage.
WHAT TO DO IN CASE OF A FIRE
• If there is a fire in your home, the precautions
described will increase your chance of escaping
safely. The following rules should always be
highlighted during fire drills so that they are
remembered in the case of a real emergency.
• Stay calm and think clearly about the
pre-arranged escape plan.
• Leaving the house as soon as possible following
the planned escape route. Do not stop to collect
personal belongings.
• Check doors to see if they are hot. If the door is
hot, do not open it - use another escape route.
• Keep all doors and windows shut, only open as a
means of escaping.
• Smoke rises, so keep close to the floor - if
necessary crawl.
• Take short breaths and if possible, cover your
mouth and nose with a wet cloth.
• Make your way to the pre-arranged meeting point
and call the fire brigade. Give your full name and
address.
• Never re-enter a burning house. For further
information on fire safety and prevention, contact
your local fire prevention officer.
WARNING: Do not try to disassemble this smoke
alarm, as it may damage or impede the operation.
No user serviceable parts inside. The warranty will
become void if misuse or abuse is apparent. This
10 year warranty is also conditional on this unit
being installed by a licensed electrical contractor in
accordance with local building codes.
10 YEAR WARRANTY
The smoke alarm is warranted to be free from
defects in materials and workmanship for ten (10)
years from the date of purchase and is not
transferable under normal use. The warranty does
not cover natural disasters such as fire, flood,
hurricanes and tornados. Warranty is conditional
on the smoke alarm being used in the normal way
and not being modified or subject to attempted
repairs or contamination. The warranty excludes
the battery, incidental and consequential damages.
Your statutory rights as a consumer are in no way
compromised by this warranty. Master Distributors
Pty Ltd agrees to repair or replace, at its option, any
defective smoke alarm provided it is returned
personally or by prepaid delivery with a copy of
proof of purchase. This warranty does not cover
damages resulting from lack of reasonable care of
the product.
Our goods come with guarantees that cannot be
excluded under the Australian Consumer Law. You
are entitled to a replacement or refund for a major
failure and for compensation for any other
reasonably foreseeable loss or damage. You are
also entitled to have the goods repaired or replaced
if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.
Subject to those non-excluded rights and
provisions and the above warranty, Master
Distributors Pty Ltd will not be liable for injury to
persons, damage to property, or for any direct or
indirect or consequential damage as a result of
negligence or fault on the part of Master
Distributors Pty Ltd or it’s servants, agents,
suppliers and contractors or otherwise arising out
of or resulting from, whether directly or indirectly,
the use, installation or maintenance of the heat
alarm and any warranties or representations are
excluded unless given by Master Distributors Pty
Ltd in writing. Please leave this document, or a
copy, for the end user.
FOR MORE INFORMATION AND FAQ PLEASE
VISIT WWW.FAMILY-FIRST.COM.AU
Other family first Smoke Alarm manuals

family first
family first FFP240VH2 User manual

family first
family first FFP240VHX User manual

family first
family first FFCM9VH User manual

family first
family first FFP240VH2 User manual

family first
family first FFP9VH User manual

family first
family first FFP9VH User manual

family first
family first FFPDCH10Y User manual
Popular Smoke Alarm manuals by other brands

System Sensor
System Sensor ECO1003ABLINK Installation and maintenance instructions

Xtralis
Xtralis XCC-010 Product guide

Siemens
Siemens Sinteso Cerberus PRO FDA221 manual

System Sensor
System Sensor 2351B Installation and maintenance instructions

koban
koban KDH-BAT manual

techem
techem radio frequency smoke alarm 2 operating instructions